MG2 Series. Corrosion Thickness Gages. MG2, MG2-XT, and MG2-DL. MG2-xt and MG2-DL are. B-scan and optional Live A-scan with Waveform Adjust

Similar documents
Advanced Test Equipment Rentals ATEC (2832)

Ultrasonic Precision Thickness Gages

45MG Ultrasonic Thickness Gage

Ultrasonic NDT Gauges 1.

NDT Supply.com 7952 Nieman Road Lenexa, KS USA

Ultrasonic Bolt Load Measurement

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic thickness measurement

Applications Features

1510A PRECISION SIGNAL SIMULATOR

INTRODUCTION. Strong Performance: High resolution and penetration, achieving precise flaw detection

ULTRASONIC CONCRETE TESTING EQUIPMENT

Model R7900. Instruction Manual. Ultrasonic Thickness Gauge. reedinstruments. www. com

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

PosiTector 200. Ultrasonic Coating Thickness Gage. Standard and Advanced. INSTRUCTION MANUAL v Simple. Durable. Accurate.

BondMaster 600 Intuitive Bond Testing

EMAT Application on Incoloy furnace Tubing Ramamohan Reddy M (ASNT Level III UT, PCN Level III UT,PAUT&TOFD)

Insulation Testers and Earth Ground Testers

Technical specification FLUXUS F401 H2O

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

Professional Dual-Laser Infrared Thermometer with 50:1 Distance-to-Sight Ratio, Data Logging, USB Output, Single Type K Input, and Temperature Alarm

T R X I I TRX-II - 9/98

UT Thickness Gauge DC Instruction Manual

Digital Ultrasonic Flaw Detector

Weld Checkers RESISTANCE WELDING

Model CG100ABDL, CG100BDL & CG100B. Corrosion Gauge. Operating Instructions

ULTRASONIC FLAW DETECTOR +TOFD VERSION. CE MARKING EN Compliant

Digital Ultrasonic Flaw Detector

MIT400 CAT IV Industrial Insulation Testers

THE USE OF MAGNETOSTRICTIVE EMAT TRANSDUCERS ON OXIDE SCALED BOILER TUBES

MIT400 CAT IV Industrial Insulation Testers

Model Sono-Trak Transit Time

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

UltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related

CABLE TESTER. Models CA7024, CA7026 & CA7028. Call toll free (800) or visit

Model FD700DL+ & FD700+ Corrosion and Flaw Gauge. Operating Instructions

UNIVERSAL ULTRASONIC FLAW DETECTOR UD4-76. TOFD version.

spectro-guide Total Appearance Control color and gloss in one unit Easy to use and handle Solid Color

On-site multifunction calibrator

4830B accelerometer simulator Product overview

High-Resolution Corrosion Monitoring for Reliable Assessment of Infrastructure

PORTABLE EDDY CURRENT FLAW DETECTOR

UM-1D ULTRASONIC THICKNESS GAUGE USER MANUAL

Easy Ultrasonic Phased Array Inspection of Corrosion - Resistant Alloys and Dissimilar Weld Materials

Agilent EPM Series Power Meters

fkpqor`qflk=j^kr^i bml`e=q m~êí=kçk=vnmjooma OLOOLMQ

Instruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1

The Probe KK&S INSTRUMENTS - April / June 2013

Automatic hardness testing devices

Inovision Model 451P Pressurized µr Ion Chamber Survey Meter

Fault Mapper Cable Length Meter & Fault Locator Alphanumeric TDR Model CA7024

WaveAce 1000 and 2000 Oscilloscopes

PIPELINE DEFECT MAPPER

Digital scales description S_System LIN Precision measuring set for new development and retro-fitting Easy to integrate in your projects Small overall

cable and pipe locators RD Utility cable and pipe locator

Obsolete Document. Dynatel

KATflow 230 Portable Clamp-On Ultrasonic Flowmeter

Pipeline Current Mapper

USER S MANUAL EPOCH LT

PIE 525B. Automated Thermocouple & RTD Calibrator Operating Instructions. Practical Instrument Electronics

PORTABLE EDDY CURRENT FLAW DETECTOR VD3-81 EDDYCON

GC723A / GC724B Cable and Antenna Analyzer

Insulation resistance testing. A complete solution for every application

ADMS-847 Programming Software for the Yaesu FT-847

MIT400 CAT IV Industrial Insulation Testers

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes

Electrical and HVAC Test Tools

Technical Specification FLUXUS ADM 8x27

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

S u b s i t e L o c at o r s

Specification DataFile

UM-2 ULTRASONIC THICKNESS GAUGE USER MANUAL

Compact Signal Calibrator

ABB conductivity analyzer and probe package

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Easy to Use Design.

