Crystal Characterisation with the TrewMac TE3001 Analyser

Similar documents
Measurement of the equivalent circuit of quartz crystals

A Walk Through the MSA Software Vector Network Analyzer Reflection Mode 12/12/09

Equivalent Circuit Determination of Quartz Crystals

Equivalent Circuit Determination of Quartz Crystals

Series and Parallel Resonant Circuits

A Walk Through the MSA Software Vector Network Analyzer Transmission Mode 12/18/09

Crystal Resonator Terminology

HARDWARE GUIDE Document Number TM1227 Document Version 9.0 May 2013

MFJ269 Antenna Analyzer Theory And Use

Lab 4. Crystal Oscillator

LABORATORY #3 QUARTZ CRYSTAL OSCILLATOR DESIGN

Lab 4. Crystal Oscillator

The Amazing MFJ 269 Author Jack Tiley AD7FO

Experiment Guide: RC/RLC Filters and LabVIEW

Study of Inductive and Capacitive Reactance and RLC Resonance

EECS40 RLC Lab guide

Vector Network Analyzer Application note

RLC Software User s Manual

BAKISS HIYANA BT ABU BAKAR JKE,POLISAS

Measurements with Scattering Parameter By Joseph L. Cahak Copyright 2013 Sunshine Design Engineering Services

Sirindhorn International Institute of Technology Thammasat University

ECE 145A/218A, Lab Project #1a: passive Component Test.

Vector Network Analyzers. Paul Coverdale VE3ICV

Bode 100. User Manual

Smart Measurement Solutions. Bode 100. User Manual

EE 340 Transmission Lines

This paper is meant assist in the operation and understanding of the VIA Bravo Family of products.

Measuring crystal motional parameters with the MiniVNA. Joop, PE1CQP

Core Technology Group Application Note 1 AN-1

Lecture 13: Impedance Inverter. Cohn Crystal Filter.

INTERNATIONAL STANDARD

Introduction to RF Measurement and Nonideal Components The Vector Network Analyzer UCSB - ECE145A/ECE218A Winter 2007

INTRODUCTION TO AC FILTERS AND RESONANCE

Circuit Characterization with the Agilent 8714 VNA

Class #7: Experiment L & C Circuits: Filters and Energy Revisited

AC Circuit. What is alternating current? What is an AC circuit?

Exercise 1: Series Resonant Circuits

Contactless RFID Tag Measurements

AA-35 ZOOM. RigExpert. User s manual. Antenna and cable analyzer

being developed. Most up and coming drugs are extremely expensive and limited in

Resonance indicator LEDº. » Transducer connection. Button B º. » LCD display. Power/fine frequency º. frequency set

Characteristics of Crystal. Piezoelectric effect of Quartz Crystal

Electronics and Instrumentation ENGR-4300 Spring 2004 Section Experiment 5 Introduction to AC Steady State

LCR Parallel Circuits

RigExpert AA-170 Antenna Analyzer (0.1 to 170 MHz) User s manual

UNIVERSITY OF BABYLON BASIC OF ELECTRICAL ENGINEERING LECTURE NOTES. Resonance

EE 340 Transmission Lines. Spring 2012

Review: The MFJ-223 Vector Impedance Antenna Analyzer Phil Salas AD5X

EC Transmission Lines And Waveguides

CHAPTER 14. Introduction to Frequency Selective Circuits

Class XII Chapter 7 Alternating Current Physics

Microwave/Millimeter-Wave RCS Test System

University of Jordan School of Engineering Electrical Engineering Department. EE 219 Electrical Circuits Lab

Short Tutorial on Quartz Crystals and Oscillators

Lecture 16 Date: Frequency Response (Contd.)

RLC Frequency Response

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Application Note. Application for Precision Impedance Meters in a Standards Laboratory. Required Capabilities for Precision Measurements

Question Paper Profile

Core Technology Group Application Note 6 AN-6

LAB 8: Activity P52: LRC Circuit

TUNED AMPLIFIERS 5.1 Introduction: Coil Losses:

The Series RLC Circuit and Resonance

ARRAY SOLUTIONS 350 Gloria Rd Sunnyvale, TX PowerAIM 120. Mar 10, 2008

Activity P52: LRC Circuit (Voltage Sensor)

INTERPRETATION METHODOLOGY TO IDENTIFY FAULT LOCATION IN A POWER TRANSFORMER

Transmission Lines As Impedance Transformers

Module 2 : Transmission Lines. Lecture 13 : Application of Transmission Lines continues. Objectives. In this course you will learn the following

A handy mnemonic (memory aid) for remembering what leads what is ELI the ICEman E leads I in an L; I leads E in a C.

Radio ETI031 Laboratory Experiments 2: VECTOR NETWORK ANALYSER, ANTENNA and RECEIVER MEASUREMENTS

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

Resonance. A resonant circuit (series or parallel) must have an inductive and a capacitive element.

Oscillators. An oscillator may be described as a source of alternating voltage. It is different than amplifier.

