WW RSXF LED Floodlight Luminaire Catalog Number Notes Type Hit the Tab key or mouse over the page to see all interactive elements. Introduction Specifications EPA (ft @ ):.9 ft (.8 m ) W The new RSXF LED Flood family delivers maximum value by providing significant energy savings, long life and outstanding photometric performance at an affordable price. The RSXF delivers, to, lumens allowing it to replace W to W HID luminaires. Length: Width: Height: Weight (max): 8." (.9 cm). (. cm)." (. cm) Main Body. (9. cm ) Arm. lbs (. kg) L H The RSXF features an adjustable integral slip-fitter that allows the luminaire to be mounted on a -/8 OD tenon. Integral cover/wire box serves as an approved splice compartment allowing for fast, easy mounting and wiring without opening the electrical compartment. Ordering Information EXAMPLE: RSXF LED P K WFL MVOLT IS DDBXD RSXF LED Series Performance Package Color Temperature Distribution Voltage Mounting RSXF LED P P P P P P K K K K K K AWFD WFL MFL NFL SP NSP Area Wide Forward Wide Flood Medium Flood Narrow Flood Spot Narrow Spot MVOLT (V-V) HVOLT (V-8V) (use specific voltage for options as noted) 8 8 IS Adjustable slipfitter (fits -/8 OD tenon) Options Finish Shipped Installed HS House-side shield PE Photocontrol, button style, PEX Photocontrol external threaded, adjustable, PER, 8, 9 Seven-wire twist-lock receptacle only (no controls) DS Dual Switching CE Conduit entry / NPT (Qty ) SF Single fuse (,, ) DF Double fuse (8,, 8) SPDKV KV Surge pack (KV standard) FAO Field adjustable output DMG -V lead wires extended (no controls) Shipped Installed *Standalone Sensors Controls (factory default settings, see table page ) PIRS Motion/ambient sensor for 8- mounting heights,, PIRHS Motion/ambient sensor for - mounting heights,, *Networked Sensors/Controls NL TAIR nlight AIR generation, PIRHN Networked, Bi-Level motion/ambient sensor (for use with NLTAIR),,, DDBXD DBLXD DNAXD DWHXD DDBTXD DBLBXD DNATXD DWHGXD Dark Bronze Black Natural Aluminum White Textured Dark Bronze Textured Black Textured Natural Aluminum Textured White Shipped Separately (requires some field assembly) FV Full Visor ( around light aperture) UBV Upper/bottom visor *Note: Sensor coverage pattern is affected when luminaire is tilted. One Lithonia Way Conyers, Georgia Phone: 8.9.8 www.acuitybrands.com -8 Acuity Brands Lighting, Inc. All rights reserved. Lithonia RSXF Flood LED Rev. 9//8 Page of
Ordering Information Accessories Ordered and shipped separately. RSXFFV U Full visor (specify finish) RSXFUBV U Upper/bottom visor (specify finish) RCPIRS Remote control PIRS/PIRHS field programmer DLLF. JU Photocell - SSL twist-lock (-V) DLLF. CUL JU Photocell - SSL twist-lock (V) DLL8F. CUL JU Photocell -SSL twist-lock (8V) DSHORT SBK U Shorting cap NOTES MVOLT driver operates on any line voltage from -V (/ Hz). HVOLT driver operates on any line voltage from -8V (/ Hz). Single fuse (SF) requires V, V or V. Double fuse (DF) requires 8V, V or 8V. IS maximum tilt is 9 above horizontal. Requires MOVLT or V. Requires V, 8V, V, V or V. Not available in combination with other light sensing control options (following options cannot be combined: PE, PEX, PER, PIRS, PIRHS, PIRHN). 8 Twistlock photocell ordered and shipped as a separate line item from Acuity Brands Controls. See accessories. Shorting Cap included. Dimming leads capped for future use. 9 For units with option PER, the mounting must be restricted to +/- from horizontal aim per ANSI C.