Order Number : GETEC-C FCC Part 1 Test Report Number : GETEC-E Page 2 / 15 CONTENTS

Similar documents
FCC EVALUATION REPORT FOR CERTIFICATION

Model: M /800 MHz Mobile Radio

RF Exposure Assessment Report (FCC ID: 2AD8UAZRBRH1)

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042

Human Exposure Requirements for R&TTE and FCC Approval

RF-EXPOSURE ASSESSMENT REPORT

FCC RF Exposure Report

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

Test Summary Seite 2 von 26. Prüfbericht - Nr.: Test Report No. Page 2 of 26

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 7 CERTIFICATION TEST REPORT FOR g WIRELESS LAN + BLUETOOTH PCI-E MINI CARD

SAR REPORT. TEST STANDARDS: FCC Part 15 Subpart C Intentional Radiator. ARRIS Model Spectrum 110A Set Top Box With Bluetooth (DSS) and RF4CE (DTS)

ORT. Co., Ltd. Applicant FCC ID. Product. Model. June 26, Issue Date. TA Technology

TEST REPORT. Reference No... : WTS16S E FCC ID... : SJ8-UDR777HD. Applicant... : RDI Technology Shenzhen Co., Ltd.

Regulatory Authority of Bermuda report on

Test Report. Prepared for: Ubiquiti Networks, Inc. Model: RM5. Description: Rocket M5 FCC ID: SWX-R5M. FCC Part Date of Issue: April 24, 2015

Version TEST REPORT NO. DATE DESCRIPTION

Honeywell, Automation and Control Solutions

Medtronic MiniMed TEST REPORT FOR. GST3 Glucose Sensor Transmitter, MMT-7763A. Tested To The Following Standards:

Page 1 of 51 Report No.: T TEST REPORT FCC ID: 2AGJ5WAP-30. In Accordance with: FCC PART 15, SUBPART C : 2015 (Section 15.

Pico 900MHz 1W FHSS Module Model: p900 FCC ID: NS913P900. Applicant:

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

Honeywell, Automation and Control Solutions

Test Report Version. Test Report No. Date Description. DRTFCC Sep. 12, 2014 Initial issue

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. Bluetooth Remote Control for Video Set Top Box MODEL NUMBER: IPRC1000 FCC ID: 2ABTE-L3YJC9

FCC PART TEST REPORT. invoixa

FCC TEST REPORT. Table of Contents. FCC Measurement Report

TEST REPORT. Shenzhen, PRC.

Itron, Inc. TEST REPORT FOR. RF Telemetry Device Model: CCU100. Tested To The Following Standards:

For. Unit D16/F. should not use it to claim FCC ID: 2AAIN-MNGLOS

TEST SUMMARY. Prüfbericht - Nr.: Test Report No FIELD STRENGTH OF FUNDAMENTAL RESULT: Passed % BANDWIDTH RESULT: Passed

Intertek Testing Services ETL SEMKO

STC Test Report. Date : Page 1 of 13 No. : HM161169

FCC PART TEST REPORT. Zhejiang Flashforge 3D Technology CO., Ltd

TEST REPORT. Table of Contents

FCC PART 95 MEASUREMENT AND TEST REPORT HENAN ESHOW ELECTRONIC COMMERCE CO., LTD

Electric Imp, Inc. IMP003-FCC FCC :2014. Report # ELIM NVLAP Lab Code:

ELECTRICAL TESTING

FCC PART TEST REPORT. Weccan Industrial Limited

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: WXLRAMV Report No.: LCS E-03 FCC MPE TEST REPORT. 47 CFR FCC Part 2 2.

ENGINEERING TEST REPORT # C LSR Job #: C-2411 Compliance Testing of: RM186-SM

Report On. Radio Frequency Exposure Testing of the Winland Electronics, Inc. EnviroAlert Electronic Multi-Zone Environmental Alarm System

RF Exposure Report. Report No.: SA180206E02 FCC ID: 2ACH3UKAZA2A0. Test Model: UKAZA2A001. Received Date: Feb. 06, Test Date: Feb.

