FOR BIS USE ONLY. WC Document Doc: MHD 16 (0076) Draft Indian Standard Elastic Bandages Last Date for Comments: 30/8/2009

Similar documents
प ल प ज पन/DOCUMENT DESPATCH ADVICE र भ /Ref. प ड 22/( 11023) डबल PGD 22/( 11023) W

SOUTH AFRICAN NATIONAL STANDARD

EDICT ± OF GOVERNMENT

Indian Standard SPECIFICATION FOR USE IN FOUNDRIES. 1.1 This standard covers the requirements for chaplets for use in foundries.

SPECIFICATION FOR PAPER STATIONERY ITEMS FOR SCHOOLS ( First Revision of IS 5195)

TECHNICAL COMMITTEE: Measurement and Cost Analysis of Works for River Valley Projects Sectional Committee, WRD 23

BUREAU OF INDIAN STANDARDS. Draft Indian Standard TWO COMPONENTS HIGH BUILD EPOXY MICACIOUS IRON OXIDE (MIO) PIGMENTED INTERMEDIATE COAT SPECIFICATION

(PETROLEUM, COAL & RELATED PRODUCTS DEPTT.) स भ : प स ड 6 (10471) स

NAME OF THE COMMENTATOR/ORGANIZATION: Doc. No.: PG 20(1020) TITLE: Dimensions for relief grooves (second revision of IS 3428)

Household refrigerating appliances - Characteristics and test methods : Part 2 Performance requirements (Adoption of IEC )

For comments only

SCHEME OF TESTING AND INSPECTION FOR CERIFICATION OF TEXTILE-VEST, COTTON, PLAIN (SINGLE JERSEY) KNITTED ACCORDING TO IS 4964:2003 (Fourth Revision)

SPECIFICATION FOR HIGH STRENGTH STRUCTURAL BOLTS

Disclosure to Promote the Right To Information

ISO INTERNATIONAL STANDARD. Textiles Determination of fabric propensity to surface fuzzing and to pilling Part 1: Pilling box method

MANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARG, NEW DELHI

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE

Peel Adhesion of Pressure Sensitive Tape

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T

Disclosure to Promote the Right To Information

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

IMPREGNATED, COATED, COVERED OR LAMINATED TEXTILE FABRICS; TEXTILE ARTICLES OF A KIND SUITABLE FOR INDUSTRIAL USE

(First Revision of IS 2339) (Not to be reproduced without the permission of BIS or used as STANDARD)

APPENDIX 1 TO ANNEX I

3rd NATIONAL CONCLAVE ON STANDARDS FOR TECHNICAL TEXTILES PRESENTATION ON MEDICAL TEXTILES

(med filtad sula) 1. DESCRIPTION APPLICABLE DOCUMENTS PRODUCT REQUIREMENTS MANUFACTURING... 8

FOR READY MIXED PAINT, ALUMINIUM, BRUSHING, PRIMING, WATER RESISTANT, FOR WOODWORK

Draft Tanzania Standard. Textiles Specification for open mouth woven poly-sacks made from polypropylene tape- yarns

DRAFT EAST AFRICAN STANDARD

DRAFT UGANDA STANDARD

Lecture 4. Medical Textiles Total Consumption. cancer. Properties of Medical Textiles

DRAFT UGANDA STANDARD

MAN-MADE FILAMENTS; STRIP AND THE LIKE OF MAN-MADE TEXTILE MATERIALS

National Standard of the People s Republic of China. Conventional Moisture Regains of Textiles

Swabs. Dressings. Fixation. Compression Bandages. Complimentary Products

Machine Tools, Machine Tool Elements and Holding Devices Sectional Committee, PGD 35

Disclosure to Promote the Right To Information

CMD-II (Legal) Our Ref: CMD-II (Legal)/16: Oct 2014

भ रत य म नक य र BUREAU OF INDIAN STANDARDS

Woven interlinings and linings for apparel purposes Specification

Standard Test Method for Grading Spun Yarns for Appearance 1

Man-made staple fibres

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

Proposal for new standard. Determination of interface friction between painted parts. Orientation. p. 1 (15) Draft1, Revised

PROTECTO SILL WINDOW SEALING SYSTEM. Product. Scope. Appraisal No. 444 [2017]

