SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

Similar documents
SINEAX TI 807 Passive DC signal isolator

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Plug-in module SIRAX TI 807 Passive DC signal isolator

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SINEAX / EURAX 2I1 Passive DC signal isolator

SINEAX B 811 Power Pack with additional Functions

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

SINEAX U 553 Transducer for AC Voltage

SINEAX TV809, 1 channel Programmable Isolating Amplifier

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

SINEAX G 536 Phase Angle or Power Factor Transducer

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX V 604 Programmable universal transmitter

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits

KINAX 2W2 Programmable Transmitter for Angular Position

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SINEAX I 552 Transducer for AC current

Binary Output without Power Supply Series 9176

KINAX WT 717 Programmable Transmitter for Angular Position

KINAX WT 707 Transmitter for angular position

SINEAX G 537 Transducer for Phase Angle Difference

KINAX SR 719 Programmable Transmitter for Position Feedback

RISH Ducer E13 3 channel transducer for AC current and voltage

Isolators A3/1. Vibration Transducer Supply Unit Series

Binary Output Series 9175

Isolating Repeater Input Series 9163

EMBSIN 281 G Power factor transducer

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1.

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

RISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

OPTITEMP TT 10 C/R Technical Datasheet

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

SINEAX V 604s Programmable multifunctional transmitter

Temperature Transmitter itemp RTD DIN rail TMT 127

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Rail mounted Temperature Transmitter TH102/TH102-Ex

RISH Ducer E15 TRANSDUCER FOR AC CURRENT OR AC VOLTAGE WITH DIFFERENT CHARACTERISTICS

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Temperature transmitter itemp PCP DIN rail TMT 121

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

Technical Information Barrier RB223

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

Temperature Input Module for Zone 1 Series 9482/32

Rudder or propeller angular position transmitter KINAX WT720

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Contrans T TEU 471, TEU 471-Ex. Intelligent four-wire temperature transmitters EN

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

Temperature transmitter itemp RTD DIN rail TMT 127

Operating Instructions

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

SINEAX VC 603, Programmable combined transmitter/alarm unit

Temperature Transmitters TMT 136, TMT 137

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

Theta 20A / 20V. Technical Data Sheet. Special Features

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

... for hydraulic and general applications in hazardous areas

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Digital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

SALES SERVICE +358 (0)

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Inductive sensor slot-type SI2-K08-AP7

Digital Input Output Module for Zone 2 Series 9470/33

EURAX UI 505, Combined Transducer for AC current and AC voltage

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Head mounted Temperature Transmitter TF02/TF02-Ex

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Theta Hz. Technical Data Sheet. Special Features

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Fieldbus Isolating Repeater Series 9185/11

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

KINAX 3W2 Transmitter for angular position

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

OPTITEMP TT 20 Technical Datasheet

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

PRetrans Table of contents

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

itemp HART DIN rail TMT112

Assembly. Front view. Power Rail

0 2 1 â Ó. itemp HART TMT182. Technical Information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Transcription:

SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate the analogue DC signal in the range 0 20 ma which depending on version is then converted to a current or voltage signal (0 20 ma or 0 10 V). It operates passively and does not require a separate power supply, but derives the little auxiliary energy it needs from the DC signal. The series of isolators also includes intrinsically safe explosionproof versions with either an intrinsically safe input signal [EEx ib] IIC or intrinsically safe output signal [EEx ia] IIC. They are thus suitable for use in connection with intrinsically safe equipment installed in the hazardous area. The signal isolator is supplied in two different housings depending on the number of transmitter channels to be isolated SINEAX TI 807-5 with one transmitter channel to be isolated in housing Type N17 (Fig. 1) and SINEAX TI 807-1 with two or three channels in housing Type S17 (Fig. 2). Both types of housing are suitable for either rail or wall mounting. Fig. 1. SINEAX TI 807-5 with one isolation and transmission channel, in housing N17, clipped onto a top-hat rail. Features / Benefits Electrically insulated analogue DC signals 0 20 ma / Prevents the transfer of interference voltages and currents. Solves grounding problems in meshed signal networks Highly accurate / Performs its isolating function with negligible transmission error No power supply needed / Saves wiring costs and is easy to install in existing plants Available in type of protection Intrinsic safety [EEx ib] IIC or [EEx ia] IIC (see Table 6 Data on explosion protection ) Snaps onto a DIN rail or screws onto a wall or panel / Adaptable to the circumstances at the place of installation Compact and narrow. Housing only 17.5 mm wide / Low space requirement, high packing density. 27 devices fit into a 19 rack Layout and mode of operation The description below refers to SINEAX TI 807-5 with one isolation and transmission channel. The DC signal isolator comprises a DC chopper Z, an isolating stage T, a rectifier G and an oscillator O. The chopper converts the DC input signal E = 0 20 ma to an AC signal which is transformed with electrical insulation, rectified, smoothed and appears at the output as a DC current signal A = 0 20 ma (Fig., left). Versions with a DC output voltage Fig. 2. SINEAX TI 807-1 with two or three isolation and transmission channels, in housing S17, screw hole mounting brackets pulled out. signal A = 0 10 V have a resistive burden of 500 Ω through which the current flows (Fig., right). The chopper is controlled by the oscillator which obtains its power from the DC signal. E Z O T U V Fig.. Block diagram for a function unit. G A G A Camille Bauer Data sheet TI 807-5/-1 Le 01.0 1

Technical data Input signal E DC current signal I E 0 20 ma Max. permissible current 50 ma Voltage limiter Non-Ex version 27 V ± 5% (with zener diode) Ex version 18 V, ± 5% Output signal A (DC current or DC voltage) DC current signal I A Voltage drop U V 0 20 ma < 2.8 V with standard (non-ex) version <.7 V with (input signal(s) < 6. V with (output signal(s) Max. burden 1000 Ω with standard (non-ex) version 500 Ω with (input signal(s) 500 Ω with (output signal(s) Limit Residual ripple Time constant Response time 1 acc. to IEC 770 DC voltage signal U A Voltage drop U V Approx. 0 ma < 20 mv ss Approx. ms Approx. 15 ms 0 10 V < 2.8 V with standard (non-ex) version <.7 V with (input signal(s) < 6. V with (output signal(s) Internal resistance Limit 500 Ω Accuracy data Error limits < ± 0.1% (Reference value 20 ma of output signal, typical linearity error included) < ± 0.2% (Reference value 10 V of output signal, typical linearity error included) Reference conditions DC current signal I E Ambient temperature Output burden Additional error Burden influence Temperature coefficient Installation data 0 20 ma 2 C ± 1 K 250 Ω (at DC current output signal) 5 MΩ (at DC voltage output signal) < 0.05% / 100 Ω (at DC current output signal) < 50 ppm/k Mechanical design Housing N17 or housing S17 Dimensions see section Dimensional drawings Material of housing Lexan 90 (polycarbonate). Flammability Class V-0 acc. to UL 9, self-extinguishing, non-dripping, free of halogen Mounting Snapping onto top-hat rail 5 7.5 or 5 15 mm (acc. to EN 50 022) or directly onto a wall with 2 screws and adapter (for TI 807-5...) pull-out screw hole brackets (for TI 807-1...) Mounting position Any Electrical connections Screw terminals with wire guards for light PVC wiring and max. 2 0.75 mm 2 or 1 2.5 mm 2 < 26 V with standard (non-ex) version < 16 V with (input signal(s) < 16 V with (output signal(s) Residual ripple Time constant Response time 1 acc. to IEC 770 < 20 mv ss Approx. ms Approx. 15 ms 1 This is the time which transpires before the output signal reaches the error limit of 1% for a step change of the input signal from 0 90%. 2 Data sheet TI 807-5/-1 Le 01.0 Camille Bauer

