S L n u. M e. E n te r. Transmitter: Flow range: 0 ~ ±40ft/s (0 ~ ±12m/s) Accuracy: ±1.0% Repeatability: 0.3% Outputs: OCT, KHz

Similar documents
ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

ULTRASONIC FLOW METER FT101

Applications Features

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

DigitalFlow TM CTF878

Model Sono-Trak Transit Time

RISONIC Ultrasonic Transit Time Flow Measurement For Filled/Partially Filled Pipes For Open Channels. Supply Disposal Hydraulic Power Station

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

Technical Specification FLUXUS ADM 8127B

Technical specification FLUXUS F401 H2O

DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Measurement & Control. Applications. Features

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

SLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter

OPTISONIC 6300 P Technical Datasheet

Ultrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK.

UTM10 Series Ultrasonic Transit-time Flowmeters

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

Advanced instrumentation solutions crafted with highest precision

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Advancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

DigitalFlow DF868. Panametrics Liquid Ultrasonic Flowmeter. GE Measurement & Control. Applications. Features

Electro-Magnetic Flowmeters COPA-XE

KATflow 230 Portable Clamp-On Ultrasonic Flowmeter

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.

E l e c t r o m a g n e t i c f l o w m e t e r s

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

Flow Measurement SITRANS F M

Digital batch controller

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

Ultrasonic level transmitter, non-contact

Electromagnetic Flow Transmitter

Digital flowmeter for continuous flow measurement

MagFlux ELECTROMAGNETIC FLOWMETERS BROCHURE EN 3.05 MAGFLUX BROCHURE 1401

Digital flowmeter for continuous flow measurement

Flow Measurement SITRANS F US Clamp-on

Ultrasonic Level Transducer Type: MPUL06 Article No.: ca. 122

Sarasota CM200 Sarasota HME900 Density Converter Electronics

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

DigitalFlow DF868 Panametrics Liquid Ultrasonic Flowmeter. GE Sensing. Applications. Features

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

Advanced Test Equipment Rentals ATEC (2832) Clamp-on Ultrasonic Flow Meter Family

Technical Specification FLUXUS F601

Model R7900. Instruction Manual. Ultrasonic Thickness Gauge. reedinstruments. www. com

Design and applications

Technical Specifications

LST400 Ultrasonic level / open channel flow transmitter

MPU 200 Series B. Ultrasonic Gas Flowmeter. Specifications. Features. Principle of Operation

Technical Specification FLUXUS F608**-F2

Digital conductivity transmitter

AF91 Adjustable Frequency Drives Series B

Ambient Conditions. Operating Conditions. Pressure

OPTISONIC 7300 Technical Datasheet

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

Technical Specification FLUXUS F601

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

SITRANS F US Clamp-on

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

Technical Specification FLUXUS ADM 8x27

Wall Mounted Ultrasonic Flowmeter USER GUIDE

IFC 010 Signal Converter

Advancements in Clamp-on Ultrasonic Flow Measurements. Ohio Section AWWA SE District Fall Meeting September 1 st 2017

Ultrasonic Flowmeter Instruction Manual. Model: LRF-3000H. LRF-3000H Handheld Ultrasonic Flowmeter. Revision 1.1. Update Record. Date Nov.

The transducer component converts the measured signal and displays the actual value.

LST100 Ultrasonic level transmitter for upstream oil and gas

Flow Measurement SITRANS F US Inline

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter

Digital inductive conductivity transmitter

Clamp-on Fixed Type Ultrasonic Flowmeter

2-wire level transmitter

Instruction Manual Ultrasonic Level Meter Model: NUS

Specification DataFile

PanaFlow HT. Panametrics Ultrasonic SIL Flow Meter for Liquids. GE Measurement & Control. Applications. Features & Benefits

FLOWMETER. Siemens MAG 5000/6000. Overview

FH CMF Coriolis Mass Flow Meters

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

ANALYTICAL - COMPLEXITY MADE SIMPLE

CMS 603DC PI. Technical Data Sheet

Flow Measurement SITRANS F US Inline

DUC. Ultrasonic Flowmeter for Liquids. Portable or Stationary

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

SUBSURFACE INSTRUMENTS, INC. AML PRO & AML+ PRODUCT GUIDE

Rosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev TA April 2009.

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

ADJUSTABLE SPEED DRIVES FS1

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

TEK-CLAMP 1200A Ultrasonic Clamp-On Flowmeter

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Digital flow transmitter for continuous flow measurement

MG2 Series. Corrosion Thickness Gages. MG2, MG2-XT, and MG2-DL. MG2-xt and MG2-DL are. B-scan and optional Live A-scan with Waveform Adjust

WATERFLUX 3070 Technical Datasheet

ADDMAS CORIOLIS MASS FLOW METER

Hand Held Ultrasonic Flow Meter

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

Transcription:

S L 1 16 8 7 8 9 M e n u 4 5 6 1 2 3 E n te r 0 Transmitter: Flow range: 0 ~ ±40ft/s (0 ~ ±12m/s) Accuracy: ±1.0% Repeatability: 0.3% Outputs: OCT, 0-9999 KHz

