ECHOTEL 915 series. 2 Wire, current shift Ultrasonic level switch. Worldwide level and flow solutions DESCRIPTION. Compact and universal level switch

Echotel Model 961/962 Ultrasonic Level Switches

Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

Echotel Models 344/345 Ultrasonic Non-Contact Transmitters for Level, Volume, or Open Channel Flow

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S

ECHOTEL CONTACT ULTRASOUND. Worldwide Level and Flow Solutions SM

ECHOTEL 961. Ultrasonic level switches FOR HYGIENIC USE. Worldwide level and flow solutions. For LIQUID LEVEL switching applications

Thermatel Model TD1/TD2 Thermal Dispersion Flow/Level/Interface Switch

OPTIMASS 1000 Technical Datasheet

Echotel Model 355 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

The transducer component converts the measured signal and displays the actual value.

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

Ricochet Alphasonic Level Transmitter Model LA15 Owner s Manual

CAP ANALOG 410 INSTALLATION & OPERATION MANUAL

Non-Submersible Industrial Pressure Transducer

Horizon Model 704 Guided Wave Radar Level Transmitter

D E S C R I P T I O N F E A T U R E S A P P L I C A T I O N S. The Enhanced Jupiter Magnetostrictive level transmitter

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

Features. NULL-KOTE Circuitry Makes the sensor immune to adverse effects of conductive coating build up.

LST400 Ultrasonic level / open channel flow transmitter

Kotron Series 82 CE. Level. Transmitter. Installation and Operating Manual

Princo MagneLevel Model LML

Rosemount 3101, 3102, and 3105

Level Lance Model 5100

All TXI7850 products are ROHS compliant.

Eclipse Enhanced Model 705 GWR Level Transmitter for Hygienic Applications

Model T7800 Series Electro-Pneumatic I/P, E/P Transducer

Operating Principles

ECHOTEL 961/962 LINE POWERED

Electro-Magnetic Flowmeters COPA-XE

Fisher 646 Electro Pneumatic Transducer

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB

CS02 CAPACITANCE TRANSMITTER. Continuous Output Transmitter with Advanced Features INSTALLATION AND OPERATIONS MANUAL

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

ECHOTEL 961/962 LINE POWERED

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Fisher 646 Electro-Pneumatic Transducers

Metal tube variable area flowmeters for gases, liquids and steam

Eclipse Enhanced Model 705 GWR Level Transmitter for Hygienic Applications

Instruction Manual. HB Series Mini Level Sensor

Mid-West. Instrument. Model 142 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

2-wire level transmitter

IP26 Series Current to Pneumatic Converter

Technologies, Solutions, and Applications. Level Switching

MICRO SWITCH Electromechanical Safety Switches GSS Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

Flow Detection MDS Integral or Remote Housing FUNCTION TYPICAL USES. Microwave Doppler Switch Solids - Chute and Conveyor GHz Sender Receiver

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

LT3000 ULTRASONIC LEVEL TRANSMITTER

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Echotel Model 350/351

Magnetostrictive Level Transmitter

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Model Sono-Trak Transit Time

R.F. Capacitance Dual-Point Level Control INSTALLATION & OPERATION MANAUL

Spring Return DuraDrive Proportional Actuator

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview

Model R82 Pulse Burst Radar Level Transmitter

Global Water Instrumentation, Inc.

4.00 ULTRASONIC ANALYZER

Programmable K-Factor Scaler B and Programming Software Kit B

Level Measurement Continuous level measurement Radar transmitters

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

EchoSonic II Ultrasonic Level Transmitter LU27 Series Quick Start NEMA 4X Enclosure

Instruction Manual. Model MLA & MLD Loop Powered Process Indicators IM 61A01A-01E-A. Model MLA (Analog) Model MLD (Digital)

Installation Instructions Hustler Collinear Two Meter Fixed Station Antenna Master Gainer Model G6-144B

M2/M2A AC-DC Power Supply Operator s Manual

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Electromagnetic flowmeters and switches DWM 1000/2000

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB

FEATURES OPTIONAL FEATURES

Flow Detection MDS Integral or Remote Housing. Installation and Operating Instructions

LA-5000 SERIES LINEAR VALVE ACTUATORS

Flow Measurement SITRANS F M

KFS. Flap-type flow meter. Design and range of application

Level gauges Series LT Level indicator, switch and transmitter for liquids

Soliphant T FTM20, FTM21

Digital conductivity transmitter

Coriolis Massflowmeter

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

Design and applications

Ultrasonic Level Transmitter Model LU20 Owner s Manual

Process display RIA 261

CSIS CAPACITANCE TRANSMITTER. Intrinsically-Safe Continuous Output Level Transmitter INSTALLATION AND OPERATIONS MANUAL

