EE1941/EN1941 One-Way Binary RF Module Installation and Operation Manual E

Similar documents
EE1941/EN1941 One-Way Binary RF Module Installation and Operation Manual D

EE1941/EN1941/EN One-Way Binary RF Module Installation and Operation Manual

EE1941XS/EN1941XS One-Way Serial RF Module Installation and Operation Manual

Murata Bluetooth mesh Node. Installation Guide

APM 6998 WiFi Module Manual

Transponder Reader TWN4 MultiTech 3 Quick Start Guide

CARE +MAINTENANCE Cleaning Important Safety Instructions Water Drop Heat Battery Charging Repair

General Safety and Precautions 1. Read all of the information in the owner s manual and other included product information in the packaging before

LOUIS VUITTON 1. Louis Vuitton Echo, locate your Horizon luggage in airports Battery indicator light. Light sensor to detect opening

MorningLinc INSTEON Morning Industry RF Doorknob/Deadbolt Controller

User s Manual Wireless Keyboard/Mouse & NANO Receiver MD-5110/MM-5110 & DG-5110

Evaluation Kit ATA8520-EK1-F and Extension Board ATA8520-EK3-F (US Version) Kit Content ATAN0157 APPLICATION NOTE

5.8G Wireless Audio Transceiver/Receiver Module DWHP83

DOWNLOAD KASA ADD TO KASA INSTALL AND POWER UP SAFETY FIRST

SYSTEM REQUIREMENTS (Windows) Windows XP(Service Pack 2 or later) or vista 3.2GHz Pentium 4 or faster Minimum 1GB of system RAM

User Manual. 1. Introduction. 2. Features

SATELLITE RADIO OWNER'S MANUAL. Type III Radio

Wireless Compliance Statements

Icon Description UP ( ) 1 BACK ( ) 4 PAGE ( )

Vehicle IoT Gateway VG34 DATASHEET OVERVIEW HIGHLIGHTS

ISTATION-N (Integration Station) User Manual

INSTALLATION MANUAL ES-SUB-WIRELESS-KIT ES-SUB-WIRELESS-RCVR

16+ HS300. Instructions for use. One Key Start/One Key Landing Function Headless Mode / One Key Return Altitude Hold Mode

BT11 Hardware Installation Guide

Link Mobile Gateway User Guide A ProVIEW System Component

ACUII-06 User Manual (NAS)

Polycom VoxBox Bluetooth/USB Speakerphone

Electronic Emission Notices

FOR TRAINING PURPOSES ONLY DATED MATERIAL. Aperio Hub AH20/AH30 Installation Instructions. ASSA ABLOY, the global leader in door opening solutions

User Manual. 1. Introduction. 2. Features

P/N: TMPRO3PLUS SERVICE AND WARRANTY

TriggerLinc. INSTEON Wireless Door Window Sensor (Open/Close) Model : 2421

RFTX-1 Installation Manual

User guide. SmartTags. NT3/SmartTagsST25a

PA421B PA821B. Front Panels. Included Components. Features. Model Variations. Antenna Combiner

OPERATION MANUAL WARNING

MS1000 User Information MS1000-H systems equipped with MX900 Micro Transceiver will Send and Receive.

DCH-G020 mydlink Connected Home Hub

MOVADO.COM/SMARTSUPPORT

StreamStick by NAV-TV is a USB-powered, HI-FI Bluetooth 4.0 audio streaming module for automotive and home use. Make ANY stereo (equipped with AUX

testosaveris 2 User Manual testo Saveris 2Introduction

User Manual. MITSUMI WiFi Module MODEL DWM-W081

HistoCore SPECTRA CV. RFID-Registration Registro de RFID Registro RFID تسجيل التعريف عن طريق الترددات الالسلكية

Pser G uide oduct Manual

System overview. be connected: Components that can. 1. OKIMAT IPS OM Massage motor. 7. Optional: Junction cable

