A COMPACT, 1-MV, 6-kA RADIOGRAPHY SOURCE WITH A ONE- METER EXTENSION AND RIGHT-ANGLE BEND

Similar documents
Adaptation of ASTERIX to Positive Polarity for 2 to 4-MV Rod-Pinch Diode Experiments and Diode Electrical Analysis *

Conversion of Mercury (a 2-TW Inductive Voltage Adder) to Positive Polarity

ANALYSIS OF SWITCH PERFORMANCE ON THE MERCURY PULSED- POWER GENERATOR *

-6 MV VACUUM VOLTMETER DEVELOPMENT

TRANSMISSION LINE AND ELECTROMAGNETIC MODELS OF THE MYKONOS-2 ACCELERATOR*

EVAUATION OF THE ROD-PINCH DIODE AS A HIGH-RESOLUTION SOURCE FOR FLASHRADIOGRAPHY AT 2 TO 4 MV *

8.2. Washington, D. C delivered 65 kj into a matched load with 63 ns FWHM. Peak power was about 1 TW.

UPGRADES TO THE DARHT SECOND AXIS INDUCTION CELLS

ANALYSIS OF A PULSED CORONA CIRCUIT

COMPACT FLASH X-RAY UNITS. Abstract

BREMSSTRAHLUNG DIODE PERFORMANCE ON MERCURY MIVA

PULSED POWER SWITCHING OF 4H-SIC VERTICAL D-MOSFET AND DEVICE CHARACTERIZATION

INVESTIGATION OF A HIGH VOLTAGE, HIGH FREQUENCY POWER CONDITIONING SYSTEM FOR USE WITH FLUX COMPRESSION GENERATORS

FLASH X-RAY (FXR) ACCELERATOR OPTIMIZATION BEAM-INDUCED VOLTAGE SIMULATION AND TDR MEASUREMENTS *

Pulse Power Performance of the Cygnus 1 and 2 Radiographic Sources

PULSED BREAKDOWN CHARACTERISTICS OF HELIUM IN PARTIAL VACUUM IN KHZ RANGE

DEVELOPMENT OF AN ULTRA-COMPACT EXPLOSIVELY DRIVEN MAGNETIC FLUX COMPRESSION GENERATOR SYSTEM

DEVELOPMENT OF THE SELF MAGNETIC PINCH DIODE AS A HIGH BRIGHTNESS RADIOGRAPHIC SOURCE

A NEW BROADBAND PULSED HIGH VOLTAGE MONITOR *

OPTICAL EMISSION CHARACTERISTICS OF HELIUM BREAKDOWN AT PARTIAL VACUUM FOR POINT TO PLANE GEOMETRY

IB2-1 HIGH AVERAGE POWER TESTS OF A CROSSED-FIELD CLOSING SWITCH>:< Robin J. Harvey and Robert W. Holly

RAVEN, A 5 kj, 1.5 MV REPETITIVE PULSER* G. J. Rohwein Sandia National Laboratories Albuquerque, New Mexico 87185

PERFORMANCE OF A 10 KV, 625 KA, 85 KJ ENERGY DISCHARGE MODULE UTILIZING A SOLID DIELECTRIC SWITCH.*

DEVELOPMENT OF STITCH SUPER-GTOS FOR PULSED POWER

Investigation of a Forward Looking Conformal Broadband Antenna for Airborne Wide Area Surveillance

Digital Radiography and X-ray Computed Tomography Slice Inspection of an Aluminum Truss Section

REPORT DOCUMENTATION PAGE

FLASH X-RAY (FXR) ACCELERATOR OPTIMIZATION INJECTOR VOLTAGE-VARIATION COMPENSATION VIA BEAM-INDUCED GAP VOLTAGE *

Development of a charged-particle accumulator using an RF confinement method FA

An experimental system was constructed in which

Research on High Power Railguns at the Naval Research Laboratory

** Present Address: Maxwell Technologies, San Diego, CA CONDUCTION TIME/CURRENT LIMITATION ON THE DEFENSE SPECIAL WEAPONS AGENCY DECADE MODULE 1*

Thermal Simulation of Switching Pulses in an Insulated Gate Bipolar Transistor (IGBT) Power Module

ACCELERATOR FAST KICKER R&D WITH ULTRA COMPACT 50MVA NANO-SECOND FID PULSE GENERATOR

SILICON CARBIDE FOR NEXT GENERATION VEHICULAR POWER CONVERTERS. John Kajs SAIC August UNCLASSIFIED: Dist A. Approved for public release

PHASING CAPABILITY. Abstract ARRAY. level. up to. to 12 GW. device s outpu antenna array. Electric Mode. same physical dimensions.

