LOW BETA CAVITY DEVELOPMENT FOR AN ATLAS INTENSITY UPGRADE

Similar documents
SRF Advances for ATLAS and Other β<1 Applications

Superconducting RF Cavities Development at Argonne National Laboratory

Advances in CW Ion Linacs

ADVANCES IN CW ION LINACS*

DESIGN AND BEAM DYNAMICS STUDIES OF A MULTI-ION LINAC INJECTOR FOR THE JLEIC ION COMPLEX

Frequency Tuning and RF Systems for the ATLAS Energy Upgrade. Gary P. Zinkann

DEVELOPMENT OF A BETA 0.12, 88 MHZ, QUARTER WAVE RESONATOR AND ITS CRYOMODULE FOR THE SPIRAL2 PROJECT

QUARTER WAVE COAXIAL LINE CAVITY FOR NEW DELHI LINAC BOOSTER*

KEYWORDS: ATLAS heavy ion linac, cryomodule, superconducting rf cavity.

Structures for RIA and FNAL Proton Driver

5.5 SNS Superconducting Linac

RF STATUS OF SUPERCONDUCTING MODULE DEVELOPMENT SUITABLE FOR CW OPERATION: ELBE CRYOSTATS

SUPERCONDUCTING PROTOTYPE CAVITIES FOR THE SPALLATION NEUTRON SOURCE (SNS) PROJECT *

DESIGN STUDY OF A 176 MHZ SRF HALF WAVE RESONATOR FOR THE SPIRAL-2 PROJECT

Physics Requirements Document Document Title: SCRF 1.3 GHz Cryomodule Document Number: LCLSII-4.1-PR-0146-R0 Page 1 of 7

Project X Cavity RF and mechanical design. T. Khabiboulline, FNAL/TD/SRF

Progresses on China ADS Superconducting Cavities

HIGH POWER COUPLER FOR THE TESLA TEST FACILITY

THE MULTIPACTING STUDY OF NIOBIUM SPUTTERED HIGH-BETA QUARTER-WAVE RESONATORS FOR HIE-ISOLDE

A New 2 K Superconducting Half-Wave Cavity Cryomodule for PIP-II

CONICAL HALF-WAVE RESONATOR INVESTIGATIONS

COMPARISON OF BUFFERED CHEMICAL POLISHED AND ELECTROPOLISHED 3.9 GHz CAVITIES*

S. Ghosh On behalf of Linac, IFR, Cryogenics, RF and beam transport group members. Inter University Accelerator Centre New Delhi India

Accelerator R&D for CW Ion Linacs

HIGH POWER INPUT COUPLERS FOR THE STF BASELINE CAVITY SYSTEM AT KEK

CHALLENGES IN ILC SCRF TECHNOLOGY *

HIGH POWER PULSED TESTS OF A BETA=0.5 5-CELL 704 MHZ SUPERCONDUCTING CAVITY

ACHIEVEMENT OF ULTRA-HIGH QUALITY FACTOR IN PROTOTYPE CRYOMODULE FOR LCLS-II

CAGE CAVITY: A LOW COST, HIGH PERFORMANCE SRF ACCELERATING STRUCTURE*

Processing and Testing of PKU 3-1/2 Cell Cavity at JLab

HIGH Q CAVITIES FOR THE CORNELL ERL MAIN LINAC

Advance on High Power Couplers for SC Accelerators

MULTIPACTING IN THE CRAB CAVITY

Amit Roy Director, IUAC

SUPERCONDUCTING RESONATORS DEVELOPMENT FOR THE FRIB AND ReA LINACS AT MSU: RECENT ACHIEVEMENTS AND FUTURE GOALS

Current Industrial SRF Capabilities and Future Plans

Recent Results of High Gradient Superconducting Cavities at Cornell

Report of working group 5

Cavity development for TESLA

Liquid Helium Heat Load Within the Cornell Mark II Cryostat

To produce more powerful and high-efficiency particle accelerator, efforts have

Status of the superconducting cavity development at RISP. Gunn Tae Park Accelerator division, RISP May 9th. 2014

THE U. S. RIA PROJECT SRF LINAC*

High acceleration gradient. Critical applications: Linear colliders e.g. ILC X-ray FELs e.g. DESY XFEL

