Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Similar documents
Installation and Operational Instructions for ROBA -switch Type 017._00.2

Installation and Operating Instructions for Phase Demodulator Type _.2

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

MINI-PS AC/24DC/1.3

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-E 24/0.75

QUINT-PS/ 3AC/24DC/10

Power supply CP-D 12/2.1

QUINT-PS/ 3AC/24DC/40

QUINT-PS AC/24DC/40

Reliable control of DC consumers

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Instruction manual for STA 1 sectional door operator

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

QUINT-PS-24DC/24DC/10

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

QUINT-PS/ 1AC/24DC/20

Type CP-S, CP-C & CP-A Switch mode

Power supply CP-D 24/1.3

Power supply CP-E 24/2.5

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Instruction manual for STA 1 sectional door operator

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

MINI-PS AC/2X15DC/1

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Installation and Operational Instructions for primeflex -couplings Types 933._33.1 / 933._35.1 / 933._66.1 / 933._67.1

Three-phase monitoring relay CM-PFS

CP-T range Product group picture

CP-E range Benefits and advantages

Electronic timer CT-SDD.22

Installation and Operational Instructions for ROBA -DX Couplings Type 931.3

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Power Supplies 3. SDN-C Compact DIN Rail Series

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Zelio Control Measurement Relays

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Operating instructions Fail-safe delay timer AZS About this document. Content

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

Electronic timer CT-SDS.22

CP-T range Benefits and advantages

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Liquid level monitoring relay CM-ENS.2x

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

SEPARATOR P20G TYPE USER S MANUAL

Electronic timer CT-TGD.22

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Primary switch mode power supplies Product group picture

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

User and Safety Manual ProLine P224xx P1

EC 45 flat with integrated electronics Document ID: en Operating Manual

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Power supplies CBC 140-T, CBC 140-1, CBC and CBC 140-5

Switching power supplies CP range, Linear power supplies CP-L range. Content

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Three-phase monitoring relays CM-PFE and CM-PFE.2

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

48 Series - Relay interface modules A. Features

Safety switches with slotted hole lever

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

Three-phase monitoring relay

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

E-STOP relays, safety gate monitors

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

E-STOP relays, safety gate monitors

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Transcription:

Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/ EU and the Electromagnetic Compatibility (EMC) Directive 2014/30/EU. The Declaration of Conformity is laid out in writing in a separate document and can be requested if required. Guidelines on the EMC Directive (2014/30/EU) The product cannot be operated independently according to the EMC directive. Only after integration of the product into an overall system can this be evaluated in terms of the EMC. For electronic equipment, the evaluation has been verified for the individual product in laboratory conditions, but not in the overall system. Guidelines on the Machinery Directive (2006/42/EC) The product is a component for installation into machines according to the Machinery Directive 2006/42/EC. The product can fulfil the specifications for safety-related applications in coordination with other elements. The type and scope of the required measures result from the machine risk analysis. The product then becomes a machine component and the machine manufacturer assesses the conformity of the safety device to the directive. It is forbidden to start use of the product until you have ensured that the machine accords with the regulations stated in the directive. Guidelines on the ATEX Directive Without a conformity evaluation, this product is not suitable for use in areas where there is a high danger of explosion. For application of this product in areas where there is a high danger of explosion, it must be classified and marked according to Directive 2014/34/EU. Safety and Guideline Signs General Safety Guidelines Danger Immediate and impending danger, which can lead to severe physical injuries or to death. DANGER Danger of death! Do not touch voltagecarrying lines and components. CAUTI DANGER Danger of injury to personnel and damage to machines Danger of burns when touching hot surfaces Guidelines on important points CAUTI Danger from devices caused by shortcircuits and earth short-circuits at the terminals Electronic devices cannot be guaranteed fail-safe. General Safety Guidelines Only carry out installation, maintenance and repairs in a de-energised, disengaged state and secure the system against inadvertent switch-on. During the risk assessment required when designing the machine or system, the dangers involved must be evaluated and removed by taking appropriate protective measures. To prevent injury or damage, only professionals and specialists are allowed to work on the devices. They must be familiar with the dimensioning, transport, installation, initial operation, maintenance and disposal according to the relevant standards and regulations. Before product installation and initial operation, please read the Installation and Operational Instructions carefully and observe the Safety Regulations. Incorrect operation can cause injury or damage. Page 1 of 6 1

