PROFLY / PROBLADE Professional Radio Control PRO-BLADE8

Similar documents
PRO Professional Radio Control Series Applications

Modular Radio Telemetry System

Modular Radio Telemetry System

200, 201 Series Radio Telemetry Transmitters

FIREFLY FIREBLADE RADIO REMOTE CONTROL SYSTEMS. Applications

118, 128, KEELOQ REMOTE CONTROL SYSTEMS, 12 / 24Vdc,

VIPER Remote Control Systems

DatasheetDirect.com. Visit to get your free datasheets. This datasheet has been downloaded by

Radio Encoder / Decoder IC s

HORNET Remote Control Systems

AM / FM RADIO TRANSMITTER KEYFOBS

Remote Switching. Remote Gates. Paging.

Remote Switching. Remote Gates. Paging.

SABRETrap Control. Description

RF RECEIVER DECODER RDF1. Features Complete FM Receiver and Decoder. Applications

Trap Series. Features: Description. Technologically Advanced: 2Km Range Protective Rubber Boot 1, 4 and 16 Switch versions

MINIATURE AM / FM DECODER MODULES

SmartRadio Transmitter / Receiver

FM Radio Transmitter & Receiver Modules

FM Radio Transmitter & Receiver Modules

KAPPA-T868SO. Smart Radio Telemetry Module

ALPHA Encoder / Decoder IC s

QM Radio Transmitter Module

SmartRadio control system

DUAL BAND FM WIRELESS TRANSCEIVER RXQ1. Applications

FM 433MHz Narrow Band

BRAVO. SmartRadio Telemetry Module

TRXQ1 RXQ1 FM NARROW BAND TRANSCEIVERS. RXQ1 Version. Applications. TRXQ1 Version

FM-RRFQ SERIES FM TRANSMITTER & RECEIVER HYBRID MODULES. Transmitter. Receiver. Applications

Radio receivers type DB317 and DBR1-M4

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

SMARTALPHA RF TRANSCEIVER

FM-RTFQ SERIES FM-RRFQ SERIES FM TRANSMITTER & RECEIVER HYBRID MODULES. Transmitter. Receiver. Applications

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED. READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

RF Remote Control Unit SEAV

FM TRANSMITTER & RECEIVER MODULES. (2ND GENERATION) FM-TX2-XXX FM-RX2-XXX FEATURES. Receiver - RX2. Transmitter - TX2. Description

ELSEMA 1-Channel 433MHz Receiver with 16A Relay Output- GLR

P700WLS IoProx Receiver

Operating Instructions

SF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

FOBBER - FM Key Fob. Description. FM (FSK) Key fob Sleek and compact design Range up to 200metres 1-8 Switch variants 433 / 868MHz Options

FMR ELSEMA 2-Channel 151MHz Receiver - FMR15102

Blue Point Engineering Inc.

OEM KEYFOB TRANSMITTER DATA GUIDE

WLS-5500 Receiver (KSF & W26)

RF / IR Encoder / Decoder Chipset RF Eval2 Board, (SA123)

bhi bhi Sound Engineering Solutions from bhi Sound Engineering Solutions NEDSP1061-PCB bhi ltd 22 Woolven Close Burgess Hill West Sussex RH15 9RR

INSTRUCTION MANUAL PLUG AND SEND WIRELESS MONITOR SYSTEM TABLE OF CONTENTS

Blue Point Engineering Inc.

Arduino Arduino RF Shield. Zulu 2km Radio Link.

