Vibrating Wire Instrumentation

Similar documents
Section 6 - Electronics

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

Methods for Reducing Interference in Instrumentation

RG58 Coaxial Cable: 2) Approval:

Signal Conditioning Fundamentals for PC-Based Data Acquisition Systems

Chapter 12: Transmission Lines. EET-223: RF Communication Circuits Walter Lara

A Few (Technical) Things You Need To Know About Using Ethernet Cable for Portable Audio

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

4. Digital Measurement of Electrical Quantities

Telecommunication Wiring Questions

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

MEP 382: Design of Applied Measurement Systems Lecture 5: Signal Conditioning

Electronic Measurements & Instrumentation. 1. Draw the Maxwell s Bridge Circuit and derives the expression for the unknown element at balance?

(i) Determine the admittance parameters of the network of Fig 1 (f) and draw its - equivalent circuit.

IF30. User's manual. Description. Table of contents IF30

Chapter 7: Instrumentation systems

ni.com Sensor Measurement Fundamentals Series

DATA TRANSMISSION. ermtiong. ermtiong

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Field Instrument Cable. Electrical Noise

Using the EVM: PFC Design Tips and Techniques

K3D60a ±100N. Description. The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes.

A short, off-center fed dipole for 40 m and 20 m by Daniel Marks, KW4TI

LENORD. +BAUER... automates motion. GEL 2444K PG Configurable rotational speed and position sensor with operating hours counter

Linear vs. PWM/ Digital Drives

PDu150CL Ultra low Noise 150V Piezo Driver with Strain Gauge Feedback

GSV-1H 010/250/2. Highlights

Anthony Chu. Basic Accelerometer types There are two classes of accelerometer in general: AC-response DC-response

Data acquisition and instrumentation. Data acquisition

Current Probes. User Manual

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

AquaDAT Analogue Input Expansion Unit

A Novel Control Method to Minimize Distortion in AC Inverters. Dennis Gyma

VE7CNF - 630m Antenna Matching Measurements Using an Oscilloscope

non-sheathed cables for fixed Wiring integrity is doing the right thing, even if nobody is Watching JiM stovall

M-Bus Master MultiPort 250L Installation and User Guide

National Instruments Switches

Load Cell Accessories and Services

C240-NFSM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

Torque Sensor Accessories and Services

HST-3000 TDR. What is a TDR? JDSU s HST-3000 TDR. Application Note

LENORD. MiniCODER plus GEL 2449 Configurable rotational speed and position sensor with operating hours counter. +BAUER... automates motion.

Chapter 2 Analog-to-Digital Conversion...

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables

Lock-Ins for electrical measurements

6. du/dt-effects in inverter-fed machines

IntelLiCoder (ICODER) - General information. ICODER - Measuring principle

Application Note # 5438

CHEMICAL ENGINEERING 2I03

PDu150CL Ultra-low Noise 150V Piezo Driver with Strain Gauge Feedback

Draw in the space below a possible arrangement for the resistor and capacitor. encapsulated components

B. Equipment. Advanced Lab

PART I THE USE OF A MAGNETIC PICKUP AS AN ALIGNMENT INDICATOR WITH A STRETCIIED-WIRF: TECHNIQUE. W. K. H. Panofsky PART II

Product Features Benefits The IMC Group Ltd.

Differential-Mode Emissions

Yana Dongles Tom Berger K1TRB (c)2016 v171227

TRANSDUCER INTERFACE APPLICATIONS

CAH CARD. user leaflet. 1 of 15. Copyright Issue 12.1 January 2015

Amplifiers in systems

PACSystems* RX3i IC695ALG600

Theremino System Theremino ADC Tester instructions and notes

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2


TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

Device Interconnection

Designing an MR compatible Time of Flight PET Detector Floris Jansen, PhD, Chief Engineer GE Healthcare

