HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX, IECEx)

Similar documents
HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)

Magnetostrictive Level Transmitter

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Level Plus. CHAMBERED Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

A Higher Level of Performance. Data Sheet. Hydrobar. Level Transmitters. For more information, please visit >

Magnetostrictive Level Transmitter

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Data Sheet

Level Plus. SoCLEAN Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

Level Plus. RefineME Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Data Sheet

Gladiator G1 Series. Microwave Waveguide Information. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection

Gladiator G1 Series. Microwave Waveguide Information. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection

AT200 External Mount Magnetostrictive Level Transmitter

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

Sultan Flow. Data Sheet. Overview. A Higher Level of Performance. Real Time Flow Measurement for Liquids.

Sultan. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Submerged Interface Level Measurement.

Sultan Liquid- Acoustic Wave Technology

ORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.

AT100S Magnetostrictive Level Transmitter. Sanitary magnetostrictive level transmitter K-TEK Products

Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology

Sultan. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Submerged Interface Level Measurement.

Level Plus Liquid-Level Sensors With Temposonics Technology

Liquid Level Transmitter Model MC420 Analog Output

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

FICHA TÉCNICA DE PRODUTO

Sultan Flow. Data Sheet. Overview. A Higher Level of Performance. Real Time Flow Measurement for Liquids.

Level Measurement Continuous level measurement Radar transmitters

ORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

7250 Series HR Digital Stik

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology

Features. NULL-KOTE Circuitry Makes the sensor immune to adverse effects of conductive coating build up.

Sultan Acoustic Wave Series

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

D E S C R I P T I O N F E A T U R E S A P P L I C A T I O N S. The Enhanced Jupiter Magnetostrictive level transmitter

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Kotron Sentinel Model 804 RF Level Transmitter

Single-Channel Safety Barriers Series 9001

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

DREXELBROOK DREXELBROOK. Impulse. Series IMPULSE. IMPULSE Series. Guided Wave Radar (TDR) for Total Level and Volumetric Measurements DATA SHEET

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Isolators A3/1. Vibration Transducer Supply Unit Series

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

ORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For oils and fuels Model LF-1

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Kotron Sentinel Model 804 RF Level Transmitter

Rosemount 148 Temperature Transmitter

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

SITRANS LR 300: High Performance Radar for Level Measurement

Two-channel safety barriers Series 9002

Isolators A3/1.

Gladiator. Gen 3 Microwave Switch Series. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection Circular Polarisation

Level Measurement Continuous level measurement Radar transmitters

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Submersible pressure sensor For superior applications Model LF-1

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Coriolis Massflowmeter

Isolators A3/1.

Wireless Base Radio. Wireless Transmitters

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Kotron Model 82 CE RF Level Transmitter

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Humidity Sensor/Transmitter Assembly

Positioner with HART Communication Type 3780

0 2 1 â Ó. itemp HART TMT182. Technical Information

PAD - Heavy Duty Differential Pressure Trasmitter

Installation guide 971 SmartRadar LTi

Two-channel safety barriers Series 9002

RF Capacitance Level Controls

Model Sono-Trak Transit Time

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.

RF Capacitance Level Controls

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Liquid-Level Transmitter Model M-Series Analog Output

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

KMS-2 Exd Magnetostrictive Level Transmitter

SMARTLINE LEVEL SLG700

Process display RIA 261

Rosemount 148 Temperature Transmitter

SITRANS T measuring instruments for temperature

Level Lance Model 5100

Technologies, Solutions, and Applications. Guided Wave Radar for Level

Specification DataFile

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB82 2-wire conductivity transmitters

Transcription:

Heading Product Name A Higher Level of Performance Data Sheet HAWK Magnetostrictive Level Transmitter For more information, please visit > www.hawkmeasure.com

Model HLT Transmitter with Analog Output and HART Product overview The Model HLT liquid level transmitter satisfies the demand for an analog communication interface for sightglass (bypass chamber) applications. The Model HLT transmitter provides a 4-20 ma output for most magnetic level gauge manufacturers and allows for mounting external to the chamber without interrupting the process. Model HLT transmitters are modular in design offering a selection of mounting options and pipe styles. The modularity also offers simple field replacement. Subject to local electrical codes, the sensing element and electronics can be removed from the transmitter pipe without disturbing the operation of the process saving both time and money. The model HLT transmitter uses HART communication for setup, calibration, and diagnostics. HART can be utilized via a hand-held communicator or with the HAWK setup software via a PC and HART to serial converter. The optional on-board display and keypad is also provided for local indication and programming. Features Applications Markets 4 to 20 ma Analog Output with HART No Scheduled Maintenance or Recalibration High Accuracy and Repeatability AMS Aware Explosion-proof and/or Intrinsically Safe Inventory Control Process Vessel Bypass Chamber Petroleum and Petrochemical Power Generation Specialty Chemical All specifications are subject to change. Contact HAWK for specifications and engineering drawings that are critical to your application. Drawings contained in this document are for reference only. 2

Product specifications Parameters LEVEL OUTPUT Specifications Measured Product level variable: Total Level or Interface Level Output signal / Protocol: 4 to 20 ma with HART Order length: Rigid pipe: 508 mm (20 in.) to 3658 mm (144 in.) Contact factory for longer lengths. Order length equals the measurement range plus the inactive zone. Non-linearity: 0.02% F.S. or 0.794 mm (1/32 in.) * * Whichever is greater Repeatability: 0.01% F.S. or 0.381 mm (0.015 in.) * (any direction) Contact factory for alternative materials. COMPATIBILI TY MRA3/4 chamber compatibility: ELECTRONICS Input voltage: Fail safe: Reverse polarity protection: Lightning/ Transient protection: CALIBRATION Zero adjust range: Span adjust range: HAWK K-Tek Jerguson Kenco Wika Klinger Quest-Tec Vize Penberthy Others 10.5 to 36.1 Vdc, 28 Vdc maximum for I.S. ATEX approval High (21.4 ma), or Low (3.8 ma) Series diode Stage 1: Line-to-ground surge suppression; IEC 61000-4-5 Stage 2: Line-to-line and line-to-ground transient suppressors; IEC 61000-4-4 Anywhere within the active length Full scale to 152 mm (6 in.) from zero Parameters ENVIRONMENTAL Enclosure rating: Humidity: Operating temperatures: FIELD INSTALLATION Housing dimensions: Specifications NEMA Type 4X 0 to 100% relative humidity, non-condensing Electronics: -40 C (-40 F) to 71 C (160 ºF) Sensing element: -40 C (-40 F) to 125 150 C (257 F) Higher temperatures are available using a small insulation pad.. Contact factory for specific temperature ranges. Single cavity: 127 mm (5 in.) by 123 mm (4.85 in.) 121 mm (4.75 in.) O.D. MOUNTING Rigid pipe: Hose clamp to chamber WIRING Connections: 2-wire shielded cable twisted pair, ELECTRICAL CONNECTIONS Dual Single Compartment Cavity: Housings: ¾ in. conduit 3/4 in. opening, conduit opening, M20 M20 for for ATEX Version Single Cavity: 3/4 in. conduit version opening, M20 for ATEX Version DISPLAY Measured variables: Product level Size: 13 mm (0.5 in.) Number of digits: 16 3

Agency Approvals explosion proof FM 3615 C22.2 No. 30 Class I, Division 1, Groups B, C and D Class II, Division 1, Groups E, F and G Division 1, NEMA Type 4X Explosion-proof housing required 90 electronic mount is only for Groups C and D Intrinsically safe FM 3610 C22.2 No. 157 en 50020 Class I, Division 1, Groups A, B, C and D Class II, Division 1, Groups E, F and G Class III, T4 Division 1, NEMA Type 4X PTB 00 ATEX 2069X II 1/2 G bzw. II 2 G EEx ia IIB T4 bzw. EEx ia IIA T4 HART ART handheld communicator programming The Model HLT transmitter programming can also be performed by using handheld HART communicator device such as the Rosemount 375 or 475. Setpoint programming using the display Any Model HLT transmitter that is purchased with a display has the ability to adjust the 4 and 20 ma setpoints by pressing the appropriate button located at the bottom of the display. 4

Product dimensions and mounting HAWK offers the Model HLT transmitter configured for external mounting to most Magnetic Level Gauges (MLG) (see Figure 1 ). The Model HLT can be ordered with the standard 5/8 inch OD pipe or the optional 1/2 inch OD pipe from 508 mm (20 in.) to 3658 mm (144 in.). Stainless steel hose clamps are typically used to secure the Model HLT to the MLG. The Model HLT transmitter Measuring Range is equal to the Order Length minus the Inactive Zone. The Measuring Range should equal the measuring range of the MLG. Ensure that there are no obstructions that will limit the ability to mount the Model HLT on the MLG. Current Pulse Start pulse Magnetic Float Assembly 132 mm (5.19 in.) 203.2 mm (8 in.) Sensor Wire Inactive Zone 95.3 mm (3.75 in.) Measuring Range Order length Inactive Zone 76.2 mm (3 in.) Figure 1 5

Product dimensions and mounting HAWK offers the Model HLT transmitter configured for external mounting to most Magnetic Level Gauges (MLG) (see Figure 2 ). The Model HLT can be ordered with the standard 5/8 inch OD pipe or the optional 1/2 inch OD pipe from 508 mm (20 in.) to 3658 mm (144 in.). Stainless steel hose clamps are typically used to secure the Model HLT to the MLG. The Model HLT offers an optional 90 degree fitting for an MLG with both top and bottom flanges. The 90 degree fitting allows the electronic head of the Model HLT to be positioned to the side of the pipe allowing for simpler mounting. The Model HLT transmitter Measuring Range is equal to the Order Length minus the Inactive Zone. The Measuring Range should equal the measuring range of the MLG. Ensure that there are no obstructions that will limit the ability to mount the Model HLT on the MLG. 2 ft. 9 6 3 1 ft 9 6 3 0 Figure 2. Model MRA3/4 mounting, top and bottom flange Figure 2 6

Ordering information for FM-CSA approvals Agency Approvals 1 Model M Magnetostrictive Gauge 2 Type R Analog Transmitter 3 Approval Agency F FM FM 4 CSA CSA 4 Output 3 4-20 ma High Gain w/ Display, 1 Loop All 4 4-20 ma High Gain w/o Display, 1 Loop All B Single cavity (XP) 5 Housing Type C D Dual cavity (XP)* Single cavity (XP) w/ Display window All E Dual cavity (XP) w/ Display window* *Dual cavity requires electronic mount 90 degree bend 1 Integral Electronics All 3 90 degree bend, housing top left 6 Electronics Mounting 4 90 degree bend, housing top right 5 90 degree bend, housing bottom left 6 90 degree bend, housing bottom right All 7 Sensor Pipe B Industrial Pipe (5/8 in OD) All R Industrial Pipe (1/2 in OD) All 8 Material of Construction 1 316L SS 9 Process Connection Type X None 10 Process Connection Size X None 11 Temperature Element 0 None 12 Unit of measurement 13,14,15,16,17 Length 14 Special M U S E Metric US Customary XXX.XX Inches XXXXX mm Standard product Engineered Special (>144 w/ factory approval) 7

