kv AC substation

Similar documents
SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

Safety earthing. Sector Energy PTI NC. Copyright Siemens AG All rights reserved. Theodor Connor

6B.6 Substation Grounding

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01

CONTINUING EDUC ATION

Industrial and Commercial Power Systems Topic 7 EARTHING

Article 250 Grounding & Bonding

Earthing of Electrical Devices and Safety

SECTION - 3 EARTHING CLAMPS & FITTINGS

Collection of standards in electronic format (PDF) 1. Copyright

Field Instruction. Induced voltages can occur in overhead lines, underground cables, or in switchyards.

Isolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones

Reference Number PDS 04 (RIC Standard: EP SP)

American Electrical Institute

TABLE OF CONTENTS. Impregnated... 1 NORDIC FENCE Fynbo FSC Certified... 1

The Variable Threshold Neutral Isolator (VTNI)

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

Test Joints / Fixed Earthing Terminals

IMP/010/011 Code of Practice for Earthing LV Networks and HV Distribution Substations

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

Cable Protection against Earth Potential Rise due to Lightning on a Nearby Tall Object

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

Need for grounding Codes and Standards for grounding Wind Turbine Generator grounding design Foundation + Horizontal Electrode grounding design

EMC Philosophy applied to Design the Grounding Systems for Gas Insulation Switchgear (GIS) Indoor Substation

PRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another.

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: Document Number: KUCSH0039 Rev: 4

Power Quality. Case Study. Conrad Bottu Laborelec January 2008

VI 3 - i TABLE OF CONTENTS

APPENDIX FENCE GENERAL NOTES

G81 PART 1 FRAMEWORK APPENDIX

SCHEDULE OF WORK. Balmer Lawrie Co. Ltd. PRICED BID (PART-II) MMLH

Stray Voltage and Swimming Pools

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

HV SYSTEMS. Prysmian HV Systems Product Range 66kV & 132 kv

GROUNDING EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA

Australian Standard. Switchgear assemblies and ancillary equipment for alternating voltages above 1 kv AS

EDS LV SUPPLIES TO MOBILE PHONE BASE STATIONS MOUNTED ON TRANSMISSION TOWERS

EI HIGH VOLTAGE INSULATION TESTING POLICY

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT OFFICE

Status Date Prepared Reviewed Endorsed Approved

FAQ ON EARTHING STANDARDS 16/08/2018

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

PRACTICAL PROBLEMS WITH SUBSTATION EARTHING

Installation Guide. Capped Cellular PVC Fencing. Table of Contents. Storage and Handling Tools Needed Fence Layout and Locating Posts

Agenda. Earthing of Telecom Installations using Single Point Earthing. Reference Documents. How many earths? Earthing Issue...

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 BONDING METHODS

Earthing Requirements for HV Transmission Structures

DESIGN PRACTICE NOTE DESIGN/REVIEW REQUIREMENTS FOR TRACTION BONDING PLAN

TS RES - OUTSTANDING ISSUES

HV Substation Earthing Design for Mines

VBS TBS KTS BSS LFS UFS

Functional Specification Revision History

Underground System Design TADP 547

Lightning Protection Guide. Rack-mountable Devices

Wisconsin Contractors Institute Continuing Education

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

Earth Mat Design for a 66kv Substation

OIL-IMMERSED ARC-SUPPRESSION COILS

Product Catalogue CABLE CONNECTION TECHNIQUE. Ring Connectors

Module Title: Electrical Installation II Laboratory Sheet:

METER - INSTALLATION Pad Mount Transformer

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

ECP HV INSULATION TESTING

Reference Number PPS 05 - (RIC Standard: EP SP)

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

Notes 3 Explanatory Information 4-10

ECP HV INSULATION TESTING

METRIC LIGHTNING PROTECTION PRODUCTS

Distance Protection of Cross-Bonded Transmission Cable-Systems

This Manual Part recommends design criteria for resistors suitable for railway signaling circuits other than electronic.

