Features Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 60W of AC-DC Power Universal Input 90-264Vac Input Range IP22 Rated Enclosure Meets Heavy Industrial Levels of EN61000 EMC Requirements Meets EN55011/CISPR11, FCC Part 15.109 Class B Conducted & Radiated Emissions, with 6db margin Approved to EN/IEC/UL60950-1, 2 nd Edition, Am. 2 E-cap life of >8 years >900,000 hours MTBF 3 Year Warranty IP22 Rated Enclosure Description A high performance AC to DC external power supply family designed for test & measurement and industrial applications. Fully compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, and also compliant to the Heavy Industrial levels of various EN61000-4-x standards for EMC. The TE60A series models also meet Class B conducted and radiated EMI per FCC Part 15, EN55022, CISPR22. Designed to allow easy integration with test and measurement equipment and other industrial applications. Model Selection Model Output Output Ripple & Line Load Output Cable Input Number Volts Current Power Noise¹ Regulation Regulation & Connector Configuration TE60A0551F01 5.0V 7.00A 35W 75mV pk-pk ±1% ±5% 6 pin Molex Type 2 TE60A0903F01 9.0V 6.00A 54W 90mV pk-pk ±1% ±5% TE60A1203F01 12.0V 5.00A 60W 120mV pk-pk ±1% ±5% 1150mm long, UL2464, TE60A1503F01 15.0V 4.00A 60W 150mV pk-pk ±1% ±5% 18AWG, 4 conductors; TE60A1803F01 18.0V 3.40A 60W 180mV pk-pk ±1% ±5% 2.5 x 5.5 x 9.5mm Straight TE60A2403F01 24.0V 2.70A 60W 240mV pk-pk ±1% ±5% TE60A4803F01 48.0V 1.35A 60W 480mV pk-pk ±1% ±5% TE60A0551N01 5.0V 7.00A 35W 75mV pk-pk ±1% ±5% 6 pin Molex Type 2 TE60A0903N01 9.0V 6.00A 54W 90mV pk-pk ±1% ±5% TE60A1203N01 12.0V 5.00A 60W 120mV pk-pk ±1% ±5% 1150mm long, UL2464, TE60A1503N01 15.0V 4.00A 60W 150mV pk-pk ±1% ±5% 18AWG, 4 conductors; TE60A1803N01 18.0V 3.40A 60W 180mV pk-pk ±1% ±5% 2.5 x 5.5 x 9.5mm Straight TE60A2403N01 24.0V 2.70A 60W 240mV pk-pk ±1% ±5% TE60A4803N01 48.0V 1.35A 60W 480mV pk-pk ±1% ±5% TE60A0551Q01 5.0V 7.00A 60W 75mV pk-pk ±1% ±5% 6 pin Molex Type 2 TE60A0903Q01 9.0V 6.00A 54W 90mV pk-pk ±1% ±5% TE60A1203Q01 12.0V 5.00A 60W 120mV pk-pk ±1% ±5% TE60A1503Q01 15.0V 4.00A 60W 150mV pk-pk ±1% ±5% TE60A1803Q01 18.0V 3.40A 60W 180mV pk-pk ±1% ±5% TE60A2403Q01 24.0V 2.70A 60W 240mV pk-pk ±1% ±5% TE60A4803Q01 48.0V 1.35A 60W 480mV pk-pk ±1% ±5% Notes: 1150mm long, UL2464, 18AWG, 4 conductors; 2.5 x 5.5 x 9.5mm Straight Class I Desktop, IEC60320 C14 Class II Desktop, IEC60320 C8 Class II Desktop, IEC60320 C18 1. Measured at the output connector, with noise probe directly across output and load, terminated with 0.1μF ceramic and 47μF low ESR capacitors. For 5V and 6V models, values listed are typical, 100mV pk-pk maximum. 2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information. 3. For Input Class I models: For AC GND connected to output common (-), insert a B in the part number where the A is located (TE60B1203F01). 4. All specifications are typical at nominal input, full load, at 25 C ambient unless noted. www.slpower.com TE60 Rev 2.6 11-MAR-16 1
General Specifications AC Input 100-240Vac, ±10%, 47-63Hz, 1 Turn On Time Less than 1 sec @115Vac, full load Input Current 115Vac: 1.5A, 230Vac: 0.75A Hold-up Time 20mS min., at full Load, 100Vac input Inrush Current 264Vac, cold start: will not exceed 40A Overtemperature Will shutdown upon an over-temperature condition, auto-recovery. Input Fuses F1, F2: 2A, 250Vac fuses (line & neutral lines) provided on all models Overload 130 to 180% of rating, Hiccup Mode Earth Leakage Current Input-GND: <500μA@264Vac, 60Hz, NC Output-GND: <4mA@264Vac, 60Hz, NC Short Circuit Hiccup Mode, auto recovery. Efficiency Meets US DoE Efficiency Level VI average efficiency levels Overvoltage 130 to 150% of output voltage (max. 60V on 48V model), hiccup mode Output Power 60W continuous See models chart for specific voltage model ratings. Isolation Input-Output: 4000Vac Input-Ground: 1500Vac Output-Ground: 1500Vac No Load Input Power <0.210W per DoE Efficiency