X2Y Capacitors for Instrumentation Amplifier RFI Suppression

SENSOR AND MEASUREMENT EXPERIMENTS

Summary 185. Chapter 4

SCIN. Shield Current Induced Noise. Causes and Solutions. Random Thoughts from Chicago

The design of Ruthroff broadband voltage transformers M. Ehrenfried G8JNJ

INSTRUCTION MANUAL SERIES TRANSMITTER

Testing Power Factor Correction Circuits For Stability

Books: 1. Data communications by William L Schweber 2. Data communication and Networking by Behrouz A F0rouzan

Experiment 5: Grounding and Shielding

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

Project Report Designing Wein-Bridge Oscillator

Figure 1: Closed Loop System

Webinar Organizers. Ryan Shea. Don Miller. Joe Ryan. Support Specialist. Applications Specialist. Product Manager. Precision Digital Corporation

Effectively Using the EM 6992 Near Field Probe Kit to Troubleshoot EMI Issues

DC- & For plant engineering, research and development. programmable high-precision extremely fast EMI-free bipolar & unipolar.

ENGN Analogue Electronics Digital PC Oscilloscope

University of Pennsylvania Moore School of Electrical Engineering ESE319 Electronic Circuits - Modeling and Measurement Techniques

PACSystems* RX3i IC695ALG600-DD

INSTALLATION & OPERATION MANUAL

easypll UHV Preamplifier Reference Manual

BASIC ELECTRONICS PROF. T.S. NATARAJAN DEPT OF PHYSICS IIT MADRAS

Inductive Loop Detector

ELG3336 Design of Mechatronics System

Learning Objectives:

201AP Charge Amplifier User Manual

Measuring Temperature with an RTD or Thermistor

Developer Techniques Sessions

Q Multiplication in the Wien-bridge Oscillator

COPPER + LWL RAW CABLES

1510A PRECISION SIGNAL SIMULATOR

The Allen-Bradley Servo Interface Module (Cat. No SF1) when used with the Micro Controller (Cat. No UC1) can control single axis

LOW NOISE / LOW DRIFT DIFFERENTIAL AMPLIFIER SP 1 004

Transcription:

Vibrating Wire Instrumentation Design, Operations & Lines Test Results System Diagram - Fig 1 Sensor Excitation Circuit Differential Amplifier + + Sensor Coil - - High Pass 100 Hz Digital Filter Low Pass 10 KHz Precision Frequency Counter +Therm/2.5V In 0V + Vib - Vib Introduction Phase Locked Loop Screened cable Shield Differential Vibrating Wire Sensor Connection (Fig 2) The following diagram details the operations of the differential input version of the VibWire-108. Figure 1 shows the component parts used to make up VibWire-108. An analogue data acquisition interface built into the instrument is used to read the temperature/analogue input signals. A a singled ended input system is available and works in exactly the same however there is no differential input amplifier Sensor Excitation The VibWire-108 initialises any vibrating wire sensor by first sending an excitation pulse of around 200 micro-seconds at 8V amplitude to the sensor coil and forces it to vibrate. The coil is excited and is forced to oscillate at its natural frequency and so produces an echo pulse that is transmitted back to the instrument. The natural frequency of the sensor is determined by the physical properties of the coil and so the physical properties of the sensor used to make an investigation.. The initial start oscillations of the sensor coil is ignored and the echo signal then measured repeatedly over 100 oscillations for a period of 2 seconds and the average value reported. Ensemble averaging the results over a number of measurement cycles reduces false peaks and noise that may contribute errors to the true sensor signal. The phased locked loop is used to lock the phase and frequency of the sensor excitation signal to that of the echo signal received from the sensor. Each subsequent ping to the sensor are in phase the the previous echo and as such always act to add to the amplitude of the signal, See Fig 3. In this way the VibWire-108 only uses a minimum amount of energy to excite the sensor. The sensor coil oscillates at it s natural frequency and this depend upon the physical conditions into which it is exherted. Excitation F Excit There are little unwanted harmonics in the echo signal and these fade quickly after the first few oscillations. The echo signal settles to a sinusoidal signal that is measured by the frequency counter. Fig 3 Time Excitation Pulse in phase with echo As the excitation signal follows the natural frequency there is little added noise from unwanted harmonics that can in worst case distort frequency measurement. Signals in the order of a few millivolts are all that are needed to make a measurement. Common Mode Rejection The VibWire-108 uses a high quality differential amplifier to connect the vibrating wire sensor to the precision frequency counter. The differential amplifier removes common mode signals such as 50/60 Hz mains pickup etc. A digital filter used in collaboration with a low and high pass filter is used to condition the sensor signal before it is measured by the frequency counter. The analogue filters are set at 100 Hz and 10KHz respectively and remove the out of band signals. Differential Input Sensor Connection Figure 3 shows how a vibrating wire sensor is connected to the differential input of the VibWire-108. The shield supplied within some cable is used when noise pickup is a problem and is terminated at the connector shown. The shield can also be terminated at any Gnd point within the instrument and the effect will be the same. The vibrating wire sensors are connected to the +Vib and -Vib inputs respectively.