Ultrasonic Level Transmitter Model LU30 Owner s Manual

Transcription:

Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit hub electronics houses a 10 amp DPDT gold flash relay that is field selectable for high or low level fail-safe applications. There are no moving parts that come in contact with the medium. The Echotel Model 910 is an integrally mounted system, comprised of surface mount electronics and a 316 stainless steel transducer. Hazardous area location approvals are available from FM, CSA, and ATEX. F E A T U R E S Measures level within 0.25" (6 mm) from the end of the tip-sensitive transducer gap 10 amp DPDT gold flash or 5 amp DPDT hermetically sealed relay Surface mount conformal coated electronics FM, CSA, and ATEX approved for hazardous locations Variety of mounting options including NPT and BSP threaded, flanges and sanitary connections No calibration required 316 stainless steel transducer May be mounted either horizontally or vertically Compact NEMA 4X/7/9 dual conduit hub cast aluminum electronics housing Available in 14 standard actuation lengths from 1" to 96" (2.5 to 244 cm) Two-year product warranty A P P L I C A T I O N S Water and wastewater Food and beverage Pulp and paper Petrochemical Power Pharmaceutical Chemical

T E C H N O L O G Y The Model 910 Level Switch uses ultrasonic energy to detect the presence or absence of liquid in a 316 SS tip sensitive transducer gap. The basic principle behind ultrasonic contact technology is that high-frequency sound waves are easily transmitted across a transducer gap in the presence of a liquid medium, but are severely attenuated when the gap is dry. The Model 910 uses an ultrasonic frequency of 3 MHz to perform this liquid level measurement in a wide variety of process media and application conditions. The transducer uses a pair of piezoelectric crystals that are encapsulated in epoxy at the tip of the transducer. The crystals are made of a ceramic material, such as lead zirconate. The transmit crystal converts an electrical signal from the Model 910 electronics into an ultrasonic signal. When liquid is present in the gap, the receive crystal is able to sense the ultrasonic signal from the transmit crystal and convert it back to an electrical signal. This signal is sent to the electronics to indicate the presence of liquid in the transducer gap. When there is no liquid present, the ultrasonic signal is attenuated, and the receive crystal is not able to sense the sound waves from the transmit crystal. Transmit crystal Ultrasonic signal transmission across transducer gap Ultrasonic transducer Receive crystal High alarm Low alarm Filling line High alarm Low alarm Pump protection Pump Typical applications and mounting positions 2

S W I T C H M O D E L N U M B E R Models available for quick shipment, usually within one week after factory receipt of a purchase order, through the Expedite Ship Plan (ESP) HOUSING A Aluminum sand cast with 3 4" NPT dual conduit, FM and CSA approvals Y 316 stainless steel with 3 4" NPT single conduit, FM and CSA approvals P Aluminum sand cast with 3 4" NPT dual conduit, FM and CSA approvals 5 316 stainless steel with 3 4" NPT single conduit, ATEX approval TRANSDUCER UNIT OF LENGTH 1 English (actuation length in inches) M Metric (actuation length in centimeters) PROCESS CONNECTION A 3 4" NPT 2 1" NPT 9 1" BSP 3 1 1 2" sanitary flange (Compatible with Tri-Clover Tri-Clamp fittings.) 4 2" sanitary flange (Compatible with Tri-Clover Tri-Clamp fittings.) 1 1" 150 lb. ASME raised face flange C 1 1 2" 150 lb. ASME raised face flange D 2" 150 lb. ASME raised face flange E 1" 300 lb. ASME raised face flange F 1 1 2" 300 lb. ASME raised face flange G 2" 300 lb. ASME raised face flange INPUT POWER 0 120 VAC with 10 amp DPDT gold flash relay 1 240 VAC with 10 amp DPDT gold flash relay 2 24 VDC with 10 amp DPDT gold flash relay H 120 VAC with 5 amp DPDT hermetically sealed relay J 240 VAC with 5 amp DPDT hermetically sealed relay K 24 VDC with 5 amp DPDT hermetically sealed relay ACTUATION LENGTH 1" to 96" in 1" increments (with Transducer Unit of Length code 1) Example: 4 inches = 004 ➀ ➂ 3 cm to 244 cm in 1 cm increments (with Transducer Unit of Length code M) Examples: 6 centimeters = 006 ➁ ➂ Available ESP lengths ➃ : 1", 4", 6", 8", 10", 16", 22", 48" 9 1 0 ➀ 1" (code 001) minimum with NPT process connections, 2" (code 002) minimum with sanitary or ASME flanged process connections ➁ 2.5 cm (code 003) minimum with NPT process connections, 5 cm (code 005) minimum with 1" BSP, or sanitary or ASME flanged process connections. ➂ Consult factory for longer lengths ➃ Consult factory for ESP metric length codes. 3