Weight approx. 100 g TI 807-5... (housing N17) approx. 180 g TI 807-1... (housing S17) with 2 isolation and transmission channels approx. 200 g TI 807-1... (housing S17) with isolation and transmission channels Regulations Test voltage kv, 50 Hz, 1 min..0 kv 2. kv 2. kv TI 807-5... (housing N17) standard (non-ex) version TI 807-5... (housing N17) (input or output signal TI 807-1... (housing S17) non-ex and (input or output signals Surge voltage kv, 1.2/50 µs 5.0 kv.25 kv.25 kv TI 807-5... (housing N17) Standard (non-ex) version TI 807-5... (housing N17) (input or output signal TI 807-1... (housing S17) non-ex and Ex-versions (input or output signals Input versus output Inputs versus Inputs versus inputs Outputs versus Input versus output Inputs versus Inputs versus Outputs versus Electromagnetic compatibility The standards DIN EN 50 081-2 and DIN EN 50 082-2 are observed Intrinsically safe Acc. to DIN EN 50 020 1996-0 Electrical design Acc. to IEC 1010 resp. EN 61 010 Contamination level 2 Overvoltage category Protection (acc. to IEC 529 resp. EN 60529) Housing IP 0 Terminals IP 20 Ambient conditions II Operating temperature 25 to 55 C 20 to 55 C (for the input or output signal(s) Storage temperature 0 to 70 C Annual mean relative humidity Seismic test 75% standard climatic rating 95% improved climatic rating 5 g, < 200 Hz, 2 h in each of directions Shock 50 g, 10 shocks in each of directions Standard version in housing N17 for rail or wall mounting The following signal isolator versions are available as standard versions. It is only necessary to quote the Order No. Table 1 Instruments in standard (non-ex) version (input and output signal non intrinsically safe) Description Climatic Output signal Order Code Order No. rating, Standard (non-ex) version, input signal 0 20 ma, with 1 isolation and transmission channel standard 0 20 ma 807 51100 999 15 Camille Bauer Data sheet TI 807-5/-1 Le 01.0

Table 2 Instruments in [EEx ib] IIC version (input signal intrinsically safe) Description Climatic Output signal Order Code Order No. rating, [EEx ib] IIC, input signal intrinsically safe 0 20 ma, output signal non intrinsically safe, with 1 isolation and transmission channel standard 0 20 ma 807 52100 999 196 Table Instruments in [EEx ia] IIC version (output signal intrinsically safe) Description Climatic Output signal Order Code Order No. rating, [EEx ia] IIC, input signal non intrinsically safe 0 20 ma, output signal intrinsically safe, with 1 isolation and transmission channel standard 0 20 ma 807 56100 999 170 Standard versions in housing S17 for rail and wall mounting The following signal isolator versions are available as standard versions. It is only necessary to quote the Order No Table Instruments in standard (non-ex) version (input and output signal non intrinsically safe) Description Number of Output signal Order Code Order No., standard (non-ex) version, channels 2 channels 0 20 ma 807 11200 995 061 input signal 0 20 ma, standard climatic rating channels 0 20 ma 807 1100 996 96 The complete Order Code 807-... and/or a description should be stated for other versions (see Table 5 Specification and ordering information ). Table 5 Specification and ordering information (see also Tables 1 to Standard versions ) Order Code 807 Features, Selection *SCODE no-go 1. Mechanical design 1) Housing S17 B 1....... 5) Housing N17 C 5....... 2. Version 1) Standard (non-ex), input and output signal(s) non intrinsically safe. 1...... 2) [EEx ib] IIC, input signal(s) intrinsically safe. 2...... 6) [EEx ia] IIC, output signal(s) intrinsically safe. 6...... Data sheet TI 807-5/-1 Le 01.0 Camille Bauer

Order Code 807 Features, Selection *SCODE no-go. Number of isolation and transmission channels 1) 1 channel (interface) B 1....... 2) 2 channels (interfaces) C 2....... ) channels (interfaces) C....... Line 1 1 channel only available for signal isolators in the housing type N17. Lines 2 and 1 and channels only available for signal isolators in the housing type S17.. Output signal(s) A or A1 and A2 or A1, A2 and A 0) 0 20 ma. 0...... 1) 0 10 V, 1 channel B. 1...... 2) 0 10 V, 2 channels C. 2...... ) 0 10 V, channels C....... 5. Climatic rating 0) Standard climatic rating.. 0..... 1) Improved climatic rating.. 1..... * Lines with letter(s) under no-go cannot be combined with preceding lines having the same letter under SCODE. Table 6 Data on explosion protection II (2) G resp. II (1) G Order Type of Electrical data acc. to Certificates Type Examination Certificate Mounting Code protection Input Output location 807-52... [EEx ib] IIC 807-56... [EEx ia] IIC L i = 2 µh C i = 0 for connection to certified intrinsically safe circuit with the following maximum values U i = V = 150 ma I i U m = 25 V AC resp. 125 V DC U m = 25 V AC resp. 125 V DC U o I o P o = 15.75 V = 100 ma = 00 mw linear characteristic IIC IIB PTB 97 ATEX 2112 Outside the hazardous area L o mh 15 mh C o 78 nf 2.88 µf Continuation of Table 6 see on next page! Camille Bauer Data sheet TI 807-5/-1 Le 01.0 5

