2X4 LED Panel Light RoHS 0-10V Dimmable QPL ID #

Similar documents
1X4 LED Panel Light RoHS 0-10V Dimmable QPL ID #

RoHS 0-10V Dimmable QPL ID # PXQGXDYK

VAC 60HZ A 120V; 0..18A 277V 40W PF ,000 LM 125 LM/W >82 <19. Arcata VDC 1.2A 120V 88% Edison

RoHS QPL ID # PLC6V1PABNUJS

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount. EPA Rating 2.33ft 2.

RoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount. Model: master carton: L*W*Hmm 1PCS. EPA Rating 1.

RoHS QPL ID # PNZ72BAB

RoHS QPL ID # PNZ72BAB

Dimming: PWM/TIME/0-5V/0-10V. RoHS


71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A


RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS

Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens

Cat# 71146A 150W Trunion Mount

71352A QPL ID # PLT2P2L2UNWR. RoHS

RoHS. Model: VAC 50/60HZ.83A Max 100W

Cat# 71440A LED Classic Large Wall-Pack

Direct to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0.

Cat# LED High Bay

Cat# LED Classic MINI Wall-PACK

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

Cat# LED Wall-PACK

Cat# LED Classic Large Wall-Pack

71332 LED Dusk To Dawn (Area Light)

LM Test Report

LM Test Report

Morris Products 53 Carey Road, Queensbury, NY 12804

QPL ID # PLG2YNJ831VZ

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

LM Test Report

LM Test Report

Morris Products 53 Carey Road, Queensbury, NY 12804

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

LM Test Report

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

IESNA LM (NOT INCLUDE SPATIAL NON-UNIFORMITY OF CHROMATICITY) ELECTRICAL AND PHOTOMETRIC MEASUREMENTS OF SOLID-STATE LIGHTING PRODUCTS

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

IES LM MEASUREMENT AND TEST REPORT. Test Model: SRLED-RTUS24-4K. Jeanne Han/Safety Manager

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

LED DOWN LIGHT (Dimmable)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

DRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co.

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)

LED DOWN LIGHT (Dimmable)

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

REVOLUTION LIGHTING TECHNOLOGIES INC

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

LED DOWN LIGHT Size : Φ196x76mm(7.72x2.99") Characteristics. Item Number Description. 5/6 LED Gimbal Down Light. CRI 90 Lumens.

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

Photometric Test Report

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

IES LM Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

LED DOWN LIGHT Size : Φ230x140mm(9.06x5.51") Characteristics Item Number Dimmable. Dimmable at 120V. CRI Lumens lms.

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

Morris Products 53 Carey Road, Queensbury, NY 12804

LED DOWN LIGHT (Dimmable)

Catalog Number UPC Number LED Spot Bullet Flood Light 15W 1620 Lumens Bronze

Catalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White

Photometric Test Report

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

LM Test Report. For SHENZHEN SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products

Approved Method:Electricaland Photometric

NVLAP LAB CODE:

NVLAP LAB CODE:

Photometric Test Report

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

Photometric Test Report

Transcription:

2X4 LED Panel Light RoHS 0-10V Dimmable QPL ID # PBU8ZA6Q Model: Input Voltage 120-277 VAC 60HZ Input Current 0.33A Max @ 120V; 0.15A Max @ 240V Input Power 50W Power Factor PF 0.95 OVERALL LAMP PARAMETERS Luminance 5,449 LM Luminous Efficiency 104 LM/W CRI >80 Beam Angle 112 Main Structure Aluminium Frame + Polystyrene Lens Output Voltage 12-24 VDC LED DRIVER Output Current Driver Efficiency 0..48A 88% Brand Weipeng WPC LED Manufacturer Runlite LED Type 2835 SMD LED LED Quantity 336 PCS LED Efficacy 130 LM/W Color Temperature 3000K Photocell - N/A Lifespan 50,000+ Hrs. Warranty 5 Years LIFESPAN & ENVIRONMENT IP Rating IP21 Dry Locations Operating Temperature -20 +40 Storage Temperature.Humidity -40 +80, 10 90% RH Safety Norms UL1598,UL8750, EN60598, EN61347-2-13, EN62031, EN62471 SAFETY&EMC Withstand Voltage Grounding Resistance I/P-FG: 2121VDC 25A 100mΩ Electromagnetic Compatibility EN55015, EN61000-2-3, EN61000-3-3, EN61547 Dimension Pls refer to attached dimension drawing Net Weight 0.6KG OTHERS Gross Weight Q'ty / Carton 纸箱 0.8KG 2 PCS Volume Housing Color 0.52Cbm/carton White www.morrisproducts.com

