THE RUSSIAN STANDARDS AND THE OPINION ABOUT INTERNATIONAL HARMONIZATION OF ELECTROMAGNETIC STANDARDS

Similar documents
Proceedings, International Conference on Cell Tower Siting Linking Science & Public Health, Salzburg, Austria, June 7-8, 2000, p 47-51

Regulatory Guidance and Safety Standards

Human Exposure Requirements for R&TTE and FCC Approval

EMF risk for operators mounting, adjusting and maintaining base stations

Technical Committee106 Methods for the assessment of electric, magnetic and electromagnetic fields associated with human exposure

> Microwave Ovens and their Hazards

Health Issues. Introduction. Ionizing vs. Non-Ionizing Radiation. Health Issues 18.1

IEEE ICES Exposure Limits Above 6 GHz

Royal Street Communications, LLC Proposed Base Station (Site No. LA0366A) 315 4th Avenue Venice, California

WHITEPAPER WHITEPAPER

v1.0.1 March AlphaLab, Inc. All rights reserved. TriField EMF Meter Owner s Manual

Technical Note 2. Standards-compliant test of non-ionizing electromagnetic radiation on radar equipment

INTRODUCTION well below

Verizon Wireless Proposed Base Station (Site No Berkeley Bekins ) 2721 Shattuck Avenue Berkeley, California

National Radiation Commission P.O.Box 743, Arusha, Tanzania.

2200 Noll Drive Lancaster, PA Latitude: N 40º (NAD 83) Longitude: W 76º (NAD 83) 362 AMSL

RADIOFREQUENCY ELECTROMAGNETIC FIELDS

ITU-T Study Group 5. EMF Environmental Characterization

Verizon Wireless Proposed Base Station (Site No South Goleta ) 4500 Hollister Avenue Santa Barbara, California

AT&T Mobility Proposed Base Station (Site No. CN4779A) 1101 Keaveny Court Walnut Creek, California

Verizon Wireless Proposed Base Station (Site No Lake Cachuma ) 2680 Highway 154 Santa Barbara County, California

Area Network Applications] Notice: This document has been prepared to assist the IEEE P It is

Precautionary Principle in Health Protection Policies regarding Electromagnetic Fields (EMF)

Harmful Effects of Mobile Phone Tower Radiations on Muscle and Bone Tissues of Human Body at Frequencies 800, 900, 1800 and 2450 MHz

Verizon Wireless Proposed Base Station (Site No Palos Verdes ) 1506 Camino Verde Walnut Creek, California

Questions and Answers about Biological Effects and Potential Hazards of Radiofrequency Electromagnetic Fields

Report On. RF Exposure Assessment of the Sepura plc SRG3900 with AQHB Antenna. FCC ID: XX6SRG3900UW Industry Canada ID: 8739A-SRG3900UW

Wireless Facility Radio Frequency Exposure Compliance Review

After having perused the Decree Law No. (31) of 2002 on Protection from Radiation,

RF EMF Strength Meter

8GHz RF EMF Strength Meter

Product Compliance Assessments of Low Power Radio Base Stations with Respect to Whole-Body Radiofrequency Exposure Limits

HAZARDS OF NON-IONIZING RADIOFREQUENCY (RF) RADIATION

RF Radiation Safety Training

Health Implications from Mobile Communication Systems

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

Measurements of Exposures Around Vodafone New Zealand Limited Cellsites from June 2012 to May 2013

NEW IEEE C RF SAFETY STANDARD

Electromagnetic Fields, Mobile Telephones and Health

Feasibility of a cohort study of persons exposed to radiofrequency electromagnetic fields in an occupational setting

Eight Myths about Mobile Phones and Base Stations

Low-EMF Best Practices

RF AND MICROWAVE SAFETY PROGRAM

RF EMF Strength Meter

IOSH Webinar. Control of Electromagnetic Fields at work regulations 2016 Part 2 EMF exposure assessment 4 th May 2017 Julia Clark FSRP CMIOSH

TESTING OF ELECTROMAGNETIC RADIATION RESONATOR-CONVERTER PROTOTYPE

YARRANLEA SOLAR PROJECT. Electromagnetic Radiation Assessment. Zenviron Document: 8013-EL-R

EN EMF REPORT For. Two way radio Model No.: RT-5R

Product Safety and RF Energy Exposure Booklet for Mobile Two-Way Radios Installed in Vehicles or as Fixed Site Control Stations ATTENTION!

