Non-Contact Ultrasound Characterization of Paper Substrates

Similar documents
Resolution Enhancement and Frequency Compounding Techniques in Ultrasound.

COMPUTER PHANTOMS FOR SIMULATING ULTRASOUND B-MODE AND CFM IMAGES

ULTRASONIC IMAGING of COPPER MATERIAL USING HARMONIC COMPONENTS

Ultrasound Beamforming and Image Formation. Jeremy J. Dahl

MODELING AND EVALUATION OF DISTINCT ALTERNATIVE DESIGNS FOR WIDE-BAND AIR-COUPLED PIEZOELECTRIC TRANSDUCERS

Proceedings of Meetings on Acoustics

Real Time Deconvolution of In-Vivo Ultrasound Images

Theory and Applications of Frequency Domain Laser Ultrasonics

ULTRASONIC GUIDED WAVES FOR AGING WIRE INSULATION ASSESSMENT

2. Pulsed Acoustic Microscopy and Picosecond Ultrasonics

LASER GENERATION AND DETECTION OF SURFACE ACOUSTIC WAVES

Acoustic Holographic Imaging by Scanning Point Contact Excitation and Detection in Piezoelectric Materials

ECHO-CANCELLATION IN A SINGLE-TRANSDUCER ULTRASONIC IMAGING SYSTEM

Time Reversal FEM Modelling in Thin Aluminium Plates for Defects Detection

ULTRASONIC GUIDED WAVE ANNULAR ARRAY TRANSDUCERS FOR STRUCTURAL HEALTH MONITORING

Ultrasonic Air-Coupled Non-Destructive Testing of Aerospace Components

EFFECT OF SURFACE COATINGS ON GENERATION OF LASER BASED ULTRASOUND

Measurement of phase velocity dispersion curves and group velocities in a plate using leaky Lamb waves

Air Coupled Ultrasonic Inspection of Steel Rubber Interface

EE 422G - Signals and Systems Laboratory

Performance Measurements of SLAC's X-band. High-Power Pulse Compression System (SLED-II)

MEASUREMENT OF RAYLEIGH WAVE ATTENUATION IN GRANITE USING

Liquid sensor probe using reflecting SH-SAW delay line

CHAPTER 6 SIGNAL PROCESSING TECHNIQUES TO IMPROVE PRECISION OF SPECTRAL FIT ALGORITHM

ASSESSMENT OF WALL-THINNING IN CARBON STEEL PIPE BY USING LASER-GENERATED GUIDED WAVE

Manual UT vs PIMS (Permanently installed monitoring sensors)

Linear arrays used in ultrasonic evaluation

DEVELOPMENT OF A 50MHZ FABRY-PEROT TYPE FIBRE-OPTIC HYDROPHONE FOR THE CHARACTERISATION OF MEDICAL ULTRASOUND FIELDS.

Ultrasound-modulated optical tomography of absorbing objects buried in dense tissue-simulating turbid media

AN ACTIVELY-STABILIZED FIBER-OPTIC INTERFEROMETER FOR

Selective Excitation of Lamb Wave Modes in Thin Aluminium Plates using Bonded Piezoceramics: Fem Modelling and Measurements

Transmission- and side-detection configurations in ultrasound-modulated optical tomography of thick biological tissues

COUPLED SECTORIAL LOOP ANTENNA (CSLA) FOR ULTRA-WIDEBAND APPLICATIONS *

Characterization of Silicon-based Ultrasonic Nozzles

A miniature all-optical photoacoustic imaging probe

A STUDY ON NON-CONTACT ULTRASONIC TECHNIQUE FOR ON-LINE INSPECTION OF CFRP

AN AUTOMATED ALGORITHM FOR SIMULTANEOUSLY DETERMINING ULTRASONIC VELOCITY AND ATTENUATION

MEASUREMENT OF SURFACE ACOUSTIC WAVE USING AIR COUPLED TRANSDUCER AND LASER DOPPLER VIBROMETER

Measurement Of The Magnitude And Direction Of The Electric Field Of A Mobile Phone In The Near Field

EENG473 Mobile Communications Module 3 : Week # (12) Mobile Radio Propagation: Small-Scale Path Loss

The Physics of Echo. The Physics of Echo. The Physics of Echo Is there pericardial calcification? 9/30/13

Equipment for Attenuation and velocity of ultrasound in solid state materials (transmission), experimental set-up

CONTACT LASER ULTRASONIC EVALUATION OF CONSTRUCTION MATERIALS

A NEW APPROACH FOR THE ANALYSIS OF IMPACT-ECHO DATA

Optical coherence tomography

Multi-spectral acoustical imaging

Ultrasonic Testing using a unipolar pulse

Ultrasonic Transmission Characteristics of Continuous Casting Slab for Medium Carbon Steel