Thermal Simulation of a Silicon Carbide (SiC) Insulated-Gate Bipolar Transistor (IGBT) in Continuous Switching Mode

EXPERIMENTS ON A HIGH-VACUUM, HIGH-ELECTRIC FIELD STRESS PULSED POWER INTERFACE

David L. Lockwood. Ralph I. McNall Jr., Richard F. Whitbeck Thermal Technology Laboratory, Inc., Buffalo, N.Y.

DESIGN OPTIONS FOR A PULSED-POWER UPGRADE OF THE Z ACCELERATOR *

EFFECTS OF ELECTROMAGNETIC PULSES ON A MULTILAYERED SYSTEM

ELECTRON-BEAM TRANSPORT STUDIES FOR RADIOGRAPHIC APPLICATIONS

HIGH TEMPERATURE (250 C) SIC POWER MODULE FOR MILITARY HYBRID ELECTRICAL VEHICLE APPLICATIONS

Underwater Intelligent Sensor Protection System

9.4 A HIGH CURRENT PULSER FOR EXPERIMENT 11225, "NEUTRINO ELECTRON ELASTIC SCATTERING" C. Dalton, G. Krausse, and J. Sarjeant

Reduced Power Laser Designation Systems

COM DEV AIS Initiative. TEXAS II Meeting September 03, 2008 Ian D Souza

Evanescent Acoustic Wave Scattering by Targets and Diffraction by Ripples

Fuse and Load Testing With Mid-Sized, High Energy Density Flux Compression Generators

Modeling of Ionospheric Refraction of UHF Radar Signals at High Latitudes

Signal Processing Architectures for Ultra-Wideband Wide-Angle Synthetic Aperture Radar Applications

Active Denial Array. Directed Energy. Technology, Modeling, and Assessment

EFFECT OF TRANSFORMER LEAKAGE INDUCTANCE ON THE THREE PHASE CAPACITIVE INPUT RECTIFIER

REPORT DOCUMENTATION PAGE

ULTRA FAST, HIGH REP RATE, HIGH VOLTAGE SPARK GAP PULSER

Experimental Observation of RF Radiation Generated by an Explosively Driven Voltage Generator

DEVELOPMENT OF A l!j.s, 40Hz, X-RAY SOURCE*

AFRL-RX-WP-TP

Robotics and Artificial Intelligence. Rodney Brooks Director, MIT Computer Science and Artificial Intelligence Laboratory CTO, irobot Corp

Strategic Technical Baselines for UK Nuclear Clean-up Programmes. Presented by Brian Ensor Strategy and Engineering Manager NDA

Simulation Comparisons of Three Different Meander Line Dipoles

CHARACTERIZATION OF PASCHEN CURVE ANOMOLIES AT HIGH P*D VALUES

EVALUATION OF RESISTORS FOR TRANSIENT HIGH-VOLTAGE APPLICATIONS

MINIATURIZED ANTENNAS FOR COMPACT SOLDIER COMBAT SYSTEMS

Loop-Dipole Antenna Modeling using the FEKO code

Lattice Spacing Effect on Scan Loss for Bat-Wing Phased Array Antennas

Innovative 3D Visualization of Electro-optic Data for MCM

Durable Aircraft. February 7, 2011

ANTENNA DEVELOPMENT FOR MULTIFUNCTIONAL ARMOR APPLICATIONS USING EMBEDDED SPIN-TORQUE NANO-OSCILLATOR (STNO) AS A MICROWAVE DETECTOR

SA Joint USN/USMC Spectrum Conference. Gerry Fitzgerald. Organization: G036 Project: 0710V250-A1

August 9, Attached please find the progress report for ONR Contract N C-0230 for the period of January 20, 2015 to April 19, 2015.

