Valves, Actuators, Accessories. N Series Solenoid Valve

Similar documents
ü ( Explosion Protection

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

FOR RELIABLY MEASURING +

Technical Data. General specifications. Rated operating distance s n 3 mm

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

KFS. Flap-type flow meter. Design and range of application

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009

Single-Channel Safety Barriers Series 9001

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

The EVI 30/8 coils can be equipped with the suitable plunger guide tube (see S8 - S9 Catalogue).

Ex-control switch Typ 294 without and Typ 295 with measuring instrument

SOLENOIDS, COILS & ACCESSORIES Product Index

Two-channel safety barriers Series 9002

Rod probe With coaxial tube reference probe

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Two-channel safety barriers Series 9002

SALES SERVICE +358 (0)

Resistance thermometers for process technology

Electrical Temperature Measurement

Positive Displacement Flow sensors

TIDALFLUX 2300 F Technical Datasheet

Positioner with HART Communication Type 3780

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.

Explosion proof rotary actuator - On/Off or programmable regulating actuator

Field indicator for current loops with HART communication Models DIH50, DIH52

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Level Limit Switch nivotester FTL 370, FTL 372

... for hydraulic and general applications in hazardous areas

2-way pilot operated solenoid valves for water, hot water and steam

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

2/2-Way Solenoid Control Valve

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

IP26 Series Current to Pneumatic Converter

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Limit switch attachments DAPZ

OPTIWAVE 1010 Technical Datasheet

Target disk flowmeter for liquids and gases

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Coriolis Massflowmeter

Field indicator for current loops with HART communication Models DIH50, DIH52

OPTIFLUX 5000 Technical Datasheet

Coriolis Massflowmeter

Inductive sensor slot-type SI2-K08-AP7

Local control stations for Zone 1 and Zone 21. Features. Description

Remote Switching Unit nivotester FTL 320

SITRANS T measuring instruments for temperature

Metal tube variable area flowmeters for gases, liquids and steam

Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx.

Coil. Coil L 12 VDC 135 C 18 W 7.7 Ω M M 24 VDC 135 C 18 W 31 Ω M AMP Junior (AJ variant) Coil

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NAMUR style, 1/4-1/2

Resistance thermometer Model TR30, compact design

Base Mounted Plug-in Unit

TMU. Coriolis Mass Flow Meter. for liquids and gas

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

All TXI7850 products are ROHS compliant.

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

Resistance thermometer Model TR30, compact design

IFC 100 Technical Datasheet

How to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style

Advantages. Applications

OEM radar transmitter, for aggressive media level measurement

SINEAX TI 807 Passive DC signal isolator

Resistance Thermometers Model Series TR7X0, Sheathed Design

MBC /602(L) MBC /602(L) MBC /602(L)

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

TQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES

Relative and absolute pressure transmitter type 528

Level Switch Catalogue

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Isolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones

Echotel Model 910 Ultrasonic Level Switch

Preset counters, electronic

Installation guide 971 SmartRadar LTi

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Remote I/O. 74 Remote I/O. Remote I/O System

Technical Information Nivector FTC968, FTC968Z

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

BATCHFLUX 5500 C Technical Datasheet

OPTIFLUX 5000 Technical Datasheet

TQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES

Digital I/O Coupler (4-wire) Series 9413/21

FAS 10 mm PICOSOL Direct acting solenoid valve

Density meter DWF. Device description. Device description DWF Page 1 of 22

Signal Beacon - LED Series 6162

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

FBCon. Contents. FBCon. FBCon H.1. Introduction H.2 PROFIBUS-DP H.5 PROFIBUS-PA H.8 PROFIBUS-PA ATEX H.26. Fieldbus Foundation H.33. FBCon DK6 H.

