Operating Instructions. for. Controller SMS 150 / 151

Similar documents
Operating Instructions. for. Controller SMS 160 / 161

Frequency Controller SIGA (V6) Translation of operating and installation instructions

Controllers for Vibratory Feeder Engineering REOVIB MTS 440/442. REO-USA, Inc. Thyristor controllers for vibratory feeders With digital settings

FREQUENCY-CONVERTER MFR 600A / 1500A Version 2

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Installation, Operation and Maintenance Instructions

Orbital GFI Inverter Series

Installation, Operation and Maintenance Instructions

TE200S Solid State Relays. Two-phase control of three-phase loads. User manual

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Installation and Operating Instructions for Phase Demodulator Type _.2

Operating instructions Fail-safe delay timer AZS About this document. Content

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Impulse system MPT 700. Manual Edition GB

FREQUENCY-CONVERTER MFR 600A

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

Power supply CP-E 24/2.5

Instruction manual for STA 1 sectional door operator

Cable Identifying Generator LCI TX / LCI TX-440

Power supply CP-E 24/0.75

User s Manual Current Probe. IM E 2nd Edition IM E

Power supply CP-E 24/20.0

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Parallel. Parallel. data transmission. Technical Information TR - ECE - TI - GB /05/2016

Instruction manual for STA 1 sectional door operator

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

Process/Mini. English IMPORTANT NOTE. Installation and Operation Manual. General Purpose Light Curtain with 30 mm resolution

Power supply CP-E 24/2.5

QUINT-PS/ 3AC/24DC/10

DB 12 B. Double Sheet Testing Unit. Phone: Fax: Web: -

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

PRetrans Table of contents

Gate control mts2000/02 R2.8

MATRIX INDUCTIVE LOOP CONTROL BOX

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

Precipitation Monitor ,

PROXIMITY SENSOR TERMINOLOGY

Power supply CP-D 24/1.3

Electronic Air / Fuel Ratio Control System

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Power supply CP-D 12/2.1

Linear feeder HLF07-P / 12-P Translation of operating and installation instructions

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Power supply CP-T 48/20.0 Primary switch mode power supply

QUINT-PS AC/24DC/40

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit

Power supply CP-T 48/5.0 Primary switch mode power supply

MINI-PS AC/24DC/1.3

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-T 24/20.0 Primary switch mode power supply

INSTRUCTION MANUAL (ATEX / IECEx)

3B SCIENTIFIC PHYSICS

Power supply CP-T 24/10.0 Primary switch mode power supply

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Documentation. Content. Measurement and Control. Type: ELT-GP1. 1. Installation instructions 2. Data sheets 3. Declarations of conformity

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

Power supply CP-T 24/40.0 Primary switch mode power supply

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

DeltaSol AX HE * * Differential temperature controller Manual for the specialised craftsman

EY-EM 527: Remote I/O module, ecolink527

R180. AVRs. Installation and maintenance

Operating Instructions

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Inductive sensor slot-type SI2-K08-AP7

3B SCIENTIFIC PHYSICS

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Power supply CP-D 24/4.2 Primary switch mode power supply

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E

English. Operating manual. Temperature measuring transducer MU125. Save for later reference. Company / brands of GHM

Proximity Sensor Terminology

TC1028 series. Thyristor units. Control of single-phase resistive or inductive loads. User manual (300A to 500A rated units)

Precipition Sensor with analogue Intensity Output ,

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

QUINT-PS/ 3AC/24DC/40

P331-2 set ESD generator (IEC )

Commissioning and Maintenance of Power Factor Correction Systems

PU202 Level converter & encoder signal generator without potential separation

QUINT-PS/ 1AC/24DC/20

Manual SCA-SS V /02 page 1

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO E

Universal Controller

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Operating Instruction

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Amplifier Series BASIC. Installation & Operations Manual

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

S1 Programming Chart Program Description S1 Switch Positions. Constant ON High/Low Track, WR

S D 1 Operating Instructions

Description of CERTO controller Standard

Flow Detection MDS Integral or Remote Housing. Installation and Operating Instructions

Mounting Guide ThermoControl 3

SCA-SS (70V, 10A)

USER S MANUAL. Rail-mounted temperature transmitter ATL

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

MINI MCR-SL-UI-f(-SP)

Transcription:

Operating Instructions for Controller SMS 150 / 151

Contents Controller SMS 150 / 151... 1 Contents... 2 Reserve... 2 1. Safety instructions for users... 3 2. Application... 4 3. Warnings... 5 4. Installation... 5 4.1 Overview and dimensions... 7 4.2 Technical data... 8 4.3 Connection possibilities... 9 4.4 Starting... 11 5. Operating tips... 11 6. Repairs... 11 7. Troubleshooting... 12 Declaration of conformity... 13 Reserve General informations und data contained in this documentation can changed without announcement. Errors and omissions excepted. The users are committed to observe all applicably copyright laws. Without explicit permission in written form of the company RUG Regler und Gerätebau GmbH no part of this documentation may copied or communicate for any purposes, independently in which kind or with any instruments, electronically or mechanically, this happens. 2