Measuring Gauge Temperature Most vibrating wire sensors are susceptible to errors caused by temperature fluctuations and as such are often fitted with an embedded thermistor allowing the gauge temperature to be measured. The VibWire-108 uses an analogue data acquisition system to make the temperature reading. A precision 2.5V volt regulated supply along with a 3.3K Ohm resistor completes the bridge circuit to the sensor, see figure 4. Any resistive temperature sensor can be used with the instrument however conversion to engineering units is undertaken is a feature of the analysis software of a logger or PC and is not part of the embedded software. The VibWire-108 contains 8 analogue inputs suitable for digitising the temperature sensor signals or configured as analogue inputs. The instrument does not itself undertake any linearisation or display results in engineering units, it simply makes an analogue measurement and transmits the information for later processing to a logger or computer. Any conversion of the temperature measurement into engineering units is a function of the logger unit or analysis software on the computer system. ADC 3.3K Ohm Precision Resistor + 2.5 V Precision Source Thermistor Fig 4 Range Tests It is impractical to to test the VibWire-108 in place with physical amounts of cable due to the physical problems involved in obtaining and manipulating such large objects. To get around this problem Keynes assembled an in-line simulator that combines all the same electrical properties of cable in a small easy to use circuit. The in-line simulator was used to determine the maximum cable length that can be deployed in order that a vibrating wire sensor can reliably return signals back to the instrument. Cable Type Model Keynes chose Category 5 cable for the line simulator model as this cable type is available as standard product internationally and is of a lower specification than standard instrumentation cable. Any practical deployment using good quality signal cable will offer superior results to the to those obtained 8V 200 S t Excitation Pulse 1/2 Km Equivalent line length Coil Echo + Sensor 42 H 42 H 42 H 42 H VibWire-108 55 nf 55 nf 55 nf 55 nf 100 - Sensor Coil Resistance 47 47 47 47 Fig 5 Figure 5 shows the circuit for the line simulator. To aid testing, the simulator was assembled using circuit blocks representing 1/2 km cable lengths. Figure 6 shows the excitation signal at the start and end of the line simulator. The yellow trace is the signal at the start of the simulation and the green trace at the end. Clearly shown is the distortion in the excitation signal that can occur in long cable lengths. Fig 6 - Sensor Excitation Signal Copyright Keynes Controls 2007-2008