The Superconducting Radio Frequency Quadrupole Structures Review

DEVELOPMENT OF QUARTER WAVE RESONATORS

DEVELOPMENT, PRODUCTION AND TESTS OF PROTOTYPE SUPERCONDUCTING CAVITIES FOR THE HIGH BETA SECTION OF THE ISAC-II HEAVY ION ACCELERATOR AT TRIUMF

A 3 GHz SRF reduced-β Cavity for the S-DALINAC

PROGRESS IN IFMIF HALF WAVE RESONATORS MANUFACTURING AND TEST PREPARATION

Packaging of Cryogenic Components

RF power tests of LEP2 main couplers on a single cell superconducting cavity

Overview of ERL Projects: SRF Issues and Challenges. Matthias Liepe Cornell University

Design of the 352MHz, beta 0.50, Double- Spoke Cavity for ESS

Superconducting RF cavities activities for the MAX project

COUPLER DESIGN CONSIDERATIONS FOR THE ILC CRAB CAVITY

ALICE SRF SYSTEM COMMISSIONING EXPERIENCE A. Wheelhouse ASTeC, STFC Daresbury Laboratory

Completion of the first SSR1 cavity for PXIE

THE CRYOGENIC SYSTEM OF TESLA

The European Spallation Source. Dave McGinnis Chief Engineer ESS\Accelerator Division IVEC 2013

Review of New Shapes for Higher Gradients

SRF EXPERIENCE WITH THE CORNELL HIGH-CURRENT ERL INJECTOR PROTOTYPE

CEBAF Overview June 4, 2010

TESLA RF POWER COUPLERS DEVELOPMENT AT DESY.

REVIEW ON SUPERCONDUCTING RF GUNS

REVIEW OF HIGH POWER CW COUPLERS FOR SC CAVITIES. S. Belomestnykh

Nb 3 Sn Present Status and Potential as an Alternative SRF Material. S. Posen and M. Liepe, Cornell University

Status and Plans for the 805 MHz Box Cavity MuCool RF Workshop III 07/07/09 Al Moretti

REVIEW OF NEW SHAPES FOR HIGHER GRADIENTS

Dong-O Jeon Representing RAON Institute for Basic Science

Recent Progress in the Superconducting RF Program at TRIUMF/ISAC

Coupler Electromagnetic Design

CEBAF waveguide absorbers. R. Rimmer for JLab SRF Institute

Design Topics for Superconducting RF Cavities and Ancillaries

CENTRIFUGAL BARREL POLISHING OF CAVITIES WORLDWIDE

A few results [2,3] obtained with the individual cavities inside their horizontal cryostats are summarized in Table I and a typical Q o

UPDATE ON THE R&D OF VERTICAL BUFFERED ELECTROPOLISHING ON NIOBIUM SAMPLES AND SRF SINGLE CELL CAVITIES*

SNS CRYOMODULE PERFORMANCE*

C100 Cryomodule. Seven cell Cavity, 0.7 m long (high Q L ) 8 Cavities per Cryomodule Fits the existing Cryomodule footprint

KEK ERL CRYOMODULE DEVELOPMENT

QWR Nb sputtering. Anna Maria Porcellato. MoP04. S. Stark, F. Stivanello, V. Palmieri INFN Laboratori Nazionali di Legnaro

High Power Couplers for TTF - FEL

A Study of Magnetic Shielding Performance of a Fermilab International Linear Collider Superconducting RF Cavity Cryomodule

Development of Superconducting CH-Cavities for the EUROTRANS and IFMIF Project 1

The TESLA Linear Collider. Winfried Decking (DESY) for the TESLA Collaboration

3.9 GHz work at Fermilab

DESIGN OF SINGLE SPOKE RESONATORS FOR PROJECT X*

First Cavity Results from the Cornell SRF Group's Nb 3 Sn Program

R.Bachimanchi, IPAC, May 2015, Richmond, VA

THE HIGH LUMINOSITY PERFORMANCE OF CESR WITH THE NEW GENERATION SUPERCONDUCTING CAVITY

JIJL NIOBIUM QUARTER-WAVE CAVITY FOR THE NEW DEEM BOOSTER LINAC

LORENTZ FORCE DETUNING ANALYSIS OF THE SPALLATION NEUTRON SOURCE (SNS) ACCELERATING CAVITIES *

OVERVIEW OF INPUT POWER COUPLER DEVELOPMENTS, PULSED AND CW*

PIP-II Superconducting RF Linac Status and Challenges" Leonardo Ristori! ICEC-ICMC Conference, New Delhi! 9 March 2016!!