Pre-printed PVC Cable Markers O-Type, K-type, Z-type, V-Type

Enriched by the valuable experience of more than 25 years, Dali is professional

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. FZ/T

National Standard of the People's Republic of China

Disclosure to Promote the Right To Information

COOPERATIVE PATENT CLASSIFICATION

THE KENYA POWER AND LIGHTING CO. LTD. SPECIFICATIONS for IMPULSE VOLTAGE TEST EQUIPMENT

Disclosure to Promote the Right To Information

DRAFT IN WIDE CIRCULATION DOCUMENT DESPATCH ADVICE MHR 15/ T TECHNICAL COMMITTEE: MHR 15 ADDRESSED TO:

tbs TDC3 (5614)P 3 Draft Tanzania Standard Textiles Towels Specifications TANZANIA BUREAU OF STANDARDS

DRAFT UGANDA STANDARD

MESP TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/ mm 2

SOUTH AFRICAN NATIONAL STANDARD

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

Sýnishorn. Leather Tests for colour fastness Colour fastness to migration into polymeric material

Type Approval JANUARY The electronic pdf version of this document found through is the officially binding version

Swabs. Cotton Balls. Absorbent Pads. Tapes. Dressings. Bandages. Orthopaedic underpadding. Bandage clips

Draft Copy Textiles High Tenacity Yarn of Nylon or other Poly-amides Specification (HS: ) Foreword High tenacity Nylon or other polyamides:

Disclosure to Promote the Right To Information

MESP TECHNICAL SPECIFICATION FOR FLEXIBLE DROPPER WIRE TIN-BEARING COPPER 7/7/ mm 2

DRAFT EAST AFRICAN STANDARD

Woven Steel Wire Fence Type-47. Under the state specification for fencing, ASTM A 116 is called out.

EDICT ± OF GOVERNMENT

Branch PLANT KHIMVOLOKNO JSC GRODNO AZOT

LESSON 15 TESTING OF TEXTILE FABRICS

BUREAU OF INDIAN STANDARDS. DRAFT FOR COMMENTS ONLY (Not to be reproduced without the permission of BIS or used as an Indian Standard)

MESP TECHNICAL SPECIFICATION FOR MURL JUMPER WIRE HARD-DRAWN COPPER 19/ mm 2

TECHNICAL SPECIFICATION FOR G.I. WIRE AND G.I. STAY WIRE

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE

Request for Public Comment on a Commercial Availability Request under the

Disclosure to Promote the Right To Information

CUSTOMS TARIFF - SCHEDULE. Chapter 59

DRAFT TANZANIA STANDARD. TBS/CDC-2(4970) P3- Carbolic Soap - Specification (Revision of TZS 221:1984)

Woven interlinings and linings for apparel purposes Specification

EDICT ± OF GOVERNMENT

J O I N T I N D U S T R Y S T A N D A R D. Requirements for Soldering Pastes J Standard 005A. December 2011

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

Australian/New Zealand Standard

TECHNICAL SPECIFICATION FOR G. I. WIRE (4MM)

Practical Information ORALITE Reflective Films of Class RA2, Grade B for Road Safety

Department of Textile & Leather

Ring crush of paperboard (flexible beam method) (REAFFIRMATION of Classical Method T 818 cm-07) (No changes from previous drafts)

JB/T Translated English of Chinese Standard: JB/T

ववषय म पक ड प म य प ब न य त रण प सम य जप प ववम ष टट ( आई एस प प रथम पक क षण )

Disclosure to Promote the Right To Information

ISO INTERNATIONAL STANDARD. Textiles Determination of fabric propensity to surface fuzzing and to pilling Part 2: Modified Martindale method

SPECIFICATION FOR SAFETY POLE SIGNS & ACCESSORIES

M is for Moto Joggers (FREE Capri length version)

Fire testing: Calibration of smoke opacity measuring systems

Part E04: Textiles Tests for colour fastness. Colour fastness to perspiration

MESP TECHNICAL SPECIFICATION FOR CATENARY WIRE HARD-DRAWN COPPER 37/ mm 2

Rebate of the duty on partially orientated yarn classifiable under tariff subheading used in the manufacture of textured nylon yarn

This document is a preview generated by EVS

TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES... 4

SVENSK STANDARD SS-ISO 2559:2004

Transcription:

FOR BIS USE ONLY WC Document Doc: MHD 16 (0076) Draft Indian Standard Elastic Bandages Last Date for Comments: 30/8/2009 0. FOREWORD The draft Indian Standard has been prepared based on information s available with manufacturing capability of Indian Industries. An elastic bandage is one continuous strip without joints, of woven/knitted material stretches along its intended to provide support and immobilize dressings covering the wounds besides the function of compression and support for orthopedic purposes. For the purpose of deciding whether a particular requirement of this standard is compiled with, the final value, observed as calculated, expressing the result of a test, shall be rounded off in accordance with IS 2: 1960 Rules for rounding off the numerical values (revised). The number of significant places retained in the rounded off value should be the same as that of the specified value of this standard. 1. Scope This proposed draft Indian Standard covers the dimensions and other requirement for Elastic bandages 2 References 2.1 The following Indian Standard is necessary adjuncts to this standard IS No 1889(Part 1):1976 Title Method For quantitative chemical analysis of binary mixtures of regenerated cellulose fibers and cotton 3. Definitions 3.1 Elastic Bandages An elastic bandage is intended to provide support and immobilize dressings covering the wounds besides the function of compression and support for orthopedic purposes.

4 Types: Elastic bandages can be classified based on type of yarn with their method of manufacturer 5. Dimensions & tolerances: A- Woven cellulosic yarn bandage B- Knitted cellulosic yarn bandage C- Woven non cellulosic yarn bandage D- Knitted non cellulosic yarn bandage E- Combination of both cellulosic yarn/non cellulosic yarns woven knitted F- Combination of both cellulosic yarn/non cellulosic yarns woven knitted Note: E & F type are BIS proposal member may give their opinion Description width Tolerance Stretched length Elastic 2 to 4 cm ± 0.2cm 2.0 to 4.0 m Bandages 5 to 12 cm ± 0.5cm 4.0 to10.0 m Tolerance ± 20 cm ± 40 cm 6. Material 6.1 Elastic bandages shall be cellulosic/ non-cellulosic yarn or combination of both yarn with following composition 6.1.1 Hydrophilic/cellulosic fiber content, minimum 35% [see IS1889 (Part 1):1976] 6.2 Filament yarns made from Partially Oriented Yarn (POY) of Polyester, Polyamide, Polypropylene or equivalent material. 6.3 Consist of a core made of high stretch spandex, lycra, polyurethane, rubber or similar Material and covered/wrapped with synthetic filament yarn or grey/bleached/dyed cotton and/or Viscose/rayon. 7 Requirements 7.1 Weight The weight of the elastic bandage shall be 25 to 170 g/sq m 7.1.1 The weight of elastic bandage determined by weighing the whole bandage divided by the stretched surface area per width gives the weight per unit area.

7.2 Stretch Length and Extensibility- The extensibility of Elastic Bandage shall be 65 to 220 percent when tested as described in Appendix A 7.3 Regain- The regain of the test bandage shall be not less than 70% when tested as described in Appendix B 8. Manufacture, Workmanship and Finish 8.1. Elastic bandages shall be in Woven/knitted bandages containing cellulosic, Noncellulosic yarns or a combination of both with non-fraying closed selvedges/edges and or grey/while/coloured shade. 8.2 Finish 8.2.1 The use of optical brightening agents is prohibited. Under UV lamp no fluorescence shall be observed except for a few brightly illuminated individual fibers. 9. Tests 9.1. Testing of Elastic bandage shall be carried out at 65±5 relative humidity and temperature 25± C 9.2 Test for Width: The portion between and including the fast edges of the un stretched bandage 9.3 Test for Diameter: The distance as measured at the outer circumference while holding the bandage but not pressing the bandage. 10 Packing and Marking 10.1 Packing- The bandage shall be rolled and packed suitably to prevent contamination from dust. 10.2 Marking 10.2.1 The package shall be marked with the following information: a) Name and trade-mark of the manufacturer b) Colour, if any c) Width and stretched length; and d) Batch number 10.2.2. Package may also be marked with the ISI Certification Mark.

Note_ The use of ISI Certification Mark is governed by the provisions of the Indian Standards Institution (Certification Mark) Act and the Rules and Regulations made there under. The ISI Mark on products covered by an Indian Standard conveys the assurance that they have been produced to comply with the requirements of that standard under a well-defined system of inspection, testing and quality control which is devised and supervised by ISI and operated by the producer. ISI marked products are also continuously checked by ISI for conformity to that standard as a further safeguard. Details of conditions, under which a license for the use of ISI Certification Mark may be granted to manufacturer or processors, may be obtained from the Indian Standard Institution.

