Power-Sure 700. Technical Data TD158001EN. Contents

Similar documents
Power Processor - Series 700F 10KVA to 150KVA

ULTRA-K Series 600K - he

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator)

TOSHIBA International Corp

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

The power to work. Power conditioning products. Harmonic correction unit Sag ride-through power conditioner

60K(i) - 260K(i) THREE PHASE. SureImage IMAGING & TREATMENT SERIES

StatiVolt. Inverter UPS Systems. Features. Contents

Liebert Datawave GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Liebert Datawave. GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System 1.0 GENERAL

SECTION THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

Power Conditioners product guide

Power Commander. Power Commander Plus. Electronic Line Voltage Regulators. 15 kva 150 kva SINGLE PHASE 15 kva 450 kva THREE PHASE SERIES 900

Harmonic mitigating transformers. Energy savings through harmonic mitigation

GUIDE SPECIFICATIONS 40-80kVA, kVA and kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

MODEL 421 Over/Under Motor Load Monitor

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

POWER QUALITY PRODUCTS FOR NON-LINEAR LOADS

PRODUCT FEATURES TYPICAL APPLICATIONS

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

Straight Isolation - Plug In (171 Series)

Strategies for design 600V large modular UPS for critical power applications

Series NRX with PXR - Instructions for Neutral Current Sensor Type NF

Harmonic mitigating transformers. Energy savings through harmonic mitigation

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

BUCK-BOOST TRANSFORMERS

VariSTAR Type AZU heavy-duty distribution-class under-oil MOV surge arrester

USER S MANUAL. 1KSS60400/ ST Edition

Design Specifications Low Voltage Active Harmonic Filter

HPS Universal BUCK-BOOST TRANSFORMERS

SECTION 16496G CONTACTOR BASED AUTOMATIC TRANSFER SWITCHES LOW VOLTAGE

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

Owner s Manual.

These true online inverters integrate pulse width modulation (PWM) control combined with high frequency IGBT power transistors.

USER S MANUAL. 3KSS6050/ nd Edition

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

TOA PROFESSIONAL POWER AMP

Est Static Frequency Converter. SFX 10kVA - 10MVA

Isolation Transformer Series

ASX SERIES PACIFIC OPERATION MANUAL AC POWER SOURCE POWER SOURCE

NGS INVERTER REPLACEMENT SCOPE OF WORK & SPECIFICATIONS

SECTION DISTRIBUTION SWITCHBOARDS

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions

Rev.8.8 SSRMAN-1P SERIES USERS MANUAL SSR INTELLIGENT PHASE ANGLE CONTROL MODULE COPYRIGHT 2015 NUWAVE TECHNOLOGIES, INC.

STATIC UNINTERRUPTIBLE POWER SYSTEM Revised 4/30/ Electrical Systems

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM

Distribution/Substation Transformer

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

G Series. Advanced Test Equipment Rentals ATEC (2832) AC Power Systems. 6 to 90 kva 45 to 5,000 Hz

Specifications. S&C BankGuard Plus Controls. For Substation Capacitor Banks and Shunt Reactors. Conditions of Sale

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

Operation Manual. Congratulations on purchasing your high quality AIMS Power pure sine inverter!

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Power Protection and Conditioning

Comparison of recloser and breaker standards

VariSTAR Type AZL heavy-duty distribution-class MOV arrester

General Description & Features Selection Charts Definition of Terms... 42

American Power Design, Inc.

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

American Power Design, Inc.

Two- and three-phase MagneX interrupter

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

Active Harmonic Filter

How to maximize reliability using an alternative distribution system for critical loads

Phoenix DX Clean Power (18 Pulse) AC Drive

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

INSTRUCTION LEAFLET IL17553B IQ UNIVERSAL POWER SENTINEL TM INSTALLATION INSTRUCTIONS FOR THE IQ UNIVERSAL POWER SENTINEL TM INTERNAL CT

The SSR P Series. Phase-Fired SCR Power Controllers. for resistive heating loads. Phase-Fired SCR Power Controllers AMPS VAC