3.9 GHz Deflecting Mode Cavity

Superconducting RF Cavity Performance Degradation after Quenching in Static Magnetic Field

DEVELOPMENTS OF HORIZONTAL HIGH PRESSURE RINSING FOR SUPERKEKB SRF CAVITIES

Design of ESS-Bilbao RFQ Linear Accelerator

RECORD QUALITY FACTOR PERFORMANCE OF THE PROTOTYPE CORNELL ERL MAIN LINAC CAVITY IN THE HORIZONTAL TEST CRYOMODULE

Performance of Superconducting Cavities for the European XFEL. Detlef Reschke DESY for the EU-XFEL Accelerator Consortium

R.L. Geng, C. Crawford, H. Padamsee, A. Seaman LEPP, Cornell University, Ithaca, NY14853, USA

Transcription:

LOW BETA CAVITY DEVELOPMENT FOR AN ATLAS INTENSITY UPGRADE M. P. Kelly, Z. A. Conway, S. M. Gerbick, M. Kedzie, T. C. Reid, R. C. Murphy, B. Mustapha, S.H. Kim, P. N. Ostroumov, Argonne National Laboratory, Argonne, IL 60439, U.S.A. Abstract Seven new 72 MHz superconducting quarter-wave (QWR) cavities have been completed and are being installed in the ATLAS heavy-ion accelerator at Argonne. The aim is to provide at least 17.5 MV accelerating potential with large acceptance and minimal beam losses for high intensity ion beams. Cavities are being installed into ATLAS in 2013 as part of a larger beam intensity upgrade. The cavity electromagnetic design uses optimizations not used before with quarter-wave cavities, including a taper on both the inner and outer conductors in order to reduce surface fields, while at the same time, spanning no more space along the beam line axis. Electropolishing (EP) on all cavities with integral helium jacket and no demountable rf joints is unique for low beta cavities. The new EP system is an extension of the Argonne system for ILC work. Single cavity cold tests show quench fields between 98-165 mt. Cavity residual resistances at the proposed operating point of ~70 mt are 2-3 n Significant technical details including the use of wire EDM and relatively low heat keyhole welds for niobium fabrication are presented. INTRODUCTION The ATLAS Efficiency and Intensity Upgrade [1] includes a fully operational CW radio frequency quadrupole injector and a new cryomodule of 7 SC cavities for =0.077. The cryomodule is replacing three cryomodules of split-ring resonators in the middle portion of the ATLAS SC ion linac. In fact, the three split-ring cryomodules are the first section of superconducting linac used for ion acceleration and the second superconducting linac anywhere. This follows work on the 2009 ATLAS Energy Upgrade cryomodule. The 2009 cryomodule has been available for full time operations, providing V ACC =14.5 MV over 4.6 meters, the highest gradient for any SC linac for this range of beta. The new 5-meter cryomodule will provide at least 20% more voltage, 17.5 MV, even though cavities have half the beta, G =0.077. A number of technical improvements are implemented compared to the previous designs in order to achieve this performance. The improved rf design [2] and the unique capability to electropolish complete quarter-wave cavities [3], the near elimination of resonant micophonics and the relatively uncommon use of wire electron discharge machining (EDM) and lower heat keyhole welds are described here. CAVITY PERFORMANCE Cold tests at 2 K and 4 K for five out of eight new 72 MHz cavities have been performed in the large Argonne single cavity test cryostat. Seven of these cavities, shown in Figures 1 and 2, have been installed into the new ATLAS cryomodule as part of the intensity upgrade. The eighth was intended for R&D to advance the performance for this class of cavity [4]. Three cavities were not tested individually, but instead installed directly into the cryomodule. During a two week commissioning test, all cavities, including the three previously untested cavities, reached at least E ACC =10 MV/m with minimal rf conditioning, and exceeding the nominal design goal of E ACC =8 MV/m (l EFF = m Curves for quality factor versus accelerating gradient curves will be measured during the next cold test. For commissioning purposes, accelerating gradients were extracted from the previously measured CW Lorentz force detuning coefficient of 1.7±0.2 Hz/(MV/m) 2 and checked for two cases using x-ray end point energies, the product of bremsstrahlung from field emitted electrons. Figure 1: Final clean string assembly just before removal from the clean room. 850 Figure 2: Cavity cold mass suspended from the cryomodule lid.