0.9Vo II. SYNTHESIZER APPROACH

SILICON DIODE EVALUATED AS RECTIFIER FOR WIDE-PULSE SWITCHING APPLICATIONS

Report Documentation Page

REGULATED CAPACITOR CHARGING CIRCUIT USING A HIGH REACTANCE TRANSFORMER 1

CYGNUS PERFORMANCE IN SUBCRITICAL EXPERIMENTS

Report Documentation Page

Sea Surface Backscatter Distortions of Scanning Radar Altimeter Ocean Wave Measurements

INTEGRATIVE MIGRATORY BIRD MANAGEMENT ON MILITARY BASES: THE ROLE OF RADAR ORNITHOLOGY

Challenges in Imaging, Sensors, and Signal Processing

Best Practices for Technology Transition. Technology Maturity Conference September 12, 2007

Advances in SiC Power Technology

0.18 μm CMOS Fully Differential CTIA for a 32x16 ROIC for 3D Ladar Imaging Systems

[Research Title]: Electro-spun fine fibers of shape memory polymer used as an engineering part. Contractor (PI): Hirohisa Tamagawa

U.S. Army Training and Doctrine Command (TRADOC) Virtual World Project

Marine~4 Pbscl~ PHYS(O laboratory -Ip ISUt

A Multi-Use Low-Cost, Integrated, Conductivity/Temperature Sensor

AUVFEST 05 Quick Look Report of NPS Activities

Automatic Payload Deployment System (APDS)

THE DET CURVE IN ASSESSMENT OF DETECTION TASK PERFORMANCE

ULTRASTABLE OSCILLATORS FOR SPACE APPLICATIONS

POSTPRINT UNITED STATES AIR FORCE RESEARCH ON AIRFIELD PAVEMENT REPAIRS USING PRECAST PORTLAND CEMENT CONCRETE (PCC) SLABS (BRIEFING SLIDES)

Radar Detection of Marine Mammals

USAARL NUH-60FS Acoustic Characterization

REPORT DOCUMENTATION PAGE. Thermal transport and measurement of specific heat in artificially sculpted nanostructures. Dr. Mandar Madhokar Deshmukh

MULTI-KILOVOLT SOLID-STATE PICOSECOND SWITCH STUDIES *

CFDTD Solution For Large Waveguide Slot Arrays

"OPTIMAL SIMULATION TECHNIQUES FOR DISTRIBUTED ENERGY STORE RAILGUNS WITH SOLID STATE SWITCHES"

Modeling an HF NVIS Towel-Bar Antenna on a Coast Guard Patrol Boat A Comparison of WIPL-D and the Numerical Electromagnetics Code (NEC)

VHF/UHF Imagery of Targets, Decoys, and Trees

Transcription:

A COMPACT, 1-MV, 6-kA RADIOGRAPHY SOURCE WITH A ONE- METER EXTENSION AND RIGHT-ANGLE BEND B. M. Huhman ξ a, R. J. Allen, G. Cooperstein, D. Mosher b, J.W. Schumer, F.C. Young b Plasma Physics Division, Naval Research Laboratory Washington, DC 20375 USA Abstract The Hybrid Radiation Source (HRS) is a compact pulsed power generator consisting of a commercial flash x-ray system that has been retrofitted with a custom frontend assembly, replacing a sealed glass tube 1. A new high impedance (~120 Ohm) space-charge-limited (SCL) diode was fielded on the HRS. This diode produces a ~ 1.6 mm diameter x-ray spot suitable for high-resolution radiography 2. This system has been modified by extending the diode from the generator with a one-meterlong vacuum transmission line. Also, the anode has been oriented to point perpendicular to the transmission-line axis. The extension and re-direction allow for the placement of the high-yield, small-spot-size, HRS radiographic source in previously unreachable locations. Parameters such as voltage, current, and source size have been measured and analyzed, allowing for optimization of the radiographic source. Discussion will also include circuit diagrams, simulation models, and diagnostic traces. The modifications to the base unit allow for reduced spot size, increased dose, and allow for an easily replaceable anode. New hardware on the device includes a field shaper, stacked-ring insulator, B-dot ring, and turbo vacuum pump. A. Vacuum Extension Hardware A one-meter extension was added to the end of the unit, as shown in Figure 2. The outer conductor consists of two ISO-63 tubes, terminated in a shorter ISO-63 tube with two small windows 180 apart. The main advantage of the extension is to distance the diode from the generator, which can be useful in explosive experiments. If the extension were damaged, it is simple to repair, compared with a damaged generator which can be rather expensive and time consuming. I. RADIOGRAPHY SOURCE AND DIAGNOSTICS The HRS uses a 1-MV Pulserad base and a scandiflashlike tube, as shown in Figure 1. Figure 1. HRS radiography source system diagram. Figure 2. One-meter vacuum extension isolates generator from diode. The main portion of the extension has a 3.8 O.D. and a 0.5 I.D, therefore the vacuum impedance is 122 Ω. At 1- MV, the field on the outer conductor is ~100 kv/cm, close to the emission threshold. Care was taken to minimize field enhancement on the outer conductor. Sharp edges were removed, and extra clamps were used on the tube joints to ensure good current contact. Modeling and measurements show that the diode impedance decreases from ~160 Ω to 60 Ω during the x- ray pulse, and is ~100 Ω at the x-ray peak. Circuit modeling also shows that this extension has very little effect on the diode operation. B. Center Conductor Extension Several types of metal tubes were tested to minimize center conductor droop. The first material tested was Work supported by Los Alamos National Laboratory ξ email: brett.huhman@nrl.navy.mil a Formerly L-3 Communications Titan Group, Reston VA 20190 b L-3 Communications Titan Group, Reston, VA 20190 1-4244-0914-4/07/$25.00 2007 IEEE. 788

Report Documentation Page Form Approved OMB No. 0704-0188 Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to a penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE JUN 2007 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE A Compact, 1-Mv, 6-Ka Radiography Source With A Onemeter Extension And Right-Angle Bend 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Plasma Physics Division, Naval Research Laboratory Washington, DC 20375 USA 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR S ACRONYM(S) 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release, distribution unlimited 11. SPONSOR/MONITOR S REPORT NUMBER(S) 13. SUPPLEMENTARY NOTES See also ADM002371. 2013 IEEE Pulsed Power Conference, Digest of Technical Papers 1976-2013, and Abstracts of the 2013 IEEE International Conference on Plasma Science. IEEE International Pulsed Power Conference (19th). Held in San Francisco, CA on 16-21 June 2013., The original document contains color images. 14. ABSTRACT The Hybrid Radiation Source (HRS) is a compact pulsed power generator consisting of a commercial flash x-ray system that has been retrofitted with a custom frontend assembly, replacing a sealed glass tube1. A new high impedance (~120 Ohm) space-charge-limited (SCL) diode was fielded on the HRS. This diode produces a ~ 1.6 mm diameter x-ray spot suitable for high-resolution radiography2. This system has been modified by extending the diode from the generator with a one-meterlong vacuum transmission line. Also, the anode has been oriented to point perpendicular to the transmission-line axis. The extension and re-direction allow for the placement of the high-yield, small-spot-size, HRS radiographic source in previously unreachable locations. Parameters such as voltage, current, and source size have been measured and analyzed, allowing for optimization of the radiographic source. Discussion will also include circuit diagrams, simulation models, and diagnostic traces. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT SAR a. REPORT unclassified b. ABSTRACT unclassified c. THIS PAGE unclassified 18. NUMBER OF PAGES 6 19a. NAME OF RESPONSIBLE PERSON Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18