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

SECTION AUTOMATIC TRANSFER SWITCH

35 kv Class M.O.V.E. DirectConnect elbow arrester

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

Gutor PxW AC UPS Designed for North American Market

SECTION PANELBOARDS

2006 MFJ ENTERPRISES, INC.

Grid Radar Installation Manual

AC/DC Current Oscilloscope Probe Model SL261

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

POSI-BREAK Metal Oxide Varistor Elbow (M.O.V.E.) Surge Arrester

DLVP A OPERATOR S MANUAL

UNINTERRUPTIBLE POWER SUPPLY SPECIFICATIONS MODEL 1100B SERIES

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

Premium 30 Energy Efficient, Low Voltage Transformers General Purpose, Harmonic Mitigating, and K-Rated

T S 15KVA 1PH 240/480 Transformer

Transcription:

Technical Data TD158001EN Power-Sure 700 Supersedes August 2015 Contents Description Page General description... 2 Power-Sure 700 benefits.... 2 Specifications... 3 Industry standards and certifications... 3 Theory of operation.... 4 Product selection.... 4 Technical data... 5 Component diagrams... 6 Control board.... 16 Technical diagrams... 17 Cabinet dimensions.... 30 Manual bypass switch.... 30 Normal mode.... 30 Bypass mode.... 30 Standard monitoring.... 30 Metering option.... 30 Warranty... 30

Technical Data TD158001EN IMPORTANT Save these instructions. Please read this manual before using equipment. General description The Power-SureE 700 is a continuous duty electronic voltage regulator designed to supply reliable, clean regulated power to critical loads. An efficient design with state-of-the-art microprocessor controlled solid-state devices provide immunity to all line disturbances. The basic design consists of a three-phase triple-shielded isolation transformer with seven separate voltage taps per phase. Output regulation is achieved by monitoring the input and automatically switching taps anytime the input line sags or surges. The special process of triple-shielded isolation transformers provide superior common mode and transverse mode noise attenuation. Automatic switching occurs during current zero, allowing noise-free switches for both leading and lagging power factor loads that are connected to the Power-Sure 700. Monitoring Monitoring of the Power-Sure 700 is simple, clean, and effective. Three green light indicators are used to display POWER ON (output line to neutral for each phase) and one red light indicator to display ALERT. The POWER ON display is connected directly to the output that indicates the Power-Sure 700 is operating properly with just a quick glance. The ALERT display represents an overtemp problem when illuminated and will shut down the output, but cooling fans remain on. Overtemp thermal sensors are strategically located at critical points on the regulator assemblies and transformer. The main AC input circuit breaker must be turned off in order to reset the ALERT light. Protection Protection is accomplished very effectively to minimize failures and the cost of repairs. A total of four major devices protect the Power-Sure 700. 1. The input is protected with an integrally mounted AC circuit breaker for abnormal current overloads and provides a convenient means of disconnecting utility power. 2. The electronic regulating devices are protected with fast-acting semi-conductor fuses. These fuses are designed to clear before damage occurs to the more expensive SCR regulating devices. The main transformer is protected by fuse links connecting the SCR regulators together, and are designed to clear in the event that two or more SCRs should fail. This will prevent a transformer tap short and the possibility of transformer failure. 3. Overtemp sensing devices are mounted at critical points on the SCR regulating assembly and the main transformer. When an overtemp condition exists, the ALERT light will illuminate and hold until the overtemp is corrected. There are no automatic shutoff circuits for the ALERT condition. The main AC input breaker must be turned off in order to reset the ALERT light. 4. Optional dedicated surge protective device can be installed internally if requested at time of order. This surge suppression device (SPD) is a CVX 50 ka SPD for Power-Sure 700 units 50 kva and below, and CVX 100 ka SPD for Power-Sure 700 units 75 kva and above. This unit provides effective transient voltage surge suppression and will help to prolong the life of the Power-Sure 700. Power-Sure 700 Operation The Power-Sure 700 is operated by simply turning on the main AC input circuit breaker. All units 50 kva and larger are equipped with a bypass switch as a standard feature. For units 45 kva and smaller, the bypass switch is optional. This is a no load switch and MUST only be operated when the unit is OFF. The bypass switch should be in the NORMAL position unless a problem occurs with the system. If a problem occurs, turn OFF the main AC circuit breaker and turn the bypass switch to the BYPASS position. Re-energize the system by turning on the AC circuit breaker and contact the Customer Support Department for repairs. Any ALERT condition requires the main AC input breaker to be turned off in order to reset the ALERT light. For assistance, call 1-800-809-2772, option 4, then option 2. Power-Sure 700 benefits Line harmonic filtering Small physical size Simple and inexpensive installation Highly efficient Quiet operation Low BTU output Low failure rate Seven-tap, microprocessor control and diagnostics UL Listed to 1012 standards Affordable Conservatively rated Extremely high surge capability Simple operation Input electronic circuit breakers Nationwide customer support service 2