THIOC01 Table 1: Calculated 72 MHz Cavity EM Parameters Figure 3: Surface fields (absolute value on a linear scale) for the ANL quarter-wave with the conical outer housing. DESIGN AND FABRICATION Electromagnetic Design The 72.75 MHz cavity electromagnetic (EM) design incorporates two features which are unique to date. One directly improves cavity RF field performance and the second permits loss free transport of high current ( 100 e A) ion beams. The modifications in the shape of the cavity, primarily in the high magnetic field region and analogous to the adaptation of the standard TESLA 1.3 GHz cell shape to the high gradient shape, are discussed first. The conical shaped inner and outer conductors, shown in Figure 3, have not yet been used on any coaxial TEM cavity. The peak electric and peak magnetic surface fields are calculated in CST MWS. Color coding is on a linear scale. In general terms, the larger volume in the magnetic field region, due to conical shape, results in a lower surface current over the entire center conductor. The reduction of B PEAK is 25% as compared to a cavity at the same frequency and beta that is constructed only from right cylinders. The other EM parameters, including the R/Q and geometry factor are also improved as indicated in Table 1. The increase in the R/Q is expected due to the reduction in the average magnetic field (squared) over most of the central conductor for a given value of accelerating field. The geometry factor, proportional to the stored energy divided by an integral of surface magnetic field squared, also tends to increase as the shape becomes more spherical. Finally, even though the shape in the beam aperture region is unchanged, the normalized E PEAK is reduced by 10% due to the more efficient geometry. The improvement in EM parameters is achieved at the cost of an increase in fabrication complexity. Specifically, rather than rolled and seam welded niobium cylinders for Parameter Right Conical Cylinder Shapes Units * E PEAK 5.9 5.1 MV/m * B PEAK 10.2 7.6 mt/(mv/m) Geometry Factor 16.8 26.4 R SH /Q 515 575 *normalized to E ACC =1 MV/m, l eff = the outer housing, the outer conductors were formed from three 120 o sections of a cone. However, this was judged to be a reasonable trade off due to the B PEAK reduction and the observation that performance for ANL cavities has been limited by magnetic field (quench or Q-slope). The improved EM parameters could, in principle, provide an additional accelerating voltage equivalent of two additional cavities for a seven cavity cryomodule. An EM design technique, introduced more than a decade ago, but used in practice only once previously, is the correction of the intrinsic steering in the quarter-wave cavity by means of an electric field intentionally introduced in the direction transverse to the beam axis. The unwanted steering is caused by a non-zero magnetic field on the beam axis due to the top-to-bottom asymmetry in the quarter-wave geometry and the correcting electric field comes from an intentional tilt built into the surfaces of the beam aperture region. For this case (f 0 =72.75 MHz and G =0.077), the tilted angle of the cavity faces is 2.2 o.and the resultant reduction in the beam steering angle is a factor of 10 or more over the full useful velocity range (0.07< <0.2). The absolute value of the steering angle is less than 0.1 mrad with the correction. It is noted that this method of correction has a weaker beta dependence than a correction performed by vertically offsetting the cavity. In the former there is also no sacrifice of beam aperture. Finally, here there is no additional fabrication cost since the angle is built into the NC machined dies used for niobium forming Fabrication Details Assembly of the cavity parts from RRR 250 niobium sheet metal formed is performed by electron beam welding in a high vacuum chamber. The geometry requires roughly seven linear meters of electron beam welding, with almost one third of the distance in regions where the magnetic field, B 0.8 B PEAK. For the present set of quarter-waves, all welds in the high magnetic field regions are of a so called keyhole type, where the beam necessarily strikes the niobium from the direction of the rf surface. This type of welding is qualitatively different from the standard through weld, but is little known in the SRF cavity community since most elliptical cell geometries can only be assembled using through welds in the high B-field region. In this case the electron beam impinges the surface from the liquid helium side. However, for TEM structures there is direct 851

