CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

Similar documents
600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables

CIR (Crush & Impact Resistant) VFD Power Cable

SIMpull THHN, it slips and slides - all with NoLube.

14 AWG 2 AWG: 600 Volt

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

THHN12STGN500 THHN 12 STR Green 500

THHN2BK2500 THHN 2 STR Black 2500

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500

A. Product Description: Stranded conductor insulated wire.

MEDIUM VOLTAGE

Product Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

Republic Wire Inc. Our Raw Materials Make A Quality Difference. Diversity Of Products Meets Customer Needs

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*)

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*)

OKONITE CABLES STOCK CATALOG In Stock for Immediate Delivery

Instrumentation Cables

5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables

IMSA TRAFFIC SIGNAL CABLE

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

MV-105 Power. (Tape Shield) 5-35kV 1/C EPR. Design Parameters. Description. Options. Installations

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry

Conductors and Raceway Design

CP CABLE. SPECIFICATIONS: 1. CONDUCTOR: Bare, soft drawn copper, Class B stranding per ASTM B INSULATION: High molecular weight polyethylene.

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

5-35kV 1/C TRXLE MV-90 POWER (wire shield) Medium Voltage Commercial & Industrial Cables

Module 2 Unit 6, 7, 8

5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

St. Monica Food Pantry Low Voltage (600V and less) Conductors and Cables sys-tek No

5-35kV 1/C TRXLE MV-90 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables

DLO Flexible Power Cable

POWER CSA. Jacket Black sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

TIGER BRAND MINING CABLES

CONTINUING EDUC ATION

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

Wiring of the Main Distribution Panelboard

GEXOL WORLD CLASS OIL & GAS CABLES

Electrical Wiring: Commercial, Seventh Canadian Edition

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

Addison Medium Voltage Cables

Tri-Rated Flexible PVC Equipment Wire

Article 225: Outside Branch Circuits And Feeders

NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING

HELUKABEL UL-LISTED CABLES

Hendrix Tap, Tie & Ground Wire

Wisconsin Contractors Institute Continuing Education

Low Voltage AIRGUARD. A proven, rugged product for harsh environments

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Wire Gauge Chart. Cigar Lighter 10 to 12. Dome Light 1. Radio 2 to 4. Gauges 0.7 to 1. Instrument Lights 1.5 to 3

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

Journeyman's Practice Exam

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

GENERAL SUBSCRIBER SERVICES TARIFF Pembroke Telephone Company, Inc. Third Revised Contents Sheet 1 Cancels Second Revised Contents Sheet 1

MV Power Cable Testing Training

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS

Creating. There is one basic question every customer needs to address when creating custom

POWER SERVICE DETAILS

Airport Cables & Connectors

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

Specifications Approval Type M12 A-coded HARAX M12-L HARAX M12 L 5 poles shielded M12 Crimp General data Electrical characteristics Materials 03 21

SECTION BUILDING WIRE AND CABLE

Short-Circuit Current Calculations

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

American Electrical Institute

Power-limited Circuit Cable. Features & Applications: Specification. Power-limited Circuit Cable

The STrongeST Link to your SucceSS... From ViSion to FiniShed ProducT

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Medium Voltage Power Cables

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

Speaker Audio System Cables

Instrumentation Cable PLTC/ITC and TC Types

6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

Detailed Specifications & Technical Data

P Low Voltage Catalogue Cables Australia Powering your Project

PRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another.

TE Connectivity Wire Connectors

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

Article 250 Grounding & Bonding

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from

SECTION Q WIRE AND CABLE Wilson Avenue, Toronto, Ontario, Canada, M9M 1A1 Ph: Fax:

Power Cables and their Application

Underground System Design TADP 547


Shielded Fire Alarm Cables

WIRE AND CABLE SECTION M WIRE AND CABLE. TEW / TEWN and TR-64 Wire. SPT1 / SPT2 / SEW1 AND SEW2 Wire. SVT / SJT / SO AND SOOW Cords

Transcription:

CATALOG OF PRODUCTS

Isolated Copper Wire THHN/MTW/THWN-2 600V, single conductor having flame-retardant and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material. The wire is rated 90 C dry, 90 C wet for THWN-2. It can be made both from solid or stranded copper. In accordance with UL Standard 83 (Thermoplastic Insulated Wires and Cables) and the National Electric Code (NEC). Copper Wire THHN/MTW/THWN-2 1 24 38 Stranded Copper Wire THHN/MTW/THWN-2 1 24 38 63 95 153 3 AWG 189 234 1 AWG 299 2 462 52 12 851 300MCM 1010 350MCM 110 400MCM 1330 1650 600MCM 85 50MCM 2466

Lightning and Grounding Copper Wires Single bare copper conductors, solid or stranded copper, specially designed for lightning protection and grounding. In accordance with ASTM-B3-4 Specification Lighting and Grounding 50 9 126 200 62 MCM 6x.051 6 2 MCM x.051 229 104 MCM 6x.066 329 104 MCM 8x.066 329 122 MCM x.066 384 131 MCM 6x5/0.066 411 x.04 332 x.069 4 /0.094 518 x.086 652 /0.05 652 x.094 9 /0.0.82 1 /0.0116 1543 C A T A L O G O F P R O D U C T S Yo u r Be s t S u p p l i e r o f E l e c t ri c a l C a b l e s

Isolated Copper Wire RHH/RHW-2/USE-2 600V, single conductor having heat, moisture and abrasion-resistant cross-linked polyethylene insulation. The wire is rated 90 C dry or wet. It can be used for control and power in conduits and raceways as well as directly buried as underground service entrance cable. In accordance with UL Standard 44 (Thermoset Insulated Wires and Cables), UL Standard 854 (Service Entrance Cables) Stranded Copper Conductor 21 30 44 2 106 156 3 AWG 201 238 1 AWG 309 381 42 586 29 86 300MCM 1029 350MCM 11 400MCM 1352 164 600MCM 2012 50MCM 2492

Isolated Copper Wire XHHW-2 600V, single conductor having heat-resistant cross-linked polyethylene insulation. The wire is rated 90 C dry or wet. In accordance with UL Standard 44 (Thermoset Insulated Wires and Cables) Copper Wire XHHW-2 18 26 40 66 99 149 3 AWG 185 230 1 AWG 292 363 452 565 05 835 300MCM 995 350MCM 1155 400MCM 1314 1633 600MCM 66 50MCM 2441

NM-B (Non-metallic sheathed cable) 600V, multiple conductor having heat and abrasion-resistant nylon jacketed polyvinyl chloride (PVC). The wire is rated 90 C dry. It can be 2, 3 or 4 conductor cable with ground. Conductors are color-coded. Primarily used in residential wiring as branch circuits for outlets and switches. In accordance with UL Standard 83 (Thermoplastic-Insulated Wires and Cables) and UL Standard (Standard for Nonmetallic-Sheathed Cables) NM-B 2 Conductors in Cable Ground 58 82 125 186 255 NM-B 3 Conductors in Cable Ground 4 10 164 253 35 NM-B 4 Conductors in Cable Ground 90 132 205 NM-B 2/2 Conductors in Cable Ground 90 132 205

Covered Line Wire Single conductor having heat and moisture resistant black polyethylene coverage. Used as primary and secondary distribution on pole lines, overhead secondary distribution lines. s from 6AWG up to. In accordance with ASTM s B1, B3 and B8. Covered Line Wire 3 AWG 8 136 15 218 Stranded Covered Line Wire 90 141 22 363 453 566 08 825 300MCM 985 350MCM 1145 16

Transformer Riser Wire Used as uninsulated transformer risers at voltages up to and including 13.2kV. The polyethylene black covering on transformer riser wire reduces faults due to atmospheric conditions, shorts caused by excessive vibrations and faulting caused by objects crossing the leads. s 8, 6 and 4 AWG, solid only. In accordance with ASTM s B3 and B8. Copper Conductor 83 11 10 Bare Copper Wire conductors are primarily used for overhead transmission and distribution applications. Stranded conductors are used for uninsulated hook up, jumpers and grounding. s from 14AWG up to 1000MCM. In accordance with ASTM s B3, B8 and B8. There is a large variety of products and applications under this category, so please contact us with your specific requirements. You can also visit our Lightning and Grounding product to see an application example.

www.wireintegration.com 2332 Galiano Street Coral Gables FL33134 Phone (305)28-112 Fax (305)28-113 sales@wireintegration.com