aluminum, in the form of both tubes and rods. Both types drooped more than 2 cm over a one-meter span, which is too much to be useful. A solid stainless steel rod was too heavy, while hollow stainless steel tubes with a 3.81-mm wall thickness drooped less than 2.0 mm for a one-meter span. The final center conductor design consists of two parts, as shown in Figure 3. The first part is the aforementioned hollow stainless steel tube. A 6.35-mm diameter aluminum tube fits inside the larger rod and serves as an adjustable extension to provide a custom fit to the diode. Since the smaller tube is only extended 130 mm, it is a short enough distance that any droop can be corrected with set screws in the junction between the two rods. The aluminum tube has threads on the end for an anode holder to be mounted to the center conductor. The anode holder has a hole drilled on the center line for anode placement. D. Electrical and Radiation Diagnostics A number of electrical and radiation diagnostics were used to characterize the HRS source, as shown in Figure 5. The diode current was measured using two B-dot monitors mounted on a ring around the center conductor. The diode voltage was measured using the built-in belly band capacitive voltage monitor. The radiation dose was measured with a pocket dosimeter located 10 off axis at one meter. The radiation pulse shape was measured with a Si PIN diode positioned next to the dosimeter. Figure 3. Main center conductor is made from a stainless steel tube with an inner adjustable extension tube. C. Right Angle Modification A modification was made to the one-meter extension to allow the diode to be 90 from the center conductor axis. As shown in Figure 4, the anode holder has a hole that holds the anode at a right angle, and a set screw secures the anode in place. The anode can be moved forward or back to adjust the AK gap as necessary. Additionally, the diode can be rotated around the center axis 360 to accommodate the radiographic target. Precise 2-D alignment of the anode to the cathode is made by removing the flanges on both ends of the vacuum tee. Figure 4. Right-angle bend with anode and cathode detail. Figure 5. HRS with one-meter extension and diagnostics. The source size was measured with both on-axis and off-axis diagnostics. A tungsten 2-D rolled-edge was used to measure the on-axis source size. The rolled-edge was placed on axis 30 cm from the anode tip, and a digital image plate was located 120 cm from the anode tip. The off-axis source size was measured using a pinhole camera with a 0.25-mm diameter pinhole. The pinhole was 20 cm from the anode, and 20.5 cm from the digital image plate. Calibration of the B-dots was performed on a separate test stand, by sending a pulse through a pre-calibrated shunt. Once the B-dots were calibrated, they were installed in the B-dot ring and mounted on the front end of the HRS. The voltage monitor was calibrated using a dummy load resistor, as shown in Figure 6, which was installed as the center conductor. The current from the B- dots was averaged and used with the dummy load resistance to calibrate the voltage monitor. A slight inductance and droop correction was added to the voltage monitor to determine the voltage to the load. Asymmetric power flow due to the right angle extension was minimized by the large inductance of the anode and the cylindrical shape of the cathode. 789

- No Extension - Extension - With bend Figure 6. Dummy load resistor for voltage monitor calibration. II. HRS MODES OF OPERATION The HRS was operated in three different modes: no extension, one-meter straight extension, and one-meter extension with right angle. The electrical and radiation diagnostics were compared for these three modes. Figure 8. Current traces from B-dot ring for all three cases. The radiation traces, shown in Figure 9, also show similar shapes. The modes without the extension and with the right angle both have slightly higher yield than with the one-meter straight extension. - No Extension - Extension - With bend A. Electrical Measurements The voltage, current, and radiation are very similar for all three modes of operation. As shown in Figure 7, the peak voltage is nearly 1 MV with the extension and with a one-meter straight extension, and only slightly lower at 900 kv with the right-angle. - No Extension - Extension - With bend Figure 9. Radiation traces from the Si PIN diode 10 off axis at one meter for all three modes. B. Pinhole Camera Imaging Side-viewing pinhole camera images were compared for the three modes of operation. The pinhole camera images are shown in Figure 10. For all three modes, the images are virtually identical. Figure 7. Voltage traces for modes with no extension, straight extension, and extension with right-angle bend. The current traces, shown in Figure 8, peak at 5 to 6.5 ka for all three modes, with some slight time differences on the peaks. 790