-. Requires () separately switched circuits. See Outdoor Control Technical Guide for details. Provides / fixture operation via () independent drivers. Not available with PE, PEX, PER, PIRS, PIRSH or PIRHN. Must be ordered with PIRHN. Must be ordered with NLTAIR. For additional information on PIRHN visit here. Requires luminaire to be specified with PER option. Ordered and shipped as a separate line item from Acuity Brands Controls. Two or more of the following options cannot be combined including DMG, PER, FAO, PIRS, PIRHS and PIRHN. Requires MVOLT or HVOLT. External Shields UBV Visor - Mounted UBV Visor - Bottom Mounted Full Visor - Pole/Mounting Informatiion Accessories including bullhorns, cross arms and other adpaters are available under the accessories tab at Lithonia s Outdoor Poles and Arms product page. Click here to visit Accessories. RSXF - Luminaire EPA *Includes luminaire and integral mounting arm. Other tenons, arms, brackets or other accessories are not included in this EPA data. Fixture Quantity & Mounting Configuration EPA (ft ) Single @ 9 @ 8 @ 9 @ @ 9 by by by Mounting Type IS - Integral Slipfitter Tilt.9...8..9.......8..8..9.............8.....9..8.....9....9...8..8.8....8.....8....9....89.. 8.8.8...89. 8.. 8.. 8.....9..9.9.9 9.8.9. 8.8 8..88... One Lithonia Way Conyers, Georgia Phone: 8.9.8 www.acuitybrands.com -8 Acuity Brands Lighting, Inc. All rights reserved. Lithonia RSXF Flood LED Rev. 9//8 Page of
Photometric Diagrams To see complete photometric reports or download.ies files for this product, visit Lithonia Lighting s RSX Area homepage. Isofootcandle plots for the RSXF LED P K. Distances are in units of mounting height ( ). LEGEND. fc. fc. fc Luminaires tilted at - - - - - - - WFL - - - - - - - MFL - - - - - - - AWFD Luminaires tilted at - - - - - - - NFL - - - - - - - SP - - - - - - - NSP One Lithonia Way Conyers, Georgia Phone: 8.9.8 www.acuitybrands.com -8 Acuity Brands Lighting, Inc. All rights reserved. Lithonia RSXF Flood LED Rev. 9//8 Page of
Performance Data Lumen Ambient Temperature (LAT) Multipliers Use these factors to determine relative lumen output for average ambient temperatures from - C (- F). Ambient Ambient Lumen Multiplier C F. C F. C F. C 9 F. C 8 F. C F. C 8 F.99 C 9 F.98 C F.9 C F.9 C F.9 Electrical Load Current (A) Performance Package System Watts (W) V 8V V V V 8V P W.9..... P W.9..... P W...... P 8W..9.8.8..8 P W...8... P W....88.. Projected LED Lumen Maintenance Operating Hours,,, Lumen Maintenance Factor >.9 >.9 >.9 Values calculated according to IESNA TM-- methodology and valid up to C. Lumen Output Lumen values are from photometric tests performed in accordance with IESNA LM-9-8. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts. Contact factory for performance data on any configurations not shown here. Performance Package P P P P P P System Watts W W W 8W W W Distribution. Type Field Angle Beam Angle K (K, CRI) K (K, CRI) K (K, CRI) H V H V Lumens LPW Max CD Lumens LPW Max CD Lumens LPW Max CD AWFD 9 9 9,,9, 8,9, 8,9 WFL 9 8 9,,,,8,,8 MFL 9 9 9,8 9,8,8,9,8,9 NFL 8 9 9,9,9,9,8,9,8 SP 8 8 9, 9,8,,,, NSP 9 9,8 9,,,,, AWFD 9 9,9,,8 9,8,8 9,8 WFL 9 8,88,9,8,98,8,98 MFL 9 9, 9,,9,9,9,9 NFL 8 9,88,,,8,,8 SP 8 8,,89,88,8,88,8 NSP 9,,, 8,, 8, AWFD 9 9 9, 9,9,88,,88, WFL 9 8 8,,98, 9 8,, 9 8, MFL 9 9 9, 8,8, 9,8, 9,8 NFL 8 9 8, 8,,9,,9, SP 8 8 8,,88 9,9,9 9,9,9 NSP 9 8, 9,,8 8,9,8 8,9 AWFD 9 9,9 8,89,,,, WFL 9 8,9 9,8,,9,,9 MFL 9 9,,,9 8,8,9 8,8 NFL 8 9,,,89,8,89,8 SP 8 8,98 9,88,9 9,,9 9, NSP 9, 9,8, 9,, 9, AWFD 9 9, 8,,8 8,9,8 8,9 WFL 9 8,,,,,, MFL 9 9,,8,,99,,99 NFL 8 9,8,,8 8 9,,8 8 9, SP 8 8,9,,9 8,8,9 8,8 NSP 9,,8,8 9,9,8 9,9 AWFD 9 9,,8,,8,,8 WFL 9 8,,8 9,9, 9,9, MFL 9 9 8,,89,,8,,8 NFL 8 9,,99 9,9, 9,9, SP 8 8,8 8 8, 8,98 9 9, 8,98 9 9, NSP 9,8,8 9,9, 9,9, One Lithonia Way Conyers, Georgia Phone: 8.9.8 www.acuitybrands.com -8 Acuity Brands Lighting, Inc. All rights reserved. Lithonia RSXF Flood LED Rev. 9//8 Page of
Sensor Coverage Motion Sensor Default Settings (PIRS and PIRHS only) Option Dimmed State High Level Photocell Ramp-up Ramp-down (when triggered) Operation Dwell Time Time Time PIRS or PIRHS Approx. % Output % Output Enabled @ FC minutes seconds seconds PIRS Coverage Patterns ' ' ' ' ft ' ' ' ' ' ' ' ' ' ' ' ' 8 ' ' ' 9 ' ' ' ' ' ' 9 ' ' ' 8' ' PIRHS Coverage Pattern ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' PIRHN nlight Sensor Coverage Pattern nlight PIRHN FEATURES & SPECIFICATIONS INTENDED USE The RSX LED flood family is designed to provide a long-lasting, energy-efficient solution for the one-for-one replacement