FMR ELSEMA 1-Channel 151MHz Receiver - FMR15101

Radio Control Installation and Operating Instructions System 4

P700-WLS ioprox Receiver

G703. Installation instructions. residential gate opener for sliding gates. remote control openers security at your fingertips

FMR MHz Receiver with Two Relay Outputs

bhi bhi DSP Noise Cancelling Products DSP Noise Cancelling Products NEDSP1061-PCB bhi ltd PO Box 318 Burgess Hill West Sussex RH15 9NR

IMPULSES RADIO TRANSMISSION SYSTEM HL 630

eguard EG2233, EG3333, EG3355, EG3388 & EG8406: Installation and Set-up Procedures Tx 2200 and Rx 4200 Boards

ELSEMA 1,2,3,4,8 -Channel 433MHz GIGALINK Transmitter GLT43300,GLT43301,GLT43302,GLT43303,GLT43304,GLT43308

105 SERIES REMOTE RECEIVER DECODERS

IMPORTANT! Please take the time to read through the manual before you start to install/program your equipment.

HL 670 Data / Impulse Transmitter set User Manual. Version 07/2010

Videowave Wireless Video & Telemetry VTX1394SED & VRX1394SED

ELSEMA GLR Applications Automatic gates. Security systems. Timer controlled outputs. Simple on/off functions.

MODEL NC221 MOBILE TWO-TONE SEQUENTIAL DECODER INSTRUCTION MANUAL

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

Revision RK-433-RC USER S MANUAL

Transmitters & Receivers

Installation instructions

MCR91501R 1-Channel, 915MHz Receiver with Frequency Hopping

7006 Loop Mate 1 Loop / Voltage / Current Simulator

Specification for Lightning Sensor

Blue Point Engineering

Fuzzy Temperature Controllers E5AF

SPA WIRELESS SWITCHES AND RECEIVERS MANUAL

SR3400 Base Station Module Configuration and Use Series-2 Cards Only

Lazerpoint RF RX-92 Full-Function Receiver Installation Instructions

RF / IR Encoder / Decoder Chipset RF Evaluation Boards,

HURRICANE Radio Modem. FULL DUPLEX Radio MODEM

User Manual March 2008

Door Monitoring and Alarms

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Wiring Instructions for 10, 16 & 20 Function, 92 & 93 Series, FET Receivers.

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

PLUG N PLAY WATT DIGITAL FM TRANSMITTER. April, 2002 IM No

User Manual. ProRF Encoder Transmitter & Receiver

OEM HANDHELD TRANSMITTER DATA GUIDE

User s Guide Instructions for Installation and Operation

TIM-018 Mk2. London Electronics Limited. Triple output loop splitter. Connection details and general information

LAZERPOINT RF WIRELESS DOOR ACTIVATION SYSTEM

Operating manual. Radio remote V.5. a Look Solutions 1 product

Installation Notes. SCR Single Channel

LAZERPOINT RF WIRELESS DOOR ACTIVATION SYSTEM

Sound Engineering Solutions

Short form User Manual

INSTALLATION & OPERATION MANUAL

Transcription:

PRO-BLADE8 Ready to Use Remote Control 8 Channel Systems Range: PROFLY Up to 100 metres PROBLADE Up to 500 metres Relay Outputs: Momentary, Latching, Timed Receiver IP65 Applications Lighting Control General Purpose Remote Switching Door Control Industrial remote Switching Access Control The PRO series are general purpose remote control systems that uses a highly secure transmission protocol for reliable operation. The receiver unit is IP65 rated with integral power supply containing industrial standard DIN Rail receiver and relay output modules (interchangeable). Modules with higher switching capability are also available separately. The relay outputs may be user set to operate as latching or momentary. Output 1 may be timed from 1-15 minutes. Additional transmitters can be added using the easy learn procedure. Any transmitter switch can be mapped to any individual or combination of receiver output(s). DS-PROBLADE-1 Oct 07 2007 RF Solutions Ltd, www.rfsolutions.co.uk Page 1