U1604A Handheld Oscilloscopes, 40 MHz

DITCH WITCH ELECTRONIC GUIDANCE EQUIPMENT

Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide

Specifications for 3M Dynatel 2273M/M-iD Cable/Pipe and Fault Locators

General information on NKD - 019E «UltraSonic»

Insulation resistance testing. A complete solution for every person.

MIT400 Series CAT IV Insulation Resistance and Continuity Testers

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

DOCUMENT OBSOLETE. Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

JD723A/JD724B/JD726A Cable and Antenna Analyzers

PIECAL 211 Automated RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

FIXTURLASER NXA Ultimate

Advancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016

PV200. Why buy the PV200? The most compact I-V curve tracer around.

UltraTEV Locator Portable Partial Discharge (PD) investigation system.

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3

MIT400/2 CAT IV Insulation testers

CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer

Model FD800DL & FD800DL+ Corrosion and Flaw Gauge. Operating Instructions

S L n u. M e. E n te r. Transmitter: Flow range: 0 ~ ±40ft/s (0 ~ ±12m/s) Accuracy: ±1.0% Repeatability: 0.3% Outputs: OCT, KHz

MFD900. The most industrial ultrasonic test system for flaw detection and thickness measurements

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description

Dynatel Cable/Pipe and Fault Locator 2273M Cable/Pipe, Fault and Marker Locator 2273M-iD

A NEW GENERATION PROGRAMMABLE PHASE/AMPLITUDE MEASUREMENT RECEIVER

Transcription:

MG2, MG2-XT, and These small affordable ultrasonic thickness gages are primarily designed for inspectors and maintenance engineers responsible for measuring the remaining thickness of internally corroded pipes, tanks, and other metal structures. Lightweight and ergonomically designed for easy one-hand operation, these gages provide cost-effective measurement solutions in many applications that require quick inspection of materials suspected of metal wall thinning. Olympus NDT is known worldwide as a manufacturer of innovative, state-of -the-art ultrasonic testing products. We also believe that our customers deserve thickness gages that truly combine quality, accuracy, and ease of operation at affordable prices. We have accomplished this with three rugged models: the MG2, MG2-XT, and. Each offers a range of practical measurement features to solve a wide variety of thickness gaging problems. Even better, they all have in common being manufactured by a company that takes pride in having the best customer support network in the industry. MG2 Series Corrosion Thickness Gages Measurements from one side! Ultrasonic thickness gages make instant digital measurements by transmitting sound into a material from one side, making it unnecessary to cut the corroded part. Lightweight and pocket-size These handheld gages are small enough to fit in a toolbox or inside your pocket. They are ideal for quick inspections in hard-toreach areas. Intuitive, color-coded keypad You can directly access many important measurement features for time-saving operation. Strategically located keys are grouped together by color for easy operation. Large LCD with backlight The large numerals make it easy to read thickness measurements. In addition, you can easily view the electroluminescent backlit display from total darkness to bright sunshine. MG2-xt and are available with THRU-COAT, B-scan and optional Live A-scan with Waveform Adjust 920-038D