Ultrasonic level measuring device, non-contact

Directional valves Coils Series CO1. Brochure

SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Directional valves Electrically operated Series 563, 565, 567. Brochure

INSTALLATION AND OPERATION MANUAL

Transcription:

Valves, Actuators, Accessories N eries olenoid Valve

Technical Data Function Manual override Design Mounting Mounting position Material specifications Media Fluid temperature Electrical parts Voltage Voltage tolerance Applications 3 or 5port directional valves for the control of single or double acting pneumatic actuators The interface design corresponds to the NAMUR standard and the VDI/VDE 3845 recommendations of the actuator industry permitting a compact design of the actuator/valve unit. 3/2, 5/2 and 5/3 solenoid and air operated valves. Locking manual override standard on all solenoid operated versions. Pilot operated spool valve with combined pneumatic and spring return. For direct mounting on NAMUR interface. Any position. Aluminium body. tainless steel is available. Dry or lubricated air. Min. 32 F (0 C) Max. 122 F (+ 50 C) ee information of coils. H HAN AN 24 VDC, 48 VDC, 110 AC, 220 AC ± 10% of nominal Working Principle B A A R P R P R NAMUR Interfaces T 1/4 1/2 D1 1/2 D1 in (mm) 1.26 (32) 1.77 (45) D2 D2 in (mm) 0.95 (24) 1.58 () T M T 1/4 M mm M5 M6 H 2W5 AN 2W3 2

N eries olenoid Valve olenoid Coil Width: 22 mm Connection Type: Industry Form Moulding Material: Thermoset Resin 11 M 3; 5 depth 29.5 15 6.3 ø9 22 8.5 6.8 28.8 HA AN 10 ø8 11 General Data Voltage tolerance Ambient temperature Relative duty cycle Insulation class of insulating materials according to DIN VDE 0580 Degree of protection with connector according to EN 60529 Imprint (customer imprint - special version) Technical Data Voltage[V] 12DC 24DC 48DC 110AC 220AV Frequency[Hz] - - - 50/60 50/60-10% ~+10% -20 C ~+50 C 100% F IP 65 / IP 67* Nass Magnet Output 4.6W 3.0W T.HAN TH N 2.7W 5.7/4.6VA 8.5/6.9VA 3

Valves, Actuators, Accessories olenoid Coil ystem 8 ATEX Widths : 22 mm Ex II 2G EEx m II T_/IEC Ex m II T_ Ex II 2D IP 65 T_ C/ IP65 DIP A21 T_ C Protection by Encapsulation Connection Type: Cable H05VV-F 3G1 Cable H05VV-F 3G1 standard length 3m HAN 50 29.5 ø9 22 55 ø8 11 EC-Type Examination Certificate PTB 00 ATEX 2001X / IECEx PTB 05.0006 General Data Voltage tolerance Ambient temperature Relative duty cycle Insulation class of insulating materials according to DIN VDE0580 Degree of protection with connector to EN 60529 Moulding material Cable length(other cable lengths on request) Technical Data Width 22mm 22mm Voltage[V] 24DC 220AC -10% ~+10% -20 C ~+50 C 100% F IP 65 Thermoplastoc 3 m T THA T.H Frequency[Hz] - 50/60 Output 3.0W 5.1VA Temperature Class T4 T4 4

N eries olenoid Valve olenoid Coil ystem 8 ATEX ø8 pecial Version: ystem 8 Ex CA/FM Width : 36 mm Ex m II T4 + Division 1 31 ø9 66 43 18 AN 36 ø24.6 thread connection 1/2-NPT standard length 24" Connection Type : Flying Leads, Thread 1/2-NPT EC-Type Examination Certificate CA 202633 Hazardous Locations Ex m II T4 and division 1 - Class I, Group A, B, C and D - Class II, Group E, F and G - Class III Approved in compliance with CAN/ CA-E79-0-95 and CAN/ CA-E79-18-95 for CA, according to ANI/ IA-12.00.01-1999 and ANI/ IA-12.23.01-1998 for FM. General Data Voltage tolerance Ambient temperature Relative duty cycle Insulation class of insulating materials according to DIN VDE0580 Degree of protection with connector to EN 60529 Moulding material Cable length(other cable lengths on request) Technical Data Voltage[V] 24DC 220AC Frequency[Hz] - 50 Output 4.6W 7.7VA -10% ~+10% -20 C ~+60 C 100% H IP 65 Thermoplastoc 24Inch/0.6 m T. HAN Thread Connection Temperature Class tainless teel T4 tainless teel T4 5

