The AT4222 module is equipped with four inputs for PT100/PT1000 resistance temperature measurement.

Similar documents
The DO8332 module is equipped with eight outputs for 1-wire connections. The rated output current is 2 A.

X20(c)AI General information. 2 Coated modules. 3 Order data. X20(c)AI4622

7.2 DV1311.L08 and DV1311.L12

X20(c)DO2633. Danger! 1 General information. 2 Coated modules. X20(c)DO2633

X20SM General information. 2 Order data X20SM1436

VersaPoint I/O Module

VersaPoint I/O Module

X20CP1301, X20CP1381 and X20CP1382

CAN-IO Custom IO remote module

VARIO RTD 2. Function. I/O Extension Module With Two Analog Input Channels for the Connection of Temperature Shunts (RTD) User Manual

IB ST (ZF) 24 PT 100 4/4

8V General information. 2 Order data 8V

IB IL TEMP 2 UTH. Function. INTERBUS Inline Terminal With Two Analog Input Channels for Measuring Temperature. Data Sheet 5722B

AM 441 S-DIAS Analog Mixed Module ±10 V

PHOENIX CONTACT - 01/2007

UniStream Uni-I/O Modules

PHOENIX CONTACT - 03/2007

WIRELESS MODBUS GATEWAY WGW410

IB IL AI 8/IS IB IL AI 8/IS-PAC

This data sheet is only valid in association with the IL SYS INST UM E user manual.

DM 162 S-DIAS Digital Mixed Module

OUTPUT 5/24 VDC PWM/PT 2 CHANNEL. 1 Description. GFK-2761 May 2012

IB IL AI 2/SF. Function. INTERBUS Inline Terminal With Two Analog Input Channels. Data Sheet 5564A

IB IL TEMP 2 RTD (-PAC)

IB IL AO 1/U/SF. Function. INTERBUS Inline Terminal With One Analog Voltage Output. Data Sheet 5736CC01

10 Error Code List. Motion Control SW. NTI AG / LinMot User Manual Motion Control SW/ Page 87/94

AI 043 S-DIAS Analog Input Module

General specifications and features

SLC 500 RTD/Resistance Input Modules

8V General information. 2 Order data 8V

S200 I/O System Units

Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) SIMATIC. ET 200SP Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) Preface. Documentation guide 1

on-board EEPROM, are incorporated for automatic zero point and full-scale alignment.

Temperature Input Module for Zone 1 Series 9482/32

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

PACSystems* RX3i IC695MDL765

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

Data sheet CPU 314ST/DPM (314-6CF02)

em4 local - Robust Specific characteristics Part number

Programming restrictions when operating SM 331; AI 8 x RTD with PROFIBUS masters which only support DPV0.

maxon document number:

Q.raxx A101-8 slimline RS / EC

I-7088, I-7088D, M-7088 and M-7088D User Manual

58V signal frequency input analog input ( ma, PT1000. sensor) Programming System

Temperature controller, 4-channel

UniStream Built-in. Technical Specifications US7-B5-RA28, US7-B10-RA28 US7-B5-TA30, US7-B10-TA30

Process displays For standard signals, temperature, resistance measurement

em4 em4 alert em4 alert 2G

Q.raxx A slimline RS / EC Multi Channel System for Thermocouples

Table of Contents. HWIO-Gateway User Manual

6.6 Analog input module SM 331; AI 8 x 13 Bit; (6ES7331-1KF02-0AB0)

IP-OptoAD16. Opto-Isolated 16-bit A/D Conversion IndustryPack. User s Manual

UniStream 5" Technical Specifications US5-B5-RA28, US5-B10-RA28

VersaMax Mixed Discrete / High-Speed Counter Module

Assembly. Front view. Parametrization interface. Power Bus

Q.raxx A slimline RS / EC

Digital Input Output Module for Zone 2 Series 9470/33

MRS ELECTRONIC DATASHEET CAN I/O AND PLC DESCRIPTION TECHNICAL DATA REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

DIGEM f 96 x 48 EK. Applications. Description

POINTAX 6000L2 Point Recorder

Analog input module AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1) SIMATIC. ET 200SP Analog input module AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1) Preface

PAM & SAM System User s Manual

IB IL TEMP 4/8 RTD/EF...