Attenuation and velocity of ultrasound in solid state materials (transmission)

THE MEASUREMENT AND ANALYSIS OF ACOUSTIC NOISE AS A RANDOM VARIABLE. Mechanical and Aerospace Missouri-Columbia 65203

Proceedings of Meetings on Acoustics

Piezoelectric Fiber Composite Ultrasonic Transducers for Guided Wave Structural Health Monitoring

NEW LASER ULTRASONIC INTERFEROMETER FOR INDUSTRIAL APPLICATIONS B.Pouet and S.Breugnot Bossa Nova Technologies; Venice, CA, USA

Propagation Channels. Chapter Path Loss

Supplementary Figure 1. GO thin film thickness characterization. The thickness of the prepared GO thin

BEAM DISTORTION IN DOPPLER ULTRASOUND FLOW TEST RIGS: MEASUREMENT USING A STRING PHANTOM

Nuove tecnologie per ecografia ad ultrasuoni: da 2D a 4D

MEAN GRAIN SIZE ESTIMATION FOR COPPER-ALLOY SAMPLES BASED ON ATTENUATION COEFFICIENT ESTIMATES

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

Simulation of Ultrasonic Testing of Rail Wheel Face using Phased Array and DDF technique

The Hong Kong University of Science and Technology Final Year Project presentation 2007

Broadband Temporal Coherence Results From the June 2003 Panama City Coherence Experiments

Ultrasonics. Introduction

High contrast air-coupled acoustic imaging with zero group velocity Lamb modes

FPGA-BASED CONTROL SYSTEM OF AN ULTRASONIC PHASED ARRAY

Parameter Estimation Techniques for Ultrasound Phase Reconstruction. Fatemeh Vakhshiteh Sept. 16, 2010

Timothy A. Bigelow Iowa State University,

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

C. Edwards, A. AI-Kassim* and S.B. Palmer Department of Physics University of Warwick, UK

Passive Polymer. Figure 1 (a) and (b). Diagram of a 1-3 composite (left) and a 2-2 composite (right).

Ginzton Laboratory, W. W. Hansen Laboratories of Physics Stanford University, Stanford, CA 94305

G. Hughes Department of Mechanical Engineering University College London Torrington Place London, WClE 7JE, United Kingdom

Non-Destructive Method Based on Rayleigh-Like Waves to Detect Corrosion Thinning on Non- Accessible Areas

Proceedings of Meetings on Acoustics

CRITICAL COMPARISON OF CONTACT AND NON-CONTACT ULTRASOUND: Characterization of Transducers and Ultrasound Systems for NDE & Sensing Applications

Ihor TROTS, Andrzej NOWICKI, Marcin LEWANDOWSKI

FATIGUE CRACK DETECTION IN METALLIC MEMBERS USING SPECTRAL

MATERIALS CHARACTERIZATION USING LASER ULTRASONIC GUIDED WAVES

ULTRASONIC SIGNAL CHARACTERIZATIONS OF FLAT-BOTTOM HOLES IN

Sea Surface Backscatter Distortions of Scanning Radar Altimeter Ocean Wave Measurements

UNDERWATER ACOUSTIC CHANNEL ESTIMATION AND ANALYSIS

Examination Optoelectronic Communication Technology. April 11, Name: Student ID number: OCT1 1: OCT 2: OCT 3: OCT 4: Total: Grade:

ULTRASONIC FIELD RECONSTRUCTION FROM OPTICAL INTERFEROMETRIC

In order to obtain higher sensitivity and broader bandwidth,

Nd:YSO resonator array Transmission spectrum (a. u.) Supplementary Figure 1. An array of nano-beam resonators fabricated in Nd:YSO.

Exposure schedule for multiplexing holograms in photopolymer films

USE OF GUIDED WAVES FOR DETECTION OF INTERIOR FLAWS IN LAYERED

Spectral Distance Amplitude Control for Ultrasonic Inspection of Composite Components

EITN85, FREDRIK TUFVESSON, JOHAN KÅREDAL ELECTRICAL AND INFORMATION TECHNOLOGY. Why do we need UWB channel models?

Lesson 02: Sound Wave Production. This lesson contains 24 slides plus 11 multiple-choice questions.