[t;]! - Shenzhen Belling Efficiency Testing Lab Report No.:BL 170307004-9 NVLAP LAB CODE 600102-0 Date of issue 2017-03-08 Version 1.0 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Total pages 15 Applicant: Morris Products Inc. Address: 53 Carey rd. Queensbury, NY 12804 For Product: 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model No.:, 71771, 71772 Test laboratory: Shenzhen Belling Efficiency Testing Lab., 1/F., Building 1, 1F, No.1 building, Meibaohe industrial park, Dalang street, Shenzhen, Guangdong Prov.518101, China. Complied by: Cherie Tang Review by: Jason zhou Project Engineer Technical Manager Note: This test report is perpared for the customer shown above and for the device described herein. It may not be duplicated or use in part without prior written consent from Shenzhen Belling Efficiency Testing Lab. This report must not be used by the customer to claim product certification, approval, or endorsement By NVLAP, NIST, or any agency of the Federal Government. Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

Page 2 of 15 Report No.: BL 170307004-9 3000K 5449.180 52.32 104.151 71771 4000K 5632.732 *I 52.33 2 107.639 3 71772 5000K 5816.283 52.34 111.125 *I: This value is calculated and the calculation formula is as below: 5632. 732 = (58 l 6.283-5449.180)/2+5449.180 *2: This value is calculated and the calculation formula is as below: 52.33 = (52.32+52.34)/2 *3: This value is calculated and the calcuation formula is as below: 107.639 = 5632. 732/52.33 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

1 General 1.1 Product Information Manufacturer Page 3 of 15 Report No.: BL 170307004-9 Morris Products inc. Manufacturer Address 53 Carey Rd. Queensbury, NY 12804 Brand Name Luminaire Type Model Number MORRIS 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces, 71771, 71772 Rated Inputs AC 100-277V 50/60Hz Rated Power 50 W NominalCCT 3000K I 5000K Date of Receipt Samples 2017-01-05 1.2 Standards or methods ANSI C78.377-2015 :Specifications for the Chromaticity of Solid State Lighting Products ANSI C82.77-2002: Harmonic Emission Limits-Related Power Quality Requirements for Lighting Equipment CIE Publication No.13.3-1995:Method of Measuring and Specifying Color Rendering of Light Sources IESNA LM-79-08 Approved Method: Electric & Photometric Measurement of Solid-state Lighting Products Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

Page 6 of 15 Report No.: BL 170307004-9 3 Test Result Summary 3.1 Integrating Sphere System 3.1.1 Electrical data Model Number Input VoltageM 120.06 71771 120.04 Frequency Input Power (Hz) Current (A) (W) 60 0.447 52.32 60 0.445 52.34 Power Factor 0.974 0.979 3.1.2 Additional Test Test Item Model Test Voltage M Frequency (Hz) Test Result Power factor 71771 120 60 277 60 120 60 277 60 0.974 0.914 0.979 0.920 Total harmonic 120 60 277 60 10.7% 16.3% distortion 71771 120 60 277 60 11.4% 17.1% Off state power 120 60 0 (W) 71771 277 60 0 3.1.3 Photometric data Model Number Luminous Flux (Im) 5449.180 71771 5816.283 Efficacy (lm/w) CCT (K) CRI 104.151 2887 84.0 111.125 4885 84.5 R9 14 14 3.1.4 Chromaticity Coordinate Model Number Duv 0.0000 71771 0.0043 X y u' 0.4452 0.4068 0.2547 0.3495 0.3637 0.2097 v' 0.5237 0.4911 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