Valves, Actuators, Accessories Dimension 2W312-10- 21.0 18.0 2W522-10- 36.0 66.9 84.9 3-G1/8 5-G1/8 25.0 15.0 66.5 8.0 35.0 66.5 3 3 10.5 T35.0 2-Ø3.3 74.9 111.5 1.8 H31.0 12.5 33.0 HA13 13.5 5A3 36.0 17.0 H75.9 18.0 H65.9 38.0 17.0 2-Ø3.2 T35.0T H33.0 2-Ø3.2 2W512-10- 36.0 66.9 5-G1/8 31.5 3W522-10- 84.9 5-G1/8 66.5 31.5AN 3 66.5 3 6.5 116.5 10.5 35.0.3 AN3 T.HA TH22H1H AN T.H TH HA A9A AN 0 10.5 35.0 21.5 A 74.9 188.8 18.0 22.5 75.9 18.0 17.0 17.0 38.0 12.5 2-Ø3.2 38.0 65.9 2-Ø3.2 If you enquire any further information, please do not hesitate to contact us. 6

N eries olenoid Valve Dimension 94.4 2W312-10 2W512-10 20.5 30.0 17.5 10.5.0 119.4 T. 32.5 TH15.0 35.0 HA75 A45. 17.5 45.0 2W522-10 3W522-10 45.0 71.9 5-G1/4 T.HAN THAN.0 6.5 T8 188.8 83.4 H.4 94.4 4 HA45 71.9 45.0 5-G1/4 5-G1/4 6.5.0.0 If you enquire any further information, please do not hesitate to contact us. 6.5 28.0 8 134.5 T.HA 0T THAN HAN 207.8 29.0 83.4 15.0.4 7

Valves, Actuators, Accessories Dimension 2W311-10 2W511-10 134.5 6 32.0.0 ØX1.4 2W521-10 3W521-10 134.5 32.0 ØX1.4.0.0 32.5 6 22.5 H45.0 10.0 0 AN134.5 134.5 32.0.0 134.5 ØX1.4 N0X1.4 T.HAN H6H If you enquire any further information, please do not hesitate to contact us. 32.0 ØX1.4 NX1.4 T.HA.0AN N.0.0 NN 32.5 45.0 17.5 45.0 10.0 8

N eries olenoid Valve Dimension 25.5 31.5 2W312-15-L 34.0 2W522-15-L 15.5 51 Ø4.3 73.9 73.9 11.5 137 T H2 Ø4.3 41.5 2 2W512-15-L 57.0A63.0 T.HAN TH 27 34.0 3W522-15-L 5-G1/2 25.5 73.9 73.9 7.5 28.0 43.0 167.9 36.0 39.0 4.0 72.0 21.0 110.9 27 34.0 5-G1/2 63.0 79.4 T96.9 7.5 28.0 221.8 36.0 92.9 4.0 72.0 74.9 N 110.9 10.9 79.4 63.0 96.9 28.0 221.8 92.9 36.0 74.9 72.0 5-G1/2 27 34.0 If you enquire any further information, please do not hesitate to contact us. 7.5 TH74.9HHA 6.0 T.HA TH HAN 4.0 9

Valves, Actuators, Accessories How to Order UNIT 1 2 3 4 5 6 7 8 CONTENT Control mode tandards Coil Type Connection Body Power Explosive-proofp CODE None 2W5 1 1 10 None AC 220 None EXAMPLE olenoid 2 way 5 Ports ingle NAMUR 1/4 Middle AC 220V None olenoid 2W3 2 way 3 Ports 1 NAMUR mall None A Air 2W5 2 way 5 Ports 2 PIPE None Middle EExm II T4 3W5 3 way 5 Ports L Large EExm II T5 NNone EExia II T6 08 1/8 1 ingle coil 10 1/4 ANall DC 24V 2 Double coils 15 1/2 DC48V HA1/8 AC 24V Other Brands 15A TH HAN LAN N THcoil AC 110V AC 220V Product code 2W511-10-AC220 ACO MC FETO PARKER NOGREN BURKERT 10