Installation and Operational Instructions for Application ROBA -multiswitch fast switching modules are used to connect DC consumers to alternating voltage supplies, for example electromagnetic brakes and clutches (ROBA-stop, ROBA -quick, ROBATIC ) as well as electromagnets, electrovalves, etc. Fast acting rectifier ROBA -multiswitch 019._00.2 Consistently controlled output voltage in the entire input voltage range Consumer operation with overexcitation or power reduction Input voltage: 100 500 VAC Maximum output current I eff : 2 A; 4.5 A UL-approved ROBA -multiswitch units are not suitable for all applications, e.g. use of the ROBA -multiswitch when operating noisedamped brakes is not possible without taking additional measures. The product s suitability should be checked before use. Dimensions (mm) 54 Ø4.5 9 Function The ROBA -multiswitch is used for operation at an input voltage of between 100 and 500 VAC, depending on the size. After switch-on, it emits the rectified bridge voltage for 50 ms and then adjusts automatically to a pre-programmed overexcitation voltage. After the overexcitation time ends, it regulates to the permanently programmed holding voltage. For the overexcitation voltage and holding voltage values of the standard design, please see the Table at the bottom of page 3. On special designs, deviating values are possible. The overexcitation time can be adjusted via a DIP switch to 150 ms, 450 ms, 1 s, 1.5 s and 2 s. 5.6 4.5 64 54 15 30 73.6 (Type 019.100.2) 5 103 (Type 019.200.2) 17.5 Accessories: Mounting bracket set for 35 mm rail acc. EN 60715: Article No. 1802911 Electrical Connection (Terminals) 69 1 + 2 Input voltage (fitted protective varistor) 3 + 4 Connection for external contact for DC-side switchoff (with an installed bridge, switch-off only takes place AC-side with a longer brake engagement time) 5 + 6 Output voltage (fitted protective varistor) 2 Page 2 of 6

Technical Data Type 019.100.2 Type 019.200.2 Size 10 Size 20 Size 20 Frequency Input voltage [Hz] 50 60 50 60 50 60 Output current at 45 C I eff [A] 2.0 2.0 4.5 at max. 70 C I eff [A] 1.0 1.0 2.25 Fitted protective varistors U RMS [V] 300 550 550 Device fuses T 5 A (H) 5 x 20 mm T 5 A (H) 6.3 x 32 mm T 10 A (H) 6.3 x 32 mm Protection IP65 components / IP20 terminals / IP20 DIP switch Terminals Nominal cross-section 1.5 mm 2 (AWG 22-14), screws M3, max. tightening torque 0.5 Nm Ambient temperature [ C] -25 to +70 Storage temperature [ C] -40 to +70 Conformity markings Installation conditions The installation position can be user-defined. Please ensure sufficient heat dissipation and air convection! Do not install near to sources of intense heat! DANGER Danger of death! Do not touch voltagecarrying lines and components. No mains separation! Voltage control through phase angle control system Sizes Type Input voltage * ± 10 % acc. EN 50160 Overexcitation voltage Output voltage * ± 10 % Holding voltage Article number [VAC] [VDC] [VDC] 10 019.100.2 100 275 90 52 8186586 019.100.2 200 500 180 104 8185591 019.200.2 200 500 180 104 8242954 20 019.100.2 230 207 30 8225580 019.200.2 230 207 30 8237887 019.100.2 300 500 240 52 8220914 * On special designs, deviating values are possible. The values stated on the Type tag are decisive. Special designs with other input and output voltages as well as longer overexcitation times are available on request! Page 3 of 6 3

Wiring Example (400 VAC, DC-side switching) Wiring Example (400 VAC, AC-side switching) L1 L2 L3 ROBA -multiswitch L1 L2 L3 ROBA -multiswitch + IN S DC OUT 5 6 + IN S DC OUT 5 6 5 6 5 6 M 3 ~ M 3 ~ Protection circuit When using DC-side switching, the coil must be protected by a suitable protection circuit according to VDE 0580, which is integrated in mayr -rectifiers. Nevertheless, the high voltage induced on circuit interruption produces switching sparks, which lead to contact consumption. Therefore, only use the main contacts of a contactor suitable for inductive loads with a minimum contact opening of 3 mm for switching the DC-side contact S DC. Connecting the main contacts in series reduces wear. Device Fuses To protect against damage from short-circuits or earth short-circuits, please add suitable device fuses to the mains cable. As an alternative, a motor protection switch can be used. This must be adjusted to the holding current of the brake; at the same time it serves as overload protection for the brake. Short-circuits or earth short-circuits can lead to ROBA -multiswitch failures. After fuse elements have reacted to a malfunction, the ROBA -multiswitch must be checked for functional and operational safety (overexcitation voltage, switch-off voltage, response delay time, holding voltage). The same procedure is to be carried out after coil failure. Switch- Switch-on always takes place AC-side, as only then is the overexcitation activated. Switch-OFF If short switching times are required, please switch DC-side. The AC-side should always be switched as well, in order to activate the overexcitation. If a longer brake engagement time or a quieter switching noise is required, please switch AC-side. For this, a bridge must be installed between terminals 3 and 4. Recovery Time 100 ms The recovery time is the amount of time the ROBA - multiswitch requires in order to reach its starting position after switch-off. Therefore, the device may be switched on again at the earliest after 100 ms. During cycle operation, please take suitable measures to ensure that the recovery time of 100 ms is maintained. Operation on Transformers During operation on a transformer, please ensure sufficient rigidity on transformers (min. 3x P N of the brake). A filter or external varistor must be installed. Please ensure that the standard EN 50160 is kept to and that this is re-checked after installation of the ROBA -multiswitch. 4 Page 4 of 6