FCC PART TEST REPORT. ShenZhen Foscam Intelligent Technology Co.,Ltd

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

RF Exposure Evaluation Declaration

FCC PART & IC RSS GHz FHSS TEST REPORT

TABLE OF CONTENTS 1. GENERAL INFORMATION... 4

MAXIMUM PERMISSIBLE EXPOSURE ADDENDUM REPORT TO (Measurement)

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

FCC TEST REPORT. for. 47 CFR, Part 15, Subpart C. SPORTON International Inc.

Test Report. Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC

Palstar, Inc. EMC TEST REPORT FOR. HF LDMOS Amplifier Model: LA-1K. Tested To The Following Standard: FCC Part 97 Subpart D. Report No.

Calculated Radio Frequency Emissions Report. Cotuit Relo MA 414 Main Street, Cotuit, MA 02635

FCC PART 22H, PART 24E MEASUREMENT AND TEST REPORT. Chengdu Vantron Technology, Ltd.

FCC PART 15C IC RSS-210, ISSUE 7, JUNE 2007 TEST AND MEASUREMENT REPORT. SunPower Corporation

FCC Radio Test Report. Orpak Systems Ltd.

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

FCC Radio Test Report

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

Electromagnetic Compatibility Test Report

FCC TEST REPORT. Table of Contents. Report no. ETLE , Page 2 of 21

REPORT REVISION HISTORY...

FCC Verification TEST REPORT

Test Report. Applicant ASUSTeK COMPUTER INC. 4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan. Date of Receipt Jan. 28, Issued Date Mar.

FCC TEST REPORT FCC ID: PFNDMS2344UHDW

DATES OF TESTS: From 03/10/2014 to 20/10/2014 and 25/02/2015. Open area test site in Aunainville (28) - FRANCE. Page 2 out of 54

Contact person Date Reference Page Tomas Lennhager P03968-MPE 1 (2) Electronics

Radio Frequency Emissions Analysis Report Sprint Wireless Water Tank Facility

FCC Part 22H & 24E Measurement and Test Report

FCC Test Report. Report No.: AGC FE02 CLIENT : INNOVATIVE CONCEPTS AND DESIGN LLC. Attestation of Global Compliance (Shenzhen) Co., Ltd.

Test Report. Prepared for: Technologic Systems, Inc. Model: TS Description: Embedded Computer Board. Serial Number: N/A. FCC Part 15B Class A

FCC PART TEST REPORT. Hallmark Global LTD. dba HEXA.

Revision history. Revision Date of issue Test report No. Description KES-RF-14T0042 Initial

UL Japan, Inc. Head Office EMC Lab Asama-cho, Ise-shi, Mie-ken JAPAN Telephone : Facsimile :

TABLE OF CONTENTS. Report No.: SH E03 1. TEST RESULT CERTIFICATION...3

2200 Noll Drive Lancaster, PA Latitude: N 40º (NAD 83) Longitude: W 76º (NAD 83) 362 AMSL

FCC PART TEST REPORT BEYOND RADIO TECHNOLOGY LIMITED

FCC Test Report. Report No.: AGC FE08. Attestation of Global Compliance (Shenzhen) Co., Ltd

ROKU REMOTE MODEL: RC07

FCC Test Report. : Wireless Way Richmond, BC, V6V 3A4 Canada : 47 CFR FCC Part 27 Subpart L

RF EXPOSURE REPORT. For. Model: SVI Trade Name: BOSCH

Tested To The. and. Report. We strive to TESTING

FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR PCMCIA RFID READER CARD MODEL NUMBER: MPR6000 FCC ID: NTTWJMPR6XXX REPORT NUMBER: 04U2954-3

MAXIMUM PERMISSIBLE EXPOSURE STUDY

TEST REPORT NO. DATE DESCRIPTION

121 FCCTR_ TEST REPORT MAGNETI MARELLI S.P.A.

SAFETYTRAINING INFORMATION Your TYT ELECTRONICS CO.,LTD radio generates RF electromagnetic energy during transmit mode. This radio is designed for and