Cable Deterioration The VibWire-108 supports sensor excitation into high impedance loads. The basic sensor coil impedance is 100 ohms as standard and can be excited even when the load reaches a level of 2K ohms ie an increase of a factor 20 in the circuit resistance. Cable type BS 6360, class 1, 2 or 5, Instrumentation cable Low voltage Construction Plain annealed copper wire conductors to BS 6360, class 1,2 or class 5, PE insulation, cores twisted into pairs or triples, each pair/triple foil screened with a drain wire, overall foil screen and drain wire, LSHF sheath Black or blue. Conductor Plain annealed copper to BS6360 class 1, 2 or class 5 Mutual Capacitance Collective screened cables except 1 & 2 pair 0.5mm² 0.75mm² 1.0mm² 1.5mm² 75pF/m 75pF/m 75pF/m 85pF/m 1 & 2 pair collective screened and all individual screened cables 0.5mm² 0.75mm² 1.0mm² 1.5mm² 115pF/m 115pF/m 115pF/m 120pF/m Resistance Ohms/Km 36 24.5 18.1 12.1 Deterioration before signal failure 0.036 mm² Category 5 Cable Low quality cable as used in the line simulator Mechanical Data Inner Conductor Deterioration before signal failure 0.52 mm² plain copper 0.09 mm² Electrical Data Capacitance(s) : 55nF/Km. Inner Conductor(s) : 94 ohms/km. Velocity Ratio : 76%. Results For example a BS6360 type instrumentation cable of length 4 km and cross sectional area 0.5 mm 2 will have to reduce 0.036 mm 2 i ie to 7.2% over its original diameter before there is a failure. When shorter sensor cable lengths are involved a cable diameter smaller than 0.036 mm 2 will still maintain instrument readings. Sensor Life Vibrating wire sensors only have a finite life and the lower the strain put onto the sensor coil the longer it will operate before failure. The Keynes control sensor excitation provides a very good compromise between sensor wear and signal strength echo response. Using a lower excitation signal but with the energy concentrated at resonance frequency ensure that the VibWire-108 produces results with the same accuracy as much more expensive brute force excitation systems.

50m line test Figure 7 shows a sample of results taken using a sensor cable length of only 50m. Clearly shown are the 0.1 Hz steps that is the maximum resolution for which the instrument can resolve. The measurements are very stable and suitable for any application. 4 Km Line simulation with 500 Ohm Load Fig 7 Figure 8 shows a series of measurements taken from the line simulator when the cable resistance has been increased to 500 Ohms. The results are satisfactory and the increased variation of the data being caused in part by the thermal effects on the various components of the circuit. 4 Km line test with 2K Ohm Load Fig 8 Figure 9 shows a series of measurements when the line simulator resistance is increased to to 2 K Ohm ie 20 times that of a normal 4 Km circuit using category 5 cable. The results show that the VibWire-108 maintains its reading even when a sensor cable deteriorates considerably as occurs in most systems over time. Fig 9

Advantages No Vibrating Wire Sensor Configuration Parameters Any Manufacturers Sensor High Operating Frequency Minimised Sensor Wear High Signal / Noise Ratio Ensemble Averaged Results over multiple measurement cycles No false peaks Automatic frequency tracking for excitation signal Temperature Compensation/ analogue 0-2.5V DC support. High impedance circuit support High Reliability for sensor cable deterioration The only user configuration options associated with the use of the Vibrating wire sensor operations are the jumper settings used to assign the analogue input signal type and a User assigned parameter used to set the number of channels to scan. The greater the sensors being used the slower it takes for the slower it takes for the instrument to respond. Maintaining the sensor excitation signal at resonance and in phase to the sensor echo signal ensures a good quality results from the sensors even when there is cable deterioration between the sensor and interface. Disadvantages Cable length restriction to 4Km (12,000 ft) Long cable lengths above 4Km are not possible due to the propagation delay in transmitting the excitation pulse to the sensor. The propagation delay can cause the excitation pulse to be out of phase with the echo and act to reduce the over all signal amplitude. Keynes controls have cable free systems that can get over the range problem and will do this at a lower cost than installing and maintaining long cable systems installations. Conclusion The VibWire-108 is very simple to operate and does not require prior knowledge of the vibrating wire sensor or operating conditions in order to make a measurement. The instrument supports high impedance sensor circuit loads and will operate correctly even when the line resistance increases considerably above that of the sensor coil. This means that for most practical deployments cable reduction due to damage will have little if any effect on the overall measurements.