Figure 4: Two weld types used to assemble quarter-wave cavities. line-of-sight to the high B-field portion of the rf surface until the later stages of assembly, so that the keyhole technique is possible. Examples of the visual appearance for a good quality standard through weld and a keyhole weld are shown in Figure 4. Differences in the main beam parameters include a higher travel speed, a tighter focus and a four times lower total deposited power for the keyhole approach. The weld bead structures are very different. Whereas the 3 mm though weld (Figure 3 left) produces a large grained, 1 cm wide bead through the bulk, and large grain steps on the rf surface, the keyhole weld (right) produces a smooth narrow bead with small grain steps. The smoothness is produced during a final low (~40% of full) power welding step referred to as the cosmetic pass. This final step is not possible for through welds. These cavities don t provide a chance to isolate the impact of this technique alone on rf performance; however, they do provide proof of principle that the keyhole technique is compatible with high (~165 mt) surface fields. It is noted that wire electric discharge machining (EDM) was used to perform essentially all cutting on niobium subcomponents. The technique should, in principle, give similar results as for traditional mill machining, however, in practice it requires much less fixturing and technical skill with niobium and reduces the likelihood for embedding inclusions. Hydrogen contamination from EDM is not a major drawback since cavities require degassing anyway to achieve optimal performance at either 2 K or 4 K. Electropolishing The ANL low-beta cavity electropolishing system provides a unique and practical capability to perform electropolishing on the complete niobium cavity with helium jacket. This is possible because TEM-mode cavities do not require field flatness tuning or access to the niobium surface after polishing. The system and associated polishing parameters are similar to those for horizontal systems used with 1.3 GHz cavities for the global international linear collider effort. There is one major improvement, however. For co-axial TEM cavities, the helium jacket has been used to directly cool the niobium surface with chilled (22+/-0.5 o C) water and the niobium temperature has been measured to be stable and uniform to within 5 o C over the cavity surface. As with elliptical cells, the cavities are rotated during the 852 Figure 5: Q versus E ACC, V ACC, B PEAK and E PEAK for 5 of quarter-wave cavities. procedure at a speed of 1 rpm, however unlike with most e-cells, the maximum temperature on the niobium surface never rises above 32 o C at any time during the rotation period. The total removal for all cavities was close to 150 m. Two separate rounds of polishing were performed. First, after fabrication, the cavities were electropolished on consecutive days, removing 65 m of niobium each day. Total polishing time was about 12 hours. The cavities were then baked under vacuum at Fermilab for 14 hours at 625 o C in order to degas hydrogen. Last, the cavities were returned to Argonne for a final light 20 m electropolish. Possible contamination from the Fermilab furnace, a known issue for some bare niobium elliptical cavities, appears to have had no negative impact here, possibly because of the relatively small 50 mm cavity access ports which make an effective baffle to the rf surface. PERFORMANCE Four out of seven new 72 MHz cavities and one R&D cavity were tested at both 2.0 and 4.5 Kelvin and results are shown in Figure 5. In ATLAS, cavities will be operated at 4.5 K with a nominal accelerating gradient of 7.9 MV/m (l eff = 31.75 cm) or 2.5 MV/cavity. The assumed quality factor was Q=1x10 9 with a corresponding surface resistance of 26 n. In practice, as much as 15-20 Watts of cryogenic cooling per cavity should be available, allowing cavities to operate at or above E ACC ~10 MV/m. The five tested cavities achieved CW accelerating gradients at 4.5 K ranging between E ACC =12.4-16.2 MV/m, or up to double the originally planned values. Most cavities had approximately 3 hours of low-level (E ACC =0-1.5 MV/m) multipacting conditioning and one half to 1 hour of short pulse conditioning with 4 kw peak

