AF-4 Grooved Flange Adapter

Similar documents
Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe

Pipe Restrainers series C Restrainers for use on IPEX Bionax AWWA CI OD C909 PVCO Pipe with MJ or Push-On Fittings

I-W07/W77. Couplings DETAIL A WARNING. Photo Showing Pipe with Weld Seam Ground 6 inches/152 mm Back from Pipe End and an AGS Groove

Figure 11 Flange Adapter and Back-Up Ring

INSTALLATION MANUAL FOR STAINLESS STEEL, GROOVE-END, FLEXIBLE COUPLINGS

SYGEF Standard SYGEF Plus PVDF Flanges

Section COUPLINGS AND COUPLING ADAPTERS. This Section covers couplings and coupling adapters for ductile iron and steel pipe.

SUBMITTAL INFORMATION "BOLTS, NUTS AND FLAT WASHERS" "ABSTRACT OF ASTM A307 GRADE A AND B" CARBON STEEL BOLTS AND STUDS, 60,000 PSI TENSILE STRENGTH

SPECIFICATION STEEL COUPLING MODEL 411

4.2 - PUMP MAINTENANCE MODELS: AC, AS, WC, WS

The Redi-Flange Method. How It Works. Services. Engineering & Costing Assistance

Pipe Restraints and Adapter Flanges. Section U. For PVC, Ductile Iron and Steel Pipe. 09/2017 Web Revision

4-8 HSF 250 Patriot. Line Stop Fitting Installation Instructions. Installation Instructions and Best Practices continued on back

ONE-LOK Series SLC/SLCE Pipe Restraint for AWWA C909 PVC Pipe

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

This specification describes the minimum requirements for piping systems for the following service:

SEALING METHODS AND HARDWARE FOR EQUIPMENT AND PROCESSES APRIL 11-12, 2018

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

4.4 PUMP MAINTENANCE MODELS: DB, DC, DF, DG, DJ, DL

This specification describes the minimum requirements for piping systems for the following service:

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

Fluid Sealing Association

This specification describes the minimum requirements for piping systems for the following service:

RBP-1215B-RX DODGE RAM QUAD CAB RX3

GENERAL PROVISIONS OF THE SPECIFICATIONS MATERIAL SPECIFICATIONS LIST

Yoke Type Hinged Closures Installation, Operation & Maintenance

Repair Manual 12 PL PILOT

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections

TYPE 5610 & 5610Q SINGLE O-RING CARTRIDGE SEAL

Tuf-Lite II Fans H Hi Temp 3000HT Series Hub

Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS

FIELD LOK 350. Gasket 4" 24" JOINT RESTRAINT NSF FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS. Certified to ANSI/NSF 61

.1 Materials and installation for steel piping, valves and fittings for hydronic systems in building services piping..2 Related Sections.

25000 Series Lo-T TM Butterfly Control Valve Instructions

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extension Sections. Reliable Connections

(6) Plastic Retainers. Passenger/Right. Passenger/Right Support Brackets

(2) 12mm x 40mm Bolt Plate (long) pictured w/plastic retainer. (6) 12mm x 40mm Bolt Plate (short) Support Bracket Driver/left Front

This specification describes the minimum requirements for piping systems for the following service:

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub

(W) INSTALLATION INSTRUCTIONS 3" ROUND & 4" OVAL SIDEBAR (90-DEG BENT END) DODGE RAM 1500 QUAD CAB PART #DZ /DZ /DZ /DZ

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

Fisher 667 Diaphragm Actuators Size 80 and 100

Tuf-Lite II Fans 3000H Series Hub

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.

Tuf-Lite III Fans K Hi Temp 3000KHT Series Hub

Toyota 4 Runner and Lexus GX Skid Plate installation instructions.

TYPE 3740/3740D WET/DRY RUNNING CARTRIDGE SPLIT SEAL

INSTALLATION INSTRUCTIONS PART#:17A045200MSS\17A045200MA MODULAR GRILL GUARD FOR FORD SUPER DUTY F250/F

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub

MSR/MSB Mechanical Setting Tool

Planning, storage, installation and maintenance instructions for rubber expansion joints

Before assembly is started, all working surfaces shall be cleaned and visually examined.

