TEST DATA ANALYSIS. Presented by. The National Center for Credibility Assessment

Similar documents
Application note Scoring GSR during stressful tasks: This application note will describe one method to automatically score GSR responses.

VivoSense. User Manual - Equivital Import Module. Vivonoetics, Inc. San Diego, CA, USA Tel. (858) , Fax. (248)

Combined effects of low frequency vertical vibration and noise on whole-body vibration sensation

Page 1 of 8 42 Aero Camino, Goleta, CA Tel (805) Fax (805)

ME scope Application Note 01 The FFT, Leakage, and Windowing

CORONA CHARTS EXPLAINED Copyright by eminiz.com Permission granted for free distribution

Computer Evaluation of Exercise Based on Blood Volume Pulse (BVP) Waveform Changes

Combinational logic: Breadboard adders

EE469B: Assignment 2 Solutions

Impulse Response as a Measurement of the Quality of Chirp Radar Pulses

Signal Processing for Digitizers

EE 230 Experiment 10 ECG Measurements Spring 2010

Validation of the Happify Breather Biofeedback Exercise to Track Heart Rate Variability Using an Optical Sensor

ELECTRONIC AND ELECTROMECHANICAL TESTER FOR PHYSIOLOGICAL SENSORS JOHN BRYANT GRACE JR.

Biomedical Engineering Evoked Responses

NCSS Statistical Software

WE HAVE previously reported the

BME 405 BIOMEDICAL ENGINEERING SENIOR DESIGN 1 Fall 2005 BME Design Mini-Project Project Title

Low-Frequency Transient Visual Oscillations in the Fly

Real Analog - Circuits 1 Chapter 11: Lab Projects

INVITATION FOR QUOTATION. TEQIP-II/2013/UP1G01/Shopping/43

c4nnula is used which does not expand and contract like an uninjured

FEATURES OF VOLTAGE PULSE PLETHYSMOGRAPHY

ECE 201 LAB 8 TRANSFORMERS & SINUSOIDAL STEADY STATE ANALYSIS

P R E S E N T E D B Y. K A M A R U L A M I N A B D U L L A H Dip. MED. IMG., BSc. MED. IMG. (UiTM)

Page 2 A 42% B 50% C 84% D 100% (Total 1 mark)

Design on Electrocardiosignal Detection Sensor

SAMPLING NOTES. Scanned January 13, Revision 1.0

Describing Data Visually. Describing Data Visually. Describing Data Visually 9/28/12. Applied Statistics in Business & Economics, 4 th edition

Biomedical Signals. Signals and Images in Medicine Dr Nabeel Anwar

LABORATORY 4. Palomar College ENGR210 Spring 2017 ASSIGNED: 3/21/17

16 Histograms. Using Histograms to Reveal Distribution

EG medlab. Three Lead ECG OEM board. Version Technical Manual. Medlab GmbH Three Lead ECG OEM Module EG01010 User Manual

TECHNICAL APPENDIX FOR: POSSIBLE PARANORMAL COMPONENTS OF ANTICIPATION: PSYCHOPHYSIOLOGICAL EXPLORATIONS

Optimizing Images and Video for an LED Display

BIO-ELECTRIC MEASUREMENTS

Lesson 12: The Scale Factor as a Percent for a Scale Drawing

10. Phase Cycling and Pulsed Field Gradients Introduction to Phase Cycling - Quadrature images

Graphics packages can be bit-mapped or vector. Both types of packages store graphics in a different way.

MESA 1. INTRODUCTION

ME scope Application Note 02 Waveform Integration & Differentiation

Differential Protection Optimal differential protection for phase shifter transformers and special transformers

TWO DIMENSIONAL DESIGN CHAPTER 6: GRADATION. Dr. Hatem Galal A Ibrahim

Advanced electromagnetism and electromagnetic induction

Linear vs. PWM/ Digital Drives

Tutorial on the Statistical Basis of ACE-PT Inc. s Proficiency Testing Schemes

Design of Arterial Blood Pressure, Heart Rate Variability, and Breathing Rate Monitoring Device. Mastan Singh Kalsi

Arterial pulse waves measured with EMFi and PPG sensors and comparison of the pulse waveform spectral and decomposition analysis in healthy subjects

Specifying A D and D A Converters

Series-Parallel Circuits

A Pilot Study: Introduction of Time-domain Segment to Intensity-based Perception Model of High-frequency Vibration

ENGR 210 Lab 12: Sampling and Aliasing

AGN 008 Vibration DESCRIPTION. Cummins Generator Technologies manufacture ac generators (alternators) to ensure compliance with BS 5000, Part 3.