D I M E N S I O N A L S P E C I F I C A T I O N S I N C H E S ( M M ) 6.25 (158) 3.00 Rotation (76) clearance Optional mounting flange 3.50 (88) plugged 6.25 (158) 3.44 (87) Rotation clearance Optional mounting flange 3.50 (88) tank connection Actuation length ➀➁ tank connection Actuation length ➀➁ NEMA 4X/7/9, 316 stainless steel housing 3 4" NPT single conduit NEMA 4X/7/9, aluminum sand cast housing 3 4" NPT dual conduits plugged 6.25 (158) 3.44 (87) Rotation clearance (plugged) 3.44 (87) Rotation clearance 1" BSP tank connection Actuation length ➁ Actuation length ➀ ➁ NEMA 4X/7/9, aluminum sand cast housing 3 4" NPT dual conduit (w/1" BSP process connection) NEMA 4X/7/9, aluminum sand cast housing 3 4" NPT dual conduit (with sanitary flange) ➀ 1" minimum with NPT threaded process connections. 2" minimum with sanitary or ASME flanged process connections. ➁ 25 mm minimum with NPT threaded process connections. 50 mm minimum with 1" BSP and sanitary or ASME flanged process connections. 4

E L E C T R I C A L S P E C I F I C A T I O N S Power Supply: 120 VAC (+10%/-15%), 50/60 Hz 240 VAC (+10%/-15%), 50/60 Hz 24 VDC (±10%) Power Consumption: 2.5 VA nominal Relay Output: Gold flash DPDT➀: 10 amps @ 120 VAC, 10 amps @ 240 VAC 10 amps @ 24 VDC, 0.5 amps @ 125 VDC Hermetically sealed DPDT: 5 amps @ 120 VAC, 5 amps @ 240 VAC 5 amps @ 24 VDC Repeatability: 0.078" (2 mm) Fail-safe: Field selectable high or low Calibration: None required Ambient Temperature: Electronics: -40 to +160 F (-40 to +71 C) ➁ Process Temperature: Transducer: -40 to +250 F (-40 to +121 C) Operating/Non-Operating Pressure: 800/1500 psig (55/103 bar) ➀ Gold flash DPDT relay is rated at 8 amps when used with housing codes 5 or P ➁ Electronics are rated -40 to +104 F (-40 to +40 C) with the ATEX housing code 5 A G E N C Y A P P R O V A L S AGENCY MODEL APPROVED APPROVAL CATEGORY APPROVAL CLASSES FM 910-XXXX-XXX Explosion Proof Class I, Div. 1; Groups C & D Class II, Div. 1; Groups E, F, & G Class III, NEMA Type 4X, T6 910-XXXX-XXX Non-Incendive Class I, Div. 2; Groups A, B, C, & D Class II, Div. 2; Groups F & G Class III, NEMA Type 4X, T5 CSA 910-XXXX-XXX Explosion Proof Class I, Div. 1; Groups C & D Class II, Div. 1; Group E, F, & G Class III, Type 4X, T6 910-XXXX-XXX Non-Incendive Class I, Div. 2; Groups A, B, C, & D Class II, Div. 2; Groups E, F, & G Class III, Type 4X, T5 ATEX 910-5XXX-XXX II 1 2 G EEx d II C T6 / EEx e II T6 These units have been tested to EN 50081-2 and EN 50082-2 and are in compliance with the EMC Directive 89/336/EEC. 5

Q U A L I T Y The quality assurance system in place at Magnetrol guarantees the highest level of quality throughout the company. Magnetrol is committed to providing full customer satisfaction both in quality products and quality service. Magnetrol s quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product/service quality available. E S P Expedite Ship Plan Several Echotel Model 910 Ultrasonic Level Switches are available for quick shipment, usually within one week after factory receipt of a purchase order, through the Expedite Ship Plan (ESP). Models covered by ESP service are conveniently color coded in the selection data charts. To take advantage of ESP, simply match the color coded model number codes (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options. Q U A L I T Y All Magnetrol Model 910 Level Switches are warranted free of defects in materials or workmanship for two full years from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Magnetrol will repair or replace the control at no cost to the purchaser (or owner) other than transportation. Magnetrol shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Magnetrol products. For additional information, see Instruction Manual 51-604. BULLETIN: 51-105.12 EFFECTIVE: January 2004 SUPERSEDES: September 2000