FD30 & FD60 FRAME & DOOR INSTALLATION GUIDE

Similar documents
9.1. Door Assembly Coordination. Ÿ Architrave is not described in

A F LCON PANEL PRODUCTS LTD

Installation Instructions

Unexposed face prior to testing

05/11. CI/SfB (22) fire & sound. tenon. A cost effective performer.

CERTIFICATE OF APPROVAL No CF 731 ALLGOOD PLC

A F LCON PANEL PRODUCTS LTD

FLAMEBREAK. Lippings & Facings 1. General: Rev.D

Palusol SW Door Cores Technical Manual

Fire Door Maintenance Scheme Accepted Repair Techniques

CERTIFICATE OF APPROVAL No CF 718 PILKINGTON GROUP LIMITED

Simply Fire Doors FD60 Data Sheet


General guidance. L20Doors/ Shutters/ Hatches. 1 Fire doors

PFPF and FTSG Agreed Assessment Rules for: Timber Based Doorset. FTSG N288 (e)

fd90 Technical Support Manual Innovative Solutions Halspan Fabrication Door Assemblies Frames Doors Acoustic Doors Glass Fire Doors

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

IF INSTALLING ANY OF THE PORTMAN SELF CLOSING SYSTEMS, PLEASE READ THE CORRESPONDING FITTING INSTRUCTIONS SUPPLIED WITH THE CLOSING SYSTEM FIRST

IFC FIELD OF APPLICATION REPORT PAR/10341/01

The basic tested construction for door leaves to this design comprises the following.

ADGV_001_FASTPOS. Date Jan 2013 Detail. Profile. Fastener Positioning Scale 1:20 Detail No. ADGV_ mm from top edge. 600mm MAX CTRS TIMBER STUDS

EMAC 001 ACCESS PANEL

novista doorsets hidden door system

Innova. Concealed frame doorsets. Installation instructions

Pocket Door Kit PD1 / PD2 Installation Instructions. Kit Contents.

Title: WF Report No: FEA/F98164 Revision M. WF Contract No: Prepared for: Pacific Rim Wood Ltd

A F LCON PANEL PRODUCTS LTD

03/05. CI/SfB (22) scion. The beauty of natural wood

This letter is to confirm the results of an indicative fire resistance test undertaken on 25 th November 2010.

Gyproc Proflex Access Panels - Installation Guidance Notes

Side Light Frame Pack Assembly Instructions

Side Light Frame Pack Assembly Instructions

CERTIFICATE OF APPROVAL No CF 767 RUTLAND UK

The WANZ Guide to Window Installation

CERTIFICATE OF APPROVAL No CF 370 SAMUEL HEATH & SONS PLC

Method of Build 1. Fire. Sound

Section 2 - Applications - General

method of build Komfire-75 partitioning system 75mm Steel Stud & Plasterboard Partitioning System with Square Aluminium Cover Trims KOMFORT

Installation Instructions and Ordering Information

How-To-build guide Garden shed

SPECIAL DOORS & FIRE DOORS

EI60 FD60 EI60 SMOKE SEAL. F6002 R UK - Feb (pair) Rebated meeting edge

Hardware Fitting Accessories Door Seals

ASS 70 FD folding / sliding door. Installation Guide

The legal validity of this report can only be claimed on presentation of the complete report.

Standard program overview Steel smoke-proof doors

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

Fix Out Carpentry. Carpentry - Residential Construction. Product Code: 5594

Trim type: Shadow gap. Fire rating: FD30. Enigma. Pocket sliding door systems. Installation instructions FD30 S

Method of Build 1. General

Aluminium Window Scheme to BS4873 & PAS24:2016

Title: The Fire Resistance Performance of Advantage, Advantage Plus and NOR400 Letterboxes and DV Door Viewers within Timber Based Doorsets

Halspan Technical Manual 2006

HOLLOW METAL DOOR/WINDOW SYSTEM FOR THERMALSAFE CF WALLS WINDOW ASEMBLY GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY

The Influence of Nails and Plasterboard on the Racking Resistance of Stud Walls

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

INSTALLATION MANUAL FORTRESS SERIES

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

Adjustment Has adjustment strike block screw for sealing action adjustment.