Level VI Requirements Safety Standards EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2 Ripple and Noise See models chart on pg 1. Operating Temperature Output Voltage See models chart on pg 1. Case Temperature Transient Response E-Cap Life 500µs response time for return to within 0.5% of final value for any 50% load step over the range of 5% to 100% of rated load, i/ t< 0.2A/µs. Max. voltage deviation is +/-3.5%. >7 year life based on calculations at 115Vac/60Hz & 230Vac/50Hz, ambient 25 C at 24 hrs per day, 365 days/year, 6 power up cycles per day. (80% load on 12V model) Temperature Derating MTBF -20 C to +70 C. Derate above 40 C. Start Up at -40 C, full load, (warmup period before all parameters are within published specifications). Case Temperatures are within regulatory guidelines. Care should be taken to avoid prolonged contact with skin or other heat sensitive surfaces. See derating curve below. >250,000 hours, full load, 110 & 220Vac input, 25 C amb., per Telcordia 332 Issue 6. Weight 400g Storage Temperature -40 C to +85 C Safety Drop Test 1.4m from table top to wooden platform, 6 faces. Altitude Operating: to 5000m Non-operating: -500 to 40,000 ft. Dimensions W: 2.67 x L: 4.25 x H: 1.29 W: 67.9mm x L: 108mm x H: 32.7mm Relative Humidity 5% to 95%, non-condensing Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 min/axis, 1-500Hz. Non-Oper.: random waveform, 3 minutes per Vibration axis, 3 axes and Sine waveform, Vib. frequency/acceleration: 10-500Hz/1g, sweep rate of 1 octave / minutes, Vibration time of 10 sweeps / axes, 3 axes All specifications are typical at nominal input, full load, at 25 C ambient unless noted. Shock Operating: Half-sine, 20gpk, 10mS, 3 axes, 6 shocks total Non-Operating: Half-sine waveform, impact acceleration of 100G, Pulse duration of 6 ms, Number of shocks: 3 for each of the three axis www.slpower.com TE60 Rev 2.6 11-MAR-16 2
EMI/EMC Compliance Conducted Emissions: Radiated Emissions: Common Mode Noise: Electro-Static Discharge (ESD) Immunity on Power ports: Radiated RF EM Fields Susceptibility Electrical Fast Transients (EFT) /Bursts: Surges, Line to Line (Diff Mode) and Line to GND (CMN Mode) Conducted Disturbances induced by RF Fields Rated Power frequency magnetic fields Voltage Interruptions, Dips, Sags & Surges Harmonic Current Emissions Flicker Test EN55011/CISPR22 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac EN55022/CISPR22 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac High Frequency (100kHz-20MHz): <40mA pk-pk EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz EN55024/IEC61000-4-4, Level 4, +/- 4kV, 100Khz rep rate, 40A, Criteria A EN55024/IEC61000-4-5, Level 4, +/-1kV DM, +/-4kV CM, Criteria A EN55022/IEC61000-4-6, 10Vrms Level 4, in ISM and amateur radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz EN55024/IECEN61000-4-11: --100% dip for 20mS, Criteria A --100% dip for 5000mS (250/300 cycles), Criteria B --60% dip for 100mS, Criteria B --30% dip for 500mS, Criteria A EN55011/EN61000-3-2, Class A EN61000-3-3 All specifications are typical at nominal input, full load, at 25 C ambient unless noted. MTE60 Series Output Power Derating Curve: Output Power- Watts TE60 Family Derating curve 70 60 50 40 30 20 10 0-20 -10 0 10 20 30 40 50 60 70 Ambient Temperature- C 12V 18V 24V 48V www.slpower.com TE60 Rev 2.6 11-MAR-16 3
Mechanical Drawing: Notes: 1) All dimensions in (mm). 2) 2.5mm barrel connector shown, other options are available. 3) The unit should not be covered or enclosed to protect against excessive case temperature rise. Connector Information Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. Other standard options are listed below. The 03 in the standard model number is replaced by the applicable digits below: www.slpower.com TE60 Rev 2.6 11-MAR-16 4
Efficiency Level VI Information: TE60A 12V-48V TE60A 5V Data Sheet 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com TE60 Rev 2.6 11-MAR-16 5