User s Guide FM Transmitter

Blue Node. User Manual

FMT4R FM Transmitter User s manual

IRRIGATION 810-T PLUS TRANSMITTER GUIDE

260X190mm/105 克铜版纸 / 黑白印刷

ihealth Wireless Body Analysis Scale OWNER S MANUAL

6505 MICRO. Amplifier. Operating Manual.

AN-CPA70 Plus Cell Phone Signal Booster User Manual

Need Help? SA /

WIFI Control box UserManual

802.11a/n/b/g/ac WLAN Module AMB7220

FOR AVLEX ONLY MT-24A. User Guide. 2.4 GHz Digital Stationary Transmitter

StreetSounds STS-170-MMST Mobile Master. User Guide

GNSS multiconstellation, GPS+Glonass as a minimum; GSM; Accelerometer; SIM on Chip; Watch Dog; Power Management; RF transceiver; CAN Bus interface

FCC Certification Notice: IC Certification

ACT-IR220Li/220LN IrDA Serial Port Adapter

1. Constitution of the Unit Assy-Wireless Charging ( WPC ) for vehicle

TomTom Touch Fitness Tracker User Manual

1100DH High Power Wireless Receiver

or call

ACT-IR220L/LE IrDA Serial Port Adapter

STREETSOUNDS STS-170-FMST USER GUIDE V1.0. Fixed Master STS-170-FMST. User Guide V1.1 August 25,2018

User Guide. Do not copy or forward without prior approvals MIPRO. Specifications and design subject to change without notice.

Regulatory Compliance Statement

DS Keyfob Transmitter Data Guide

v Pairing Instructions for: GENERAL MOTORS REPLACEMENT FLIP KEYS

Pushbutton Transmitter Device PTM 215Z. September 17, 2013 USER MANUAL V1.0. Patent protected: US 6,747,573 US 7,019,241 Further patents pending

AIS 300 Installation Instructions

This device should be installed and operated with a minimum distance of 20 cm to your body.

Regulatory Compliance and Important Safety Information

FA401 Single Transmitter / Single Output Receiver. FA401R Single Transmitter / Single Relay Output Receiver. Installation Instructions 02305C

Technical Support, End User License & Warranty Information

OEM Compact Handheld Transmitter Data Guide

Shields. Outdoor Shields Owner s Manual. Avoidance Solutions.

IS7705. Installation & Operation Manual AUDIO INTEGRATION KIT. TranzIt LINK

How to install your ecobee Switch+

Field Hub Installation Guide. P/N Rev. C 05/15

Pushbutton Transmitter Device PTM 215 ZGPGP. June 10, 2014 USER MANUAL V1.0. Patent protected: US 6,747,573 US 7,019,241 Further patents pending

Wireless Z-Wave Control ZRP-100US Z-Wave Repeater USER MANUAL. Introduction

MPRF01 Wireless 5uA Inductive Proximity Sensor RF System

PTT- Z or PTT-U PUSH-TO-TALK Specification

NV-WA40W. Installation and User Guide

PowerView Remote Control Guide

Instruction Manual Model Upconverter

MS Long-Range Handheld Transmitter Data Guide

800 Series Transmitters Owner s Manual

Alcatel-Lucent 8340 Smart IP-DECT AP. Installation Manual

EA200 uhf EA200 vhf User Guide

LEDs: green = on amber = off blue = pairing red = replace battery. Press the power button to turn on / off.

Uplink 5500EZ. Installation and User Guide. S e pte m be r 1 2,

OEM Long-Range Handheld Transmitter Data Guide

EASYFIT Bluetooth Single / Double Rocker Wall Switch

READ ME FIRST QUICK INSTALL GUIDE. Wireless Controller Kit XWS Package Contents:

Tork EasyCube. User Manual.

