Technical data. General specifications V DC No-load supply current I 0. typ. 50 ma Power consumption P 0

Similar documents
Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 700 a at 40 C Mission Time (T M ) L 10

Technical data. General specifications. Linearity error ± 0.1 Electrical specifications Operating voltage U B

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 700 a at 40 C Mission Time (T M ) L 10

Technical data. General specifications V DC Power consumption P 0. 1 W Time delay before availability t v

Multiturn absolute encoder

Multiturn absolute encoder

Multiturn absolute encoder

Absolute encoders - SSI

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

Absolute encoders - SSI Shaft with clamping or synchro flange Optical multiturn encoders 14 bit ST / 12 bit MT

Technical data. Functional safety related parameters MTTF d Mission Time (T M ) max. 140 ma Power consumption P 0. Voltage drop

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders 18 bit ST / 12 bit MT

FVS58 singleturn absolute encoder. FVS58. Technical Product description data Incremental encoders special designs. Technical data

TECHNICAL DATASHEET Absolute Encoder AC 58 - BiSS / SSI

Technical data. General specifications. Measurement range min max. 360

Magnetic absolute single-turn encoder BMSH MAGRES parallel

ABSOLUTE ROTARY ENCODER SSI

Encoder - Absolut 2RMHF-SSI

Absolute multi-turn hollow shaft encoder BOMH Dignalizer SSI

ABSOLUTE ROTARY ENCODER SSI

Incremental Encoder for special applications

ABSOLUTE ROTARY ENCODER SSI

MHAD 50 - HDmag. Features

Absolute encoders - SSI EX approval ATEX EEx d IIC T6 Optical single and multiturn encoders 14 bit ST / 12 bit MT

Material: Weight: Shaft Loads:

Magnetic absolute multi-turn hollow shaft encoder BMMH MAGRES SSI

Magnetic absolute rotary encoder GEL 235 Singleturn, Multiturn up to 28 bits (SSI)

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

DATASHEET ABSOLUTE MAGNETIC ROTARY ENCODER SSI

Electrical data Units FVS 58, FHS 58. Operating voltage (PELV) [VDC] Current consumption at 24 VDC [ma] 85

TECHNICAL DATASHEET Absolute Encoder AC 36 - BiSS / SSI

Absolute Encoders Multiturn

Cable transducer Analog output / redundant Measuring length absolute up to 5 m

Absolute Encoders - Singleturn

Absolute Encoders Singleturn

ABSOLUTE ROTARY ENCODER SSI PROGRAMMABLE

LENORD. +BAUER... automates motion. GEL 2037 with heavy duty flange or tooth wheel adapter. Technical information Version General.

Incremental encoders With blind or through hollow shaft pulses per revolution programmable

TECHNICAL DATASHEET Absolute Encoder AC 36 - BiSS / SSI

DS-25. Absolute position, rotary Electric Encoder

Incremental encoders Blind or through hollow shaft ø12 mm pulses per revolution

Absolute Encoders Multiturn

Rotary Measuring Technology

Incremental encoders With blind or through hollow shaft pulses per revolution programmable

RM36. Rotation sensors RM36 Absolute rotary encoder

LENORD. +BAUER... automates motion. Magnetic absolute rotary encoder GEL 2037 with heavy duty flange or tooth wheel adapter

Rotary Measurement Technology Absolute Encoders, Multiturn

ABSOLUTE ROTARY ENCODER MULTI-TURN BIT PARALLEL

Absolute encoders - analog Blind hollow shaft ø12 mm Magnetic single- or multiturn encoders 12 bit ST / 16 bit MT

ABSOLUTE ROTARY ENCODER DEVICE NET

Series BC 58. Absolute Rotary Encoder Series BC 58

DS-70. Absolute position, rotary Electric Encoder

DS-58[20] Absolute position, rotary Electric Encoder

PRELIMINARY RE36 SERIES MAGNETIC ENCODER

RM36 series non-contact rotary encoders

ABSOLUTE MAGNETIC ROTARY ENCODER ANALOG

ABSOLUTE MAGNETIC ROTARY ENCODER ANALOG

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

Incremental Encoder Model: FOI58

0.04 mm Distance/revolution mm ±0.05% f. s.; ±0.01% f. s. as option. Measurement range (in mm) 2500 (smaller measurement ranges included)

NOVOTURN Multiturn Sensor non-contacting. Series RSM-2800

Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % ( )

Rotary Measuring Technology

Absolute Encoders - Singleturn

Oil & Gas / Heavy Industry Type 2REX-A-NA-SSI

POSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire

Rotary encoders. absolute / optical. Bright ideas in the measurement of rotation: robust, precise, versatile.