of existing metal halide or high pressure sodium lighting. The RSXF delivers, to, lumens and is ideal for replacing W to W HID pole-mounted luminaires in parking lots and other area lighting applications. CONSTRUCTION The RSX LED flood luminaire features a rugged die-cast aluminum main body that uses heatdissipating fins and flow-through venting to provide optimal thermal management that both enhances LED performance and extends component life. Integral adjustable slipfitter mounts on a /8 OD tenon. The adjustable slip fitter has an integral junction box for easy installation. The light engines and housing are sealed against moisture and environmental contaminants to IP. The low-profile design results in a low EPA, allowing pole optimization. All mountings are rated for a. G vibration load per ANSI C.. FINISH Exterior parts are protected by a zinc-infused Super Durable TGIC thermoset powder coat finish that provides superior resistance to corrosion and weathering. A tightly controlled multi-stage process ensures superior adhesion as well as a minimum finish thickness of mils. The result is a high-quality finish that is warrantied not to crack or peel. OPTICS Precision acrylic refractive lenses are engineered for superior application efficiency, distributing the light to where it is needed most. Available in short and wide pattern distributions including Wide Flood, Medium Flood, Narrow Flood, Spot, Narrow Spot and Area Wide/Forward. ELECTRICAL Light engine(s) configurations consist of high-efficacy LEDs mounted on metal-core circuit boards and aluminum heat sinks to maximize heat dissipation. Light engines are IP rated. LED lumen maintenance is >L9/, hours. CCT s of K, K and K (minimum CRI) are available. Class electronic drivers ensure system power factor >9% and THD <%. Easily serviceable kv surge protection device meets a minimum Category C Low operation (per ANSI/ IEEE C..). STANDARD CONTROLS The RSX LED flood luminaire has a wide assortment of control options. Dusk to dawn controls include MVOLT and V button-type photocells and NEMA twist-lock photocell receptacles. Integrated motion sensors with on-board photocells feature remote control sensor programing and are suitable for mounting heights up to feet. nlight AIR CONTROLS The RSX LED flood luminaire is also available with nlight AIR for the ultimate in wireless control. This powerful controls platform provides out-of-the-box basic motion sensing and photocontrol functionality and is suitable for mounting heights up to feet. Once commissioned using a smartphone and the easy-to-use CLAIRITY app, nlight AIR equipped luminaries can be grouped, resulting in motion sensor and photocell group response without the need for additional equipment. Scheduled dimming with motion sensor over-ride can be achieved when used with the nlight Eclypse. Additional information about nlight Air can be found here. INSTALLATION The integral IS mount offers an adjustable slipfitter that mounts on a /8 OD tenon. The adjustable slip fitter has an integral junction box and offers easy installation, wiring and distribution pattern aiming. IS adjustable slipfitter is not rated for tilting above 9 or mounting within feet of ground. Can be tilted up to 9 above horizontal. LISTINGS CSA Certified to meet U.S. and Canadian standards. Suitable for wet locations. DesignLights Consortium (DLC) Premium qualified product and DLC qualified product. Not all versions of this product may be DLC Premium qualified or DLC qualified. Please check the DLC Qualified Products List at www.designlights.org/qpl to confirm which versions are qualified. WARRANTY -year limited warranty. Complete warranty terms located at: www.acuitybrands.com/customerresources/terms_and_conditions.aspx Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at C. Specifications subject to change without notice. One Lithonia Way Conyers, Georgia Phone: 8.9.8 www.acuitybrands.com -8 Acuity Brands Lighting, Inc. All rights reserved. Lithonia RSXF Flood LED Rev. 9//8 Page of