Executive Summary: Report on Health Canada Survey of Ultraviolet Radiation and Electric and Magnetic Fields from Compact Fluorescent Lamps

R ICHARD T ELL A SSOCIATES, INC.

RF EMF Strength Meter

Simulation of Electromagnetic Radiation Levels for some Radiocommunication Systems

ELECTROMAGNETIC POLLUTION INSIDE HIGH VOLTAGE SUBSTATION

ELECTROMAGNETIC 0 Hz 300 GHz

Comparative Study of the Effect of Microwave Radiation Neutralizers On Physiological State of Human Subjects

ELECTROMAGNETIC FIELDS RADIATED BY SMART POWER METERS IN RELATION TO US SAFETY GUIDELINES

Analysis of SAR in Human Blood, Bones and Muscles due to Mobile Waves at 900MHz,1800MHz and 2400MHz

Class: RPT Doc. no: RE Rev: A Date: Approved by: JCP

ELECTROSMOG METER INSTRUCTION MANUAL

MAGTFTC, MCAGCC SOP FOR RADIO FREQUENCY (RF) PERSONNEL PROTECTION PROGRAM

Analytical Design Optimization of 765 kv Transmission Line Based on Electric and Magnetic Fields for Different Line Configurations

This is a preview - click here to buy the full publication

RADIO FREQUENCY NIER REPORT

CHARACTERISTICS, DOSIMETRY & MEASUREMENT OF EMF

Rational and Summary of Exposure and Dosimetry

Workplace safety for demagnetizer operators

REPORT ON THE RESEARCH WORK

Abbey Court Irish Life Centre Lower Abbey Street Dublin 1 Tel Fax Web

Department of Defense INSTRUCTION. SUBJECT: Protection of DoD Personnel from Exposure to Radiofrequency Radiation and Military Exempt Lasers

Biljana Tanatarec Doron Net d.o.o. ISO/HZN National Workshop on Social Responsibility Zagreb, 9 10 September 2010

Developing and Implementing Protective Measures for ELF EMF - Sources and exposures- Rüdiger Matthes Federal Office for Radiation Protection Germany

Calculated Radio Frequency Emissions Report. Cotuit Relo MA 414 Main Street, Cotuit, MA 02635

ITU-D activities on EMF

Radio Frequency Electromagnetic Energy (RF-EME) Compliance Report

Instructions for the TES 593 RF Meter

3G Mini-Card Gobi2000

KEY WORDS: conductive, clothing, live, line, maintenance, high, voltage

SCANTER 5000 and 6000 Radar Series

Abbey Court Irish Life Centre Lower Abbey Street Dublin 1 Tel Fax Web

Safety Code 6 (SC6) Measurement Procedures (Uncontrolled Environment)

Safety in electromagnetic fields. EMF Directive 2013/35/EU

GEISLAVARNIR RÍKISINS ICELANDIC RADIATION SAFETY AUTHORITY

Safety Code 6 Analysis Freedom Mobile 3G & LTE Network. Radio frequency exposure for uncontrolled and controlled environment.

Abbey Court Irish Life Centre Lower Abbey Street Dublin 1 Tel Fax Web

Abbey Court Irish Life Centre Lower Abbey Street Dublin 1 Tel Fax Web

MAXIMUM PERMISSIBLE EXPOSURE ADDENDUM REPORT TO (Measurement)

SAR REDUCTION IN SLOTTED PIFA FOR MOBILE HANDSETS USING RF SHIELD

Radiation Survey of Dielectric (RF) Heaters in Canada*

Product Safety and RF Energy Exposure Booklet for Portable Two-Way Radios

Some Aspects of the Labor Risk in Physiotherapy Due to Microwaves

Policy on Non-Ionizing Radiation in Israel

RF EMF Strength Meter

Occupational Exposure to Base Stations Compliance With EU Directive 2004/40/EC

Abbey Court Irish Life Centre Lower Abbey Street Dublin 1 Tel Fax Web

EMF ASSESSMENT REPORT

Commission K Triennial Report

Radio Frequency Fields Survey at Waurn Ponds Campus Pigdons Road, Geelong, VIC For Deakin University. EMC Technologies Report No.