Biomedical Instrumentation B2. Dealing with noise

Chapter 6 Experiments

DesignCon Noise Injection for Design Analysis and Debugging

Exploring QAM using LabView Simulation *

THE CATHODE RAY OSCILLOSCOPE

Test No. 2. Advanced Scope Measurements. History. University of Applied Sciences Hamburg. Last chance!! EEL2 No 2

Module 10. Assemblies and Corridors. Objectives

2 Oscilloscope Familiarization

Technical Data Sheet

Background Suppression with Photoelectric Sensors Challenges and Solutions

Next Generation Biometric Sensing in Wearable Devices

Scratch LED Rainbow Matrix. Teacher Guide. Product Code: EL Scratch LED Rainbow Matrix - Teacher Guide


29:128 Homework Problems

Pulse Sequence Design and Image Procedures

MOTION GRAPHICS BITE 3623

PhysicsAndMathsTutor.com 1

Lesson 4 Holes and Rounds

Potentiostat. 1.2 Electrochemical Methods

Changing the sampling rate

Designers Series XIII

5.3-The Graphs of the Sine and Cosine Functions

This Land Surveying course has been developed by. Failure & Damage Analysis, Inc. Earthwork

Specifying a Channel Through Impulse Response. Charles Moore July 9, 2004

Trim (Aluminum Substrate)

ESSENTIAL MATHEMATICS 1 WEEK 17 NOTES AND EXERCISES. Types of Graphs. Bar Graphs

Using Figures - The Basics

The Integument Laboratory

Side - straight line on the edge of a shape Vertex or Corner - where two sides meet Shapes have an inside and outside.

How to define Graph in HDSME

Fourier Theory & Practice, Part I: Theory (HP Product Note )

THE AMPLIFIER. A-B = C subtractor. INPUTS Figure 1

Chapter 4 Results. 4.1 Pattern recognition algorithm performance

EXPERIMENT 7 The Amplifier

Square Wave Testing for Frequency Response of Amplifiers

Lab 6 Prelab Grading Sheet

G 1 3 G13 BREAKING A STICK #1. Capsule Lesson Summary

Click to edit Master Gtle style

SimSE Player s Manual

Hundreds Grid. MathShop: Hundreds Grid

VISUOMOTOR PROGRAM DESCRIPTION AND OVERVIEW

Electric Circuit Fall 2016 Pingqiang Zhou LABORATORY 7. RC Oscillator. Guide. The Waveform Generator Lab Guide

A time shift delay or advances the signal in time by a time interval +t 0 or t 0, without changing its shape.

Excel Manual X Axis Label Below Chart 2010 >>>CLICK HERE<<<

Emission Limits for Customer Facilities Connected to the Hydro-Québec Transmission System

The Unique Role of Lucis Differential Hysteresis Processing (DHP) in Digital Image Enhancement

POWER SYSTEMS QUALITY Topic 5: Principles for Controlling Harmonics

Transcription:

TEST DATA ANALYSIS Presented by The National Center for Credibility Assessment April 2011

OBJECTIVES Identify and discuss 12 current diagnostic features used in evaluating data for all three physiological waveforms: Respiration Five RLL features One non-rll feature 2

OBJECTIVES Diagnostic Features Electrodermal Activity (EDA) One primary feature Two secondary features Cardiovascular One primary feature Two secondary features 3

OBJECTIVES Review current scoring procedures for each physiological waveform using 3 & 7 position numerical scales 4

HISTORICAL PERSPECTIVE In 2002-2003, Mr. Don Krapohl and Dr Stuart Senter, NCCA Research Division, accomplished extensive literature review to determine how many of the 20 diagnostic features (at that time) could be validated through research 5

HISTORICAL PERSPECTIVE Their exhaustive review indicated 12 diagnostic features could be supported by replicated research: Respiration (6 features): RLL: Apnea-blocking, suppression, progressive decrease in amplitude, decrease in rate and change in I/E ratio Non-RLL: Temporary increase in baseline 6