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

APPLICATION FOR VERIFICATION On behalf of MATRIX LIGHTING LTD. LED spot light. Model No.: 50-45GUS 50-45EUS Serial No.: E /02 E /02

FCC RADIO TEST REPORT FCC 47 CFR PART 15 SUBPART C

RF Exposure Evaluation Report

TEST REPORT WTN16S E 2AFOYL654UCNN

RF Exposure Report. Report No.: SA160920E06 R2 FCC ID: 2AD8UFW2QADPM01. Test Model: FW2QADPM01. Received Date: Sep. 20, Test Date: Oct.

RADIO REPORT FOR CERTIFICATION 47 CFR PART 15 SUBPART C (SECTION )

TEST REPORT FROM RFI GLOBAL SERVICES LTD

RF Exposure evaluation

FCC PART 15C & RSS 247 TEST REPORT

TRANSMITTER MODEL: KAS-2030M

EN 62479:2010 ASSESSMENT REPORT WIN CHANNEL ELECTRONICS (HK) CO., LTD

Transcription:

Test Report Number : GETEC-E3-17-046 Page 2 / 15 CONTENTS 1. GENERAL INFORMATION... 3 2. INTRODUCTION... 4 3. PRODUCT INFORMATION... 5 3.1 DESCRIPTION OF EUT... 5 3.2 DEFINITION OF MODELS... 5 3.3 SUPPORT EQUIPMENT / CABLES USED... 5 3.4 MODIFICATION ITEM(S)... 5 4. DESCRIPTION OF TESTS... 6 4.1 TEST CONDITION... 6 5. TEST EQUIPMENT USED... 6 6. TEST RESULT... 7 6.1 TEST SETUP... 7 6.2 MEASUREMENT PROCEDURE... 7 6.3 EQUIPMENT APPROVAL CONSIDERATIONS.... 8 6.4 ENVIRONMENTAL EVALUATION AND EXPOSURE LIMIT... 9 6.5 E AND H FIELD STRENGTH... 10 6.5.1 FIELD STRENGTH MEASURE VALUE AT 10 CM FROM THE EDGES SURROUNDING THE EUT... 10 7. PHOTOGRAPHS... 11 7.1 TEST PHOTOGRAPHS... 11

Test Report Number : GETEC-E3-17-046 Page 3 / 15 Scope: Measurement and determination of electromagnetic emissions (EME) of radio frequency devices including intentional and / or unintentional radiators for compliance with technical rules and regulations of the Federal Communications Commission. 1. General Information Applicant: LG Electronics USA. Applicant Address: 1000 Sylvan Avenue, Englewood Cliffs New Jersey United States 07632 Manufacturer: LG Electronics Inc. Manufacturer Address: 170, Sungsanpaechong-ro, Seongsan-gu, Changwon-si, Gyeongsangnam-do, 642-711, Korea Contact Person: Bogeun Lee / Research Engineer Tel. Number: +82-55-260-3966 FCC ID. BEJE18MRE07 EUT Type Refrigerator Model Name SKSCR3001P Rule Part(s) FCC Part 1 Type of Authority Certification Test Procedure(s) FCC Part 1, Subpart I, section 1.1310 and KDB 680106 D01 V02 Dates of Test Sep. 02, 2017 Place of Test GUMI UNIVERSITY EMC CENTER (FCC Test Firm Registration Number: 269701) 37 Yaeun-ro, Gumi-si, Gyeongsangbuk-do, 730-711, Republic of Korea. Test Report Number GETEC-E3-17-046 Dates of Issue Sep. 08, 2017