RF EMISSIONS FROM SMART GRID ELECTRIC METERS, HAN DEVICES, AND THEIR RELATIONSHIP TO THE FCC MAXIMUM PERMISSIBLE EXPOSURE LIMIT (MPE)

International Conference KNOWLEDGE-BASED ORGANIZATION Vol. XXIII No

Transcription:

It was published: International Seminar on Electromagnetic Fields. GLOBAL NEED FOR STANDARDS HARMONIZATION. October 9, 1998. Ljubljana, Slovenia.pp. 1I-6I. THE RUSSIAN STANDARDS AND THE OPINION ABOUT INTERNATIONAL HARMONIZATION OF ELECTROMAGNETIC STANDARDS Grigoriev Yu. Institute of Biophysics, Centre of Electromagnetic Safety Russia, Moscow The problem of hygienic EMF standards as a factor of industrial and human being environment acquired the special urgency for the last years. The main fundamental preventive direction ensuring optimization of conditions of the human being vital activity, because of constant increase of EMF level in the environment is the regulation of EMF levels of effect for workers and population. 1. To history of the EMF standards in Russia. In this connection it is necessary to underline that 40 years ago, i.e. in 1958 in Russia (USSR) the first EMF standard in the range of 300 MHz 300 GHz was authorized at the state level. In this information I see the following important circumstance: we can trace dynamics of change of normative levels in Russia over the time of 40 years, that will reflect the degree of stability of our fundamental knowledges about biological effects of various EMF frequencies. The first Russia standards were based on the results of clinicohygienic researches of the 50-ths, reinforced by the experimental data, having been available provided limitation of two rationed parameters - intensity and time of exposure with the determination of three limits: µw/cm 2 - for 8 h; 0 µw/cm 2 - up to 2 h and 00 µw/cm 2 - up to 20 minutes for a working day. Without discussing the role of the confirmed standards 40 years ago for the improvement of the working conditions, that is indisputable, it is necessary to underline that these standards for expired 40 years were not subjected to essential changes. Besides for the last 25 years the accumulated material has shown the reliability of these standards and, apparently, certain validity. The following materials were used to validate the first standards The results of clinicohygienic researches carried out at of enterprises of electronic and a radioindustry of Russia, during which the condition of health of 15 persons were evaluated (Savin B.M. et al.,1983). The clinicîhygienic comparisons have shown, that the personnel working for the long time in the electronic industry (15-20 years), where microwaves intensity does not as a rule exceed -0 µw/cm 2 do not reveal somewhat essential changes in their health compared to that of the appropriate age groups. The disturbance in the health condition which could be connected with the microwaves effect were detected among 2.6 % of the personnel at the enterprises of the radioindustry. In all cases we could speak about the experts with more than 15 years of experience who could be exposed to significant intensity in the past (up to mw/cm 2 and above). The personnel with the experience less than 15 years, i.e. those who began their work after the realization of protective measures and were exposed to microwaves with the intensity up to 00 µw/cm 2 did not reveal occupational diseases. At the first stage of standardization in Russia the results of the following researches were also used. Biological effects of 9 modes of EMF exposure were evaluated: 3 GHz, power

2 density from 0,25 up to µw/cm 2 and time (T) of daily irradiation from 6 min. to 4 h. A large part of experimental researches were conducted in the form of chronic experience up to 4 months. Total quantity of animals (rabbits, rats, mouse), used in the researches exceeded 1160. The bioeffects of microwaves were evaluated on the base of functions of the central nervous and neuroendocrinal systems, unspecific and specific immunity, generative function and etc. The results of the experimental researches have shown distinct dependence between microwaves bioeffects and the intensity of exposure. They have confirmed the earlier available data about the expressed biological effect of microwaves exposure to the power density of 4 mw/cm 2 and especially mw/cm 2. The effects of the indicated intensity provoked distinct changes of functional condition of the central nervous and endocrinal systems, immunity and etc. The changes arose at the early stages of exposure had shown for stability and had cumulative character. By transition to lower intensities (1 mw/cm 2 ) the decrease of biological activity of microwaves was observed. Microwaves of power density 250 µw/cm 2 during 4- hours exposition daily during 4 months provoked only easy functional shifts of separate parameters carrying adaptive character. The analysis of all data has allowed to establish that the parameters of effects characterizing the threshold of affect of the factor are 1 mw/cm 2 for T = 120 min (S = 120 mw/cm 2 or 2000 µw. h/cm 2 ) and mw/cm 2 for 25 min > T > 6 min (4166 µw. h/cm 2 > S> 00 µw (h/cm 2 ). Using the safety factor equal to (which is quite sufficient in case of the factors not showing distinctly expressed cumulative properties) experimentally established allowable exposure will be: 0 µw/cm 2 for T = 120 min and 00 µw/cm 2 for T 25 min > T > 6 min. Based on the above mentioned data the following offers were formulated: 1) normative levels of effect 0 µw/cm 2 for T 2 h; 2) under the certain permissible correlation between of the intensity and duration of EMF exposure the power density may be 200 µw. h/cm 2. 2. System of a sanitary-hygienic standardization of electromagnetic fields in Russia. In Russia the system of the standards on electromagnetic safety consists of State Standards (GOST) and Sanitary norms and regulations (SanPiN). These interconnected documents are mandatory for performance on the whole territory of Russia. The EMF State Standards are included into the group of System of the standards of safety transactions - the complex of the standards containing demands, norms and regulations directed to the safety, health maintenance and serviceability of the person during transactions. They are the most general documents. The commissioning State Standards executes State Committee on standardization of the Russian Federation. The State Standards of Russia in the field of electromagnetic safety as on June 1, 1998 are indicated in table 1. Table 1. State EMF Standards of Russian Federation (as on June 1, 1998)