Overexcitation Time t O Increased wear (enlarged air gap) as well as coil heat lengthen the brake separation time t 2. Therefore, when dimensioning the overexcitation time t O, please select at least double the separation time t 2 on each brake Type and size (catalogue values). The overexcitation time can be adjusted via the DIP switch to 150 ms, 450 ms, 1 s, 1.5 s and 2.15 s ± 20 %. The switches may only be switched in de-energised state and may only be adjusted as depicted. DIP switch Overexcitation time t O [s] 0.15 0.45 1.00 1.50 2.15 Manufacturer-side setting Coil Capacity If the switching frequency is larger than 1 cycle per minute or if the overexcitation time t O is longer than double the separation time t 2, please observe the following: P P N The coil capacity P must not be larger than P N or the nominal current I RMS which flows through the ROBA -multiswitch must not be exceeded, as otherwise the coil and the ROBA -multiswitch can fail due to thermal overload. At high input voltage and low brake performance, the initial bridge rectification of 50 ms can lead to thermic overload. Calculations: P P N P O P H [W] RMS coil capacity dependent on switching frequency, overexcitation, reduction in capacity and duty cycle P = P O x t O + P H x t H T [W] Coil nominal capacity (catalogue values, Type tag) [W] Coil capacity on overexcitation P O = ( )² x P N [W] Coil capacity at reduced capacity P H = ( )² x P N t O [s] Overexcitation time Time Diagram: U t O t on t H T t off t H [s] Time of operation with reduction in capacity t off [s] Time without voltage t on [s] Time with voltage T [s] Total time (t O + t H + t off ) I eff [V] Overexcitation voltage (bridge voltage) [V] Holding voltage (half-wave voltage) [V] Coil nominal voltage [A] RMS current dependent on switching frequency, overexcitation time and duty cycle 0 t I RMS = P x P N ² Page 5 of 6 5

EMC-compatible Installation The measure described for compliance with the EMC directive is examined under laboratory conditions, and cannot necessarily be bindingly transferred onto the condition of a machine or equipment in case of deviations. The inspection tests the individual components mayr -ROBA -multiswitch and the mayr -brake and is applicable for an input voltage of up to 500 VAC. Standards Product standard VDE 0160 / DIN EN 50178:1998-04 Electronic equipment for use in power installations EMC inspections EN 61000-6-2:2006-03 EN 61000-6-4:2007-09 Interference immunity Interference emission ROBA -multiswitch Insulation coordination acc. VDE 0110 / EN 60664:2008-01 Overvoltage category III Pollution degree 2 Rated insulation voltage 500 V RMS + IN S DC OUT 5 6 5 6 L1 L2 PE line filter Measure Installation of a line filter in the AC-supply line (e.g. Schaffner FN 2415-10-29) Avoid an antennae effect: Keep the supply cables as short as possible; do not form rings or loops with the cables! Mount good earth connections onto the metal body of the brake! Lay control cables separately from power cables or from strongly pulsating supply cables! During operation with a frequency converter, please ensure EMC-compatible installation of the frequency converter! Please always check the holding voltage of the ROBA -multiswitch during operation of all components in the system. For the operation of the ROBA -multiswitch in living and small business areas, special precautions must be taken in order to keep to the correct limit values for this area with the complete system, e.g. by installing a capacitor. The device has been inspected individually only for industrial areas. Intended Use mayr -rectifiers have been developed, manufactured and tested as electronic equipment in compliance with the DIN EN 50178 standard and in accordance with the EU Low Voltage Directive. During installation, operation and maintenance of the product, the requirements for the standard must be observed. mayr -rectifiers are for use in machines, systems and devices and must only be used in the situations for which they are ordered and confirmed. The products are designed for installation into electrical control cabinets and terminal boxes. Using them for any other purpose is not allowed. 6 Page 6 of 6