APPENDIX A (Clause 7.2) Metohd for mesuring of stretched length and extensibility of elastic bandage A-1 TEST SPECIMEN A-1.1 For the purpose of this test, all rolls in the test sample constitute the test specimen. A-2 Apparatus A-2.1 Stretch testing table of marked length 6 meter length with fixed clamp A at left end and moving clamp B at right end. The table has mechanical and pneumatic arrangement for the loading and un-loading the weights (see Figure 1). The table is attached with a fixed measuring tape arrangement. A-2.2 Standard weight up to 25 kg in denominations of 1 kg, 2 kg and 5 kg whichever applicable. A-3 Procedure A-3.1 Unwind the bandage on the stretch table and measure its un-stretched length L1 immediately. Mark 5 cm on both ends and clamp (A and B) the bandage at both ends X1 and X 2. Connect the loading pan C weighing 1 kg to the moving clamp. Now apply load of 1 kg for each cm (including pan weight) of bandage width. Keep it extended condition for about 30 seconds. Measure the distance between the marks and record stretched length L2. Remove/release the load mechanically or by pneumatic arrangement. Add correction factor (CF) to stretched length L2. A-3.1.1 For bandage of stretched length above 5 meters measure the un-stretched length. Mark the centre point by dividing the unstretched length by two. Check the stretched length for the first part and second part separately by the same method. A-3.2 Calculate the correction factor and extensibility Correction factor in cm = 10 + (standard ext % of bandage)/10 Extensibility = L2-L1 X100. L1 Note: the CF is to be added once only

APPENDIX B (Clause 7.3) METHOD FOR MEASURING OF REGAIN B-1 Test Specimen B-1.1 For the purpose of this test all rolls in the test sample constitute the test specimen. B-2 Apparatus B-2.1 Stretch testing table of marked length 6 meter length with fixed clamp A at left end and moving clamp B at right end. The table has mechanical and pneumatic arrangement for the loading and un-loading the weights (see figure 2). The table is attached with a fixed measuring tape arrangement. B-2.1.1 Standard weight up to 25 kg in denominations of 1kg, 2kg and 5 kg whichever applicable. B-3 Procedures B.3.1 Measure the un-stretched length and marked 5 cm at the beginning and at the end of the bandage. In order to determine the regain, i.e. the remaining length and recovered length must be determined. Make a second mark at the beginning of the bandage at a distance of 10 cm from the first mark. Measure the stretched length as per test procedure. Wait for 2 minutes and in this time the bandage must laying in zig-zag relaxed position (length of about 30 cm). To get the remaining length, measure the length of the marks at the beginning at/ and at the end of the bandage. Add the small part between the first and the second mark. This will give the remaining length. A-3.2 Calculate the regain in percentage Regain in % = Stretched length remaining length X 100 Stretched length unstretched length

W C DOCUMENT DOCUMENT DESPATCH ADVICE Ref Date MHD16//T-DOC(0076) 01-07-2009 TECHNICAL COMMITTEE: Surgical Dressings and Disposables products Sectional Committee MHD 16 ADDRESSED TO: All members of 1 Surgical Dressings and Disposables Products Sectional Committee MHD 16 2 Medical Laboratory Instruments Sectional Committee MHD 10 3. MHDC 4. Medical colleges Dear Madam(s)/Sir(s), Please find enclosed the following documents: DOC NO: MHD 16 (0076) TITLE Draft Indian Standard on Elastic Bandage Kindly examine the draft Indian Standards and forward your views/comments if any on the above WC DOCUMENT in the enclosed Performa. These are likely to be discussed during the meeting likely to be held in the month of September 2009 at Manak Bhavan, BIS, New Delhi. Last date for comments: 30-08-09 This document is available on BIS web site www.bis. org.in. Thanking you, Yours faithfully, Encl: As Above (Rahul Kumar) Scientist F & Head MHD E-Mail prembattoo.bis@bis.org.

FORMAT FOR SENDING COMMENTS ON BIS DOCUMENTS (Please use A4 size sheet of paper only and type within fields indicated. Comments on each clauses/sub-clauses/table/fig. etc be started on a fresh box. Information in Column 5 should include reasons for the comments and suggestions for modified wording of the clauses when the existing text is found not acceptable. Adherence to this format facilitates Secretariat s work) DOC NO: MHD 16 (0076) TITLE Draft Indian Standard on Elastic Bandage LAST DATE OF COMMENTS: 30 08 2009 NAME OF THE COMMENTATOR/ORGANIZATION: Sl. Clause/Sub-lause Comments No. para/table/fig. Commentator Orgn (Abbreviation) Justification & Proposed change