Table 6 Data on explosion protection (Continuation) Order Type of Electrical data acc. to Certificates Type Examination Certificate Mounting Code protection Input Output location 807-12... [EEx ib] IIC 807-16... [EEx ia] IIC L i = 2 µh C i = 0 for connection to certified intrinsically safe circuit with the following maximum values U i = V = 150 ma I i U m = 25 V AC resp. 125 V DC U m = 25 V AC resp. 125 V DC U o I o P o = 15.75 V = 100 ma = 00 mw linear characteristic IIC IIB PTB 97 ATEX 2102 Outside the hazardous area L o mh 15 mh C o 78 nf 2.88 µf Electrical connections Signal isolator in housing N17 with one isolation and transmission channel A E 1 2 E Fig.. SINEAX TI 807-511.., standard (non-ex) version and SINEAX TI 807-561.., (output signal A 1 2 A Fig. 5. SINEAX TI 807-521.., Ex version (input signal E Signal isolator in housing S17 with two isolation and transmission channels 1 6 2 7 A1 A2 1 6 2 7 E1 E2 8 9 E1 E2 Fig. 6. SINEAX TI 807-112.., standard (non-ex) version and SINEAX TI 807-162.., (output signals A1 and A2 8 9 A1 A2 Fig. 7. SINEAX TI 807-122.., Ex version (input signals E1 and E2 6 Data sheet TI 807-5/-1 Le 01.0 Camille Bauer

Signal isolator in housing S17 with three isolation and transmission channels 1 6 11 2 7 12 A1 A2 A 1 6 11 2 7 12 E1 E2 E 8 1 9 1 E1 E2 E Fig. 8. SINEAX TI 807-11.., standard (non-ex) version and SINEAX TI 807-16.., Ex version (output signals A1, A2 and A 8 1 9 1 A1 A2 A Fig. 9. SINEAX TI 807-12.., Ex version (input signals E1, E2 and E Dimensional drawings Adapter Adapter 8.5 8.5 60 17.5 0.5 0 107.1 17.5 0.5 0 112.1 5.8 Fig. 10. SINEAX TI 807-5... (housing N17) clipped onto a top-hat rail (5 7.5 or 5 15 mm, acc. to EN 50 022). Fig. 11. SINEAX TI 807-5... (housing N17) with adapter for directly wall mounting. 1 6.5 120 Ø.5 120 1 120 17.5 0.5 0 16.5 17.5 0.5 0 12 15.5 Fig. 12. SINEAX TI 807-1... (housing S17) clipped onto a top-hat rail (5 7.5 or 5 15 mm, acc. to EN 50 022). Fig. 1. SINEAX TI 807-1... (housing S17) screw hole mounting brackets pulled out. Camille Bauer Data sheet TI 807-5/-1 Le 01.0 7

Standard accessories 1 Adapter (for signal isolators TI 807-5..., variants in housing type N17 only) 1 Operating Instructions each in German, French and English for SINEAX TI 807-5 in housing type N17 1 Operating Instructions in three languages German, French and English for SINEAX TI 807-1 in housing type S17 1 Type Examination Certificate (for instruments in type of protection Intrinsically safe only) Subject to change without notice Edition 01.0 Data sheet No. TI 807-5/-1 Le Camille Bauer LTD Aargauerstrasse 7 CH-5610 Wohlen/Switzerland Phone 1 56 618 21 11 Fax 1 56 618 2 58 e-mail info@camillebauer.com http//www.camillebauer.com 8 Data sheet TI 807-5/-1 Le 01.0 Camille Bauer