Test Report Number : GETEC-E3-17-046 Page 4 / 15 2. Introduction The measurement procedure described in American National Standard for Methods of Measurement of Radio-Nose Emissions From Low-Voltage Electrical and Electronic Equipment in the Range of 9 khz to 40 GHz (ANSI C63.4-2014) was used in determining radiated and conducted emissions emanating from LG Electronics USA. Refrigerator (Model name: SKSCR3001P) These measurement tests were conducted at GUMI UNIVERSITY EMC CENTER. The site address is 37 Yaeun-ro, Gumi-si, Gyeongsangbuk-do, 730-711, Gyeongnam 641-713, Korea This test site is one of the highest point of GUMI UNIVERSITY at about 200 kilometers away from Seoul city and 40 kilometers away from Daegu city. It is located in the valley surrounded by mountains in all directions where ambient radio signal conditions are quiet and a favorable area to measure the radio frequency interference on open field test site for the computing and ISM devices manufactures. The detailed description of the measurement facility was found to be in compliance with the requirements of 2.948 according to ANSI C63.4 (2014) GUMI UNIVERSITY EMC CENTER 37 Yaeun-ro, Gumi-si, Gyeongsangbuk-do, 730-711, Gyeongnam 641-713, Korea Tel: +82-54-440-1195 Fax: +82-54-440-1199 Fig 1. The map above shows the GUMI UNIVERSITY in vicinity area.

Test Report Number : GETEC-E3-17-046 Page 5 / 15 3. Product Information 3.1 Description of EUT The Equipment under Test (EUT) is the LG Electronics USA. Refrigerator (Model Name: SKSCR3001P). Type of Equipment Refrigerator Model Name SKSCR3001P Serial Number Prototype RF Frequency 330 khz ~ 370 khz External connector DC input 1 EA Rated Voltage Input : AC 115 V, 60 Hz ( Wireless Power Transmitter input voltage: DC 12 V) Output Electricity Power Less than 3 W Size(W x H x T) 29 3/4 (W) x23 3/4 (D) x83 1/2 (H) inch (Wireless Power Transmitter module :50 (mm) x 35 (mm) x 1.0 (mm)) 3.2 Definition of models - None. 3.3 Support Equipment / Cables used 3.3.1 Used Support Equipment Description Manufacturer Model Name S/N & FCC ID. None - - See Appendix E Test Setup Photographs for actual system test set-up S/N: - FCC ID.: - 3.3.2 System configuration Description Manufacturer Model Name S/N & FCC ID. None. - - S/N: -. FCC ID.: -. 3.3.3 Used Cable(s) Cable Name Condition Description Power cable Connected to the EUT and AC power 2.20 m Unshielded. 3.4 Modification Item(s) -. None

Test Report Number : GETEC-E3-17-046 Page 6 / 15 4. Description of tests 4.1 Test Condition The EUT was installed, arranged and operated in a manner that is most representative of equipment as typically used. The measurements were carried out while varying operating modes and cable positions within typically arrangement to determine maximum emission level. The representative and worst test mode(s) were noted in the test report. Test Voltage / Frequency: AC 115V, 60 Hz( Wireless Power Transfer Device supplied DC 12 V) Operating condition during the test(s) : This device has been tested in the configurations of charging mode Charging Current Support Equipment Comment 1 000 ma Refrigerator Shelf RX module 5. Test Equipment used Model Name Manufacturer Description Serial Number Due to Calibration - ELT-400 Narda Safety Test EMF Tester J-0005 Sep. 09, 2018 Solutions GmbH - HI-6105 ETS LINDGREN Electric field Probe 203871 Dec. 13, 2017 All test equipment used is calibrated on a regular basis.

Test Report Number : GETEC-E3-17-046 Page 7 / 15 6. Test Result 6.1 Test Setup Side 1 1 Side 5 5 Side 4 4 Side 2 Side 6 6 Side 3 3 6.2 Measurement Procedure The RF exposure test was performed on 360 degree turn table in anechoic chamber. The measurement probe was placed at test distance ( 10 cm ) which is between the edge of the charger and the geometric center of probe. The turn table was rotated 360 degree to search of highest strength. The highest emission level was recorded and compared with limit as soon as measurement of each points (Side 1 ~ 6) were completed. The EUT were measured according to the dictates of KDB 680106 D01v02.