Page 7 of 15 Report No.: BL 170307004-9 3.2 Goniophotometer System 3.2.1 Electrical data Model Number Input VoltageM Frequency {Hz) Input Current {A) Power {W) Power Factor 120.08 60 0.4298 51.11 0.9903 3.2.2 Photometric data Luminous Flux {Im) Efficacy {lm/w) S/MH {C0/180) S/MH {C90/270) Zonal Lumen in 0-60 {%lm) 5285.80 103.42 1.24 1.18 77.363 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

4 Test Data Page 8 of 15 Report No.: BL 170307004-9 Test Condition Temperature: 25 C Spectrum Range: 350-800 nm RH: 58% Scan Step: 5 nm Spectroracliometric Parameters 1.0 ---------- -------- 0.8 0.8 0.6 0.6 0.4 0.2 0.4 0.2 0 0 350 425 500 575 6S0 725 800 0 0.2 0.4 0.6 0.8 K Spectral Distribution CIE193 l Chromaticity Diagram Chromaticity Coordinates: x = 0.4452 y=0.4068 u'=0.254 7 v'=0. 23 7 Con-elated Color Temperature: 2887 K Luminous Flux: 5449.180 lm Chromaticity Difference: 0.0000Duv Dominant \.Vavelength: 582.0 nm(e Purity: 0. "588 Peak Wavelength: 560.6 nm Color Ratio: Kr-46.3% Kg=46.l % Kb=.6% Bandwidth: 19_,511111 Radiant Flux: 14.234 W Rendering Index: Ra = 84.0 R1=84 R2=95 R3=93 R4 = 81 R5 = 84 R6=94 R7=81 R8 = 60 R9 = 14 R10 = 88 Rl1 = 82 Rl2 = 75 Rl3 = 8 Rl4=97 Rl5 = 6 Elech ic Parameters Voltage: 120.06 V Power Factor: 0.9 4 Luminous Efficacy: 104.151 lm/w Cun-ent: 0.44 7 A Power: 52.32 W Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

Page 9 of 15 Report No.: BL 170307004-9 Test Condition Temperature: 25 C Spectrnm Range: 350-800 nm RH: 58% Scan Step: 5 nm Spectroradiometric Parameters LO --- --------------- 0.8 0.8 0.6 0.6 0.4 0.4 0.2 0.2 350 425 500 575 650 725 800 Spectral Distribution 0 0 0.2 04 0.6 0.8 X CIE1931 Chrnmaticity Diagram Chromaticity Coordinates: x = 0.3495 y=0.363 u' = 0,_09 v' = 0.4911 Co1Telated Color Temperature: 4885 K Lrnuinous Flux: 5816.283 1111 Chromaticity Difference: 0.0043Duv Dominant Wavelength: 569.0 mu(e) Purity: 0.1391 Peak Wavelength: 447.9 nm Color Ratio: Kr=34.-% Kg=54.1% Kb=ll.7% Bandwidth: -444.911111 Radiant Flux: 18.129 W Rendering Index: Ra = 84.5 R1 = 83 R2=91 R3=96 R4=81 R5=82 R6=87 R7=87 R8=68 R9=14 R10 = 79 R11 = 81 R12 = 57 Rl3 = 86 Rl4=98 R15=77 Electric Parameters Voltage: 120.04 V Power Factor: 0.9' 9 Ctment: 0.445 A Power: 52.34 W Lmninous Efficacy: 111.12 5 hn/w Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com