02/11/2015

IBS IP CDIO/R 24-8 IBS IP CDIO/R 24-8/SF

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

PACSystems* RX3i IC695ALG600

INFO-PTr. PT-100 Measuring Card. PT-100 Temperature Measurement. Technical Data

02/11/2015

02/11/2015

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

imc CANSAS-L-HCI8. High isolated module for the capture of temperature, voltage, current (20 ma) and resistance

PACSystems* RX3i and Series 90-30

Data sheet CPU 313SC (313-5BF13)

SIMATIC. ET 200SP Analog Input Module AI 4xI 2-/4-wire ST (6ES7134-6GD01-0BA1) Preface. Documentation guide. Product overview.

MN5020HS Smart GPS Antenna Module

This Errata Sheet contains corrections or changes made after the publication of this manual.

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

PACSystems* RX3i IC695ALG600-EE Universal Analog Input Module

PACSystems* RX3i IC695ALG600-DD

M70LL Laser Distance Sensor

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Data sheet CPU 013C (013-CCF0R00)

GE Fanuc IC695ALG600. Rx3i PacSystem

VersaMax* Analog Input, 16-Bit RTD Module

VersaMax Mixed Discrete / High-Speed Counter Module

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolating Repeater Input Series 9163

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

USB-2404-UI Specifications

Data sheet VIPA CPU 314SC DPM (314-6CG23)

Photoelectric Sensors. Manual. True-Color-Sensor with IO-Link. Document number: E Edition C15 Subject to changes.

I-8060 I-8060-G. 6-channel Relay Output Module. I/O Specifications. System Specifications

CompactLogix 5370 L3 Control System

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

SIMATIC. ET 200SP Analog Input Module AI 4xU/I 2-wire ST (6ES7134-6HD01-0BA1) Preface. Documentation guide. Product overview.

Digital Input Output Module for Zone 1 Series 9470/32

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

Transcription:

22.3 AT4222 22.3.1 General information The AT4222 module is equipped with four inputs for PT100/PT1000 resistance temperature measurement. 4 inputs for resistance temperature measurement For PT100 and PT1000 Sensor type can be be set for each channel Direct resistance measurement as well 2 or 3 wire connection can be configured for each module Filter time can be configured 22.3.2 Order data Model number Short description Figure Temperature module X20AT4222 X20 temperature input module, 4 resistance measurement inputs, PT100, PT1000, resolution 0.1 K, 3-wire connections X20TB12 X20BM11 Required accessories X20 terminal block, 12-pin, 24 V coded X20 bus module, 24 V coded, internal I/O supply is interconnected Table 529: AT4222 - Order data 858

22.3.3 Technical data Product ID Short description I/O module Temperature inputs - Resistance measurement Input Digital converter resolution Filter time Conversion time 1 channel 2-4 channels Output format Maximum error at 25 C Gain Offset Sensor PT100 PT1000 Resistance measurement range General information Status indicators Diagnostics Module run/error Inputs Electrical isolation Channel - Bus Channel - Channel Power consumption Bus I/O internal Certification Operating conditions Operating temperature Horizontal installation Vertical installation Relative humidity Mounting orientation Installation at altitudes above sea level 0-2000 m >2000 m Protection type AT4222 4 inputs for PT100 or PT1000 resistance temperature measurement Resistance measurement with constant current supply for 2 or 3-wire connections 16-bit Configurable between 1 ms and 66.7 ms 20 ms at 50 Hz filter 40 ms per channel with 50 Hz filter INT or UINT for resistance measurement 0.037%, based on the current resistance value 0.0015%, based on the entire resistance range Can be set per channel -200 C to +850 C -200 C to +850 C 0.1 to 4500 0.05 to 2250 I/O function per channel, operating state, module status Yes, with status LED and software status Yes, with status LED and software status Yes No 0.01 W 1.1 W CE, C-UL-US, GOST-R 0 C to +55 C 0 C to +50 C 5 to 95%, non-condensing Horizontal or vertical No derating Reduction of ambient temperature by 0.5 C per 100 m IP20 Chapter 4 X20 module Table 530: AT4222 - Technical data 859