ATTACHMENT - AESO FUNCTIONAL SPECIFICATION

Safety Standards. of the Nuclear Safety Standards Commission (KTA) Design of Nuclear Power Plants Against Damaging Effects from Lightning

INTERMEDIATE METAL CONDUIT

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Fault location on power cables. Fault location on power cables

25kV A.C. Electrified Lines - Traction Bonding

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

PARALLEL GROOVE CLAMPS

VariSTAR Type AZL heavy-duty distribution-class MOV arrester

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

SECTION ELECTRICAL IDENTIFICATION

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

Figure 1. Why is iron a suitable material for the core of a transformer?

Specialty Switches. Inertia Engineering & Machine Works, Inc Hardaway Road, Stockton CA 95215

Evaluating Step and Touch Potential Risks on Earthing Systems of High Voltage Cable Systems TP, THINUS DU PLESSIS ESKOM SOUTH AFRICA HJ, HARTMUT JAGAU

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

PART MATERIALS. Section Fencing Materials. Description

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

INTERNATIONAL STANDARD

Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E.

DESIGN OF A 45 CIRCUIT DUCT BANK

EPR Safety Mat Modelling & Field Testing Summary Report

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

Customer Requirements RF Antenna Installations

MEDIUM VOLTAGE TERMINATIONS CATALOGUE 2017

Transcription:

132-400 kv AC substation Outdoor AC substations Earthing systems ETS-50-08-01, Rev. 0 technical standard Document no. 13/90592-127 ETS-50-08-01 v. 0

REVISION VIEW Document no.: 13/90592-127 Version Author Document status/change Reviewer Approver Date 0 JAS Translated to English JLY, THO JSO 27-05-2014 This standard supersedes the Danish version. Document no. 13/90592-127 ETS-50-08-01 v. 0 2/8

Table of contents 1. Introduction 4 2. References 4 3. Functional requirements 4 4. Technical requirements 4 4.1 Earthing network 4 4.2 Earthing of steel supports/high-voltage apparatus 5 4.3 Earthing of voltage transformer 5 4.4 Earth electrodes 5 4.5 Outer substation fence and gates 6 4.6 Expansion of the earthing system 6 4.7 Documentation 6 5. Appendix 1: Example of an earthing network 7 6. Appendix 2. Installation of cable connection on steel support 8 Document no. 13/90592-127 ETS-50-08-01 v. 0 3/8

1. Introduction This standard specifies the minimum requirements for earthing systems designed for outdoor substations in the 132-400 kv nominal voltage range. All high-voltage grids in Denmark in the 132-400 kv voltage range are effectively earthed. The requirements stated in the technical specification for any specific unit take precedence over the requirements stated in this standard. 2. References ETS-50-00 Outdoor AC substations. General The Danish Heavy Current Regulation, part 2 Design of electricity supply systems 3. Functional requirements The purpose of the earthing network on a high-voltage substation is to protect personnel against injury and eliminate the risk of extensive damage to the system caused by earth faults. The risk of injury to personnel outside the outer substation perimeter caused by highvoltage faults must also be dealt with. This in particular applies if electrically conductive connections are routed from the substation area to the surrounding areas. 4. Technical requirements Energinet.dk states the maximum future earth current as well as the maximum duration of a high-voltage fault. The earthing network of the given substation must as a minimum be dimensioned for this earth current during this period of time. The earthing resistance for the complete system must not exceed 0.1 ohm for large-scale substations. For small-scale substations (eg GIS substations and cable stations), a detailed analysis of the earthing network design is required. For new substations, the specific earth resistance must be measured in collaboration with Energinet.dk. Based on such measurement, Energinet.dk will conduct an analysis of the preliminary design and recommend improvements, if any. The earthing network must be constructed to comply with the requirements of the Danish Heavy Current Regulation, part 2, section 9, as well as appendices A to S, excluding appendix H. 4.1 Earthing network The earthing network must be a meshed network connected with compression tap connectors (H-shaped) at all crossings. The typical mesh size is approximately 10 x 10 m, but is otherwise adjusted to the position of the individual foundations and apparatus. Document no. 13/90592-127 ETS-50-08-01 v. 0 4/8