HISTORICAL PERSPECTIVE Krapohl & Senter s research (cont d): Electrodermal activity (EDA) (3 features): EDA amplitude EDA complexity EDA duration Cardiovascular (3 features): Baseline arousal (phasic response) Duration Decrease in rate (pulse rate deceleration) 7

HISTORICAL PERSPECTIVE On 23 Aug 2006, extensive changes were incorporated into NCCA s curriculum 8

RESPIRATORY SYSTEM 9

RESPIRATORY WAVEFORM Typically, the normal resting cyclic rate is 12 to 18 breaths per minute. However, this rate may vary due to a person's physical attributes and/or physical conditioning. 10

RESPIRATORY WAVEFORM Respiratory changes may be considered responses when occurring in a timely manner to an applied stimulus (reviewed test question) and There is no excessive noise on the signal of interest at stimulus onset 11

RESPIRATORY WAVEFORM What is considered a timely response in the respiratory tracing? Should occur within Response Onset Window (ROW): Stimulus onset to include first complete respiratory cycle past answer cycle 12

RESPIRATORY WAVEFORM Response Onset Window 13

RESPIRATORY WAVEFORM Five respiration line length (RLL) diagnostic features: Apnea - blocking Decrease in rate Change in I/E ratio Decrease in amplitude Progressive decrease in amplitude 14

RESPIRATORY WAVEFORM What is RLL? Respiration Line Length (RLL): Procedure for analysis of respiratory tracings. RLL is determined by taking response for specified period of time and visually stretching response into straight line. NCCA utilizes equivalent response window of evaluation 15

RESPIRATION LINE LENGTH In RLL procedure, shorter line length signifies more intense or significant response and will be assigned numerical value. 16

RESPIRATORY WAVEFORM RLL Window of Evaluation 20 Seconds Default Window of Evaluation Value = +1 Value = +1 17

RESPIRATORY WAVEFORM RLL diagnostic features 18

RESPIRATORY WAVEFORM Feature 1: Apnea-Blocking (Suppression) l l - Notes: 1. Feature occurs near end of exhalation portion of respiratory cycle. 2. Apnea-blocking feature does not drop significantly below established baseline 19

RESPIRATORY WAVEFORM Feature 2: Decrease in Rate l l - 20

RESPIRATORY WAVEFORM Feature 3: Change in I/E Ratio l l - 21

RESPIRATORY WAVEFORM Feature 4: Decrease in Amplitude (Suppression) l l - 22

RESPIRATORY WAVEFORM Feature 5: Progressive Decrease in Amplitude (Suppression) l l - 23

RESPIRATORY WAVEFORM Evaluation Procedures If RLL applies to all comparative responses in same analysis spot: Determine response window of evaluation Window of evaluation defaults to response having most duration in analysis spot 24

Establishing Window of Evaluation 12 Seconds 20 Seconds Default Window of Evaluation 25

RESPIRATORY WAVEFORM Evaluation Procedures Time for defaulted window of evaluation is from response onset to response end 26

RESPIRATORY WAVEFORM Evaluation Procedures Equivalent window of evaluation used for all other comparative responses in same analysis spot Variable window for each analysis spot 27

RESPIRATION LINE LENGTH In RLL procedure, when data is visually stretched, shorter line length signifies more intense or significant response and will be assigned numerical value. 28

RESPIRATORY WAVEFORM SCORING EXERCISE 29

RESPIRATORY WAVEFORM Score C1 Against R1 & R2 Score = +1 Score = +1 30

RESIRATORY WAVEFORM Score C1 Against R1 & R2 Score = -1 Score = -1 31

RESPIRATORY WAVEFORM Score C2 against R1 Score = -1 32

RESPIRATORY WAVEFORM Score C1 against R1 Score = -1 33

RESPIRATORY WAVEFORM One non-rll feature remains: Temporary increase in baseline 34

RESPIRATORY WAVEFORM Feature 6: Temporary Increase in Baseline l l - 35

TEMPORARY INCREASE IN BASELINE Value = +1 36

RESPIRATORY WAVEFORM Evaluation Procedures If one comparative response in analysis spot is RLL and other is non-rll, RLL response always gets value RLL features in analysis spot always take precedent over non-rll feature in same analysis spot 37

