RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Similar documents
omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Temperature Transmitter itemp RTD DIN rail TMT 127

Temperature transmitter itemp PCP DIN rail TMT 121

itemp HART DIN rail TMT112

0 2 1 â Ó. itemp HART TMT182. Technical Information

Technical Information itemp TMT180

Temperature head transmitter itemp PCP TMT 181

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

omnigrad M TR 46 Technical Information Hygienic in-line RTD thermometer PCP ( ma), HART or PROFIBUS-PA electronic

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Resistance thermometer Model TR31, miniature design

Miniature resistance thermometer Model TR33, thread-mounted

itemp PA TMT184 Technical information

Resistance thermometer Model TR30, compact design

0 2 1 â Ó. itemp HART TMT182. Technical Information

Omnigrad S -TR61. Technical Information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Temperature transmitter itemp RTD DIN rail TMT 127

Temperature head transmitter itemp PCP TMT 181

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

4 Ó 5 â. Easytemp TMR31, TMR35. Technical information

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

prosonic T FMU230, FMU231

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OPTITEMP TT 20 Technical Datasheet

Pharma-Temperature Sensor M12 hygienic

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

Technical Information Smartec CLD18

OPTITEMP. Compact sensors

Temperature Transmitters TMT 136, TMT 137

Features and benefits The Omnigrad S TC62 is an industrial thermometer (thermocouple

Temperature head transmitter itemp TC TMT 188

Temperature Sensor with M12 hygienic

ph or ORP Transmitter

Technical Information Smartec CLD18

4 Ó â. Easytemp TMR31, TMR35. Technical information

Omnigrad S -TR63. Technical Information

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Temperature transmitter with local display RIT 261

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

RMA42. Technical Information

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

Temperature Sensor with G1/2" hygienic

Pharma Temperature Sensor G3/8"

Screw-in resistance thermometers with plug connector

Temperature Sensor with M12 hygienic

Temperature measurement TMD 832 head transmitter

Inductive Conductivity Meter ILM

In-Line Resistance Thermometers Model TR25

Pharma Temperature Sensor G3/8"

Level Limit Switch nivotester FTL 370, FTL 372

Coriolis Mass Flow Measuring System promass 40 E

Pressure transmitter For general industrial applications Model A-10

Digital flow ELEMENT transmitter for continuous flow measurement

Conductivity Transmitter

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Conductivity measurement SmarTec S CLD 132

Pressure transmitter for general industrial applications Model A-10

Temperature Sensor for Build-In System G3/8" FLEXadapt

Technical Information Smartec CLD18

Miniature resistance thermometer For sanitary applications Model TR21-C, with integrated sterile connection

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Digital flow ELEMENT transmitter for continuous flow measurement

Pressure transmitter for general industrial applications Model A-10

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

Temperature Sensor for Build-In System G3/8" FLEXadapt

Pressure transmitter For sanitary applications Model SA-11

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Pressure transmitter For general industrial applications Model A-10

Temperature Sensor G1/2" Standard

Electronic Temperature Transmitters

Electrical Temperature Measurement

Miniature resistance thermometer For sanitary applications, for orbital welding Model TR21-B

T22. Torque transducer. Special features. Data sheet

RTD TH17 and TH18. Technical Information. Sanitary RTD temperature assembly with connection head

Resistance thermometers for process technology

Flush pressure transmitter For viscous and solids-containing media Model S-11

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

Digital inductive conductivity transmitter

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Temperature Transmitters - Head Mounted

OEM radar transmitter, for aggressive media level measurement

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Digital conductivity transmitter

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Electronic temperature switch with display Model TSD-30

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

High-quality pressure transmitter For general industrial applications Model S-20

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

Analogue Temperature Transmitter

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P

High-precision process calibrator Model CED7000

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Transcription:

Technical Information TI 273T/02/en 60021667 RTD Temperature Sensor omnigrad T -TSM 480, TR 480 Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Application The Omingrad T type TSM 480 and TR 480 thermometers are used for measuring temperatures from -50 to 200 C. The typical application is in plants or machinery for food & beverage production. Features and benefits PC programmable transmitter with 4...20 ma output Configuration and Visualisation with PC operating software ReadWin 2000 Preset measuring range Highly accurate sensor and electronics Breakdown information in event of sensor break or sensor short-circuit, adjustable to NAMUR NE43 Reliable measurements despite fluctuations in ambient temperature Small, compact design M12 plug-in connector 3-A approval Hygienic process connections: metalto-metal with thread, clamp, Diary and Varivent Various insertion lengths Optional: reduced gauge tip for quick response times Compact thermometer completely made of stainless steel, components in contact with the process in SS 316L/1.4435 Surface finishing of wetted parts: Ra 0.8 µm Pt 100 accuracy class A (DIN EN 60751) 574-02

omnigrad T -TSM 480, TR 480 Function and system design Measuring principle Measuring system In the RTD (Resistance Temperature Detector) thermometers the sensing element consists of an electrical resistance with value of 100 Ω at 0 C (called Pt 100, in compliance with standard DIN EN 60751), which increases at higher temperatures according to a coefficient characteristic of the resistor material (platinum). In industrial thermometers that comply with the DIN EN 60751 standard, the value of this coefficient is α = 3.85*10-3 C -1, calculated between 0 and 100 C. The compact thermometer TSM 480 consists of a complete sensor with Pt 100 (class A, 4 wires connection), a transmitter and a housing with various process connections. The built-in electronics can be programmed via a PC using the M12 plug-in connector and converts the Pt 100 input signal into a temperature linear 4 to 20 ma signal. The TR 480 temperature gauge is completely similar to TSM 480, but it does not include any transmitter. Input values Measured variable Measuring range Temperature Designation Measuring range limits Min. span Pt 100 as per DIN EN 60751-50...200 C 10 K Sensor current: 0.6 ma Output values Output signal TSM 480: analogue 4...20 ma, 20...4 ma TR 480: analogue, Ω Signal on alarm Load Undershooting measuring range: linear decrease to 3.8 ma Exceeding measuring range: linear increase to 20.5 ma Sensor break; Sensor short-circuit: 3.6 ma or 21.0 ma Max. (V power supply - 10V) / 0.023 A (current output) Induced current requirement 3.5 ma Current limitation 23 ma Switch-on delay 2 s 2 Endress+Hauser

omnigrad T- TSM 480, TR 480 Electrical connection Power supply ELECTR_g_gd_05_en_11 Fig. 1: Electrical connection of the TSM 480 compact thermometer (viewed from above), M12 plug, 4-pin Item 1: Power supply 10...35 V DC; Current output 4...20 ma Item 2: PC configuration cable connection Item 3: Power supply 0 V DC; Current output 4...20 ma Item 4: PC configuration cable connection Red Red 4 3 1 2 White White 1xPt100 ELECTR_g_gd_05_en_12 Fig. 2: Electrical connection of the TR 480 temperature gauge (viewed from above), M12 plug, 4-pin Supply voltage U b = 10...35 V DC Residual ripple Permitted residual ripple U ss 3V at U b 13V, f max. = 1 khz Accuracy Electronics response time 1 s Reference operating conditions Calibration temperature: +23 C ± 5 K Measuring error Electronics 0.1 K or 0.08% % refer to the set span. The highest value is valid. Endress+Hauser 3

omnigrad T -TSM 480, TR 480 Sensor Class A tolerance as per DIN EN 60751, with operating temperature range of -50...200 C Measuring error in C = 0.15 + 0.002 ItI ItI = numerical value of the temperature in C, unsigned. Electronics long-term stability 0.1 K/year or 0.05%/year Values under reference operating conditions. % refer to the set span. The highest value is valid. Influence of ambient temperature (temperature drift, TSM 480) Influence of load Pt 100 resistance thermometer: T d = ± (15 ppm/k * (full scale value + 200) + 50 ppm/k * of set measuring range) * ϑ ϑ = deviation of ambient temperature from the reference operating condition. ± 0.02%/100 Ω Values refer to the full scale value. Sensor response time As per DIN EN 60751 in water flowing at 0.4 m/s: Sensor tip t 50 t 90 6 mm 3.0 s 8.0 s 4 mm 2.5 s 5 0 s Influence of supply voltage ±0.01%/V deviation from 24 V Percentages refer to the full scale value. Installation conditions Installation instructions Mounting location a b c INSTAL_g_gd_07_xx_02 Fig. 3: Pipe installation of TSM 480 and TR 480 sensors a b c At angle sections, against the direction of flow In smaller pipes, turned against the direction of flow Perpendicular to the direction of flow 4 Endress+Hauser