Power-Sure 700 Specifications Technical Dynamic electrical specifications Output: maintained to within ±3% of nominal a Input: +10% to 23% of the nominal rated input a b Frequency: 60 Hz ±3 Hz a Input power factor: >0.99 PF with resistive load Line regulation: output is ±3% of nominal for input variations of +10% to 23% of nominal Load regulation: output maintained within 3% from no load to full load Response time: <1/2 cycle Correction time: output will correct to within ±3% of nominal in 1.5 cycles or less Harmonic distortion: Less than 1.0% THD added to the output waveform under any dynamic linear loading conditions presented to the line regulator Transverse-mode noise attenuation: 3 db down at 1000 Hz, 40 db/decade to below 50 db with resistive load Common-mode noise attenuation: 146 db Audible noise: 45 db or less Turn on characteristics: when energized, voltage overshoot will be less than 5% of nominal for 1 cycle or less Overload rating: 1000% for 1 cycle and 200% for 10 seconds Ambient rating: 10º to +40º Celsius Integral manual rotary maintenance bypass switch standard on 50 to 500 kva units and optional on smaller units NNote: 50 Hz models available. Main transformer Windings: all copper Technical Data TD158001EN Magnetics: grain orientated, M6 grade, stress-relieved transformer steel is used for minimum losses and maximum efficiency Insulation: Class (N) 200, all sizes Shielding: multiple triple copper shield to minimize interwinding capacitance, transient, and noise coupling between primary and secondary windings Cooling: convection, operating temperature is 130ºC maximum rise above ambient Isolation: output is fully isolated from input Cabinet Heavy-gauge industrial steel throughout. Metal is anti-corrosive phosphate treated prior to paint. Paint is a baked finish. Input breaker Main input molded-case circuit breaker, rated at 125% of full load input current. Industry standards and certifications ANSI/IEEET C57.12.91 Transformer Test Code ANSI C62.41 Category B-3 NFPA 70 National Electrical CodeT FCC Class A limits, 47 C.F.R. Part 15, Subparts A, B UL Listed to standard 1012, power supplies general purpose cult Listed to CSA standard C22.2, No. 107.1-01 NEMAT PE 1 (National Electrical Manufacturers Association) NEMA 250 (National Electrical Manufacturers Association) Enclosures for Electrical Equipment (1000 V maximum) ISOT 9001:2008 Occupational Safety & Health Administration (OSHA) Figure 1. Regulation graphs a Optional extended input regulation range provided on some units. If provided, reference the description next to the unit s specification tag. b Between 160 V and 229 V at 208 V nominal. Between 369 V and 528 V at 480 V nominal. 3

