Similar documents
E MC Ane c hoi c Chambers

Semi Anechoic Chamber (SAC)

SAC-10 Plus Triton Class

Normalized Site Attenuation Test Report

ETS Lindgren Anechoic Chamber

The Important Points for Determining the Requirements of EMC Chambers

Model BiConiLog Antenna. User Manual

Double-Ridged Waveguide Horn

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

Fully Anechoic Room Validation Measurements to CENELEC pren

Proposed TDR Method for Site Validation Above 1 GHz

EMC Test Facility Sale

Double-Ridged Waveguide Horn Antennas

Electromagnetic Compatibility ( EMC )

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

On The Design of Door-Less Access Passages to Shielded Enclosures

Large E Field Generators in Semi-anechoic Chambers for Full Vehicle Immunity Testing

Reverberation Chambers Design and Construction Considerations for Aerospace and Military Test Requirements

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

Certificate of Conformity

Test and Measurement for EMC

For EMC testing and EMC compliance/ For antenna design and evaluation/multi-functional types

Polyurethane foam technology Carbon for broadband absorption MLT for hybrid absorbers Over twenty years of performance

Design of Modern EMC Chambers for Radiated EMC Testing up to 18 GHz

Log Periodic Dipole Array Antenna

Double-Ridged Waveguide Horn

EMC SHIELDING EFFECTIVENESS TEST REPORT : : :

Report Of. Shielding Effectiveness Test For. DefenderShield. Test Date(s): September 1 October 2, 2012

Client Archive No.: - / - 1 Summary: Table of results: shielding effectiveness measurement: References:...

Testing for Radiated Emission by Electronic Devices

Loop & Magnetic Field Coil

Accredited Standards Committee C63 - EMC

Model 3140B BiConiLog Antenna User Manual

NSA Calculation of Anechoic Chamber Using Method of Moment

Model 3180B Mini-Bicon Antenna User Manual

Physically and Electrically Large Antennas for Antenna Pattern Measurements and Radar Cross Section Measurements in the Upper VHF and UHF bands

Selecting the right antenna for the

AMPLIFIER RESEARCH... APPLICATION NOTE: 20

Electromagnetic Compatibility Test Report

Sunlight Supply, Inc.

RADIOMETRICS Midwest Corporation

FREQUENCY SHIELDING EFFECTIVENESS TEST REPORT TEST REPORT NUMBER TR-TRU-PROTECT-M

AMPLIFIER RESEARCH... APPLICATION NOTE: 23

Contents. EH-H21/12 Page 2 of 38

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

Alternative Radiated Emission Test Methods Progress Achieved in IND60 Project

Automotive standards addressing electromagnetic

TEST REPORT... 1 CONTENT...

Electromagnetic Effects, original release, dated 31 October Contents: 17 page document plus 13 Figures. Enclosure (1)

Reverberation Chambers

US Council of EMC Laboratories [USCEL] Technical Issues having Significant Cost Implications for EMC Laboratory Owners/Operators

Shielding Effectiveness Summary Results for RadiaShield Technologies, Inc. RadiaShield Fabric

West Michigan IEEE EMC Chapter Meeting

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Laird Attn: Bill Steinike W66 N220 Commerce Ct. Cedarburg, WI Report Constructed by: Zach Wilson, EMC Technician Signature: Date: June 21, 2017

GTEM cells. Emissions and immunity testing in a single, shielded environment

RADIO TEST REPORT. For MODEL NO FCC ID: C3K1703 IC ID: 3048A Test Report No. R-TR190-FCCIC-UNII-1 Issue Date: 14 September 2015

MEASUREMENT REPORT FCC Part 15B

Advanced Test Equipment Rentals ATEC (2832)

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

A GTEM BEST PRACTICE GUIDE APPLYING IEC TO THE USE OF GTEM CELLS

Measurement of RF Interference from a Canopy 900MHz Access Point and Subscriber Module Using A Yagi Antenna

Further Refining and Validation of RF Absorber Approximation Equations for Anechoic Chamber Predictions

EMC SHIELDING EFFECTIVENESS TEST REPORT : : :

Archived 3/18/10 USER MANUAL EMCO MODEL 3141 BICONILOG TM LOG-PERIODIC / T BOW-TIE ANTENNA Rev A 01/97

EMC SHIELDING EFFECTIVENESS TEST REPORT : : :

LTE Band 7. Channel

First choice for EMC Testing. EMC Testing Product Brochure

We re In The Business Of Making Your Life Easier

Specification for Conducted Emission Test

RF Shielded rooms. Controlled Electromagnetic Environments

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations

AMPLIFIER RESEARCH... APPLICATION NOTE: 19

EMC SHIELDING EFFECTIVENESS TEST REPORT : : :


Advanced Compliance Solutions, Inc FAU Blvd, Suite 310 Boca Raton, Florida (561)

Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,

Specification for Radiated susceptibility Test

Test sites for EMC measurements

STC Test Report. The Hong Kong Standards and Testing Centre Ltd.