Sl 1168 Ultrasonic Flowmeter Brochure Series1168 Ultrasonic Flowmeter uses the latest digital technology and low-voltage broadband pulse transmission. The instrument is tolerant of liquids with small amounts of air bubbles suspended solids found in most industrial environments. With distinctive features such as high accuracy, high reliability, the MPU in the instrument provides unique digital signal processing and a relevant test programs. This flowmeter provides long-term no-drift measurements and sts the operating software to adjust parameters accding to changing conditions. Simple operation Designed to be user friendly & easy to operate Very simple and convenient

Features Compact design, easy to install. Using weather-proof robust housing materials: crosion-resistant, rust-resistant, freeze resistant. Designed to be user friendly, easy to operate. Users can finish installations within just 20 min. Suitable f measurement in many different wking conditions. Transducers SL1168 is equipped clamp-on transducers made with SiteLab patented technology, which is suitable f metal, PVC and other pipe materials, lined pipe. The transducers use robust material with the high perfmance piezoelectric crystals, which will high accuracy and good perfmance during measurement. At the same time, it's easy and convenient to install. Users only need to fix it on the pipe with the pipe strips, and setup the transducer spacing accding to the prompt of the meter. It only takes minutes to complete.

SL1168 Ultrasonic Flowmeter SL 1168 Ultrasonic Flowmeter uses advanced framewk configuration with compact design. It consists of five main parts: enclosure, LCD display, power supply board, PCB mainboard and operating panel. This configuration increases the reliability of the product and decreases the cost and maintenance as well. The convenient digital menu operation can easily be used to setup the pipe size, pipe material, pipe thickness, fluid type, output signal and other parameters. Flow transmitter Clamp-on transducers Installation Locking Collar Grease coupling compound Pipe strips

Application SL1168 Ultrasonic Flowmeter is aim at irrigation application. Compact fm design, easy to operate High dynamic response measurement with economical price, also, the intelligent control makes the products carrying fault alarm alerts and self checking function, which highly increase the wking efficiency. Garden Grapery Cropland Cropland

Quick start setup Windows operating software is used f setup within 5minutes and f easy debugging and installation of the flowmeter. F example, with a pipe diameter of DN200, water, pipe material carbon steel, pipe wall thickness 6mm, no pipe inside liner, the SL1168 can be programmed as follows! Pipe outside diameter: Pi pe Ou t e r Di a me t er 200 mm Pipe Wall Thickness 6 mm Menu 1 1 keys to enter Window M11, and enter the pipe outside diameter, and then press the 6mm, and press the Pipe material: key. 1 2 keys to enter Window M12, pipe wall thickness: key. Pi pe Ma t e r i a l [ 14 0. Ca r b on St eel move the 1 4 key to enter Window M14, press the key to select pipe material: carbon steel. key, L i nner Ma t e r i a l [ 16 0. No n e, No L i n er Liner material parameters: Press 1 6 keys to enter Window M16, and press the key, move the key to select liner material: No Liner F lu i d T y p e [ 20 0. Wa t er Fluid type 2 0 keys to enter Window M20, press the key, move the key to select fluid type, Display the measuring result Menu 0 1 keys to enter Window M01 f the flow rate. T r a n s duc e r T y pe [23 0. St and a rd F lo w 0.112 9 m3 /h *R Vel 1.0415 m/s Tr a n s duc e r Mount i ng 0. V Transducer Spacing 159.86 mm Transducer type 2 3 keys to enter Window M23, press the key, move the key to select Transducer type Transducer mounting methods 2 4 keys to enter Window M24, press the key, move the key to select Transducer mounting methods. Adjust Transducer spacing 2 5 keys to enter Window M25, accurately install the transducer accding to the displayed transducer mounting spacing.

Transducer installation steps The installation of the ultrasonic flowmeter is the simplest one in all the flowmeters. Users only need to select an appropriate measurement point, input the parameters f the measurement point pipe to the flowmeter, and install the transducer to measure. 1. Select measurement point 2. Mark a hizontal line 8. Apply the second one with the same way 3. Select a second point on the hizontal line using the transduce r spacing displayed by the meter 7. Transducer installation is done Transducers installed 4 Apply the coupling compound to the bottom of the transducers. 6. Fix the transducers with pipe straps. 5. Place the transducers on the selected measurement points.

Specifications Perfmance specifications Flow range: 0 "40 ft /s (0 "12 m/s) Accuracy: "1.0% Repeatability: 0.3% Pipe size: 1 in to 16 in (25mm ~ 400mm) Functional specifications Output: 0#9999Hz, OCT Power supply: 10 ~ 36 VDC$200mA(MAX) Keypad: 16 (4X4) touch key-press Display: 20X2 alphanumeric, backlit LCD Temperature range: Transmitter: -10 C ~ 50 C Transducer: -40 C ~ 80 C (Standard) Humidity: Up to 99% RH, non-condensing Physical specifications Transmitter: NEMA 4X(IP65) Transducer: Encapsulated design Weight: Transmitter: approximately 1.5 lb (0.7kg) Transducer:approximately 1.8lb (0.8kg) Agent: Agent: