SINEAX G 537 Transducer for Phase Angle Difference

Similar documents
SINEAX G 536 Phase Angle or Power Factor Transducer

SINEAX U 553 Transducer for AC Voltage

SINEAX I 552 Transducer for AC current

EMBSIN 281 G Power factor transducer

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

Plug-in module SIRAX TI 807 Passive DC signal isolator

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX TV809, 1 channel Programmable Isolating Amplifier

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

SINEAX B 811 Power Pack with additional Functions

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

RISH Ducer E15 TRANSDUCER FOR AC CURRENT OR AC VOLTAGE WITH DIFFERENT CHARACTERISTICS

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

RISH Ducer E13 3 channel transducer for AC current and voltage

SINEAX TI 807 Passive DC signal isolator

Theta 20A / 20V. Technical Data Sheet. Special Features

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

RISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

KINAX WT 707 Transmitter for angular position

ZIEGLER PRO-P Power / Phase Angle / Power Factor Transducer

SUBJECT TO CHANGE WITHOUT NOTICE

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

Theta Hz. Technical Data Sheet. Special Features

KINAX 2W2 Programmable Transmitter for Angular Position

KINAX WT 717 Programmable Transmitter for Angular Position

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

KINAX 3W2 Transmitter for angular position

KINAX SR 719 Programmable Transmitter for Position Feedback

SINEAX V604s Programmable multifunctional transmitter

SINEAX V 604s Programmable multifunctional transmitter

EURAX UI 505, Combined Transducer for AC current and AC voltage

SINEAX / EURAX 2I1 Passive DC signal isolator

RISH Ducer IXX / VXX Series (TRMS/Average) Transducer for AC current / AC Voltage (Single or Dual Output)

for DC currents or voltages, temperature sensors, remote sensors or potentiometers Application Principle of operation (Fig. 3) Features / Benefits

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

Rudder or propeller angular position transmitter KINAX WT720

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters

SINEAX VC 603, Programmable combined transmitter/alarm unit

For non-electrical quantities

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

EURAX VC 603 Programmable combined transmitter/alarm unit

SINEAX V 604 Programmable universal transmitter

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

Contactors and Contactor Assemblies

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

PROGRAMMABLE TRANSDUCER OF DC CURRENT AND DC VOLTAGE SIGNALS P20H TYPE

CP-E range Benefits and advantages

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Programmable AC Voltage Transducer MT416

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

ZITARES CC Constant current control gear, 2-channel, dimmable

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

CP-T range Benefits and advantages

Isolators A3/1. Vibration Transducer Supply Unit Series

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

CP-T range Product group picture

Programmable AC Current Transducer MT418

ZITARES NCD FX-30 Non-SELV (isolated), constant current control gear, 1-channel, dimmable

ZITARES CCD FX-20 25W SELV (isolated), adjustable functions and current, 1-channel, dimmable

LED Driver Compact fixed output

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

LED Driver Compact fixed output

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

ZITARES CC Constant current control gear, 1-channel, dimmable

ZITARES NCD FX-30 Non-SELV (isolated), constant current control gear, 1-channel, dimmable

LED Driver Compact dimming outdoor

LED Driver Linear / area fixed output

Measuring current transformers of the W, W series

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

PHASED OUT. LED Driver Compact fixed output. Driver LCI 20W 350mA 900mA TOP C TOP series

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 35W 350mA 900mA TOP lp TOP series

Primary switch mode power supplies Product group picture

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 150mA 400mA TOP C TOP series. Product description

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 20W 150mA 400mA TOP lp TOP series. Product description

27/04/2015

XUA1 - AC Voltage and phase balance relay

0 2 1 â Ó. itemp HART TMT182. Technical Information

DIGITAL PANEL METER N24 AND N25 METER SERIES

For Immediate Delivery call KMParts.com at (866)

Technical features table for miniature circuit-breakers SH 200 Series

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 350mA 900mA TOP C TOP series