Contents. Core information about Unit

Application Note. Calibration of 7000 Series Precision LCR Meters

Resonant and Nonresonant Lines. Input Impedance of a Line as a Function of Electrical Length

The Principle V(SWR) The Result. Mirror, Mirror, Darkly, Darkly

8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE

Non-ideal Behavior of Electronic Components at High Frequencies and Associated Measurement Problems

Laboratory Exercise 6 THE OSCILLOSCOPE

KINGS COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK UNIT I BASIC CIRCUITS ANALYSIS PART A (2-MARKS)

Microwave Metrology -ECE 684 Spring Lab Exercise T: TRL Calibration and Probe-Based Measurement

Lab E5: Filters and Complex Impedance

Harmonic Design Considerations for Wind Farms

Experiment 7: Undriven & Driven RLC Circuits

An Oscillator Scheme for Quartz Crystal Characterization.

Design note for YIC Quartz Crystal Unit

CHAPTER 2. Basic Concepts, Three-Phase Review, and Per Unit

The Woofer Tester Pro. Integrated Speaker Measurement & Design. Web: Phone:

Challenges and Solutions for Removing Fixture Effects in Multi-port Measurements

Product Overview: Main Features: AV3672A/B/C -S Vector Network Analyzer. (10MHz~13.5 GHz/26.5 GHz/43.5 GHz)

Series Resonance. Dr. Mohamed Refky Amin

TEST EQUIPMENT PLUS. Signal Hound USB-SA44B / USB-TG44A. Application Note 1: The Smith Chart. Rev. 0

Table of Contents Lesson One Lesson Two Lesson Three Lesson Four Lesson Five PREVIEW COPY

AC Measurements with the Agilent 54622D Oscilloscope

When you have completed this exercise, you will be able to determine the frequency response of an

Lab 9 - AC Filters and Resonance

EC6503 Transmission Lines and WaveguidesV Semester Question Bank

Exercise 1: RF Stage, Mixer, and IF Filter

I-V, C-V and AC Impedance Techniques and Characterizations of Photovoltaic Cells

Transcription:

Crystal Characterisation with the TrewMac TE300 Analyser The TrewMac TE300 Analyser is an excellent tool for the measurement and characterization of quartz crystals and resonators. With Hz resolution, a range of display formats and a purpose built holding fixture, crystal behaviour can be explored by manual scanning, frequency sweeping, or by using the fully automated utility. This article demonstrates how to use the TE300 and software to measure and calculate the static and motional parameters of an 8MHz quartz crystal. Article Contents:. Quartz crystal model and behaviour 2. Calibrating the tweezer attachment 3. The automated function 4. Hints for operation Equipment Used: An 8MHz quartz crystal TrewMac TE300 Network Analyser TrewMac tweezer attachment

. Quartz Crystal Model The electrical behaviour of quartz crystals around their fundamental frequency can be modelled by the 4 parameter equivalent circuit shown below. While this is only an approximate model, it is sufficient for most practical purposes. The model consists of 2 arms in parallel. The static arm consists of a single capacitance Co. This includes the bare crystal capacitance and the packaging capacitance. The motional arm consists of the series combination of R,C and L. An impedance sweep of the 8MHz crystal is shown below. (taken with the equipment listed above) fp

Series resonance occurs at frequency with the first change in phase and the null in magnitude. Parallel resonance occurs at frequency fp with the second change in phase and the peak in magnitude. Between and fp is called the inductive region because phase is positive. Below the crystal is nearly pure capacitance due to Co. Above fp harmonic overtones can be seen. Overtones Below the crystal is dominated by Co. If we change the format to equivalent parallel RLC we can see that for this crystal Co=5pF. Co

At, the reactance of C and L cancel, leaving only R. (Co has almost no effect) Hence R can be taken directly as the magnitude of impedance at. R C and L are more difficult to obtain by measurement, but can be calculated as: fp = 2C 0 C L= 2 2 4Cπ Other parameters for crystal characterisation include quality factor Q, figure of merit M and capacitance ratio r. These can be calculated as: Q= 2πR C M = 2πR C 0 C r= C 0

2. Calibrating the tweezer attachment. The tweezer attachment is the easiest way to hold and measure a regular quartz crystal. Before accurate measurements can be obtained, the effect of this fixture must be calibrated out. This is easily achieved using the custom cal routine. Step Connect the tweezer attachment using as short a cable as practical. (any length of cable between the analyser and the point of measure introduces errors that can not be completely removed by even the best calibration equipment!) Step 2 Press System Zo and select Calibration from the menu. Select CUSTOM as the type, SMD as the kit and I used 0.3 and 00 MHz as the start and stop values.

Step 3 Select Perform Cal. You are prompted to measure the SMD calibration standards one at a time with the tweezers. When finished select Done. Now you are ready to measure! 3. Using the automated function Select Crystal Characterisation from the utilities menu. Enter the fundamental frequency of the crystal and press go! All the parameters are measured and calculated for you. These values are also copied to the clipboard to paste into a document. So easy!

4. Hints for operation The crystal characterisation utility expects the crystal frequency entered by the user to be located between and fp in the inductive zone. See the diagram below: Crystal Frequency fp If the crystal frequency entered by the user does not return positive phase, the utility displays a warning that it cannot proceed as it has not started in the inductive region. In this case, try a frequency sweep from % below to % above the specified crystal frequency. Use the polar impedance chart. Look for the region where phase is positive and choose a new crystal frequency in that region.