8370 Court Avenue, Suite B-1 Ellicott City, Maryland (410) FCC CERTIFICATION

Electrical Field Distribution*

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

FCC Test Report. Report No.: AGC FE08. Attestation of Global Compliance (Shenzhen) Co., Ltd

Quality Auditing Institute # Schoolhouse Street, Coquitlam, BC, V3K 4X9, Canada. ISO Accreditation:

FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR

TABLE OF CONTENTS. Report No.: SH E03 1. TEST RESULT CERTIFICATION...3

Main features. System configurations. I Compact Range SOLUTION FOR

ANSI C Testing unintentional emitters

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

No. 620 HuaYuan Commercial Center, No. 347 XiXiang Road,XiXiang Town, Bao An District, ShenZhen City Tel : Fax:

Saturation of Active Loop Antennas

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...

MEASUREMENT REPORT FCC Part 15B

Certification Test Report

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

CHARACTERISATION OF IN -HOUSE EMC TESTING FACILITIES FOR PRODUCT DESIGNERS. Paul Kay* and Andrew Nafalski**

The NASA High Intensity Radiated Fields Laboratory. Reuben A. Williams. NASA Langley Research Center M/S 130 Hampton, Virginia

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

Transcription:

ETS-Lindgren's FACT 5 Chambers offer semi-anechoic radiated emissions (RE) and fully anechoic radiated immunity (RI) compliance test capability for most international EMC compliance regulations. FACT 5 Chambers offer the ability to perform RE testing at a 5-meter distance while preserving the ability to perform full compliance testing of applicable 3-meter standards. Results obtained with 5-meter distance have better correlation to those obtained at a 10-meter distance than the ones measured at 3-meter distance. ETS-Lindgren FACT 5 chambers achieve their broadband performance using a unique arrangement of hybrid and ferrite tile absorber. The design was modeled using the proprietary numerical electromagnetic software responsible for creating chambers that set new standards for anechoic performance. MODEL FACT 5 26 MHz to 40 GHz Frequency Range Full Compliance Testing for Radiated Emissions: ANSI C63.4 FCC Parts 15 and 18 EN 50147-2 CISPR 11 / EN55011 CISPR 16 / EN55016 CISPR 22 / EN55022 CISPR 32 / EN55032 VCCI V-3 / 2003.04 SAE J551 SAE J1113 (Requires Chamber Modification to Accommodate Full Vehicle) Full Compliance Testing for Radiated Immunity: IEC 61000-4-3 / EN61000-4-3 SAE J551 SAE J1113 Elgible for FCC 3m Class B Facility Filing Available NSA Options (May Require Chamber Modifications): Standard ± 4.0 db Standard Plus ± 3.5 db Premium ± 3.0 db Available as a Turnkey Package: Chamber Tower Turntable Antennas Instrumentation Software Radiated Emissions Testing ETS-Lindgren s FACT 5 chambers are designed to provide customers with more standardized solutions for different quiet zone diameters and performance options. This will provide users more flexibility to choose which solution works best for their individual needs. The available quiet zone sizes are available up to 3.0 meters in diameter. ETS-Lindgren s FACT 5 chambers can be used to perform full compliance testing for ANSI C63.4, FCC Parts 15 and 18, EN 50147-2, CISPR 11 / EN 55011, CISPR 16 / EN55016, CISPR 22 / EN55022, CISPR 32 / EN55032, VCCI V-3/2003.04, SAE J551 and SAE J1113. ETS-Lindgren guarantees that the performance of Normalized Site Attenuation (NSA) testing according to ANSI C63.4 with 5-meter test distance, is ± 4.0 db for STANDARD chamber, ± 3.5 db for STANDARD PLUS chamber and ± 3.0 db for PREMIUM chamber over the frequency range of 30 MHz to 1 GHz. The guaranteed performance for Site VSWR (svswr) test per CISPR 16-1-4 (ANSI C63.4) for frequency range of 1 GHz to 18 GHz is < 6.0 db, regardless which performance option is selected below 1 GHz. Radiated Immunity Testing ETS-Lindgren s FACT 5 chambers can also be used to perform full compliance testing for IEC 61000-4-3/ EN61000-4-3, SAE J-551 requirements. At 3-meter test distance lengths, Field Uniformity (FU) of 0-6 db can be achieved over the frequency range of 26 MHz to 18 GHz. The test aperture for FU is a vertical plane of 1.5 m x 1.5 m at an elevation of 0.8 m to 2.3 m above the ground plane, following the field uniformity test procedure of IEC 61000-4-3. Additionally, used absorber material can safely withstand continuous field intensity of up to 200 V/m and intermittent field intensity of up to 500 V/m. This safely exceeds the field intensity requirements of commercial RI tests. Optional Turnkey Systems ETS-Lindgren can supply a fully integrated test system for your needs and with ETS-Lindgren, there s no need to deal with multiple vendors or incompatible hardware issues. With ETS-Lindgren, you work alongside a single, accountable partner with a proven track record of success. At systems level, our integrated RF measurement solutions are specifically designed to meet the requirements of a particular test standards. Our objective is always the same when we are designing the test system: listen carefully to our client s requirements, and then respond with proven solutions that minimize risk and assure success.