Choose From Three Units MG2 The MG2 offers many basic features such as Min/Max Mode that measures and recalls the minimum thickness at a fast 20 readings per second, Freeze Mode to instantly capture critical thickness, and Zero Compensation to ensure optimal transducer performance. Various other features make this handheld gage an affordable unit for quick spot measurements. MG2-XT The MG2-XT has all of the features of the MG2 plus much more! B-scan, Gain Adjust, Auto Sensitivity Optimizations, Echo-to-Echo, Thru-Coat, Differential Mode, Hi-Low Alarm, and the optional live A-scan are added features to provide you with more measurement capabilities in tough applications. This gage is ideal when you make thickness measurements on coated or painted surfaces. The is the most advanced unit of our new MG2 Series gages. It includes all of the features found in the MG2-XT plus a versatile file-based alphanumeric data logger that employs incremental, sequential, 2-D and GridView grid file formats. Using the optional GageView Interface Program you can transfer your data bi-directionally to and from your PC and gage. The is the answer if you re looking for an affordable gage with unique measurement capabilities such as Thru-Coat and Gain Adjust. Comparison Chart MG2-XT MG2 Thickness Range.020-25.00 (0.50-635.0 mm) 3 3 3 Thickness Display Resolution up to 0.001 (0.01 mm) 3 3 3 Automatic Probe Recognition 3 3 3 High Temperature Capabilities 3 3 3 Fast Measurement Rate of 20 per second 3 3 3 Min/Max Mode 3 3 3 Freeze Mode 3 3 3 Zero Compensation Mode 3 3 3 Display Hold/Blank 3 3 3 Inches/Millimeters Mode 3 3 3 Live A-scan with Waveform Adjust (optional) 3 3 - Gain Adjust 3 3 - B-scan 3 3 - Auto Sensitivity Gain Optimization 3 3 - Differential Mode 3 3 - Hi-Low Alarm 3 3 - Thru-Coat 3 3 - Echo-to-Echo 3 3 - Internal Datalogger 3 - - 2-D Grid 3 - - GridView 3 - - GageView PC Interface Program 3 - - display L A B C D E F G H K J I A. File Name 2 B. Freeze Mode C. Differential Mode 1 D. Hi-Low Alarm 1 E. Gain Adjust 1 F. Measurement Rates G. Previous Thickness 2 H. Current Measurement I. Battery Life J. Available Keys K. User Help L. ID# 2 1 Features provided with the MG2-XT and 2 Features provided with the

practical measurement features (MG2-XT and only) Thru-Coat With this patented technology, the gage simultaneously displays the thickness of the coating and the true metal thickness, using a single backwall echo. Each measurement is adjusted for their calibrated material sound velocity. Thru- Coat measurements use the D7906-SM and D7908 transducers. Echo-to-Echo The gage displays the true metal thickness and ignores the thickness of the coating layer, using multiple backwall echoes: - Auto Echo-to-Echo - Manual Echo-to-Echo (Live A-scan mode only) that allows: Gain Adjust Extended Blanking Echo Blanking B-scan Corrosion Mapping The MG2-XT and offer the B- scan feature that converts live thickness readings into cross-sectional images drawn on the display. This standard feature is a very helpful in applications when it is desired to review how the thickness is changing over a distance. When the user activates the B-scan feature it starts drawing the crosssectional thickness when the transducer makes contact with the material. The Freeze Min function can be used to display the Minimum thickness of the scanned area. Up to 350 B-scan images can be stored in the s data logger. THRU-COAT Thickness Metal Thickness Live A-scan with Waveform Adjust This optional live A-scan mode allows the user to view the ultrasound waveform (or A-scan) directly on the gage s display, verify the thickness reading, or make manual adjustments to gain and blanking settings to maximize measurement performance for challenging applications. This helpful option has the following features: Manual Gain Adjust, Extended Blanking, Echo Blank Range and Delay. Gain Adjust This feature is very helpful when making measurements on sound-attenuating materials such as cast metals: - Preset Gain Adjust to High, Low, or Standard - Manual Gain Adjust can be set in 1 db increments (Live A-scan mode only) Extended Blanking Allows blanking of unwanted echoes due to material surface noise from rough or irregular surfaces (Live A-scan mode only). Extended Blank Echo Blank High Temperature Surfaces The MG2-XT and are ideally suited for making stable thickness measurements on hot material surfaces, up to 932ºF or 500ºC, with the D790 series transducers (D790, D790-SM, D790-RL, D790-SL). The Zero Compensation feature on the MG2 Series enhances the accuracy of the readings on hot surfaces by compensating for temperature changes in the transducer delay line due to thermal drift. D790 Transducer