RESPIRATORY WAVEFORM Score C4 Against R5 RLL Non-RLL Value = +1 38

Respiratory Waveform Non-RLL Evaluation Procedures In scoring non-rll responses, most significant response will get assigned value. Significance is generally determined by the duration of the physiological change 39

Respiratory Waveform Score C4 Against R5? 11 Seconds 15 Seconds Value = -1 40

TEMPORARY INCREASE IN BASELINE Value = +1 41

Respiratory Waveform Non-RLL Diagnostic Feature Temporary Increase in Baseline Could easily become RLL feature if suppression occurs with baseline change If so, RLL scoring procedures apply 42

Temporary Increase in Baseline & Decrease in Amplitude 43

RESPIRATORY WAVEFORM Other Considerations May see exaggerated respiratory cycle in/around answer cycle May be exhibited many forms One cycle of something is nothing principle 44

RESPIRATORY WAVEFORM One Cycle of Something Is Nothing 45

RESPIRATORY WAVEFORM Other Considerations Respiratory channel is often called effector What occurs in respiratory channel has tendency to influence other channels Artifact in respiratory channel may effect ability to evaluate EDA and cardiovascular channels 46

ELECTRODERMAL CHANNNEL 47

ELECTRODERMAL WAVEFORM Two types of tracings are skin resistance (SR) and skin conductance (SC). The electrodermal (EDA) waveform consists of a relatively horizontal tracing indicative of the level of the electrical resistance/ conductance in the skin due to skin hydration. No stimulus applied 48

ELECTRODERMAL WAVEFORM Response Onset Window 49

ELECTRODERMAL WAVEFORM One primary diagnostic feature Amplitude Two Secondary diagnostic features Complexity Duration 50

ELECTRODERMAL WAVEFORM Primary Diagnostic Feature: Amplitude Peak Rise Recovery l l - l l - 51

ELECTRODERMAL WAVEFORM Evaluation Considerations Primary feature: Amplitude Equal amplitude is assigned zero (0) Visually discernable difference gets value of +/-1. 52

ELECTRODERMAL WAVEFORM You Make the Call l l - C Score = +1 l l - R 53

ELECTRODERMAL WAVEFORM Secondary Feature 1: Complex Response l l - 54

ELECTRODERMAL WAVEFORM Evaluation Considerations Complexity Dissimilar responses (simple v complex) Equal levels of amplitude Complexity may be assigned value 55

ELECTRODERMAL WAVEFORM Evaluation Considerations Simple v. Complex Response C Score = -1 R 56

ELECTRODERMAL WAVEFORM Secondary Feature 2: Response Duration l l - C Score = +1 l l - R 57

ELECTRODERMAL WAVEFORM EDA Duration Considerations Response duration is considered in Similar responses only Equal/equivalent levels of amplitude More duration may be assigned value 58

ELECTRODERMAL WAVEFORM Applying Duration Score = -1 c R Score = +1 c R 59

ELECTRODERMAL WAVEFORM Response Duration Score = -1 c 60 R

CARDIOVASCULAR SYSTEM 61

CARDIOVASCULAR WAVEFORM The contraction and relaxation of the heart causes the polygraph instrument to record the systolic stroke, diastolic stroke, and the dicrotic notch, which appears during the diastolic stroke. 62

CARDIOVASCULAR WAVEFORM SYSTOLIC STROKE DIASTOLIC STROKE DICROTIC NOTCH 63

CARDIOVASCULAR WAVEFORM Response Onset Window 64

CARDIOVASCULAR WAVEFORM Diagnostic Features Primary Scoring Feature Baseline arousal (Phasic response) 65

CARDIOVASCULAR WAVEFORM Primary Diagnostic Feature Phasic Response - Short-term change in physiological activity following stimulus presentation. Typically, this response has a relatively rapid onset and may return to the pre-stimulus baseline or establish a new baseline within a period characteristic of the response system. 66

CARDIOVASCULAR WAVEFORM Evaluation Features Phasic Responses l l - l l - 67

CARDIOVASCULAR WAVEFORM Evaluation Considerations Baseline arousal (phasic response) Primary feature More arousal gets value How do I know which response has more arousal? Any visually discernible difference 68