A POCKET GUIDE TO POCKET DOORS

CERTIFICATE OF APPROVAL No CF 581 CGI INTERNATIONAL LIMITED

Blankfort TM 60+ MDF. Description. Construction

6.1. General: Glass & Glazing. Glass & Glazing

Hardwood Splayed Bolection Bead. with FD60 Glass Types 1 ~ 12 (See page 6.5) when used with approved FD60 glazing systems. (See page 6.15).

Installation Instructions. 45 and 60-Minute Positive Pressure Fire-Rated Veneered Door Frame UBC & UL-10C

Kestrel Aluminium Systems Limited. Product Manual Section 11 Thermal Framing System - Fabrication. Manual Version

Halspan FD120 Technical Support Manual

FIRESTRIP 30 Version No.3 Revision Date: 19/07/2013 Page 1 of 5

ASS 70 FD folding/sliding door installation guide

Measuring Door Gap Dimensions of Swinging Fire Doors with Builders Hardware

Title: Global Fire Resistance Assessment of PT Yasanda Decorative Grooved Doorsets 30 Minutes Fire Resistance

FLAMEBREAK TECHNICAL MANUAL

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

CERTIFICATE OF APPROVAL No CF 284 INTUMESCENT SEALS

05/11. CI/SfB (22) flexplus. tenon. Versatility through simplicity.


BS EN :2006. Test of: Deceuninck Side hung and top hung window. Windows and doors Product standard, performance characteristics

The Fire Resistance Performance of Advantage, Advantage Plus and NOR400 Letterboxes and DV Door Viewers within Timber Based Doorsets

Folding Sliding door system

Extrusions GB-3-IN01. Updated: Scale: REV: - This Drawing is Protected by Copyright Altus NZ Ltd.

A F LCON PANEL PRODUCTS LTD

Installation Guide. WarmCore. Folding Sliding door system. Glass Packing. Pre-Installation. Removing the Existing Door.

Infinity 20 Min. FIRE RATED DOORS WARNOCK HERSEY INFINITY - STANDARD RAISED - 20 MIN. RATING SOFTWOOD STILE

INSTALLATION MANUAL STOREFRONT DOORS

PERIMETER SMOKE SEALS

INTUBATT FLOOR/CEILING SYSTEM & BOXOUT SYSTEM FOR FRL 120/120/120 RISF 120 INSTALLATION GUIDE

Encore 20 Min. FIRE RATED DOORS WARNOCK HERSEY ENCORE - STANDARD PANEL - 20 MIN. RATING

INSTALLATION INSTRUCTIONS

FRONT SIDE REAR BOTTOM INTELLITOUCH ONLY OPTIONAL OSD REMOTE P/N E (1 INCLUDED WITH TOUCHMONITOR) DIMENSIONAL DRAWING, 3243L SHEET 1 OF

Thermally Broken Framing and Door Installation

Heavy Wall Applied Stop Tube Frame and Door Installation

Hinge Door + Inline Panel + Return Panel

rondo exangle drywall finishing sections

Fire rating: NFR/FD30. Una. Riser door systems. Installation instructions

INSTALLATION GUIDE Timber Stairs

3M Air and Vapour Barrier 3015 Technical guide

patio door installation guide

INTERNAL LININGS INSTALLATION GUIDE

Installation - Sub Cills

Transcription:

FD30 & FD60 FRAME & DOOR INSTALLATION GUIDE SUPPORTING CONSTRUCTION The supporting construction may be timber or steel stud plasterboard partition, metal stud demountable partition or masonry wall, but shall be of a type that has been tested or assessed to provide in excess of 30/60 minutes fire resistance, at the required size, when incorporating FD30/FD60 door assembly openings. If fitted into timber/steel stud or metal stud demountable partitions, the method of forming the door assembly aperture must be as tested by the partition supplier / manufacturer. Timber Frame Installation & Gap Tolerance The frames must be fixed back to the supporting construction with steel fixings at centres not exceeding 600mm on the vertical edges (minimum 200mm from the top and bottom), and a minimum of one fitted centrally across the width of the frame head of double doors. Screws shall be of sufficient length to penetrate the supporting construction by at least 40mm, and shall be positioned such that they are not exploited by charring of the frame, irrespective of the direction of fire exposure; (this may necessitate a twin line of screws). Suitably thick packers depending on frame to supporting construction gap shall be used at all fixing positions. The Gap between the frame and the supporting construction shall be as minimal as practically possible but in any event no greater than 10mm when architraves are in use. At the perimeters of the frame and supporting construction an intumescent mastic to be applied to a minimum depth of 10mm. Architraves (minimum thickness 15mm) of the same material as the frame to be mechanically fixed providing 15mm overlap on both frame and supporting construction (see DRW1). For installations where architraves are NOT present, the gap (up to 10mm) is to be tightly packed with mineral rock fibre and capped at both frame faces with intumescent mastic to a minimum depth of 10mm. The