Laser Beam Analysis Using Image Processing

Target Echo Information Extraction

Microwave-induced acoustic imaging of biological tissues

RapidScan II Application Note General Composite Scanning

MORPHOLOGICAL FILTERS: STATISTICAL EVALUATION AND

( ) 2 ( ) 3 ( ) + 1. cos! t " R / v p 1 ) H =! ˆ" I #l ' $ 2 ' 2 (18.20) * + ! ˆ& "I #l ' $ 2 ' , ( βr << 1. "l ' E! ˆR I 0"l ' cos& + ˆ& 0

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA

Implementation of Orthogonal Frequency Coded SAW Devices Using Apodized Reflectors

NARROWBAND ULTRASONIC SPECTROSCOPY FOR NDE OF LAYERED STRUCTURES T. Stepinski and M. Jonsson 1 Uppsala University, Uppsala, Sweden

Receiver Signal to Noise Ratios for IPDA Lidars Using Sine-wave and Pulsed Laser Modulation and Direct Detections

Transcription:

ECNDT 006 - Poster 04 Non-Contact Ultrasound Characterization of Paper Substrates María HELGUERA, J. ARNEY, N. TALLAPALLY, D. ZOLLO., CFC Center for Imaging Science, Rochester Institute of Technology, Rochester, NY, USA Abstract- Different kinds of paper varying in basis weight, thickness, etc. and finishing characteristics such as cast, gloss, matte were analyzed with and without deposited ink. A 1.7 MHz Ultran non-contact ultrasound focused transducer was operated in the pulse-echo mode to investigate the samples following a raster scan on a 1.5 cm by 1.5 cm area. Both sides of each sample were imaged under this protocol. A pre-designed pattern consisting of some text and a rectangular solid block was printed on the front side of the samples using a Xerox Nuvera10 laser printer and the imaging protocol repeated. C-scan images created from the envelope detected data provide a promising means to investigate and visually differentiate the mechanical properties of the samples as ink is deposited, as well as to differentiate front and back sides of each sample. The second normalized intensity moment and Signal to Noise Ratio (SNR) of the signal envelope are investigated to test their validity to discriminate between different kinds of paper as well as differences in scattering properties when ink is deposited. 1.0 Introduction Recent developments have shown the advantages of using non contact ultrasound for the evaluation of paper substrates [1],[],[3],[4]. Fiber orientation, basis weight, thickness as well as surface roughness are some of the properties that distinguish one paper from another. In this work we assume that surface characteristics change when ink is deposited. To test this hypothesis experiments were designed to interrogate a variety of papers using non-contact ultrasound in the pulse-echo mode. Data are collected for six samples having thicknesses from 0.1 mm to 0.1 mm and various finishing characteristic properties such as gloss, matte, super gloss and cast. In medical applications it has been demonstrated that ultrasonic classification of tissues may be accomplished by analyzing the statistical properties of the intensity signal [5]. According to Eq. 1, Non-Rayleigh statistics provide a valuable model when the second normalized intensity moment (I ) deviates from its Rayleigh limit of [6],[7]. Specifically, if there is sufficient number of scatterers in the cell volume with spacing at or near integer multiples of half the wavelength, a coherent phasor can build up in a 1

random walk problem [8]. The probability density function follows a Rice distribution and I manifestly attains a value below. I I 1 = + (1) M eff Where I is intensity and it is equal to the square of the magnitude, and M eff is the effective number of scatterers within the ultrasound beam..0 Experimental methods Six paper samples with and without ink on the top surface were used for experimentation. They are (1) Domtar Luna matte, () Xerox gloss, (3) Rey Success Super gloss, (4) Mead West Vaco ultra cast, (5) Sappi Voltage gloss, and (6) Rey Success gloss. A non-contact Ultran 1.7MHz focused transducer was used to performed a raster scan on an area of.5cm on the top and bottom faces of each paper sample as is shown in Figure 1. Text and a solid block were printed with a Xerox Nuvera10 laser printer and the protocol repeated. The step size of the scan was 500μm. Data were collected using a 500MHz LeCroy Waverunner 6051 digital oscilloscope which controlled the x-y stepper motors. Figure 1. Experimental setup. A C-scan is formed from a collection of A-lines at a plane perpendicular to the propagation axis. The Hilbert transform is applied to the RF data (A-line) to obtain an imaginary part. The envelope is then calculated as the magnitude of the complex signal with Eq. : E ( f n) ) = R( f ( n) ) + I( f ( n )) ( () Intensity is the square of the amplitude, as expressed by Eq. 3: ( f ( n) ) E( f ( n) ) I = (3) A C-scan is calculated from the envelope of the A-lines comprising the raster scan.