Test Report Number : GETEC-E3-17-046 Page 8 / 15 6.3 Equipment Approval Considerations. The EUT does with item 5.2 of KDB 680106 D01v02 a) Power transfer frequency is less that 1 MHz - Power transfer(main Carrier) frequency is fixed between 330 khz ~ 370 khz b) Output power from each primary coil is less than 5 watts. - The maximum field strength of fundamental : 60.81 dbµv/m at 3 m. The EIRP calculation is reference to KDB 789033 EIRP[dBm] = E[dBµV/m]+20log(d[meters]) -104.77, d = 3 m 60.81 dbµv/m 95.2 = -34.39 dbm EIRP The output power from primary coil is 0.000 363 mw c) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils - The system is consists of single primary and secondary coils. d) Client device is inserted in or placed directly in contact with the transmitter - Client device(receiver) is placed by the transmitter with a less than 10 mm gap. Refer to following photo. e) The maximum coupling surface area of the transmit(charging) device is between 60 cm 2 and 400 cm 2 - The shape of primary and secondary coils are same and the they are center-aligned. Maximum coupling surface area of transmitter is under 20cm 2 f) Aggregate leakage fields at 10 cm surrounding the device from all simultaneous transmitting coils are demonstrated to be less than 30% of the MPE limit. - Aggregate leakage level of the system in normal operating condition at 10cm surrounding the device is under 15% of MPE limit (<0.2A/m) - 0.212 A/m (maximum measure value) < 0.486 Am (30% MPE limit)

Test Report Number : GETEC-E3-17-046 Page 9 / 15 6.4 Environmental evaluation and exposure limit * according to FCC CFR 47 part 1, 1.1307(b), 1.1310 1.1310 : The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of FCC part 2.1093 of this chapter Table 1 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) Frequency Range (MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mw/cm 2 ) Average Time (minutes) (A) Limits for Occupational /Control Exposures 0.3 3.0 614 1.63 *(100) 6 3.0 30 1842/f 4.89/f *(900/f 2 ) 6 30 300 61.4 6.163 1.0 6 300 1 500 f/300 6 1 500 100 000 5 6 (B) Limits for General Population / Uncontrol Exposures 0.3 1.34 614 1.63 *(100) 30 1.34 30 824/f 2.19 *(180/f 2 ) 30 30 300 27.5 0.073 0.2 30 300 1 500 f/1 500 30 1 500 100 000 1.0 30 F=frequency in MHz * = Plane wave equivalent power density Note 1 to Table 1: Occupational/controlled limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when an individual is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. Note 2 to Table 1: General population/uncontrolled exposures apply in situations in which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or can not exercise control over their exposure.

Test Report Number : GETEC-E3-17-046 Page 10 / 15 6.5 E and H field strength Temperature : 22.4 Relative Humidity : 58.9 % R.H. Air pressure : 100.4 kpa Test mode : Continuous Power transmitting mode 6.5.1 Field Strength measure value at 10 cm from the edges surrounding the EUT Electric Field Strength Test Position Probe Measure Result(V/m) Limit(V/m) 30 % Limit(V/m) Side 1 7.76 614 184.2 Side 2 5.15 614 184.2 Side 3 5.82 614 184.2 Side 4 9.15 614 184.2 Side 5 6.82 614 184.2 Magnetic Field Strength Test Position Probe Measure Result(A/m) Limit(A/m) 30 % Limit(A/m) Side 1 0.099 1.63 0.489 Side 2 0.092 1.63 0.489 Side 3 0.096 1.63 0.489 Side 4 0.103 1.63 0.489 Side 5 0.101 1.63 0.489

Test Report Number : GETEC-E3-17-046 Page 11 / 15 7. Photographs 7.1 Test Photographs Test model No.: SKSCR3001P Test with full load Side 1 < Electric field > < Magnetic field >

Test Report Number : GETEC-E3-17-046 Page 12 / 15 Side 2 < Electric field > < Magnetic field >

Test Report Number : GETEC-E3-17-046 Page 13 / 15 Side 3 < Electric field > < Magnetic field >

Test Report Number : GETEC-E3-17-046 Page 14 / 15 Side 4 < Electric field > < Magnetic field >