3 _ Number The name 1. GOST 12.1.006-84 Occupational safety standards system. Electromagnetic fields of radio frequencies. Permissible levels at work-places and requirements for control 2. GOST 12.1.002-84 Occupational safety standards system. Power frequency electric fields. Permissible levels of field strength and requirements for control at workplaces 3. GOST 12.1.045-84 Occupational safety standards system. Electrostatic fields. Tolerance levels and methods of control at working places The Sanitary norms and regulations regulate hygienic demands to more particular situations of irradiation and also to separate kinds of production. The Sanitary norms and regulations contain the same main items as the State Standards, however in more detail. As a rule, the sanitary norms and regulations are accompanied by the methodical instructions on realization of the control of electromagnetic conditions and protective measures. The commissioning of the Sanitary norms and regulations executes the Ministry of Public Health of the Russian Federation. At present 15 EMF sanitary norms and rules function in Russia. The main values of EMF permissible levels are presented in Fig. 1 8. 60 Fig. 1. Limit values for electrostatic field strength E (workplace) according GOST 12.1.045-84 50 40 E, kv/m 30 20 0 1 2 3 4 5 6 7 8

4 Fig. 2. Limit values for 50 Hz electric field strength E (workplace) according to GOST 12.1.002-84 0 E, kv/m 1 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,5 8 6000 Fig. 3. Limit values for 50 Hz magnetic field strength H (workplace) according to SanPiN 3206-85 5000 4000 H, A/m 3000 2000 00 0 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,5 8

5 Fig. 4. Limit values for 50 Hz electric field strength E (public areas) according SanPiN 2971-84 00 V/ 500 V/m Inside the buildings Outside of the buildings 00 Fig. 5. Limit values for electric field strength E (workplace)according to GOST 12.1.006-84 and SanPiN 2.2.4/2.1.8.055-96 Frequency range 0,03-3 MHz 3-30 MHz 30-300 MHz E, V/m 0 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,5 8

6 0 Fig. 6.Limit values for magnetic field strength H (workplace) according to GOST 12.1.006-84 and SanPiN 2.2.4/2.1.8.055-96 Frequency range 0,03-3 MHz 30-50 MHz H, A/m 1 0,1 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,5 8 00 Fig. 7. Limit values for power flux density S in the frequency range 0,3-300 GHz (workplace) according to GOST 12.1.006-84 and SanPiN 2.2.4/2.1.8.055-96 S, uw/sq.cm 0 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,5 8

7 0 Fig. 8. Limit values for electric field strength E and power flux density S (public areas) according to SanPiN 2.2.4/2.1.8.055-96 E, V/m S, uw/sq.cm 1 30 khz 300 khz 3 MHz 30 MHz 300 MHz 3 GHz 30 GHz 300 GHz 3. General principles to the approach to EMF standardization in Russia. The threshold principle of injurious to health is used as the basis of EMF limits The position "damage-favour" is considered through the concept of risk. Such EMF permissible value limits are accepted for the certain resources with usual daily EMF irradiation regimes which do not lead to diseases or health deviations among the population (irrespective of age or sex) which can be detected by modern methods during the period of irradiation or long after it was over. The EMF exposure should not provoke in the person even temporary disturbance of homeostasis including reproductive function, and also the effort protective and adaptationcompensator mechanisms neither in the nearest, nor in the remote period of time. It means, that EMF limits are the fractional quantity from minimal level of EMF which is capable to provoke some reaction in the human being. 4. Common and different the approaches to working out EMF standards between some European countries, USA, ICNIRP and Russia. Common point of view: 1) A safety factor equal to - to provide an additional safety margin and elimination of biological uncertainty. 2) There are separate limitations for occupational personnel and for general public. Differences:

8 First of all, NCRP US recommendation (1981) about unit-mass time averaged rate of energy absorption (SAR) as the meaningful dosimetric quantity. Up to now in Russia we use "a power load" - total flow of energy dropping per unit of an irradiated surface during irradiation time in hours. 2. There are traditional differences in the philosophy of the estimation of any measurable effect, which is considered for determination of EMF danger: à) the effect to which the organism of a human being can adapt or b) only those selected effects that can be considered pathological. 3. The role of modulation is underestimated by some scientists in some countries. These effects were not considered adverse for the following reasons: inability to relate them to human health; the narrow range of effective modulation frequencies and the effects are reversible. At present we have results which are contrary to this point of view (Grigoriev Y.,1996; Aphrikanova L., Grigoriev Y.,1996; Grigoriev Y.,Stepanov B., 1998; Choy et al., 1986). 4. There is another system of consideration and affirmation of the standards in Russia. The National Commission on Protection against non-ionizing radiation was absent in Russia till August 1998. Only in September 1998 ICNIRP in the limits of NCRP was established (chairman - professor Yu. Grigoriev). Up to now to developing sanitary norms and rules were sent to the Institute of Occupational Health (RAMS). After that they are sent to the Commission of RF Ministry of Public Health and after that they were where authorized before the confirmation by RF Ministry of Public Health itself. 5. There are various requests to selection and evaluation of published reports for the substantiation of the standards. ICNIRP Guidelines are not accepted in Russia yet. 6. There are differences in the values between the allowable occupational exposure levels and that for the public. Our suggestions: 1. To develop uniform criteria for the evaluation of the EMF danger and evaluation of an individual radiosensitivity (to draw these approaches nearer). 2. It is necessary to take into account chronic long-term irradiation with the evaluation of the remote effects, cumulation capability. 3. To determine degrees of danger for the modulated EMF irradiation. 4. To develop the approaches of the evaluation of energy absorption for local and total irradiation, depending on wavelength, polarization, irradiation in open and shielded space. 5. It's necessary to continue the methodology of conducting epidemiological and medico-hygienic researches.

9 6. Further development of approaches to transfer the experimental data obtained on animals to the human being. For example, is it possible to transfer the data obtained on mice or rats during long term irradiation of the whole body to using modulated EMF irradiation mode of the cellular phone? However only the head brain of the user of cellular phone is subjected to EMF irradiation. 7. Intensive studies of danger of new sources EMF on the human being, for example, of mobile communication. 8. To introduce the system of an evaluation of the data to use them during the development of standards (ICNIRP Guidelines) in Russia. 9. It's necessary to carry out common work on co-ordination of terms.. It s necessary to organize a temporal joint working group of scientists from European countries, USA and Russia under ICNIRP or WHO to adapt and unify the possible approaches to harmonization the International Standards. Thus, this is our point of view on the possibility of harmonization of the International EMF standards taking in consideration the accumulated experience in Russia. REFERENCE Savin B., Nikonova K., Lobanova E. et al. New tendencies in standardization of microwave electromagnetic radiation. // Hygiene of labour and occupational diseases. 1993. N 3. P.1-4. Yu.G. Grigoriev. The role of modulation in a biological influence of an electromagnetic radiation. // Radiation biology and ecology. 1996. V. 36. N 5. P.659-670. Afrikanova L.A., Grigoriev Yu.G.. The influence of various modes of electromagnetic radiation on heart activity (in experiment). // Radiation biology and ecology. 1996. V. 36. N 5. P.691-699. Yu.G. Grigoriev, Stepanov V. Forming of memory process (inprinting) in chicks after prior exposure to low level electromagnetic fields. // Radiation biology and ecology. 1998. V. 38. N2. P.223-231. Choy R., Monro J., Smith C. Electrical sensitivities in allergy patients. // Clinical Ecology. 1986. V. 4. P. 93-98.