Baseline Configuration Design and Fabricate RF-shielded Enclosure Installation of the Enclosure and Absorber One Single-leaf, manually operated, RF-shielded Personnel Door Raised, Reflective Ground Plane Access Hatches in Raised Floor, Nominally 30 cm (12 in) x 30 cm (12 in) Waveguide Vents, Nominally 30 cm (12 in) x 30 cm (12 in) 50/60 Hz Power-line Filters for EUT, Lights, Antenna Tower and Turntable Connector Panels, Nominally 15 cm (6 in) x 60 cm (24 in) Clear Opening Pipe Penetration Fiber Optic ST-type Feed-through Kits for Antenna Tower and Turntable RF-shielded Penetration for Airline to Antenna Tower (Compressed Air is Responsibility of Customer) Corner-mounted Light Fixtures with Floodlights (Electrical Distribution not Included in All Markets) Shielding Effectiveness Test at 1 GHz with the Test Methods of MIL-STD-285/IEEE-299 FerroSorb Hybrid Absorber Light Reflective Finish on the Walls and Ceiling FerroSorb Hybrid Floor Absorber on Sixteen (16) Movable Carts for Immunity Testing EHP Microwave Floor Absorber for an Area of the Floor for svswr Testing ETS-Lindgren Electrically Powered Turntable ETS-Lindgren Dual Device Controller ETS-Lindgren Bore-sight Antenna Tower; Electrically Powered and Air Polarization Warranty as per ETS-Lindgren s Standard Warranty for Anechoic Chambers and Associated Equipment Options Fully Integrated Test System to Meet the Requirements Of A Particular Test Standard Shielded Control Room Shielded Amplifier Room Model LDT-1.5 Low Dielectric Table 30 cm (12 in) and 45 cm (18 in) Raised Floors Low Profile Door Sill Sliding Door CCTV Monitoring System Intercom System Fire Detection And Suppression System Other Door Options Available Anti-static Vinyl Floor Tile Additional RF Filtering Company Logo Screen Printed Onto White Caps Immunity Interlock Switch Electrical Distribution Heating, Ventilation, And Air Conditioning (HVAC) System Seismic Structural Design Calculations And Certification Chamber Acceptance Testing Options FU Test per IEC 61000-4-3 From 80 MHz to 1 GHz FU Test per IEC 61000-4-3 From 1 GHz to 18 GHz NSA Test (3-meter) per ANSI C63.4/CISPR 16-1-4 From 30 MHz to 1 GHz NSA Test (5-meter) per ANSI C63.4/CISPR 16-1-4 From 30 MHz to 1 GHz svswr Test per CISPR 16-1-4/ANSI C63.4 From 1 GHz to 18 GHz

Technical Specifications (2.0 Standard Plus) Quiet Zone Normalized Site Attenuation (NSA) Antenna Scan Limits Site Voltage Standing Wave Ratio (svswr) Field Uniorminty (FU) Physical (2.0 Standard Plus) Nominal Internal Shield Length 1 Nominal Internal Shield Width 1 Nominal Internal Shield Height 1 (3.0 Standard Plus) Normalized Site Attenuation (NSA) Antenna Scan Limits Site Voltage Standing Wave Ratio (svswr) Field Uniorminty (FU) Physical (3.0 Standard Plus) Nominal Internal Shield Length 1 Nominal Internal Shield Width 1 Nominal Internal Shield Height 1 2-meter ± 3.5 db 1 4 m < 6 db 0 to 6 db (75% Points) 10.7 m 35.0 ft 6.7 m 22.0 ft 5.8 m 18.5 ft 3-meter ± 3.5 db 1 4 m 0 to 6 db (75% Points) 11.6 m 38.0 ft 7.3 m 24.0 ft 7.3 m 18.5 ft 1 Dimensions shown are typical. External dimensions will vary with shielding type and structural support requirements.

Measured svswr Deviation (3-meter), 1 GHz to 18 GHz Measured NSA Deviation (3m), 30 MHz to 1 GHz Measured NSA Deviation (5-meter), 30 MHz to 1 GHz

Measured Field Unifomity (Horizontal) Measured Field Unifomity (Vertical) Information presented is subject to change as product enhancements are made. Contact ETS-Lindgren Sales Department for current specifications. 6/15 - PDF/RR 2015 ETS-Lindgren v1.0