The mesh size should be smaller under special conditions, for example for transformers and reactors. Earthing conductors must always be laid in and along cable ducts. See the example of an earthing system in appendix 1. The earthing network must be installed at a depth of 1.0-1.1 m below the final ground level. Endeavours should be made to ensure that the individual earthing conductor goes uninterrupted from earth electrode to earth electrode. If the earthing conductor has to be elongated, two H-shaped compression tap connectors must be used to safeguard the connection. The conductors in the earthing network must be made from hard-drawn, non-insulated copper wire and be dimensioned according to the size and duration of the earth current. For an earth current of, for example, max 30 ka for 1 sec., the earthing network must be laid out with 95 mm 2 copper. For 40 ka for 1 sec., 120 mm 2 copper must be used. 4.2 Earthing of steel supports/high-voltage apparatus Double upward wire routing must always be used for the individual support/apparatus The two upward wire routings are established by routing the earthing conductors uninterrupted and directly to the support after which an H-shaped compression tap connector is installed in the ground between the two upward routings. The connector ensures a galvanic connection in the actual earthing network, also if the connection to the support fails or must be removed. The two earth connections are routed up through the foundation in a plastic pipe. If such a plastic pipe is not available (eg in old substations), the earth connections must be routed in a plastic pipe on the outside of the foundation. The connections must be terminated on the support/apparatus in two tinned cable lugs. Each cable lug must be fixed to the support/apparatus with a hot-dip galvanised M12 bolt and nut, see appendix 2. In special cases, underground electrical connections between two different metals (eg steel/copper reinforcing steel/earthing network) can be performed by means of CADWELD welding. 4.3 Earthing of voltage transformer Voltage transformers must be earthed as specified in section 4.2. In addition, the support must have two additional connections to two separate earth electrodes. See appendix 1. 4.4 Earth electrodes In the periphery of the earthing system, an earth electrode must be driven down in every second mesh on the outside. An earth electrode is constructed as a steel pipe for routing down the copper wire to the correct depth. The copper wire constitutes the actual earthing. Document no. 13/90592-127 ETS-50-08-01 v. 0 5/8

The earth electrodes are normally driven down to a depth of approx 6 m; however, depending, on the given ground conditions, it may be required that the earth electrodes are driven down deeper to achieve a satisfactory earthing resistance. 4.5 Outer substation fence and gates It must be ensured that dangerous touch voltages can never occur outside the outer substation fence. The outer substation fence and gates are not connected to the earthing system of a highvoltage substation unless the distance between the earthing network and the fence/gate is less than 2 m. If the distance is less than 2 m, potential rings must be laid out in the relevant area to prevent dangerous touch voltages. In such cases, it must be agreed with Energinet.dk how to earth fences/gates. If standard gates or sliding gates are used for access to the substation, a suitable bonding conductor must be established between the parts that are galvanically connected to the fence on both sides of the gate. Electrically conductive connections leading out from the substation area (eg 380 VAC supply) must be ensured to avoid dangerous touch voltages. 4.6 Expansion of the earthing system If an existing earthing system has to be expanded, the expansion must be made using the same technology and approach as previously used for the substation, if possible. Any deviations must be agreed with Energinet.dk. The Danish Heavy Current Regulation, part 2, must always be observed, and the expansion must be documented according to the same rules that apply to documentation for a new system. 4.7 Documentation The complete earthing network must be documented on a drawing showing earthing conductors, earth electrodes, connections to the individual apparatus, all joints as well as the connections leading into the control building of the substation. The depth for earthing conductors and for the individual earth electrodes must be documented. The earthing resistance of the individual earth electrodes as well as the substation s total earthing resistance must be measured and documented. By means of a representative selection of measurements, it must be documented that dangerous touch voltages cannot occur in the event of an earth fault. This must be documented for both the inside and outside areas of the substation. Document no. 13/90592-127 ETS-50-08-01 v. 0 6/8

5. Appendix 1: Example of an earthing network (The full-size drawing can be ordered from Energinet.dk.) Document no. 13/90592-127 ETS-50-08-01 v. 0 7/8

6. Appendix 2. Installation of cable connection on steel support Document no. 13/90592-127 ETS-50-08-01 v. 0 8/8