3.0 Results and Analysis Figure shows a plot of the second normalized intensity moment for the top and bottom surfaces of six paper samples. The x-axis of the plot corresponds to the six paper samples numbered in the previous section. The variation in the second normalized intensity moment for samples without ink is explained by means of Eq. 1. The effective number of scatterers that contribute to the backscatter signal arriving at the transducer varies from paper to paper. Based on estimates of the speed of sound in paper for normal incidence [3] we assume a wavelength of 0.3 mm in paper. Individual scatterers in the paper substrate are not resolved, rather, it is the coherent interference of their echoes that determines the statistical behavior of the intensity signal. On the other hand, when ink is deposited, it is observed that the second normalized intensity moment is lower than in the corresponding samples without ink, furthermore it is observed that it remains fairly constant across samples at 1.40±0.1, which is below the Rayleigh limit. In this case, it is the toner particles that are responsible for the scattering. Since the same pattern was printed on all samples using the Xerox Nuvera10 laser printer this result was expected. Figure. Second normalized moments of paper samples with and without ink on top surface. 1-Domtar luna matte, -Xerox gloss, 3-Rey supper gloss, 4-Mead ultra cast, 5-Sappi gloss, 6-Rey success gloss The signal-to-noise-ratio (SNR) of the intensity signal was also investigated for the same samples. Results are shown in Figure 3. The SNR for samples with ink is consistently higher that in samples without ink. Once again, this result was expected since the variance for samples with ink was lower than in samples without ink. Figure 3. SNR of the envelope data 3

Both SNR and second normalized moments appear to have validity as classification parameters. Clustering results are shown in Figure 4. Figure 4. Classification of paper substrates with and without ink. Figure 5 shows C-scan pseudo-color images of a.5 cm area of the different paper samples with and without ink, front and back sides. It is observed that the C-scan images differ as ink is deposited on the top surface of the paper samples. The difference in appearance is due to different modes of propagation of ultrasound waves as they propagate on the paper. Characteristics such as grain, surface roughness, color, can be used to differentiate paper samples. For example, the Rey Success Color Lasser super gloss, Domtar Luna matte paper samples have elongated pits. Whereas for Sappi Voltage gloss and Rey success Color Laser gloss pits are not apparent. These characteristics seem to match the wave pattern shown in the corresponding C-scan images. Figure 5. C-scan images of 6 paper samples showing top surface with and without ink, and bottom surface. 4

4.0 Conclusions A non-contact pulse-echo ultrasound protocol was designed to study the scattering of papers varying in basis weight, caliper, surface roughness and surface finishing. Samples where analyzed with and without ink. The second normalized intensity moment and SNR of intensity signal appear to be valuable parameters for classification of samples. On the other hand, C-scan images provide a promising means to investigate and visually differentiate the mechanical properties of the samples as ink is deposited, as well as to differentiate front and back sides of each sample. This work concentrated in the analysis of the spatial (temporal) backscattered signal in order to avoid complications brought about by leakage and aliasing in the frequency domain. References [1] McIntyre, C, Hutchins, D, Billson, D, and Stor-Pellinen, J., The Use of Air-Coupled Ultrasound to Test Paper, IEEE Trans. Ultrason., Ferroelec. Freq.Cont., 48(3), pp. 717-77, 001. [] Gan, TH, Hutchins DA, Billson DR, Schindel DW, High-resolution, air-coupled ultrasonic imaging of thin materials, IEEE Trans. Ultrason., Ferroelec. Freq. Cont., 50(11), pp. 1516-154, 003. [3] Gómez, TE, González B, Montero F, Paper characterization by measurement of thickness and plate resonances using air-coupled ultrasound, IEEE Ultrasonic Symposium, 1, pp. 865-868, 00 [4] Bhardwaj, M., High transduction Piezoelectric transducers and Introduction of Non-Contact Analysis, NDT.net, 5(1), 000. [5] Chen, JF, Zagzebski, A., and Madsen, EL, Non-Gaussian versus Non-Rayleigh statistical properties of ultrasound echo signals, IEEE Trans. Ultrason. Ferroelec. Freq. Cont., 41(4), pp. 435-440, 1994. [6] Helguera, M., Non-Rayleigh Ultrasonic Characterization of Tissue Scattering Microstructures Via a Multibandwidth Probing Technique, Ph.D. Dissertation, Rochester Institute of Technology, 1999. [7] Shankar, PM, A model for ultrasonic scattering from tissues based on the K distribution, Phys. Med. Biol., 40, pp. 1633-1649, 1995. [8] Tuthill, T., Sperry, RH, Parker, KJ, Deviations from Rayleigh Statistics in Ultrasound Speckle, Ultrasonic Imaging, 10, 1988. 5