omnigrad T- TSM 480, TR 480 Environmental conditions Ambient temperature limits TSM 480: -40...85 C TR 480: 90 C max for the M12 connector Storage temperature -40...90 C Climate class As per EN 60654-1, class C Degree of protection IP67 Shock resistance 4g / 2...150 Hz as per IEC 60068-2-6 Vibration resistance See Shock resistance Electromagnetic compatibility (EMC, TSM 480) Shock resistance and interference emission as per EN 61326-1 (IEC 1326) and NAMUR NE 21 Condensation Permitted Process Process temperature limits -50...200 C Caution! Restrictions dependent on ambient temperature are possible: for TSM 480: max. ambient temperature to 25 C max. process temperature no restrictions to 40 C 145 C to 60 C 130 C to 85 C 110 C Process pressure limits Flow velocity limits With a limited flow velocity, the maximum tolerated pressures are the following: 5 MPa (50 bar) at 20 C 3.5 MPa (35 bar) at 200 C. The highest flow velocity tolerated by the sensor stem diminishes with increasing lengths of the probe exposed to the stream of fluid. Endress+Hauser 5

omnigrad T -TSM 480, TR 480 Mechanical construction Design, dimensions B B A D C L 6.3 55 10 ø18 L 6.3 25 10 M12 ø50.5 37 8 SW22 G1/2" 19 14 ø18 ø68 ø38.8 L* ø6 TSM480 TR480 25 10 ø4 L** 8 10 TSM480_g_dd_07_en_01 Fig. 4: Mechanical construction Item A: conical metal-to-metal process connection, with thread G1/2" (to be tightened with a torque of about 40 Nm) Item B: Tri-clamp 1" 1-1/2" process connection, also ISO 2852 DN 25/38 Item C: Dairy process connection DIN 11851 DN 25 Item D: Varivent D=68 mm process connection, for pipes DN 32/125 L and L* versions in 50, 100, 150, 200 mm L** version in 30 mm Weight Approximately from 80 to 600 g, mainly depending on process connection. Material Transmitter housing : stainless steel (SS). Components in contact with the process: SS 316L/1.4435, R a 0.8 µm. Adapter Designation Dimensions in mm Weld-in adapter for conical metal-to-metal connection, with G1/2" female thread. Material: SS 316L/1.4435. See Accessories, order code: 60021387. ø30 G1/2" ATT480_g_dd_09_xx_01 34 Terminals M12 plug-in connector (see Chap. Power supply). 6 Endress+Hauser

omnigrad T- TSM 480, TR 480 Human interface Display elements No display elements are present directly on the display. The measured value display, for example, can be called up using the ReadWin 2000 PC software. Operating elements No operating elements are present directly on the display. The temperature transmitter is configured via remote operation with the ReadWin 2000 PC software. Remote operation Configuration TSM470A configuration kit, can be configured using a PC operating program (ReadWin 2000). Interface PC-interface connecting cable TTL -/- RS232 with plug-in connection. Configurable parameters Measuring dimension ( C/ F), measuring ranges, failure mode, output signal (4...20 / 20...4 ma), offset, set tag number (8 characters), output simulation. Endress+Hauser 7

omnigrad T -TSM 480, TR 480 Certificates and approvals CE-Mark The measurement system fulfils the requirements demanded by the EU regulations. Endress+Hauser acknowledges successfull unit testing by adding the CE mark. Sanitary compatibility 3-A Authorization no. 1144 for the declaration of compliance with Standard 74-02. PED approval Other standards and guidelines The Pressure Equipment Directive (97/23/CE) is respected. As paragraph 2.1 of article 1 is not applicable to these types of instruments, the CE mark is not requested for the TR 480 destined for general use. EN 60529: Degrees of protection by housing (IP-Code) EN 61010: Safety requirements for electrical measurement, control and laboratory instrumentation. EN 61326 (IEC 1326): Electromagnetic compatibility (EMC requirements) NAMUR Standardization association for measurement and control in chemical and pharmaceutical industries. (www.namur.de) Further details Maintenance The Omnigrad M thermometers do not require any specific maintenance. Delivery time For small quantities (5 10 units) and standard options, between 2 and 5 days depending on the configuration required. 8 Endress+Hauser