DYNATRAC BALL JOINT REBUILD INSTRUCTIONS V5.0

Installation, Operation, Inspection and Maintenance Manual

Passenger/Right Center and Rear Support Brackets. Driver/Left Center and

INSTALLATION INSTRUCTIONS 6 OVAL BENT END SIDEBARS DODGE RAM 1500, CREW CAB PART#: /241533B

Tuf-Lite II Fans 3000H Series Hub

TYPE 3740XL EXTRA LARGE WET RUNNING CARTRIDGE SPLIT SEAL

Tuf-Lite III Fans 3000K Series Hub

SECTION METAL FABRICATIONS

Tuf-Lite II Fans 3000HC Series Hub

Repair Instructions. Durametallic PSS III. Experience In Motion. Split Seal

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

MM750 Installation Instructions

MSR/MSB Mechanical Setting Tool

Tuf-Lite III Fans 5000K Series Hub

NTTC Tank Truck Week Awareness Gaskets/Fasteners/Flanges

SERVICE INSTRUCTIONS Model 9670 Lubricant Pump

DYNATRAC BALL JOINT REBUILD INSTRUCTIONS V4.0

TOOLING COMPONENTS. Clamping Kits Step Blocks & Kits Driver Studs Bolts, Screws Nuts, Washers...

GUIDELINES FOR HINGED AND BOLTED MANWAY ASSEMBLY

PROSTEER BALL JOINT REBUILD INSTRUCTIONS V1.0

Installation Instructions

IX. FLARED JOINTS IX. FLARED JOINTS

METRIC FASTENERS 1520 METRIC FASTENERS

LORON SERVICE MANUAL / PARTS LIST SINGLE DOUBLE PALLET HANDLER CONTENTS: PAGE 1 Lift Truck Requirements General Installation Procedures

Joint Preparation prior to Tensioning: General:

Thru Wall Floor Seals For New Installation

INSTALLATION INSTRUCTIONS 3 ROUND & 4 OVAL SIDEBAR (90-DEG BENT END) DODGE RAM MEGA CAB PART NUMBER SB1214S SB1214B

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

DRIVE COMPONENTS REMOVAL. 9. FXCW/C: see Figure Remove bolt (9), sprocket retainer (8), and thrust washer (7). NOTE PRIMARY DRIVE LOCKING TOOL

MALEKO WALL-MOUNT FAUCET INSTALLATION

REPAIR INSTRUCTIONS. Cat. No Cat. No MILWAUKEE ELECTRIC TOOL CORPORATION. SDS Max Demolition Hammer. SDS Max Rotary Hammer

Section 2. AMERICAN Pipe Joints

American Safe Room. Explosion Resistant Blast Hatch with Integrated Riser

Click Here to Go Back

Before returning this product to the store of purchase

MAINTENANCE CLEANING. MECHANICAL SEAL REPLACEMENT Refer to figures 1 and 2. SHIM ADJUSTMENT

Joint Restraints/ Bell & Spigot Joint/ New & In-Service Installations (2" IPS PVC Pipe)

Support. (3)Passenger Support. Brackets. (2) Running Board (example only)

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to "ORDER LENGTH" codes B through F; code A has 22" adjustment.

TYPE 3710 CARTRIDGE SPLIT SEAL

Installation Instructions

SECTION SHEET METAL FLASHING AND TRIM

Yoke Type Hinged Closures Installation, Operation & Maintenance

Big Block Installation Manual For Systems without A/C

INSTALLATION INSTRUCTIONS

Transcription:

SUBMITTAL INFORMATION PROJECT NAME: ENGINEER: CONTRACTOR: SPEC. SECTION: MEMBER FEATURES & ADVANTAGES Designed for connecting ANSI/AWWA C110/A21.10 and ASME/ANSI B16.1 Class 125/ flanged end components to grooved end ductile iron piping systems per ANSI/AWWA C606. 3" -12" sizes are UL, ULC listed and Factory Mutual Approved. MATERIAL SPECIFICATIONS Housing: Ductile Iron per ASTM A536 Grade 65-45-12. Finish: Rust inhibiting primer. LATCH BOLT/NUT OPTIONS (Please check one): Standard: Oval neck track bolt and heavy hex nut per ANSI/ASME B18.10 and B18.2.2. Optional: Stainless steel hex head bolts per ASTM A 193, grade B8M, class 2, type 316 & stainless steel heavy hex nut per ASTM A 194, grade 8M, type 316. GASKET OPTIONS PER ASTM D2000 (Please check one): Stanard: Halogenated Butyl Temperature range -20 F to +200 F (-29 C to +93 C). Recommended for water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. Not recommended for petroleum services. Optional: Nitrile Temperature range -20 F to +180 F (-29 C to +82 C). Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range, not recommended for hot dry air over +140 F and water over + F. Page 1