Product ID Storage and transport conditions Temperature Relative humidity Mechanical characteristics Spacing Comment AT4222-25 C to +70 C 5 to 95%, non-condensing 12.5 +0.2 mm Order terminal block 1x X20TB12 separately Order bus module 1x X20BM11 separately 22.3.4 Additional technical data Table 530: AT4222 - Technical data (cont.) Product ID Temperature inputs - Resistance measurement AT4222 Sensor standard IEC/EN 60751 Temperature sensor resolution PT100 PT1000 Resistance measurement resolution G = 1 G = 2 Temperature sensor standardization PT100 PT1000 Standardized value range for resistance measurement G = 1 G = 2 Temperature measurement monitoring Open inputs Wire break Below lower range limit Above upper range limit General error Resistance measurement monitoring Open inputs Wire break Above upper range limit General error Conversion method Linearization method 1 LSB = 0.1 C 1 LSB = 0.1 C 0.1 0.05-200.0 C to +850.0 C -200.0 C to +850.0 C 0.1 to 4500.0 0.05 to 2250.0 $7FFF $7FFF $8001 $7FFF $8000 $FFFF $FFFF $FFFF $FFFF psigma Delta Internal Reference 4530 ±0.1% Measuring current 250 µa ±1.25% Permitted input signal Short-term max. ±30 V Input filter Low pass 1st order / cut-off frequency 500 Hz Maximum gain drift 0.004%/ C, based on the current resistance measurement Table 531: AT4322 - Additional technical data 860

Product ID Maximum offset drift Common-mode rejection DC 50 Hz Synchronized zone Cross-talk between channels Non-linearity Isolation voltage betw. channel and bus General information B&R ID code AT4222 0.00015%/ C, based on the entire resistance measurement range >95 db >80 db >0.7 V >93 db <0.0010%, based on the entire resistance range 500 V eff $1BA7 Table 531: AT4322 - Additional technical data (cont.) 22.3.5 Status LEDs Figure LED Color Status Description r Green Off Module supply not connected Single flash Reset mode Blinking Preoperational mode On RUN mode e Red Off Module supply not connected or everything is OK On Error or reset state Single flash Warning/error for an I/O channel. Overflow or underflow of the analog inputs. e + r Steady red / single green flash Invalid firmware 1-4 Green Off The input is switched off Blinking Overflow, underflow or broken connection On The analog/digital converter is running, value is OK Chapter 4 X20 module Table 532: AT4222 - Status indicators 861

22.3.6 Pin assignments Channels that are not being used should be deactivated. X20 AT 4222 r e 1 2 3 4 Sensor + 1 Sense - 1 Sensor - 1 Sensor DI 1+ 3 Geber Sense 1 24V+ - 3 Sensor GND- 3 Sensor + 2 Sense - 2 Sensor - 2 Sensor DI 2+ 4 Geber Sense 2 24V+ - 4 Sensor GND- 4 Figure 399: AT4222 - Pin assignments 22.3.7 Connection example 3-wire connection AT 2-wire connection Sensor 1 + + Sensor 2 Sensor 3 + + Sensor 4 +24 VDC GND +24 VDC GND Figure 400: AT4222 - Connection example 862

22.3.8 Input circuit diagram 2-line connection 250 µa Sensor + x Channel 2-4 Channel 1 Sense - x Channel 2-4 Channel 1 Multiplexer A/D converter Input value I/O status Switch closed when 2-wire connection LED (green) Figure 401: AT4222 - Input circuit diagram - 2-wire connection 3-line connection Sensor + x 250 µa 250 µa Channel 2-4 Channel 1 Chapter 4 X20 module Sense - x Sensor - x PTC Channel 2-4 Channel 1 Multiplexer A/D converter Input value I/O status LED (green) Figure 402: AT4222 - Input circuit diagram - 3-wire connection 863