Technical Data TD158001EN Theory of operation The Power-Sure 700 provides the triple function of isolation, noise attenuation, and voltage regulation. The first two functions are provided by the power transformer, where as the third function of voltage regulation is achieved through solid-state thyristors (SCRs) connected to taps on the power transformer. A microprocessor monitors and controls the overall function of regulating the system. The power transformer is manufactured with a unique method of shielding that produces very low capacitive coupling between the primary and secondary. This low coupling provides excellent attenuation of the common-mode noise. In addition, special care is taken in the design of the transformer to attenuate transverse-mode noise above 1000 Hz. The power transformer has taps to which solid-state switches (SCRs) are connected. Power-Sure 700 The voltage regulator incorporated in the Power-Sure 700 is microprocessor controlled to achieve optimum correction time of input voltage sags and surges. The response time is typically one half (1/2) cycle for 100% correction, therefore, a very smooth switch takes place undetected by computer equipment. As the input voltage (building power) varies, the voltage available at each tap of the transformer will also change. The amount of variation is dependent upon the input sag or surge, turns ratio, and transformer losses. By selecting a particular tap voltage, the output can be kept within a tight range. The way in which this is accomplished is that an electronic control card using a microprocessor continually monitors the input voltage. When a voltage fluctuation occurs, which exceeds the limit of rated regulation (typically ±3%), the output is switched to another tap that is within the required range. This switch will be made at the next current zero crossing to allow for both leading and lagging power loads to be connected to the conditioner. Product selection Table 4. Eaton Power-Sure 700 model selection guide T - k - Nominal Input Voltage Delta Input: L, L, L, G B = 208 C = 240 H = 400 D = 480 E = 600 Nominal Output Voltage Wye Output: L, L, L, N, G L = 120/208 M = 230/400 N = 277/480 P = 347/600 kva 010 010 015 015 025 030 045 050 075 100 125 150 225 300 500 Weight (lbs) 440 520 465 700 700 720 950 1,176 1,575 2,014 2,137 2,240 3,300 4,000 5,500 BTUs/ hr Bypass Metering 1,025 1,205 1,540 1,540 2,560 3,090 4,600 7,332 9,514 11,833 14,748 17,698 23,000 30,750 51,250 Optional Optional Optional Optional Optional Optional Optional kva Ratings and Dimensions No No Cabinet Size Dimensions H x W x D in Inches (mm) 30.20 x 22.20 x 29.00 (767.1 x 563.9 x 736.6) 44.20 x 22.20 x 29.00 (1122.7 x 563.9 x 736.6) 30.20 x 22.20 x 29.00 (767.1 x 563.9 x 736.6) 44.20 x 22.20 x 29.00 (1122.7 x 563.9 x 736.6) 44.20 x 22.20 x 29.00 (1122.7 x 563.9 x 736.6) 44.20 x 22.20 x 29.00 (1122.7 x 563.9 x 736.6) 44.30 x 45.90 x 29.00 (1125.2 x 1165.9 x 736.6) 66.00 x 29.00 x 35.50 (1676.4 x 736.6 x 901.7) 76.00 x 34.40 x 35.50 (1930.4 x 873.8 x 901.7) 76.00 x 34.40 x 35.50 (1930.4 x 873.8 x 901.7) 76.00 x 34.40 x 35.50 (1930.4 x 873.8 x 901.7) 76.00 x 34.40 x 35.50 (1930.4 x 873.8 x 901.7) 77.40 x 56.00 x 41.50 (1966.0 x 1422.4 x 1054.1) 77.40 x 56.00 x 41.50 (1966.0 x 1422.4 x 1054.1) 77.00 x 72.40 x 48.40 (1955.8 x 1839.0 x 1229.4) Options 1 Blank = No options B = Bypass switch b M1 = Standard metering (IQ 130) M2 = Premium metering (IQ 150) S = Surge Frequency 6 = 60 Hz 5 = 50 Hz a Units with no surge protection option, bypass option or metering will have blanks in the last three spaces in the catalog number. b Bypass is standard on 50 kva and larger units and an option on 45 kva and smaller units. Notes Listings UL Listed, CSA Certified, except for 600 V: no UL, CSA on 600 V units. For output distribution, call factory. K factor rated units available on request. 4

Power-Sure 700 Technical Data TD158001EN Technical data Table 1. Nominal input current at various input voltages Model kva size Input voltage 208 V Input 208 V breaker size 240 V 240 V input breaker size 400 V 400 V Input breaker size 480 V 480 V Input breaker size 600 V 10 29 A 40 A 25 A 35 A 16 A 20 A 13 A 20 A 10 A 15 A 15 44 A 60 A 38 A 50 A 23 A 30 A 19 A 25 A 15 A 20 A 25 73 A 110 A 63 A 100 A 38 A 60 A 32 A 50 A 25 A 40 A 30 87 A 110 A 76 A 100 A 45 A 60 A 38 A 50 A 30 A 40 A 45 131 A 175 A 114 A 150 A 72 A 90 A 57 A 80 A 46 A 60 A 50 146 A 175 A 126 A 150 A 76 A 100 A 63 A 80 A 51 A 70 A 75 219 A 300 A 189 A 250 A 112 A 150 A 95 A 125 A 76 A 100 A 100 291 A 400 A 253 A 350 A 157 A 200 A 126 A 175 A 101 A 150 A 125 364 A 450 A 316 A 400 A 189 A 250 A 158 A 200 A 126 A 175 A 150 437 A 600 A 379 A 500 A 227 A 300 A 189 A 250 A 152 A 200 A 225 656 A 800 A 568 A 800 A 341 A 450 A 284 A 350 A 227 A 300 A 300 875 A 1200 A 758 A 1000 A 455 A 600 A 379 A 500 A 303 A 400 A 500 1457 A 2000 A 1263 A 1600 A 758 A 1000 A 631 A 800 A 505 A 700 A 600 V Input breaker size Table 2. Nominal output current at various output voltages Model Input voltage kva size 208/120 V 480/277 V 10 28 A 12 A 15 42 A 18 A 25 69 A 30 A 30 83 A 36 A 45 125 A 54 A 50 139 A 60 A 75 208 A 90 A 100 278 A 120 A 125 347 A 150 A 150 416 A 180 A 225 625 A 271 A 300 833 A 361 A 500 1388 A 602 A 5