T-L 810-T TRANSMITTER GUIDE

Transcription:

EE1941/EN1941 One-Way Binary RF Module nstallation and Operation Manual - 06287E 1 Overview EchoStream RF modules are designed to be easily interfaced with your electronic remote application controller (RAC). RF modules allow the assimilation of any user-specific application into an EchoStream system. Once integrated with existing products, RF modules provide you with complete EchoStream functionality. E*1941 one-way binary RF modules are end-devices that use a logic-level connection to interface with your RAC. E*1941 one-way binary RF modules can be used in either one-way or two-way EchoStream systems. Figure 1 One-Way System Components 2 One-Way Binary RF Module Components The E*1941 is a universal one-way binary RF module with two alarm input pins, allowing the use of dual inputs. nput one is the primary alarm, bit 0; input two is the secondary alarm, bit 1. There are two models in the E*1941 product family. The EN1941, for 900 MHz applications in North America, New Zealand, and Australia, The EE1941, for 868 MHz applications in Europe B C D E F G H A K L M J O N A Board stabilization hole. B Reserved C Reserved D Secondary alarm E Power F Ground G Primary alarm H LED contacts Tamper input J Reset input K ES selection pins L N/O selection pins M Mounting hole N On-board antenna O Board stabilization hole Frequency band selection pins (EN1941 only) Place a jumper to select the frequency band for your geographic area. Place the jumper on the left two pins to select 915-928 MHz for Australia. Place the jumper on the right two pins to select 921-928 MHz for New Zealand. Leave the jumper off the pins to select 902-928 MHz for North America. ES selection pins (EE1941 only) To enable compatibility with ES products, place a selection jumper on the ES selection pins; if no ES products are used in your system, remove the selection jumper. N/O selection pins Place a jumper to select normally open inputs; remove the jumper to select normally closed. Note: The E*1941 is shipped with the jumper unattached. With the jumper unattached, the E*1941 defaults to normally closed. Secondary alarm Connects a secondary end-device to provide RF alarm data for any user-specific application. Primary alarm Connects a primary end-device to provide RF alarm data for any user-specific application. Tamper input Connects a tamper input to send a message when userspecific end-device is tampered with. Reset input Connects a reset input to reset the one-way binary RF module after a frequency band selection change or N/O - N/C selection change, and to initiate an RF transmission. Power Connect power cabling to an external power supply of 2.4 to 5.5 volts. Ground Connects to ground. Mounting hole Used to mount the one-way binary RF module to the userspecific product. The mounting hole should only be used with a nylon standoff, never metal. LED contacts Use to control an LED switch. Not designed to drive LED power. Board stabilization holes Used to mount and stabilize the board. The board stabilization holes should only be used with non-metal standoffs. Figure 2 EN1941 One-Way Binary RF Module Components A Board stabilization hole. B Reserved C Reserved D Secondary alarm E Power F Ground G Primary alarm H LED contacts Tamper input J Reset input K Frequency band L N/O selection pins selection pins M Mounting hole N On-board antenna O Board stabilization hole A K L M B C D E F G J O N H Figure 3 EE1941 One-Way Binary RF Module Components 4.9.13 06287E novonics, 2013 - www.inovonics.com