Thermistor motor protection relays

LED Driver Compact dimming outdoor

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

ZITARES ICD SELV constant current control gear, 2-channel, dimm- and programmable

Type CP-S, CP-C & CP-A Switch mode

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

LED Driver Compact fixed output

Isolating Repeater Input Series 9163

Transcription:

Carrying rail housing P/0 pplication The transducer SINX G 5 (Fig. ) converts the phase angle difference of two synchronised supplies into a load independent DC current or a load independent DC voltage proportional to the measured value. The transducer fulfi ls all the important requirements and regulations concerning electromagnetic compatibility MC and Safety (IC 00 resp. N 00). It was developed and is manufactured and tested in strict accordance with the quality assurance standard ISO 00. Fig.. Transducer SINX G 5 in housing P/0 clipped onto a top-hat rail. Features / Benefits Measuring inputs: Sine, rectangular or distorted wave forms of nominal input voltages with dominant fundamental waves Measured variables Phase angle difference Nominal input voltages Measuring range limits 0 to 0 V ± 0 to < ± 0 el Measuring output: Unipolar, bipolar or live zero output variables Measuring principle: Measurement of the zero crossing interval C/DC power supply / Universal Standard as marine version per Lloyd s Register of Shipping Nominal input voltage : Sensitivity: Own consumption: Overload capacity: Measured quantities Number of applications Generator and bus bar 0 0 V or 0 0 V (max. 0 V with power supply from voltage measuring input) 0 0% <.5 m per measuring input Duration of one application Interval between two successive applications, x perman. x 0 s 0 s But max. 4 V with power supply from voltage measuring input. Technical data General Measured quantity: Measuring principle: Phase angle difference Measurement of the zero crossing interval Measuring output Load independent DC current: 0 to 0 0 m resp. live-zero 5 to 4 0 m ± to ± 0 m Measuring inputs Measuring range: Nominal frequency f N : See Section «Specification and ordering information» 50 or 0 Hz Burden voltage: Load independent DC voltage: + 5 V, resp. V 0 to 0 0 V resp. live-zero 0. to 0 V ± to ± 0 V Camille Bauer Data sheet G 5 Le 0.0

Load capacity: Voltage limit under R ext = : Current limit under overload: Residual ripple in output current: Nominal value of response time: Other ranges: Max. 4 m 5 V pprox.. x I N at current output pprox. 0 m at voltage output < 0.5% p.p. 4 periods of the measuring frequency, or periods of the measuring frequency Behaviour of output current in different operating states: Generator voltage UG leading (f G = f S ) missing Operating state Bus bar voltage nominal value nominal value missing missing missing With power supply switched on.g. switched off or fault condition unipolar Output bipolar > I N / positive indefi nite indefi nite Test voltage: 50 Hz, min. acc. to N 00-00 resp. 5550 V, inputs versus all other circuits as well as outer surface 50 V, inputs versus each other 00 V, power supply versus output as well as outer surface 40 V, output versus outer surface Power supply C/DC power pack (DC or 40 400 Hz) Table : Rated voltages and permissible variations Rated voltage Tolerance 5 0 V DC, C DC 5 + % 4 0 V DC, C C ± 5% or Power supply from voltage measuring input: 4 0 V C or 5 0 V C Option: Connect to the low tension to terminals and 4 V C or 4 0 V DC Power consumption: pprox. W resp. 4 V Installation data Mechanical design: Housing P/0 ccuracy (acc. to N 0 ) Reference value: Δϕ = 0 Basic accuracy: Class 0.5 Reference conditions mbient temperature 5 0 C Material of housing: Mounting: Mounting position: Weight: Lexan 40 (polycarbonate), fl ammability Class V-0 acc. to UL 4, self-extinguishing, non-dripping, free of halogen For rail mounting ny pprox. 0. kg Input voltage = 0.. U S Frequency f N ± 0% Wave form Sine Power supply t nominal range Output burden Δ R ext max. Safety Protection class: II (protection isolated, N 00) Housing protection: IP 40, housing (test wire, N 0 5) IP 0, terminals (test fi nger, N 0 5) Contamination level: Overvoltage category: III Connecting terminals Connection element: Permissible cross section of the connection leads: Screw-type terminals with indirect wire pressure 4.0 mm single wire or x,5 mm fi ne wire nvironmental conditions Operating temperature: 0 to + 55 C Storage temperature: 40 to + 0 C Relative humidity of annual mean: 5% ltitude: 000 m max. Indoor use statement! Rated insulation voltage (against earth): 0 V resp. 400 V, inputs 0 V, power supply mbient tests N 0 0--: Vibration 40 V, output cceleration: ± g Data sheet G 5 Le 0.0 Camille Bauer