Technical Data TD158001EN Power-Sure 700 Component diagrams 10 15 kva, 60 Hz, All Input Voltages 10 15 kva, 50 Hz, All Input Voltages and 25 30 kva, 60 Hz, All Input Voltages Figure 2. Unit 6

Power-Sure 700 Technical Data TD158001EN Figure 3. Unit component location diagram (45 150 kva, 60 Hz / 30 100 kva, 50 Hz) 7

Technical Data TD158001EN Power-Sure 700 Figure 4. Power-Sure 700 50K component location 8

Power-Sure 700 Technical Data TD158001EN Figure 5. Power-Sure 700 75 150K component location 9

Technical Data TD158001EN Power-Sure 700 Output Terminals Cabinet Cooling Fan Input Breaker & Optional Bypass Output Filtering Heatsink Assembly With Snubber Card Heatsink Assembly Cooling Fan Output Semi- Conductor Fuses Power Supply Card Control Card Multi - Shielded Isolation Transformer Left Side View Front View Right Side View Rear View Figure 6. Unit component location diagram (225 300 kva 50/60 Hz, all voltages) 10

Power-Sure 700 Technical Data TD158001EN Figure 7. Unit component location diagram (500 kva, 50 Hz and 60 Hz, all voltages) 11

Technical Data TD158001EN Power-Sure 700 Figure 8. 10 30 kva heat sink layout a a Heat sink layout does not necessarily follow kva size shown. Input voltage is also a factor in heat sink layout. 12

Power-Sure 700 Technical Data TD158001EN Figure 9. 45 150 kva heat sink layout a a Heat sink layout does not necessarily follow kva size shown. Input voltage is also a factor in heat sink layout. 13

Technical Data TD158001EN Power-Sure 700 Figure 10. 225 300 kva heat sink layout a a Heat sink layout does not necessarily follow kva size shown. Input voltage is also a factor in heat sink layout. 14

Power-Sure 700 Technical Data TD158001EN Figure 11. 500 kva heat sink layout a a Heat sink layout does not necessarily follow kva size shown. Input voltage is also a factor in heat sink layout. 15

Technical Data TD158001EN Power-Sure 700 Control board Figure 12. Control board #49120/407415 16

Power-Sure 700 Technical Data TD158001EN Technical diagrams Figure 13. Generic circuit diagram primary SCR no bypass 17

Technical Data TD158001EN Power-Sure 700 Figure 14. Generic circuit diagram primary SCR with bypass 18

Power-Sure 700 Technical Data TD158001EN Figure 15. Generic circuit diagram secondary SCR no bypass 19

Technical Data TD158001EN Power-Sure 700 Figure 16. Generic circuit diagram secondary SCR with bypass 20

Power-Sure 700 Technical Data TD158001EN Figure 17. Installation diagram Power-Sure 700 10 15 kva with optional bypass 21

Technical Data TD158001EN Power-Sure 700 Figure 18. Installation diagram Power-Sure 700 10 30 kva with optional meter and bypass 22

Power-Sure 700 Technical Data TD158001EN Figure 19. Installation diagram Power-Sure 700 45K with optional meter and bypass 23

Technical Data TD158001EN Power-Sure 700 Figure 20. Installation diagram Power-Sure 700 50K with bypass and optional meter 24

Power-Sure 700 Technical Data TD158001EN Figure 21. Installation diagram Power-Sure 700 50K with bypass and optional meter (top and bottom view) 25

Technical Data TD158001EN Power-Sure 700 Figure 22. Installation diagram Power-Sure 700 75 150K with bypass and optional meter 26

Power-Sure 700 Technical Data TD158001EN Figure 23. Installation diagram Power-Sure 700 75 150K with bypass and optional meter (top and bottom view) 27