TECHNICAL INFORMATION 3" - 12" Size 14" - " Size Mating flange required Sealing area (shading) Please check sizes: AF-4 AWWA GROOVED FLANGE ADAPTER NOM. SIZE 3 80 ACTUAL PIPE SIZE 3.96 100.6 MAX WORKING (PSI)/(kPa) MAX END LOAD (LBS)/(N) 3079 13696 ASSEMBLY BOLTS LATCH BOLTS DIMENSIONS APPROX WT. QTY. SIZE QTY. SIZE A B C D MAX. MIN. BORE E SURFACE F (LBS)/(KG) 4 5/8 X 3 1 3/8 X 3 1/4 7.50 191 9.47 1 6.00 152 0.94 3.96 101 4.94 125 6 2.7 4 100 4.80 121.9 45 201 8 5/8 X 3 1 3/8 X 3 1/4 9.00 229 11.01 280 7.50 191 0.94 4.80 122 5.88 149 8 3.6 6 6.90 175.3 9348 41582 8 3/4 X 3 1/2 1 3/8 X 3 1/4 11.00 279 13.04 331 9.50 1 1.03 26 6.90 175 8.00 203 10 4.5 8 200 9.05 229.9 16082 71536 8 3/4 X 3 1/2 1 3/8 X 3 1/4 13.50 343 15.49 393 11.75 298 1.13 29 9.05 230 10.13 257 15 6.8 10 11.10 281.9 192 107611 12 7/8 X 4 1 1/2 X 4 16.00 406 18.49 470 14.25 352 1.19 30 11.10 282 12.50 318 19 8.6 12 300 13.20 335.3 34212 152183 12 7/8 X 4 1 1/2 X 4 19.00 483 21.52 547 17.00 432 1.25 32 13.20 335 14.75 375 28 12.7 14 350 15.30 388.6 200 1379 36771 163566 12 1 X 4 1/4 4 5/8 X 3 1/2 21.00 533.63 626 18.75 476 1.50 38 15.30 389 16.54 420 46 20.9 16 400 17.40 442.0 35668 158659 16 1 X 4 3/4 4 5/8 X 3 1/2 23.50 597 27.26 692 21.25 540 1.88 48 17.40 442 18.64 473 67 30.4 18 450 19.50 495.3 44797 199267 16 1 1/8 X 5 1/2 4 3/4 X 4 1/4 25.00 635 29.14 740 22.75 578 2.25 57 19.50 495 20.74 527 84 38.1 20 500 21.60 548.6 54965 4497 20 1 1/8 X 5 3/4 4 3/4 X 4 1/4 27.50 699 31.64 804 25.00 635 2.38 61 21.60 549 22.84 580 105 47.6 600 25.80 655.3 78419 348825 20 1 1/4 X 6 1/4 4 3/4 X 5 32.00 813 36.14 918 29.50 749 2.50 64 25.80 655 27.04 687 132 59.9 *All dimensions in black text are in inches except where indicated. *All dimensions in blue text (below number) are in millimeters except where indicated. The effective sealing area of the mating flange must be free from gouges or deformities of any type to ensure proper gasket sealing. Working pressure and/or end load are total allowable. One time field test pressure may be increased to 1.5 times the figures listed above. Required flange bolts to be supplied by installer. Using AF-4 Flanges as anchor points for tie rods across joints that are not restrained is prohibited. When using wafer or lug-type valves to join fittings, verify disc dimensions to make sure adequate clearance is available. The hinge points / latch bolt locations must be staggered, and a flange washer (3"-12") or transition ring (14"-") must be used when mating two AF-4 Flanges.h AF-4 Flanges require a smooth flat sealing surface. Some applications do not provide an adequate sealing surface. In these cases, a metal flange washer must be inserted between the AF-4 flange and the component. Example: When joining rubber lined or rubber faced flanges or wafer valves. When flanges, wafer check valves, etc. have a larger bore that does not allow enough sealing surface or if the flange face has an insert. Page 2