Frequency range: Number of cycles: N 0 0--: cceleration: 0 50 0 Hz, rate of frequency sweep: octave/minute 0, in each of the three axes Shock 50 g chocs each in directions Germanischer Lloyd Type approval certifi cate: mbient category: Vibration: No. - HH C 0. g N 0 0--/-/-: Cold, dry heat, damp heat IC 000-4-/-/-4/-5/- N 55 0: lectromagnetic compatibility Output characteristic unipolar live-zero bipolar = 0 = 0. 0 0 Legend: = Input = Input start value = Input end value = Output = Output start value = Output end value Table : Specification and ordering information Description *Blocking code no-go with blocking code rticle No./ Feature SINX G 5 Order code 5 - xxxx xxx 5 Features, Selection. Mechanical design Housing P/0 for rail mounting 4. Nominal input frequency 50 Hz 0 Hz [Hz] 0 to 500 Hz With power supply from measuring input min. 40 Hz, max. 400 Hz. Nominal input voltage Generator and bus bar: = 00 V = 0 V [V] 0 to 0 V With power supply from measuring input min. 4 V, max. 0 V, see feature, lines and 4 phase system: Input voltage = phase to phase voltage Camille Bauer Data sheet G 5 Le 0.0

Description *Blocking code no-go with blocking code rticle No./ Feature SINX G 5 Order code 5 - xxxx xxx 5 Features, Selection 4. Measuring range 0 0 0 el [ el] Measuring range within 0 0 + 0 el, but unambiguous output value up to 5 0 + 5 el; measuring span 0 el 5. Output signal 0 0 m 4 0 m 0.00 to 0 < 0, [m].00 0.00 to 0 0 0 (symmetrical) 5 to < (4 0) ( / = / 5) 0 0 V 0.00 to 0 < 0, [V].00 0.00 to 0 0 0 (symmetrical) Z 0. to 0 ( / = / 5) = Output start value, = Output end value. Power supply 5 0 V DC, C 4 0 V DC, C Internal from measuring input (4 0 V C) Internal from measuring input (5 0 V C) 4 Connect to the low tension 4 V C / 4 0 V DC 5. Response time 4 periods of the input frequency (standard) periods of the input frequency periods of the input frequency periods of the input frequency 4 * Lines with letter(s) under no-go cannot be combined with preceding lines having the same letter under SCOD. 4 Data sheet G 5 Le 0.0 Camille Bauer

lectrical connections 0 0 0 = Measuring input Generator voltage U S = Measuring input Bus bar voltage = Measuring output = Power supply (U) (U) (U) (U) (U) (U) Fig.. Power supply connected to terminals and. Fig.. Power supply internal from measuring input, without separated power supply. Fig. 4. Power supply connected to the low tension terminal side and Dimensional drawing.5 0. 4. 0 Fig. 5. Housing P/0 clipped onto a top-hat rail (5 x 5 or 5 x.5 mm, acc. to N 50 0). Standard accessories Operating Instructions in three languages: German, French, nglish Rely on us. Camille Bauer Ltd. argauerstrasse CH-50 Wohlen / Switzerland Phone: + Fax: + 5 5 info@camillebauer.com www.camillebauer.com Subject to change without notice dition 0.0 Data sheet G 5 Le