3 One-Way Binary RF Module Dimensions.090 to Center of First Pin Pitch: 2.54mm..156 Diameter.515 to Center of Hole.335 to Center of Hole 1.3 J The RF module should be integrated so the antenna is unobstructed by the end user s PCB, batteries, or any other conductive material. Clear transmit region in front and back of antenna RF module.385 to Center of First Pin End user application printed circuit board.5 2.525 Figure 4 E*1941 One-Way Binary RF Module Dimensions 4 One-Way Binary RF Module Connections and Output Jumpers 5 nstallation A Connecting the One-Way Binary RF Module B One-way binary RF modules are designed to be easily interfaced with your electronic remote application controller, however integration must conform to the following: C The RF module must only be connected at the eight pin header or eight pin plated thru-holes. D All cables and wires must be routed away from the component side of the RF module. E The integrated antenna must not be tampered with; no connection to an alternate antenna is provided. F The application module must not include an integrated secondary colocated radio module. G The one-way binary RF module antenna should be placed so that it is facing away, or otherwise isolated from, your device s ground plane. H Components that are sensitive to RF transmission, such as high gain Primary Alarm Secondary Alarm Tamper Reset Connecti on Output Jumper N/O Open Alarm Clear Alarm Output Jumper N/C Ground Alarm Alarm Clear Open Alarm Clear Alarm Ground Alarm Alarm Clear Open Alarm Alarm Ground Alarm Clear Alarm Clear Open for normal operation; connect to the ground and release for a board reset. circuits, should be isolated from the antenna to prevent interference. One-way binary RF modules should not be mounted on metal surfaces or inside metal enclosures. They should also not be mounted where sheet metal ductwork, wire mesh screens, etc. might block transmissions. Figure 5 The RF module should be integrated so the antenna is unobstructed 6 One-Way Binary RF Module Requirements 6.1 Power Requirements The E*1941 has an on-board voltage regulator. Connect power cabling to an external power supply (Vcc) of 2.4 to 5.5 volts. Voltage must be sustained at 2.4 volts or above and supply 100 milliamps during the transmit cycle. 6.2 EN1941 Assuming check-in messages every 3 minutes and infrequent alarm messages (one per day, on average), the average current draw is 32 ua. Peak current draw while transmitting is less than 100 ma. One alarm/ restore cycle per hour results in about 5.3 ua increase in average current. 6.3 EE1941 Assuming check-in messages every 12 minutes and infrequent alarm messages (one per day, on average), the average current draw is 15 ua. Peak current draw while transmitting is less than 50 ma. One alarm/restore cycle per hour results in about 5.3 ua increase in average current. 6.4 Low Battery Condition The E*1941 measures battery voltage every three and a half hours, and, when the battery measures 2.4 volts, a serial message is sent indicating a low battery condition. 6.5 Temperature range -40 C to +66 C, non-condensing 6.6 RF network compatibility EchoStream Commercial Mesh Network 6.7 nput Requirements Caution: nput levels must not exceed 3.3 V. Open When an active source (open collector or dry contact) is used to drive the alarm or tamper input, the voltage should be between 0.75xVcc and Vcc. A passive input should have an impedance of greater than 5.1k ohm between the input and ground. Closed When an active source is used, the voltage should be less than 0.25xVcc. A passive input should have an impedance of less than 240 ohm. 6.8 LED Requirements The LED output is an active output from the microprocessor, with a 1k series resistor to limit current draw. Default state is low, and the LED pin is pulled high during transmit. 4.9.13 06287E novonics, 2013 - www.inovonics.com 2