DATA COLLECTION FOR FAST AND RELIABLE DOCUMENTATION Internal Data Logger The powerful internal data logger allows you to store, recall, and transmit 8000 thickness readings along with their Identification Codes. With the optional live waveform mode these gages can also store 350 wave forms with thickness readings. All stored information can be transmitted from these units to your computer for statistical analysis. Alphanumeric Identification Codes You can assign an eight character file name and up to ten alphanumeric ID numbers to each stored thickness measurement. Each thickness reading is fully documented with parameter information such as material sound velocity, transducer data, and measurement mode. On-board Statistics Calculator The Model internal data logger features an on-board statistical calculator to generate reports that can be transmitted directly to your printer. Statistic report showing Minimum and Maximum values. GridView The GridView feature (only available on the ) permits viewing of stored thickness data in a Grid or Expanded Liner format. It allows the user to easily review and navigate saved thickness data in a Row and Column grid by simultaneously displaying the grid positions along with the current thickness reading. Statistic report showing Hi/Low Alarms, Mean, Median and Standard Deviation. This printed measurement report contains measurement, ID and other parameters. GAGEVIEW The optional GageView Interface Program, a Windows-based application, collects, creates, prints, and manages data from the. Datasets and Surveys creation Downloading and uploading thickness surveys to and from the gages A color coded grid easily flags out-of-tolerance thickness conditions. Stored data editing Viewing Dataset and Survey file information including thickness readings, gage setup values, and transducer setup values Exporting Surveys to spreadsheets and other programs Collecting snapshot screens Printing reports such as Thickness, Setup Table, Statistics, and Color Grid Upgrading operating software Drag and drop to Excel spreadsheet

Transducers with Automatic Probe Recognition Each MG2 series gage is compatible with our complete line of easy interchangeable dual element transducers that vary in frequencies, diameters, and temperature capabilities to deal with virtually every application. Transducer Part Number Frequency MHz Tip Diameter Cable Connector Location Range in Steel Temperature Range Wand Holder (with wand) D790 D790-SM D790-RL D790-SL 5.0 LCMD-316-5B LCLD-316-5G LCLD-316-5H 1.0-508 mm -5 to 932 F -20 to 500 C F152 F152 F152 F152A F152A F152A D791 5.0 1.0-508 mm -5 to 932 F -20 to 500 C F153 D791-RM 5.0 LCMD-316-5C 1.0-508 mm -5 to 752 F -20 to 400 C D792 D793 10 0.020-1 0.5-25 mm F150 F151 F150A D794 D795 5.0 0.030-2 0.75-50 mm F150 F151 F150A D797 D797-SM 2.0 0.900 22.9 mm LCMD-316-5D 0.150-25 3.8-635 mm -5 to 752 F -20 to 400 C D7226 D798-LF 7.5 0.350 8.9 mm 0.028-4 0.71-100 mm -5 to 300 F -20 to 150 C D798 D798-SM 7.5 LCMD-316-5J 0.028-4 0.71-100 mm -5 to 300 F -20 to 150 C D799 5.0 1.0-500 mm -5 to 300 F -20 to 150 C D7906-SM 5.0 LCMD-316-5L 0.040-2.0 1.0-50 mm D7908 7.5 0.028-1.5 0.71-37 mm MTD705 5.0 0.200 5.1 mm LCLPD-78-5 0.040-0.75 1.0-19 mm D791 D793 D7908 D790-RL D792/D794 D790 D795 D791-RM D790-SL MTD705 D7226 D790-SM D7906-SM D798-LF D799 D797-SM M2017 M2091 D798