Ordering information for ATEX and IECEx approval Agency Approvals 1 Model M Magnetostrictive Gauge 2 Type R Analog Transmitter E ATEX Approval ATEX Ex d or Ex ia H IECEx Approval IECEx Ex d 3 Approval Agency B INMETRO Approval INMETRO Ex d K KC Approval KC Ex d P CCoE Approval CCoE Ex d 4 Output 3 4-20 ma High Gain w/ Display, 1 Loop All 4 4-20 ma High Gain w/o Display, 1 Loop All B Single cavity (XP) C D Dual cavity (XP)* Single cavity (XP) w/ Display window ATEX, IECEx, INMETRO, KC, CCoE, Ex d Only E Dual cavity (XP) w/ Display window* G Single cavity (XP) 5 Housing Type H J Dual cavity (XP)* Single cavity (XP) w/ Display window ATEX, Ex ia IIA K Dual cavity (XP) w/ Display window* R Single cavity (XP) S T Dual cavity (XP)* Single cavity (XP) w/ Display window ATEX, Ex ia IIB U Dual cavity (XP) w/ Display window* *Dual cavity requires electronic mount 90 degree bend 1 Integral Electronics All 3 90 degree bend, housing top left Ex d Only 6 Electronics Mounting 4 90 degree bend, housing top right Ex d Only 5 90 degree bend, housing bottom left Ex d Only 6 90 degree bend, housing bottom right Ex d Only 7 Sensor Pipe B Industrial Pipe (5/8 in OD) All R Industrial Pipe (1/2 in OD) All 8 Material of Construction 1 316L SS 9 Process Connection Type X None 10 Process Connection Size X None 11 Temperature Element 0 None 12 Unit of measurement M Metric U US Customary 13,14,15,16,17 Length 18 Special S E XXX.XX Inches XXXXX mm Standard Engineered Special (>144 w/ factory approval) 8

Programming and hardware accessories HARDWARE HarDWare PART Part NUMBER NuMBer Hart to rs-232 adapter (SMAR H1-311) 380068 FM APPROVED 9

HAWK, Since 1988 Hawk Measurement Systems Pty Ltd (HAWK) was established in 1988. It's founding members saw the universal requirement of various industries requiring improved process control and efficiency in their operations. We Can Help HAWK understands the difficulties customers face when seeking accurate level measurement. Every application is different, involving a multitude of environmental factors. This is where HAWK excels. Our aim is to ensure that customers not only feel comfortable with our technology, but that we also to ensure a consistent and reliable solution is in place for the long term. We believe that a combination of application and product expertise, as well as forward thinking and proactive support policies are the foundation of successful customer-supplier relationships. 10

Progressive Technical Support HAWK believes that the future of the Level Measurement Industry revolves around the quality of pre and post sales - support. Our aim is for all sales & support staff to be product experts, and more importantly application experts making our customers applications as efficient and consistent as possible. Remote Innovation HAWK understands the need for immediate technical assistance. Knowledge Sharing HAWK believes that knowledge sharing is key to creating long term relationships. Empowering our customers and our worldwide distribution network, whilst being available at all times to lend a helping hand, is the perfect recipe for long term solutions and relationships. HAWK openly extends an invitation to share our 25 years of level measurement experience, and ensure that your day to day processes are efficient, understood, and always working. The HAWKLink 3G communication device allows any computer with internet access and our free GosHawK diagnostic & calibration software; to dial in, calibrate, test, and check the performance of HAWK products. This innovative system allows our Global Support Team to assist with commissioning and after sales service of HAWK equipment worldwide. Measurement problems are addressed as they happen; not days or weeks later. 11

A Higher Level of Performance Hawk Measurement Systems Hawk Measurement (Head Office) 96 Glenn Street 15-17 Maurice Court Lawrence, MA 01843, USA Nunawading VIC 3131, AUSTRALIA Phone: +1 888 HAWKLEVEL (1-888-429-5538) Phone: +61 3 9873 4750 Phone: +1 978 304 3000 Fax: +61 3 9873 4538 Fax: +1 978 304 1462 info@hawk.com.au info@hawkmeasure.com For more information and global representatives: www.hawkmeasure.com Represented by: DOC-MLT-ICSA-FM-DAT 0315