Custom systems We regularly supply pre-wired / bespoke systems; please contact our sales department for further assistance Receiver Unit The receiver consists of interchangeable modules which are connected via ribbon cables. (as shown below) Antenna The Antenna is held internally, this is to save drilling the enclosure on the top. This may have some effect to the range for specific applications which may require the antenna externally mounted. At all times please ensure that the antenna is pointing in a vertical direction and away from high interference sources. PROFLY / PROBLADE 8 CHANNEL RECEIVER Ordering Information Part Number Description Range** (Metres) Freq (MHz) Relay Outputs (each @230Vac) PROFLY8 8 channel Remote Control System 100 434.92 8 x 12A PROFLY16 16 channel Remote Control System 100 434.92 16 x 12A PRO-BLADE8 8 channel Remote Control System 500 434.525 8 x 12A PRO-BLADE16 16 channel Remote Control System 500 434.525 16 x 12A ** Range stated is optimum, direct line of sight. In worst conditions this can be reduced significantly Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such information. Use of R.F.Solutions as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd. DS-PROBLADE-1 Oct 07 2007 RF Solutions Ltd, www.rfsolutions.co.uk Page 2

1 Pre-Configuring the Remote Control System There are three Steps: 1. Pre-Configure the 210Rx to operate with a type of Transmitter 2. Map the Transmitter(s) switch(es) to the 210Rx output(s) 3. Set the 210Rx outputs to be latching, momentary or timed. 1.1 Pre-Configure the 210Rx to operate with a Transmitter Series 1. Ensure option link J8 is open. 2. Apply power to the 210Rx, All output LEDS flash alternately. This is factory reset default state. 3. Briefly Press any switch on the transmitter. The 210Rx will now confirm this by flashing LED 1 to show it is configured for use with a handheld transmitter. Note: This will now happen at each power on. DS-PROBLADE-1 Oct 07 2007 RF Solutions Ltd, www.rfsolutions.co.uk Page 3

1.2 Mapping a Transmitter Switch to a 210 Receiver Output One or many transmitter switches may be mapped to one or many 210Rx outputs. Decide which switch on the Transmitter is to operate which output channel on the 210 receiver/decoder. 1. Press the 210 Rx learn switch until the led lights the desired output channel. 2. Operate the desired transmitter switch briefly 3. The LED on the 210Rx will extinguish. 4. Operate the desired transmitter switch briefly again 5. The LED on the 210Rx will turn on briefly and then extinguish. 6. The selected transmitter switch will operate the 210Rx output channel. This procedure may be repeated for each transmitter and each 210Rx output required. 1.3 Configuration of the 210Rx Receiver Decoder Outputs Option links LK 1-16 configure the operation of the outputs. Please note that the link status is read only on power up and thus after changing the links, power must be removed and re-applied. LK 1 16 Output 1 Outputs 2-16 Open Mom or Timed Mom (The O/P operates for as long as the transmitter switch is held on) Connected Latch or Timed Latch (The O/P changes state each time the Transmitter is operated) 1.3.1 Setting the Timed output (Channel 1) This is set by VR1 with a delay of from 0 to 15 minutes. To set the time delay: 1. Remove power. 2. Place a shorting link header on option link J8. 3. Apply power 4. Depress and release the learn button twice. 5. The 210Rx will then enter the time set mode 6. LED1 will illuminate, indicating that output 1 time delay is to be set. 7. Using a fine screwdriver, adjust potentiometer VR1. 8. An indication of the time delay set is shown by LED s 9-15. After setting the timed output the unit must be powered down and option link header J8 removed before it can be used. 1.4 Erasing the 210Rx Receiver Outputs (Return to Factory Default State) 1. To completely erase the 210Rx decoder s memory, press and hold the 210Rx learn switch. 2. The learn LED (LED 17) will illuminate 3. Hold the Learn switch until the learn LED extinguishes (approx 10 seconds). 4. Release the learn button and all the output LED s 1-16 will now flash alternately to indicate that all encoder data has been erased and the 210Rx has returned to factory default state. Note: It is not possible erase individual transmitters. DS-PROBLADE-1 Oct 07 2007 RF Solutions Ltd, www.rfsolutions.co.uk Page 4

1.5 Connecting output Modules to the 210 Receiver The receiver has 16 outputs. These are connected to the relay output module via a ribbon cable. The outputs are presented according to the following table. 210 receiver O/P Channels Connector 1 1-4 2 5 8 3 9 12 4 13 16 1.6 Relay Outputs Each output relay provides an isolated switch. Connections are Common (COM), Normally Open (NO), Normally Closed (NC). NC COM NO Relay Connections when Transmitter NOT Operating NC COM NO Relay Connections when Transmitter OPERATING 2 Antenna and Range 2.1 Antenna The system includes an antenna. It is situated within the enclosure (to save penetrating the enclosure) If the range is inadequate then it may be necessary to mount the antenna protruding from the enclosure. This may be easily fitted using the provided panel mount BNC socket. The antenna cable may be extended however please note that typically there is a 50% range reduction with every 3metres of coax cable used! For increasing range performance a +3dB gain antenna is available. This is supplied with wall mounting bracket and 2metres of coax cable, it plugs in directly to the BNC connector. 2.2 Range The antenna choice and position directly controls the system range. Keep it clear of other metal in the system. The best position is protruding from the top of the product. This is often not desirable for practical or ergonomic reasons and thus a compromise may be needed. If an internal antenna must be used then try to keep it away from other metal items, and in particular large ones like transformers, batteries and PCB tracks and earth planes. Note that the space around the antenna is as important as the antenna itself. All radio systems are dependant on a radio signal being received through airspace. The range quoted is the optimal in direct line of sight without obstacles and in good atmospheric conditions. 2.3 Signal integrity In systems where many encoders are in close proximity there may be occasions when, due to signal overlay between encoders, it is difficult or impossible to guarantee system integrity. In such circumstances it is the responsibility of the installer to ensure that the system performance is adequate for the purposes of the installation. DS-PROBLADE-1 Oct 07 2007 RF Solutions Ltd, www.rfsolutions.co.uk Page 5

Technical Specifications PROFLY / PROBLADE Transmitter FireBlade Dimensions Battery 90 x 54 x 27mm CR2032 Lithium Cell Receiver Unit Dimensions 315 x 235 x 130mm Insulation class II Sealed hinged lid screws DIN Rails mounted on steel plate Integrated 12Vdc moulded Power Supply 5 Amp Fused terminal block Material GW PLAST 120 C A 12Vdc power supply is incorporated. 12Vdc is presented on a fused terminal block. A Gland is supplied to enable power to enter the enclosure. Learning Capacity: Dimensions External Internal DIN Rail length 1 DIN Rail length 2 The receiver has the capacity to learn upto 50 units (Where 1 unit is defined as a button on a transmitter) 315 x 235 x 130mm 300 x 220 x 120mm 285mm 180mm Technical Specifications Input Voltage 110-240Vac Output Voltage 12Vdc +/-5% Output Current 1A Output Polarity: White Dashed Wire =+12V Storage Temperature: -10 to +70 o Celsius. Operating Temperature: 0 to +55 o Celsius. Electrical Characteristics Min Typical Max Units Supply Voltage: 12V Supply 10 12 16 V Supply Voltage: 24V Supply 21 24 30 V Supply Current : Quiescent 25 ma Time from Tx Switch depressed to 210Rx output 100 ms Time from Tx Switch release to Decoder output 200 ms Switched output Voltage (I out = 1mA) Logic Low Logic High 0 3.5 0.2 3.8 0.8 5 V V R. F. Solutions Ltd., Unit 21, Cliffe Industrial Estate, South Street, Lewes, E. Sussex, BN8 6JL, England Tel +44 (0)1273 898 000 Fax +44 (0)1273 480 661 Email sales@rfsolutions.co.uk http://www.rfsolutions.co.uk RF Solutions is a member of the Low Power Radio Association DS-PROBLADE-1 Oct 07 2007 RF Solutions Ltd, www.rfsolutions.co.uk Page 6