omnigrad T- TSM 480, TR 480 Ordering information Product structure TSM 480- TSM 480 RTD Compact Thermometer Thermometer with M12 plug-in connector, integrated 2-wire 4...20 ma PCP transmitter, and hygienic process connection. Designed for food & beverage industry. Pt 100 4 wires; temperature range -50...200 C. Process connection A Conical metal-to-metal connection, with G1/2" B Tri-clamp flange 1" 1-1/2", ISO 2852 DN 25/38 C Dairy connection DIN 11851 DN 25 D Varivent D=68 mm for pipes DN 32/125 Neck length L (material stainless steel) 1 55 mm neck length Immersion length L A 30 mm immersion length L B 50 mm immersion length L C 100 mm immersion length L D 150 mm immersion length L E 200 mm immersion length L Probe diameter D and material A 6 mm = D, SS 316L/1.4435, Ra 0.8 µm Tip design S Straight tip R Tapered/reduced tip RTD type 3 1 Pt 100 TF class A Housing 0 No housing Terminal type and built-in transmitter BA M12 connector, transmitter range -50...100 C CA M12 connector, transmitter range -40...60 C DA M12 connector, transmitter range -30...60 C DB M12 connector, transmitter range -30...150 C DC M12 connector, transmitter range -30...70 C EA M12 connector, transmitter range -20...20 C EB M12 connector, transmitter range -20...60 C EN M12 connector, transmitter range -10...40 C FC M12 connector, transmitter range 0...50 C FE M12 connector, transmitter range 0...100 C FG M12 connector, transmitter range 0...150 C YY M12 connector, transmitter range to specify Additional options 0 Additional options not required TSM480-1 A 3 0 0 Order code (complete) Endress+Hauser 9

omnigrad T -TSM 480, TR 480 Ordering information Product structure TR480- TR 480 RTD Thermometer Thermometer with M12 plug-in connector, and with hygienic process connection. Designed for food & beverage industry. Pt 100 4 wires; temperature range -50...200 C. Process connection A Conical metal-to-metal connection, with G1/2" B Tri-clamp flange 1" 1-1/2", ISO 2852 DN 25/38 C Dairy connection DIN 11851 DN 25 D Varivent D=68 mm for pipes DN 32/125 Neck length L (material stainless steel) 1 25 mm neck length Immersion length L A 30 mm immersion length L B 50 mm immersion length L C 100 mm immersion length L D 150 mm immersion length L E 200 mm immersion length L Probe diameter D and material A 6 mm = D, SS 316L/1.4435, Ra 0.8 µm Tip design S Straight tip R Tapered/reduced tip RTD type 3 1 Pt 100 TF class A Housing 0 No housing Terminal type A M12 male output connector Additional options 0 Additional options not required TR480-1 A 3 0 A 0 Order code (complete) 10 Endress+Hauser

omnigrad T- TSM 480, TR 480 Accessories Order number Accessory 60021387 Weld-in adapter for conical metal-to-metal connection, with G1/2" female thread. Material: SS 316L/1.4435. TSM470A-VK Configuration kit: Setup program (ReadWin 2000) and PC interface cable (TTL/RS 232C) for configuring the compact thermometer. 51005148 Cable for sensor TSM 480, mith M12x1 plug-in connector, length = 5 m 51006327 M12x1 elbow plug ready for cable, IP67, Pg 7 Endress+Hauser 11

Supplementary documentation E+H Thermolab - Calibration certificates for industrial thermometers. RTD and thermocouples TI 236T/02/en Subject to modification Endress+Hauser Gmbh+Co. Instruments International P.O. Box 2222 D-79574 Weil am Rhein Germany Tel. (07621) 975-02 Tx 773926 Fax (07621) 975 345 http://www.endress.com info@ii.endress.com cl.01 TI 273T/02/en/08.03 60021667 FM+SGML6.0