intumescent mastic to be an approved linear gap joint seal successfully tested in accordance with BS476-20 or BS EN 1366-4 for the required period of fire resistance. Shadow gap details may be included in the supporting construction (see DRW2) or in a frame extension at the interface of the frame and wall (see DRW3). For all other gaps between the frame and the supporting construction the method of installation should follow the recommendations of Tables 2 to 5 in BS 8214:2016, Timber based fire door assemblies - Code of Practice. No part of the rear of the frame section shall be exposed once installed, (except for integral architraves and the above shadow gap detail) and leaves must not protrude beyond the exposed face of the doorframe. The standard door assembly design should be such that single acting leaves are fully flush within the timber frame when closed and double acting doors should be centred on the timber frame depth. The face of leaves in double door assemblies should be flush with each other at meeting stiles when closed. Overpanels shall be secured into the timber frame using steel screws fixed through the rear of the frame members, passing at least 40mm into the centre of the overpanel thickness. (Screws must not be fixed through the overpanel into the stops, or vice versa). Screws must be no more than 100mm from each corner of the overpanel, and at maximum 400mm centres, with a minimum of 2no. Screws per overpanel edge. This specification applies to overpanels used with or without a transom. The gap between overpanel and frame should not exceed 3mm. The gap between the door and the timber frame, double door meeting stiles and door(s) and overpanel should be 1.5-4mm. Gaps under the door(s) to finished floor level (FFL)should not exceed 6mm for fire performance, although, if smoke control is also required, these gaps should only be 3mm and smoke seals should be included in accordance with BS8214:2016.12.3. Note: Ambient Temperature Smoke Seals (overleaf). The Overall frame depth may be increased either in solid form or with the use of extension linings where the joint/biscuit between the main frame and extension does not intrude into the plane of the door thickness.

Metal Door Frames When Aluminium and Steel frames to the specification and minimum dimensions detailed below are installed into suitable supporting constructions then the method of forming the door assembly aperture must be as tested by the frame or partition supplier/ manufacturer. The gap for fire performance and smoke control between the door and metal frame, double door meeting stiles and under the door to floor shall be as tested by the frame or partition supplier/manufacturer. There shall be no feature rebates or shadow gaps at the junction of the frame and wall with steel or aluminium frames unless tested by the frame or partition supplier/ manufacturer. Door Frame Joint Options FD30 & FD60 Drawing No. FZD0774

Smoke and Intumescent Seals Ambient Temperature Smoke Seals FD30 & FD60 where the door assembly has the additional classification requirement of S. Separate smoke seals (eg ref ST1009) or combined intumescent smoke seals that have been tested in accordance with BS EN 1634-3:2004 (ambient temperature) or BS476: part 31: section 31, 1:1983 and demonstrated not to leak by more than 3m3/m/hr (head and jambs only) at 25Pa, may be used in conjunction with Forza door assemblies to

provide smoke control. To achieve the required level of smoke control the orientation of the seals and degree of hardware interruption, door edge gaps and leaf configuration must be as tested. The threshold gap should where practicable be sealed by a flexible edge or automatic drop seal with a leakage rate as tested above or where this is not practicable due to the interference with the closing action of the door, the threshold gap should not exceed 3mm at any point. Intumescent Seal specification FD30 One no. 20 x 4mm seal fitted centrally at the head and stiles in either the door leaf or the equivalent position in the frame/overpanel and in double door flush meeting stiles. Double door rebated meeting stiles & overpanel, two no. 10 x 4mm with one in each rebate. FD60 Two no. 15 x 4mm seals fitted 10mm apart at the head and stiles in either the door leaf or equivalent position in the frame/overpanel & in double door flush meeting stiles. Double door rebated meeting stiles & overpanel, two no. 15 x 4mm with one in each rebate.