1. Safety instructions for users These instructions contain the necessary information for the correct use of the products described. They are for use by technically qualified persons. Qualified personnel are those persons whose vocational training, experience and internal training and their knowledge of the relevant standards, regulations, accident prevention regulations and plant operating conditions has led the person responsible for operational safety to authorise them to carry out the necessary work, and are able to recognise and avoid potential risks (definition of skilled workers as per IEC 364). Risk information The following information serves not only the personal safety of the operating personnel but also the safety of the products described herein and appliances connected to them. DANGER! Highvoltage operations. Noncompliance can lead to death, serious injury or damage to property. Always disconnect the supply voltage before assembly or dismantling work, when replacing fuses or altering the structure. The relevant Accident Prevention and Safety at Work Regulations must be complied with at all times. Before commissioning, make sure that the appliance's nominal voltage conforms to the local mains voltage. EMERGENCY SWITCHES must remain operational in all working modes. Unlocking EMERGENCY SWITCHES must not lead to uncontrolled. Electrical connections must be covered at all times! After assembly, check all protective conductor systems for correct functioning! Proper use The appliance described here is an electrical device for use in feeder equipment or automation plant. The appliance has been planned for use in oscillation conveyors, in control and automation technology. 3

This appliance conforms to the relevant LowVoltage and EMC Guidelines. 2. Application The SMS 150/151 electronic controller is used for stepless control of inductive loads such as spiral conveyors, linear conveyors and hoppers. The controller works on the phase control system, the conveyor output is carried out by setting the magnet voltage via the setpoint potentiometer integrated in the casing cover. The control curve of the setpoint value voltage can be restricted by means of two trimming potentiometers, Umin and Umax, on the board in such a way that the complete range of the setpoint value can always be used. The ignition impulses can be displaced infinitely in the range of the positive or negative mains voltage halfwave through the setpoint voltage adjustable with the setpoint, which then sets the voltagetime area of the output voltage is set. With feeder appliances with 50 Hz oscillation frequency both (positive and negative) mains voltage halfwaves are controlled, and with feeders with 25 Hz oscillation frequency only one mains voltage halfwave is controlled. The switchover between fullwave and halfwave mode is carried out as a standard with a sliding switch on the board (see Connection Possibilities). After the working voltage has been switched on the integrated variable softstart is started and guarantees smooth acceleration of the output voltage to the preset voltage value. This eliminates possible switching peaks. In addition, the softstart, and the softstop, become effective when the output voltage is switched on and off via the controller input for the level control system and serves to increase or decrease the conveyor output on a timecontrolled basis so that bulk material does not change its position. Both these times can be set separately. The controller input controls the running time of the oscillation conveyor in such a way that unnecessary running time are avoided. Internal variable times (GAN and GAB) are used to turn the oscillation conveyor ON or OFF in dependency on the material level measured via a material sensor. The controller input enables the turn On and OFF of the controller load output through another system (SPS, initiator, sensor and other). The controller has an integrated power supply for +24VDC. A turn ON and OFF through a external +24VDC voltage is possible. The controller input takes affect to the ignition pulses. Measurements of the output voltage (arithmetic value measurements) enable changes to the voltage to be registered immediately an compensated by means of a controller stage. This guarantees even running of the bulk material. 4

Miniature magnets can also be operated safely at the controller! Setting the ON and OFF time delay for the level controller The level of the material in the filling section is measured by the GAN and GAB trimmers. To increase the material backup downstream from the sensor, use the GAB trimmer to lengthen the controller's OFF delay time. Reduce the GAB time to reduce the backup of material. The GAN trimmer can now be used to determine the time that passes from when the last part of the material leaves the sensor position until the feeder appliance is switched on The diagram shows the time sequence in operations with the controller input low active: V GAN SA GAB SS X 0 0,110s 0,55s 0,110s 0,15s Output voltage t 1 0 Signal at control input t 3. Warnings!!! In the case of applications that require the oscillation conveyor to be switched ON and OFF constantly (e.g. dust switched off, hopper control system, etc.), the prescribed controller input must be used. If the load circuit is disconnected with a switch or a relay the controller may be damaged. If the controller is switched on, never insert or remove the plug at the vibration conveyor being operated. This can damage the appliance. Repair work must be carried out by qualified personnel only. We recommend that repairs are carried out on our premises. 4. Installation 5

For mounting of the controller there is a hole and a long hole accessibly from the outside. These holes are separated from the interior of the housing. Mounting on a vibration free background. Please notice, the interior ribbon cables may not squeezed against the housing. When the ribbon cables are squeezed there can be a shortcircuit and the controller can be destroyed! 6