7 Compliance Requirements 7.1 UL and cul Requirements The EN1941 Module holds a UL and cul Recognized Component Mark and is intended to be factory installed in another device, system or endproduct. The suitability of the EN1941 module for use in a UL and/or cul listed (certified) device, system or end-product, is restricted as follows: This device was evaluated as a UL/cUL Recognized Component compliant to selected requirements from UL639, ULC-S306-03, UL1076, ULC/ORD-C1076 and UL1610 as specified in the Conditions of Acceptability of the UL Report. The Supply Line Transient tests shall be added to the RAC UL evaluation program if it is powered by an AC/DC adapter rather than a low voltage battery. f intended use includes UL1610, UL1076 or UL639 installations, the RAC shall be evaluated for Short Range RF Device tests. Compatible receivers include EN4216MR, EN4232MR and EN7285. Refer to the EN4216MR nstallation and Operation Manual, the EN4232MR nstallation and Operation Manual or the EN7285 nstallation nstructions. When selecting frequency band, only devices set for use in North America are configured for UL and cul installations. 7.2 FCC Requirements for the EN1941 The EN1941 one-way binary RF module has received a Limited Modular Grant, requiring novonics to retain control of the final installation to ensure compliance to FCC/C regulations. The integrator is responsible to test the final installation to verify compliance to FCC/C regulation for unintentional emissions. Prior to marketing the product, the integrator must complete and submit to novonics a compliance review form and documentation, and, if requested, a functional product sample for approval. f this is not possible, the integrator must perform the testing themselves and submit proof to novonics of compliance to Part 15 of the FCC Rules and ndustry Canada RSS-210. At the end of this guide is an novonics compliance review form to be filled out by the integrator. The integrator is also responsible for properly labeling the product containing the one-way binary RF module. Labels must be placed on the outside of the product, and must include a statement indicating that the product contains the module, along with the FCC and C number. Example 1 Contains One-Way Binary RF Module FCC D: HCQ3B6OT9OEM; C D: 2309A-OT9OEM (EN1941-C) Example 2 Contains FCC D: HCQ3B6OT9OEM; C D: 2309A-OT9OEM (EN1941-C) 7.3 Television and Radio nterference This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. f this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. ncrease the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. 8.1 CE Label Requirements for EE1941 novonics Wireless has received European Telecommunications Standards nstitute approval to market one-way binary RF modules, and they are manufactured to be RoHS compliant. The integrator is responsible for properly labeling the product containing the one-way binary RF module. Labels must be placed on the outside of the product, and must include the CE logo. 9 Warranty and Disclaimer Note: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. novonics Wireless Corporation ("novonics") warrants its EchoStream products ("Product" or "Products") to conform to its own specifications and to be free of defects in materials and workmanship under normal use for a period of thirty-six (36) months from the date of manufacture. Within the warranty period, novonics will repair or replace, at its option, all or any part of the warranted Product. novonics will not be responsible for dismantling and/or reinstallation charges. To exercise the warranty, the User ("User", "nstaller" or "Consumer") must work directly through their authorized distributor who will be given a Return Material Authorization ("RMA") number by novonics. Details of shipment will be arranged directly through the authorized distributor. This warranty is void in cases of improper installation, misuse, failure to follow installation and operating instructions, alteration, accident or tampering, and repair by anyone other than novonics. This warranty is exclusive and expressly in lieu of all other warranties, obligations or liabilities, whether written, oral, express, or implied. There is no warranty by novonics that novonics product will be merchantable or fit for any particular purpose, nor is there any other warranty, expressed or implied, except as such is expressly set forth herein. n no event shall novonics be liable for an incidental, consequential, indirect, special, or exemplary damages, including but not limited to loss of profit, revenue, or contract, loss of use, cost of down time, or interruption of business, nor any claim made by distributor's customers or any other person or entity. This warranty will not be modified or extended. novonics does not authorize any person to act on its behalf to modify or extend this warranty. This warranty will apply only to novonics Products. novonics will not be liable for any direct, incidental, or consequential damage or loss whatsoever, caused by the malfunction of Product due to products, accessories, or attachments of other manufacturers, including batteries, used in conjunction with novonics Products. 8 FCC Part 15 and ndustry Canada Compliance This device complies with part 15 of the FCC Rules and ndustry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'ndustrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. 4.9.13 06287E novonics, 2013 - www.inovonics.com 3

novonics One-Way Binary RF Module Compliance Review Form Please provide the following information for review of final installation to ensure compliance with FCC/C regulations: Required materials from integrator The following must also be attached for review with this form: A description of the final installation, with attached photographs, as necessary The unintentional radiator test report indicating compliance ntegrator information First name: Phone number: Last name: Email address: Address: Declaration of conformity to novonics installation instructions: Submitted materials: Authorized signature: Submission date: novonics contact information novonics ATTN: Product Management 397 South Taylor Ave. Louisville, CO 80027 Phone: 303.939.9336 Toll-Free: 800.782.2709 Fax: 303.939.8977 productmanagers@inovonics.com 4.9.13 06287E novonics, 2013 - www.inovonics.com 4

Required materials from novonics The record of product sample review and test, as necessary novonics approval First name: Phone number: Last name: Email address: Approval status (pass, fail, samples required, compliance testing required, compliance test report required): Approval comments: Submitted materials: Returned materials: Authorized signature: Approval date: 4.9.13 06287E novonics, 2013 - www.inovonics.com 5