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

Absolute encoder GEL 15X F. Serial (SSI) or parallel interface, PC-programmable. Technical information version 01.06

Incremental hollow shaft encoder BRIH EcoMag

Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % ( )

Online data sheet AFS60E-S1AA AFS/AFM60 SSI ABSOLUTE ENCODERS

Absolute encoders multiturn

ENCODER. SSI Multiturn. Series , Key-Features: Content:

Magnetic absolute encoder GEL 2035 Serial interface (SSI), 24 Bit

Online data sheet AFS60A-BJPA AFS/AFM60 SSI ABSOLUTE ENCODERS

Encoders. Series 21 Hollow-Shaft Rotary Optical Encoders Digital incremental or sine/cosine and absolute format. Features & Benefits.

Express Delivery. Axial. Connection

NOVOHALL Rotary Sensor non-contacting. Series RSC-2800

Standard Industrial types RI 36-H

RM22 rotary magnetic modular encoder

Absolute encoders multiturn

TECHNICAL DATASHEET Incremental Encoder RI 30

ABSOLUTE ROTARY ENCODER CAN-BUS

Data Sheet for Angle Sensors

E A M P A R A L L E L - S S I M U L T I T U R N A B S O L U T E E N C O D E R

DG 60 L Incremental Encoder

POSIWIRE. WS85 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

Diameter ø50mm Shaft type Absolute Multi-turn Rotary Encoder

Incremental Shaft Encoders Industrial types

Absolute Rotary Encoder EXAG Explosion Proof. Canopen

Standard Industrial Types RI 58-O / RI 58-T

SHAFTED ROTARY POSITION SENSORS

E A P A R A L L E L - S S I

Standard Industrial types RI 58-O / RI 58-T

Absolute Rotary Encoder EXAG Explosion Proof. Device Net

ABSOLUTE ROTARY ENCODER DEVICE NET

More Precision. wiresensor // Draw-wire displacement sensors

Features & Benefits 360, 512, 720, 1000, 1024, 1440, 1800, 2000, 2048, 2880, 3000, 3600, 4000, 4096, 5000, 5120, 6000, 7200, 8000, 8192, 9000, 10000

Transcription:

Model Number SYNCHRON SERIELLES INTERFACE Cable pull rotary encoder with SSI interface Features Solid yet lightweight plastic construction Compact, slim design (the shaft of the mounted rotary encoder is used to provide the function of the drum bearing) Coupling-free adaptation Wide range of mounting options Rust and acid-resistant measuring cable Very high level of linearity and repeatability SSI interface Free of wear magnetic sampling Additionally push buttons for preset function (only model characteristic SB, SG) Description Lighter and more solid cable pull rotary encoder with flat housing design. Technical data General specifications Detection type Device type Measuring range Construction type Resolution magnetic sampling Target line with SSI interface 000... 0000 mm 80 mm, 0 mm, 90 mm Cable pull: design 80 mm: with Bit 0,08 mm; with Bit 0,0 mm design 0 mm: with Bit 0,0 mm; with Bit 0,09 mm design 90 mm: with Bit 0,08 mm; with Bit 0,0 mm Encoder: Bit ( Bit/revolution) or Bit ( Bit/revolution) Functional safety related parameters B 0d 00000 Electrical specifications Operating voltage U B.... 0 V DC No-load supply current I 0 typ. 0 ma Power consumption P 0 approx.. W Output code Gray code, binary code Code course (counting direction) adjustable Interface Interface type SSI Transfer rate 0.... MBit/s Cycle time < 00 µs Standard conformity RS Input Input type Selection of counting direction (cw/ccw) Signal voltage High. V... U B (cw descending) Low 0... V or unconnected (cw ascending) Input current < ma Input Input type zero-set (PRESET ) with falling edge Signal voltage High. V... U B Signal duration. s Connection M connector, 8-pin or M connector, -pin Cable Ø mm, x x 0. mm, m (cable length, see order code) Standard conformity Degree of protection DIN EN 09, IP Connection side cable models: IP connector models: IP Cable pull: IP0 Climatic testing DIN EN 008--, no moisture condensation Emitted interference EN 000--:00 Noise immunity EN 000--:00 Ambient conditions Ambient temperature -0... 0 C (-... 8 F) Operating temperature -0... 0 C (-... 8 F) Storage temperature -0... 0 C (-... 8 F) Relative humidity 98 %, no moisture condensation Mechanical specifications Rope diameter 0. mm Bending radius min. mm Breaking force min. 0 N Material Housing nickel-plated steel Cable pull plastic, Lexan 90 Flange Aluminum Rope Stainless steel.0/ Life span up to 0 Cycles

Dimensions For design 80/0 B A x X C H F D J x Y For design 80/0 X Y 80 0 M, 8 M, Ø, Ø, E G Design 90 A 90 0 B 9 C 80. 0 x ø 8. x M8 8 9