4.1 Overview and dimensions 7

4.2 Technical data Type SMS 150 / SMS 151 Mains voltage 230V AC / +10% / 115V AC / +10% Mains frequency 50Hz / 60Hz Output frequency 25Hz/50Hz / 30Hz/60Hz Output voltage 30 228 V AC / 30 113 V AC Setup to 200 VAC Output current 0,01 6 A AC Type of protection IP 54 at mounting hanging (fitting show down) Fuse 1 x 6,3 A F flink Ambient temperature 0.. 50 C Setpoint Internal potentiometer Mains connection 2m with gated Schukoplug 90 Connection conveyor 2m witht Contact HA3BS plug Housing Albackground + AlStrand casting + Plastic cover Dimensions (l x b x h) ca. 175 x 80 x 94 mm Features: Oscillation frequency Controller input isolated Switching level HI: 6 24 VDC Switching level LO: 0 4 VDC Reversible +24 V DC / max. 50mA / PNP Opener mode: Output voltage 0 V with applied switching voltage of + 24 V DC Preset output voltage with applied switching of 0 V DC Twin timer (GAN/GAB) Softstart t1 Softstop t2 Mains voltage compensation (arithmetic measurement) Closer mode : Output voltage 0 V with applied switching voltage of 0 V DC Preset output voltage with applied switching voltage of + 24 V DC GAN turn ON delay : 010 seconds GAB turn OFF delay : 010 seconds ca. 0.5 5 sec. Variable ca. 0.1 5 sec. Variable Compensation of mains voltage fluctuations at output. With preset output voltage of e.g. 170 V AC a max. voltage change of 3,5 V AC arises, with changes of the input voltage from 230 V AC to 200 V AC or from 230 V AC to 260 V AC. Standards complied with DIN EN 50 081 Part 1 Residential, commercial and trade and light industry, industry. DIN EN 50 082 Part 2 Industry VDE 0160 8

4.3 Connection possibilities Connection conveyor Pin 1 Load Pin 2 Load Pin 3 NotConnected PE Protective earth 9

Connection sensor / control input Pin 1 +24 VDC / max.50ma / PNP Pin 2 NotConnected Pin 3 ground Pin 4 Input 1 The +24VDC supply is isolated to 230VAC und +5VDC side of the CPU! Programming Dip 1 Frequency 50/25Hz OFF 50Hz ON 25Hz Dip 2 Setpoint fixed OFF Setpointpotentiometer active ON Setpointpotentiometer inactive Value fixed by switching Dip 3 Control OFF Output has reaction on control input and Closer/opener ON Output always ON, no reaction on control Input and closer/opener Dip 4 Input 1 OFF value opener ON value closer (input 1 inverted) Values Umin Low limit of the output Umax High limit of the output SA SS Soft start Soft stop Right rotary Min left limit stop Max right limit stop GAN 1 Turn ON delay input 1 GAB 1 Turn OFF delay input 1 10

4.4 Starting 1. Before connecting the controller, check the working voltage and working frequency of the conveyor and compare them with the technical data for the controller. The output current of 6A should not be exceeded. 2. Depending on the working frequency of the conveyor, set the slide switch on the board: Fullwave operations 50/60 Hz (slide switch above) Halfwave operations 25/30 Hz (slide switch below) 3. 4. 5. 6. 7. Check the programming on the board in dependence on the type of switching and set. Connect the conveyor to the controller. Insert the controller's plug into the mains. Switch the controller on. Set the required control range with the Umin and Umax potentiometers. 5. Operating tips 1. 2. 3. Before switching on, check that the controller is correctly plugged into the conveyor. Switch the controller on with a mains switch. If required, adjust the setpoint until the vibration conveyor reaches the desired output. 6. Repairs Replacing fuse 1. Replace defective fuse with a 6,3 A F fuse. Fuse is available over fuseholder in the cover. 11

7. Troubleshooting Appliance not working Check the mains voltage, check the fuse and replace if necessary. Is the controller input set correctly, programming correct? No output from conveyor Check whether the correct oscillation frequency has been set, change setting where necessary. Check the mains frequency (50/60 Hz). The oscillation frequency and the mains voltage must agree. Umax trimmer set too low. Set Umax. Conveyor vibrates too much, magnet knocking (noises) Oscillation frequency setting incorrect. CAUTION! Magnet may have been destroyed by overheating or damaged mechanically by knocking. Umax trimmer set too high. Set Umax if necessary. Magnet heats up Magnet has incorrect mains voltage, check. Incorrect oscillation frequency set, change if necessary. Controller input not working Control voltage polarity reversal, check. Correct jumper for controller input? Check. 12

Declaration of conformity The company RUG Regler und Gerätebau GmbH KarlEhmannStr.50 73037 Göppingen hereby declares in its own responsibility that the product control appliance for oscillation conveyor systems with the type designation SMS 150/151 (incl. derivatives) to which this declaration refers conforms to the following standards Basic standards for transient emissions : DIN EN 50 081 Teil 1 living quarters, business and trade area plus small companys Basic standards for interfernce resistancet : DIN EN 50 082 Teil 2 Industrial in accordance to the appointments of the EC Directive 2004/108/EG. 13