22.3.9 Analog inputs The converted analog values are output by the module in the registers. Different resistance or temperature measurements will result in different value ranges and data types. 22.3.10 Timing setting The timing setting for data acquisition is made using the converter hardware. All switched on inputs are converted during each conversion cycle. 22.3.11 Conversion time The conversion time for the channels depends on their use. For the formulas listed in the table, 'n' corresponds to the number of channels that are switched on. Channel uses 1 channel n channels with the same sensor type n channels with different sensor types Conversion time 1 FilterTime n 20ms + FilterTime n 20ms + 2 FilterTime 22.3.12 Reduced refresh time If an input is not necessary, it can be switched off, thereby reducing the refresh time. Inputs can also be only temporarily switched off. Calculating the time saved The amount of time saved can be calculated with the following formula. And 'n' corresponds to the number of inputs that are switched off. TimeSaved = n 20ms + FilterTime Examples The inputs are filtered using a 60 Hz filter. Example 1 Example 2 Example 3 Switched on inputs 1 1, 3 1-4 Conversion time 16.7 ms 73.4 ms 146.8 ms 864

22.3.13 Input filter The filter time for all analog inputs is defined using the input filter parameter. Value Filter Filter time Digital converter resolution 0 15 Hz 66.7 ms 16-bit 1 25 Hz 40 ms 16-bit 2 30 Hz 33.3 ms 16-bit 3 50 Hz 20 ms 16-bit 4 60 Hz 16.7 ms 16-bit 5 100 Hz 10 ms 16-bit 6 500 Hz 2 ms 16-bit 7 1000 Hz 1 ms 16-bit 22.3.14 Sensor type and channel deactivation The module is designed for temperature and resistance measurement. The sensor type must be specified because of the different adjustment values for temperature and resistance. The default setting for all channels is ON. To save time, individual channels can be switched off (see section 22.3.12 "Reduced refresh time" on page 864). Code Input signal 0 Reserved 1 Reserved 2 Sensor type PT100 3 Sensor type PT1000 4 Reserved 5 Resistance measurement 0.1 to 4500 6 Resistance measurement 0.05 to 2250 7 Channel turned off Chapter 4 X20 module 865

22.3.15 Input status The module's inputs are monitored. A change in the monitoring status generates an error message. Code Channel x 0 No error 1 Below lower limit value 2 Above upper limit value 3 Wire break 22.3.16 "StatusInput01" register Bit Description 0-1 Channel 1: 00... No error 01... Below lower limit value 10... Above upper limit value 11... Wire break 2-3 Channel 2: 00... No error 01... Below lower limit value 10... Above upper limit value 11... Wire break 4-5 Channel 3: 00... No error 01... Below lower limit value 10... Above upper limit value 11... Wire break 6-7 Channel 4: 00... No error 01... Below lower limit value 10... Above upper limit value 11... Wire break In addition to the status info, the error type also sets the analog value to the following values: Error type Temperature measurement Digital value for error Resistance measurement Digital value for error Wire break +32767 ($7FFF) 65535 ($FFFF) Above upper limit value +32767 ($7FFF) 65535 ($FFFF) Below lower limit value -32767 ($8001) 0 ($0000) Invalid value -32768 ($8000) 65535 ($FFFF) 866

22.3.17 IOCyclicCounter The cyclic counter increases after all input data have been updated. 22.3.18 B&R ID code Code for module identification ($1BA7). 22.3.19 Minimum cycle time The minimum cycle time is the minimum time needed for the bus cycle to be shut down without a communication error or malfunction occurring. It should be noted that very fast cycles reduce the idle time needed for handling monitoring, diagnostics and acyclic commands. Minimum cycle time In each operating mode 100 µs 22.3.20 Minimum I/O update time The minimum I/O update time refers to the minimum time it takes for the bus cycle to shut down, so that in each cycle an I/O update takes place. Minimum I/O update time 1 input Equal to the filter time n inputs n 20ms + FilterTime Chapter 4 X20 module 867