THIOC01 Figure 6: Averaged surface resistance extracted from the cavity geometry factor and the measured Q o at 2 K. (R BCS ~0). power in order to achieve the measured performance shown in Figure 2. High-field multipacting (E ACC >2 MV/m), observed briefly in most cavities, was easily conditioned in minutes by adjusting the coupler for the matched condition and transmitting a few 10 s of Watts into the multipactor barrier. Only the prototype cavity received an in-situ 120 o C bake. For this case, cold testing before and after showed no measureable difference from baking. This is not considered to be a definitive test of the technique since unwanted temperature variations of ±10 o C both in time and over the cavity surface were observed. 2 Kelvin Performance ANL is also pursuing R&D needed in to demonstrate practical 2 K operation, the likely operating mode for future large SRF linacs. The high practical cavity field gradients possible at 2 K, combined with the compact lattice of the Argonne cryomodule design, can provide real-estate gradients of 7 MV/m (at B PEAK =120 mt), or about 2-3 times higher than for today s state-of-the-art at 4 K. This would make feasible the construction of a compact ion linac that might be attractive for the next generation of high-power accelerators. The five cavities tested individually already move close to this goal, reaching magnetic surface fields in the range B PEAK =98-165 mt. In two of five cases, the thermalmagnetic breakdown was extracted from pulsed, 5% duty cycle, measurements in order to limit x-ray production at very high fields. These points are not included on Figure 6. The lowest quench at 98 mt for the first prototype is due to breakdown on the central conductor as determined from second sound measurements. The location corresponds to that of a known welding defect, where contamination on the center conductor weld preparation is known to have occurred. At the other extreme of performance, the R&D quarterwave cavity was never driven to quench (maximum B PEAK =165 mt), but was finally administratively limited due to copious x-ray emission at E PEAK =115 MV/m, producing x-rays for which the existing shielding was never designed. In addition to the high quench field, the R&D cavity also has a slightly higher surface resistance than for the other four cavities. It is unknown whether this is related to the longer 625 o C hydrogen degassing time, the different niobium supplier, or some other effect. Four of the cavities have a 2 K residual resistance, ranging from 1-2 n at low fields, a value that has been very difficult to achieve in higher frequency elliptical cell cavities. The curves in Figure 5 show a measure of residual resistivity as a function of magnetic field. We note that with the 7 cm variable coupler used for these tests, Qo comes directly from low field weekly coupled decay time measurements. Errors on both Qo and R RES are, therefore, much smaller than is common with fixed couplers. The estimated Qo error is ±2.5% coming mostly from extraction of the weakly coupled energy decay time from the voltage decay curve as measured on a digital oscilloscope. MICROPHONICS Design features and fabrication techniques for new quarter-wave cavities nearly eliminate microphonics. These include; (1) reduction of pressure sensitivity by mechanical and EM design, mechanical centering of the central conductor during fabrication, and (3) a passive mechanical damper to reduce the intrinsic mechanical Q of cavity vibrations. Centering is done by inserting a long stainless bar into the center conductor through a 50 mm port in the top of the helium jacket and then inelastically bending the center conductor while monitoring the frequency on a network analyzer. The total bending was approximately 1 mm with a final accuracy of about +/- 100 microns, however, we note it is unnecessary to make dimensional measurements in order to perform the centering. Only frequency is required. The benefit is large, with a reduction in the peak-to-peak amplitude for resonant pendulum mode microphonics by an order of magnitude, even before mechanical damper installation. Peak-to-peak microphonics amplitude for all cavities installed inside the cryomodule was measured to by ±2 Hz over periods of minutes to days during the commissioning cool down, or only about 5% the maximum planned fast tuning window. CONCLUSION The fabrication and assembly of a seven cavity ATLAS cryomodule of quarter-wave cavities and one R&D cavity for =0.077 and f 0 =72.75 MHz is complete. Horizontal electropolishing on the completed cavities was performed for the first time. Initial results at both 2 K and 4 K show performance ranging from B PEAK =98-165 mt, E PEAK =70-120 MV/m, and practical acceleration at V ACC >3 MV/cavity at 4.5 K and V ACC >5 MV/cavity at 2 K. In the commissioning cool down of the cryomodule all cavities where operated with E ACC 10 MV/m. Levels for fast 853

microphonics were measured to be ±2 Hz peak-to-peak demonstrating the effectiveness of EM and mechanical techniques presented here. ACKNOWLEGDEMENT This work was supported by the U.S. Department of Energy, Office of Nuclear Physics, under Contract No. DE-AC02-06CH11357. REFERENCES [1] P.N. Ostroumov, et al., Proc. of LINAC 2012, TUPLB08 [2] B. Mustapha, et al., Proc. of LINAC-2010, Tsukuba, Japan, September 12-17, 2010. [3] S.M. Gerbick et al., A New Electropolishing System for Low Beta Cavities, Proc. of SRF 2011. 854