FLANGE ADAPTER INSTALLATION INSTRUCTIONS - SIZES 3"-12" 1. Check pipe end for proper groove dimensions and assure that pipe end is free of indentations and projections which would prevent proper sealing of the Grooved Flange Adapter gasket. 2. Loosen the nut on the end of the latch bolt (It should not be necessary to remove the nut completely). Swing the latch bolt out of the slot. Open Grooved Flange Adapter and place around the grooved pipe end with the key section fitting into the groove. The flange gasket cavity must face the pipe end. 5. Stretch the gasket around the pipe end and press the gasket into the cavity between the pipe O.D. and flange. The gasket must be properly positioned as shown above. 6. With gasket in place, apply lubricant to the exposed gasket lip which will seal against the mating flange. 3. Place the latch bolt back into the slotted hole. Tighten the nut until the flange halves make complete contact with each other. Alternately, the latch bolt nut may be left without fully tightening so as to provide more space for ease of gasket insertion. After the gasket is properly positioned in the cavity, tighten the nut for complete contact of flange halves making sure that there is no gasket pinch between the two halves. 7. Check to assure that the mating flange face is hard, flat and smooth. The effective sealing area of the mating flange (see table, page 4) must be free from gouges or deformities of any type to ensure proper sealing of the gasket. Align Grooved Flange Adapter holes with the mating flange, pump, tank, etc.., bolt holes and insert standard flange bolts or studs (not supplied). NOTE: Make sure that the gasket lip is not bent backwards or pinched between the two flanges. 4. Check the gasket for any deformation or cuts then lubricate the entire surface of the gasket and the flange gasket cavity using a nonpetroleum base, non - toxic gasket lubricant. 8. Evenly tighten the nuts alternately on opposite sides until flange faces contact firmly and required torque is obtained. Page 3

INSTALLATION INSTRUCTIONS - SIZES 14"-" STEP 1 STEP 2 STEP 3 Inspect pipe end for proper groove dimensions and assure pipe end is free of indentations and projections which would prevent proper sealing of gasket. Also check mating flange sealing area making sure it is free from indentations and other deformities. Refer to table on page 4 for mating flange sealing area data. Place one segment onto the grooved pipe end being sure that key section engages the groove and gasket cavity faces towards mating flange. Add other segments sequentially with latch bolts loose enough to permit rotation for bolt hole alignment. STEP 4 STEP 5 STEP 6 Rotate grooved flange adapter as required to line up with the holes in the mating flange. Check gasket supplied for any deformities or cuts, then apply a non-petroleum base, non-toxic gasket lubricant to inside and outside surface of gasket. Stretch gasket around pipe end and press it into cavity between pipe O.D. and flange. The gasket must be properly positioned as shown above. STEP 7 STEP 8 STEP 9 Insert four flange bolts (not supplied) at the segment s lap joints and direct them into adjoining flange and hand tighten nuts onto the four bolts. NOTE: Tighten four latch bolts to approximately LB-FT torque. Add remaining flange bolts (not supplied) and evenly tighten all to the recommended torque as shown below. 14" & 16" - to 300 lb-ft 18" & 20" - 300 to 350 lb-ft " - 350 to 400 lb-ft Do not over tighten the flange bolts. It is not necessary to bring the flange adapter face to face with mating flange. A gap of approximately 1/8" between flanges is normal. Page 4

Gasket Selection Guide INFORMATION The following recommendations are to assist in the selection of gasket compounds to suit particular applications. The data furnished is based upon the best information available and data supplied by producers of basic copolymer materials and leading rubber molders and manufacturers. This information is to be used as a guide and is based on average conditions. Many other factors in actual service conditions must be considered in making a final selection. Selecting the proper elastomeric compound for a specific application is largely a matter of making the best possible match between compound capabilities and service conditions. Sometimes compromises must be made, but usually a compound can be identified that meets all the specifications. For specific application conditions and selection assistance, contact Star Pipe Products. STANDARD GASKETS TYPE TEMPERATURE RANGE COMPOUND COLOR CODE GENERAL RECOMMENDATIONS M -20 F to 200 F Halogenated Butyl Brown Recommended for hot and cold water within specified temperature range. Also for a variety of dilute acids, vegetable oils, air and other chemicals not involving any petroleum or hydrocarbons. NOT RECOMMENDED FOR PETROLEUM OR HYDROCARBON SERVICE. SPECIAL GASKETS TYPE TEMPERATURE RANGE COMPOUND COLOR CODE GENERAL RECOMMENDATIONS B -20 F to 160 F SBR None L -30 F to 350 F Silicone Red Gasket Recommended for most general applications involving water within specified temperature range. NOT RECOMMENDED FOR PETROLEUM OR HYDROCARBON SERVICE. Recommended for dry heat, air, oxygen, ozone and other applications involving extremes in temperature. O 0 F to 300 F Fluro-Carbon (Viton )* Blue Recommended for most solvents, aromatics, mineral and synthetic oils and oxidizing acids. S -20 F to 180 F Nitrile (Buna N) Red Recommended for most general applications involving petroleum products, vegetable oils, mineral oils and air with oil vapors; except hot dry air over 140 F and water over F. *Viton is a registered trademark of Dupont Company AC-9 Flush Gasket 3" - 36" AF-4 Flange 3" - 12" AF-4 Flange 14" - " Page 5