Figure 10. Side-viewing pinhole camera images. Figure 12. Rolled-edge image-plate scan with horizontaland vertical-band areas highlighted. Axial intensity distributions along the anode rod are shown in Figure 11. The axial emission is unchanged by adding the extension and the right-angle bend. Figure 13. Horizontal and vertical edge-spread measurements from image plate. Figure 11. Axial intensity distributions from pinhole camera images. C. Source Size Comparisons The horizontal and vertical edge spreads are extracted from scans of the rolled-edge image-plates and are used to determine the on-axis source size. A typical scan is shown in Figure 12, and edge spreads from the horizontal and vertical bands are shown in Figure 13. The derivative of the edge spread is the line spread, which is used to calculate the source size. A magnification correction is applied to give the line spread at the source. A comparison of the source sizes for all three modes is shown in Figure 14. The average of the horizontal and vertical line spreads is used for these comparisons. The values of the source sizes listed in Table 1 indicate that the size is unchanged by adding the one-meter extension and the right-angle bend. 791

The electron density, ion density, and current-enclosed contours plots are shown in Figure 16. They are representative of steady-state behavior in the diode at 1 MV for a case in which the electrons are emitted from only the angled portion and ions are emitted from only the tapered region of the anode. Electrons follow potential field lines while the ions stream radially outward; it is conjectured that the large ion-space-charge near the surface of the anode is what allows the enhancement of the electron current above that expected simply from bipolar flow. Figure 14. Source-size comparisons based on line spreads. Table 1. Source Size Measurements Horizontal (mm) Vertical (mm) With Right-Angle Bend 1.69 1.61 Extension Only 1.61 1.61 Without Extension 1.57 1.72 All spot sizes use AWE definition D. PIC Simulations using LSP Particle-in-cell (PIC) simulations using LSP [3] were performed to help understand the influence of ion spacecharge on the diode impedance behavior. Figure 15 shows a diagram of the model used for the simulations. Figure 16. Results of PIC simulations with electron density, ion density, and current enclosed. Figure 17 summarizes a series of PIC simulations with different AK-gaps, run to steady-state behavior at 1-MV. Figure 15. Model used for PIC simulation using LSP. Figure 17. Gap scan using PIC with steady-state voltage at 1-MV. 792

The scan shows semi-classical impedance behavior, with relatively-stable ion currents over a large impedance variation. Note that an impedance variation from 50 Ω to 200 Ω only has a 3% variation in the electron current fraction. With an AK gap of less than 2 mm, the diode with show cylindrical impedance behavior. An AK gap of greater than 3 mm will tend to show a point-plane diode impedance behavior. III. SUMMARY A one-meter extension and right-angle bend have been successfully fielded on the HRS. The voltage, current, and radiation traces are similar with and without the onemeter extension and the right-angle bend. Side-viewing pinhole camera images show similar axial intensity distributions. Rolled-edge measurements show that the source size is unchanged by adding the extension and the right-angle bend. PIC simulations show semi-classical impedance behavior, with relatively-stable ion currents over a large impedance variation. Ion space charge enhances electron current by more than five times. Future work on the HRS will focus on obtaining smaller source sizes. The current anode diameter is 1.6 mm, with a 1.6-mm source size. Obtaining a size of less than 1.0 mm may be possible with smaller diameter rods. IV. REFERENCES [1] R. J. Allen, G. Cooperstein, F.C. Young, J.W. Schumer, D.D. Hinshelwood, D. Mosher, D. Holmberg, S.E. Michell, Characterization and Optimization of a Compact, 1-MV, 6-kA Radiography Source, 14th International Pulsed Power Conference Digest of Technical Papers, June 15-18, 2003, pp. 883-886. [2] G. Cooperstein, R.J. Allen, R.J. Commisso, B.M. Huhman, D. Mosher, P.F. Ottinger, J.W. Schumer, S.B. Swanekamp, F.C. Young, A High-Impedance, High Resolution, 1-MV Radiography Diode, 33rd IEEE International Conference on Plasma Science Conference Records - Abstracts, June 4-8, 2006, p. 283. [3] LSP is a software product of ATK Mission Research, Albuquerque, NM 87110. 793