Value = +1 69

CARDIOVASCULAR WAVEFORM Two secondary diagnostic features Duration Decrease in Rate 70

CARDIOVASCULAR WAVEFORM Evaluation Features Determining Response Duration l l - l l - 71

CARDIOVASCULAR WAVEFORM Secondary Evaluation Considerations Impact of duration on the CV waveform Equal/equivalent levels of baseline arousal More duration may be assigned value 72

CARDIOVASCULAR WAVEFORM Secondary Evaluation Considerations Duration as a diagnostic feature Value = -1 73

CARDIOVASCULAR WAVEFORM Evaluation Features Decrease in Rate l l - 74

CARDIOVASCULAR WAVEFORM Secondary Evaluation Considerations Impact of decrease in rate on the CV waveform Considered if baseline arousal does not exist Response exhibiting most amount of duration or degree of change may be assigned value 75

CARDIOVASCULAR WAVEFORM Secondary Evaluation Considerations Decrease in rate as a diagnostic feature Value = -1 76

How to Score a Polygraph Chart This would be easy right? 77

CARDIOVASCULAR WAVEFORM QUESTIONS? 78

SEVEN-POSITION NUMERICAL EVALUATION SCALE -3-2 -1 0 +1 +2 +3 Oct 2009 79

RESPIRATORY SYSTEM 80

RESPIRATORY WAVEFORM 7-Position Scale Respiratory tracing Subtle (+1/-1) Obvious (+2/-2) Dramatic (+3/-3) 81

RESPIRATORY WAVEFORM 7-Position Scale Many times, a +/-2 or +/-3 value may be difficult to assign consistently unless similar respiratory attributes are exhibited or the comparative response is much more significant. 82

RESPIRATORY WAVEFORM 7-Position Scale It is anticipated that most respiratory values will remain in the 0 or +/- 1 category - even in the 7-position scale Occasionally, an examiner may find sufficient respiratory data to assign a value of +/- 2 Very rarely will an examiner assign values of +/- 3 83

ELECTRODERMAL CHANNNEL 84

ELECTRODERMAL WAVEFORM 7-Position Scale EDA tracing is generally most responsive. Ratio of response method is used to assign values. Unit of measurement is generally vertical chart division at 1/4 vertical grid setting. Assigned values are based on ratio scale: RATIO SCORE 4:1 +/- 3 3:1 +/- 2 2:1 +/- 1 1:1 0 85

ELECTRODERMAL WAVEFORM 7-Position Scale Exception to Ratio Scoring Method: Bigger is Better Principle for initial +/-1 After 2:1 ratio is reached, bigger is better principle no longer applies 86

ELECTRODERMAL WAVEFORM 7-Position Scale Complexity and duration may be assigned value of +/-1 only Once 2:1 ratio is reached, complexity and duration are not considered 87

Score EDA at C1 Against R1 & R2 2:1 Ratio 3:1 Ratio Score = -1 Score = -2 88

ELECTRODERMAL WAVEFORM Score EDA at C1 Against R1 & R2 4:1 Ratio B/B Score = -3 Score = -1 89

CARDIOVASCULAR SYSTEM 90

CARDIOVASCULAR WAVEFORM 7-Position Scale Baseline arousal (phasic response) is the only primary diagnostic feature Magnitude of comparative response is utilized to assign values 91

CARDIOVASCULAR WAVEFORM 7-Position Scale For a value of +/-1, response must be visually larger but less than twice the degree of baseline arousal than its comparative response. For +/-2, response must have twice but less than three times the degree of baseline arousal than its comparative response 92

CARDIOVASCULAR WAVEFORM 7-Position Scale For +/-3, response must have three times the degree of baseline arousal or more than its comparative response. 93

Cardiovascular Tracing - Score C1 Against R1 & R2 Score = -2 Score = -3 94

CARDIOVASCULAR WAVEFORM 7-Position Scale Comparative CV responses differentiated by less than one standard chart division are not assigned values higher than +/-1. 95

Cardiovascular Tracing - Response Differentiated By Less Than One Chart Division Score = -1 96

CARDIOVASCULAR WAVEFORM 7-Position Scale Other Considerations Secondary features of duration and decrease in rate may be assigned values of +/-1 only 97

QUESTIONS THANK YOU! 98