MG2 SERIES SPECIFICATIONS* Measurements Measurement Mode: Pulse echo with dual element transducers Thickness Measurement Range: 0.020 to 25.00 inch (0.50 to 635.0 mm) Thickness range depends on material, transducer, surface condition, temperature Material Velocity Calibration Range: 0.0200-0.7362 in/μsec (0.508-18.699 mm/μsec). Display Modes Digital Thickness Readout Cross-sectional B-scan A-scan or Waveform (optional) DB Grid ( only) Thickness Display Resolution: LOW: 0.01 0.1 mm STANDARD: 0.001 0.01 mm Measurement Rates: Standard Rate: 4 per second. Fast Rate: 20 per second. Min/Max Mode: Measures and recalls minimum or maximum thickness at 20 measurements per second. Freeze Mode: Freezes display to instantly capture critical thickness. Minimizes transducer couplant lift-off error and facilitates High Temperature measurements. Automatic Probe Recognition: Automatically recognizes the listed Panametrics-NDT transducer types. Adjusts internal parameters and corrects V-path error. Zero Compensation: Compensates for transducer temperature and zero offset. Display Display Hold/Blank Mode: Display holds or blanks after measurement. Electroluminescent Display Back Lighting: Selectable as On or Auto On Receiver Bandwidth: 1-18 MHz (-3 db) Metric/English Mode: Metric or English Display Languages: English, French, German, Spanish, Italian, and other custom languages Power Supply Battery: 3 AA alkaline batteries Operating Time: 150 hours typical battery life, 30 hours continuous with backlight on Low Battery Indicator: Continuously indicates battery status Battery Saver: Auto Power Off/Continuous On General Environmental IP-65 Compliant: Splash-proof, impact-resistant case. Sealed, color-coded keypad with tactile and audible feedback. Operating Temperature Range: -10 C to +50 C, +14 F to 122 F. Size: 3.31 W x 6.0 L x 1.56 H (84 x 152.4 x 39.6 mm) Weight: 12 oz. (0.34 kg) MG2-XT and additional specifications Thru-Coat Measurement: Meaurement of true metal and coating thickness using a single backwall echo (with D7906-SM and D7908 transducers) Thru-Paint Echo-to-Echo: Displays the true metal thickness and ignores the thickness of the coating layer, using multiple backwall echoes. - Auto Echo-to-Echo - Manual Echo-to-Echo (Live A-scan mode only) that allows: Gain Adjust Extended Blanking Echo Blanking Gain Adjust: - Preset Gain Adjust to High, Low or Standard - Manual Gain Adjust can be set in 1 db increments (Live A-Scan mode only). Extented Blanking: Allows blanking of unwanted echoes due to material surface noise from rough or iregular surfaces (Live A-scan mode only). Auto Sensitivity Gain Optimization: Allows the normal measurement sensitivity to be automatically increased or decreased depending on the thickness and material noise level. Alarm Mode: Programmable Hi-Low set points with audible and visual indicators Differential Mode: Displays the difference between the actual thickness measurement and a user-set reference value. Live A-scan with Waveform Adjust: Optional live A-scan mode allows the user to view the ultrasound waveform (or A-scan) directly on the gage s display. Has the following features; Manual Gain Adjust, Extended Blanking, Echo Blank Range and Delay. Internal Datalogger Datalogger: The will identify, store, recall, clear, and transmit thickness readings and gage setup information via the USB Port. Max. # of Stored Values: Over 8,000 thickness readings or 350 waveforms with thickness readings (with Waveform option) Stored Data Documentation: Each saved thickness reading is fully documented with measurement status flags and a setup number that identifies parameters such as velocity, transducer, etc. File Name Length: 8 alphanumeric characters Identification Codes: 10 character alphanumeric Identification Code system identifies or locates stored data. 4 File Templates: Incremental, Sequental, 2D Grid, and Manual from PC Standard inclusions Model MG2 Digital Ultrasonic Thickness Gage, Wrist Strap, Test Bar, Couplant, Instruction Manual and a Two Year Limited Warranty. Standard packages include a dual element transducer. OPTIONAL ACCESSORIES 2214E 5-Step Test Block, English units 2214M 5-Step Test Block, Metric units MG/EW Extended Warranty MG2/RPC Protective rubber boot GageView PC interface program for the MG2/XTRETRO Convert a MG2 into a MG2-XT MG2XT/DLRETRO Convert a MG2-XT into a MG2/DLRETRO Convert a MG2 into a MG2/WF Live A-scan with Waveform Adjust for MG2-XT and only (not available for MG2). USB/ADP-115 AC-115 Power Supply USB/ADP-230 AC-230 Power Supply For additional accessories such as holders, wands, and couplants, please consult Olympus NDT. Printed 5/2006 2006 Olympus NDT, All Rights Reserved. *All specifications are subject to change without notice. Panametrics, Panametrics-NDT and the Panametrics-NDT logo are trademarks of Panametrics Inc. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies Olympus NDT 48 Woerd Ave, Waltham, MA U.S.A. TEL 781-419-3900 800 225-8330 in North America e-mail: pana@olympusndt.com www.olympusndt.com