Connections Dimensions in mm Cable M M ~8. exit position radial exit position radial exit position radial A ~ 0 ø 9 ø 0 ø ø 9 ø 0 C ~ 0 0 ø 0

B ø ø ~ 9 Electrical connection Signal Cable, -core M, 8-pin M, -pin, cw M, -pin, ccw Explanation GND (encoder) White Power supply U b (encoder) Brown 8 Power supply Clock (+) Green Positive cycle line Clock (-) Yellow Negative cycle line Data (+) Grey Positive transmission data Data (-) Pink 0 Negative transmission data Reserved Black Not wired, reserved V/R Red 8 8 Input for selection of counting direction PRESET Blue 9 9 zero-setting input Reserved Violet 0 Not wired, reserved Reserved Grey/Pink Not wired, reserved Reserved Red/Blue Not wired, reserved 8 8 9 0 0 9 8

Description The Synchronous Serial Interface was specially developed for transferring the output data of an absolute encoder to a control device. The control module sends a clock bundle and the absolute encoder responds with the position value. Thus only lines are required for the clock and data, no matter what the resolution of the rotary encoder is. The RS interface is optically isolated from the power supply. SSI signal course Standard T T p Clock + T m Data + D n D n- D n- D n- D D S MSB LSB D,..., D n : S: MSB: LSB: Position data Special bit Most significant bit Least significant bit T = /f: T m : T p : Duration of period of clock signal MHz Monoflop time 0 µs ± µs Clock pause monoflop time (T p T m ) SSI output format Standard At idle status signal lines "Data +" and "Clock +" are at high level ( V). The first time the clock signal switches from high to low, the data transfer in which the current information (position data (D n ) and special bit (S)) is stored in the encoder is introduced.± The highest order bit (MSB) is applied to the serial data output of the encoder with the first rising pulse edge. The next successive lower order bit is transferred with each following rising pulse edge. After the lowest order bit (LSB) has been transferred the data line switches to low until the monoflop time T m has expired. No subsequent data transfer can be started until the data line switches to high again or the time for the clock pause T p has expired. After the clock sequence is complete, the monoflop time T m is triggered with the last falling pulse edge. The monoflop time T m determines the lowest transmission frequency. SSI output format ring slide operation (multiple transmission) In ring slide operation, multiple transmission of the same data word over the SSI interface makes it possible to offer the possibility of detecting transmission errors. In multiple transmission, n bits are transferred per data word in standard format. The value n equals the total resolution of the encoder. As an example: a multiturn encoder with a resolution of 89 steps/revolution ( bit) and a max. number of 09 revolutions ( bit) has a total resolution of n = bit. If the clock change is not interrupted after the last falling pulse edge, ring slide operation automatically becomes active. This means that the information that was stored at the time of the first clock change is generated again. After the first position transmission, the n+ pulse controls data repetition. If the n+ pulse follows after an amount of time greater than the monoflop time T m, a new current data word will be transmitted with the following pulses. If the pulse line is exchanged, the data word is generated offset. Block diagram Logic Rotary encoder Data + Data - Clock + Clock - Receiver Clock generator Interface electronics Line length Line length in m Baudrate in khz < 0 < 00 < 00 < 00 < 00 < 00 < 00 < 00

Push buttons on encoder with model characteristic SB, SG In addition to the electrical preset function (PRESET ) these models are equipped with push buttons for manually setting the zero point of the rotary encoder. Manually zero set. Simultaneously press and hold the push buttons A and B for s. After releasing the push buttons the rotary encoder sets the current position as zero point. Variable Data and Dimensions Technical data Design 80 Design 0 Design 90 Measuring length (in m) 0 0 0 Drum size (incl. cable) (in mm) 0 8 Retraction speed (in m/s) Spring retraction force (in N).. 9 Weight (in kg) 0... Shock resistance Vibration resistance DIN EN 008--, 00 g, ms DIN EN 008--, 0 g, 0 000 Hz Dimensions (in mm) A. 80 9. B 0. 0 C... D 0 - E - F 0 8 - G. - H 08 0 - J 80 0

Model Number E C A 0 T L - N P - : Resolution (special option) Bit single turn (standard version Bit single turn) Electrical connection C Cable, m C Cable, m C Cable, m CA Cable, 0 m AA M device plug, cw AB M device plug, ccw BE M device plug, 8-pin Electrical interface SB UB =, V... 0 V, SSI binary SG UB =, V... 0 V, SSI Gray SB UB =, V... 0 V, SSI binary, with push buttons SG UB =, V... 0 V, SSI Gray, with push buttons Cable mounts A Ring PE carrier (with 0 m only) B Eyelet C Ball joint (with 0 m only) Length of measuring cable 0 m 0 m 0 0 m