Technical Data TD158001EN Power-Sure 700 Figure 24. Installation diagram Power-Sure 700 225 300K with bypass and optional meter 28

Power-Sure 700 Technical Data TD158001EN Figure 25. Installation diagram Power-Sure 700 500K with bypass and optional meter 29

Technical Data TD158001EN Power-Sure 700 Cabinet dimensions Table 3. Power-Sure 700 unit cabinet sizes Part number kva rating Bypass Metering Cabinet size H x W x D inches BTUs/Hr Weight (Lb) T -010k- _ 10 No 30.2 x 22.2 x 29.0 1,025 440 T -010k- _ 10 44.2 x 22.2 x 29.0 1,205 520 T -015k- _ 15 No 30.2 x 22.2 x 29.0 1,540 465 T -015k- _ 15 44.2 x 22.2 x 29.0 1,540 700 T -025k- _ 25 44.2 x 22.2 x 29.0 2,560 700 T -030k- _ 30 44.2 x 22.2 x 29.0 3,090 720 T -045k- _ 45 44.3 x 45.9 x 29.0 4,600 950 T -050k- _ 50 66.0 x 29.0 x 35.5 7,332 1,176 T -075k- _ 75 76.0 x 34.4 x 35.5 9,514 1,575 T -100k- _ 100 76.0 x 34.4 x 35.5 11,833 2,014 T -125k- _ 125 76.0 x 34.4 x 35.5 14,748 2,137 T -150k- _ 150 76.0 x 34.4 x 35.5 17,698 2,240 T -225k- _ 225 77.4 x 56.0 x 41.5 23,000 3,300 T -300k- _ 300 77.4 x 56.0 x 41.5 30,750 4,000 T -500k- _ 500 77.0 x 72.4 x 48.4 51,250 5,500 Manual bypass switch The manual bypass switch is a break-before-make switch located on the Power-Sure 700. The manual bypass switch is used to bypass all power electronics in case of failure. Bypass is standard on 50 kva and larger units and an option on 45 kva and smaller units. NNote: This switch may be added in the field. Normal mode With the switch in the normal position, the Power-Sure 700 will provide clean and regulated power to the critical loads. The Power-Sure 700 should have the switch in the normal position unless a failure has occurred. These units are sold in accordance to Eaton Selling Policy 25-000. Bypass mode With the switch in the bypass position, the Power-Sure 700 will provide clean power to the critical loads. In the bypass position, the unit will not regulate the incoming voltage. The transformer and suppression circuitry remains in the circuit when in the bypass mode. The Power-Sure 700 should be placed in the bypass position when a failure of the system has occurred. This provides the user with some protection until a service technician arrives. CAUTION Prior to switching from one position to another, turn off the AC input breaker. Some systems are equipped with push-to-turn switches. With these switches, the switch will shunt trip the input breaker when pressed in. Standard monitoring Overtemp sensing devices are mounted at critical points on the SCR regulating assembly and the main transformer. If an overtemp condition exists, the unit will electronically shut off; however, the cooling fans will continue to operate. The ALERT light will illuminate and hold until the overtemp is corrected. The main AC input breaker must be turned off in order to reset the ALERT light. Alert light An indicator light indicates if the output has been disabled by one of the following conditions: (1) Transformer over-temperature (2) SCR thermal over-temperature Indicating lamps Output ON indicating lamps are provided for each phase. Metering option The Power-Sure 700 offers two metering options. The IQ 130 meter is the standard option on the Power-Sure 700. The IQ 130 has programmable voltage, current transformer ratios, and true rms indication for accurate measurement of distorted waveforms, which can be viewed through four screens via a high visibility LED display. Installation and operation instructions for this meter can be found in Instructional Leaflet IL02601002E. The premium metering option is the IQ 150 which offers all the features of the IQ 130, along with energy, power, communications ability, and many other enhanced features. Please refer to Technical Data TD02601025E for additional information. Warranty Eaton warrants the Power-Sure 700 to be free from defects in material and workmanship for a period of one year from the shipment date. The warranty includes parts only during this time. These units are sold in accordance to Eaton Selling Policy 25-000. 30

Power-Sure 700 Technical Data TD158001EN 31

Technical Data TD158001EN Power-Sure 700 Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 2018 Eaton All Rights Reserved Printed in USA Publication No. TD158001EN / Z20791 April 2018 Eaton is a registered trademark. All other trademarks are property of their respective owners.