DISPLAY RULES AND REGULATIONS

Similar documents
THE INTERNATIONAL WORKBOAT SHOW

Island and Peninsula Booths under a Skywalk may build up to 16 * Inline/Linear Booths may build up to 8 *

Index. Linear Booth, Corner Booth and Perimeter Booth 2. End-cap Booth and Peninsula Booth 3. Split Island Booth and Island Booth 4

Corner Exhibits A Corner Booth is a Linear Booth ( In-Line ) exposed to aisles on two sides. All other guidelines for Linear Booths apply.

Guidelines for Display Rules & Regulations

Guidelines Update. For Display Rules and Regulations 3.5' 3.5' 3.5' 12' 1.75' 20'

REVISED DISPLAY RULES & REGULATIONS

Guidelines for Display Rules & Regulations 2007 Update

Display Rules & Regulations

THE SHOW. Guidelines for Booth Display/ Rules & Regulations

Guidelines for Display Rules & Regulations 2005 Update. made possible by a generous grant from Champion Exposition Services

2018 NRA Annual Meetings & Exhibits. Display Rules & Regulations

Guidelines for Display Rules and Regulations

Exhibit & Signage Guidelines

NACS Show Booth Display Guidelines

Guidelines for Display Rules & Regulations 2014 Update

Guidelines for Booth Display/ Rules & Regulations

IAEE Booth Display Rules & Regulations

Guidelines for Display Rules & Regulations 2014 Update

Made possible by a generous grant from. Guidelines for Display Rules & Regulations 2014 Update

Guidelines for Display Rules and Regulations

EXHIBIT DISPLAY GUIDELINES

Guidelines For Display Rules And Regulations

Linear Booth. Corner Booth

Exhibit & Signage Rules

Made possible by a generous grant from. Guidelines for Display Rules & Regulations 2014 Update

Guidelines for Display Rules & Regulations 2014 Update

Exhibit Space & Booth Layout Guidelines

BOOTH CONSTRUCTION & DISPLAY REQUIREMENTS Huntington Convention Center Cleveland, Ohio February 7 9, 2018

A. STANDARD BOOTH. DEFINTION One or more standard units in a straight line.

A. STANDARD BOOTH. DEFINTION One or more standard units in a straight line.

Exhibit Display Rules and Regulations

2018 NAMM Show - Booth Display Types & Regulations

Booth Display Rules. Standard Inline booth. Perimeter booth. Island booth. Peninsula Booth

Exhibitor Guidelines for Booth Display Rules and Regulations

Guidelines for Display Rules & Regulations 2014 Update

Exhibit Space & Booth Layout Guidelines

Booth Construction and Layout

Booth Construction and Layout

EXHBIT DISPLAY REGULATIONS End-Cap Booth

Exhibit Display Rules and Regulations

Exhibit Design Regulations

Exhibit Design Regulations

Exhibit Space & Booth Layout Guidelines

Made possible by a generous grant from. Guidelines for Display Rules & Regulations 2014 Update

A. STANDARD BOOTH. DEFINITION One or more standard units in a straight line

EXHIBIT DISPLAY REGULATIONS LINEAR BOOTH April Orange County Conven on Center Orlando, Florida

EXHIBITOR RULES for AFP 2018 (Effective 02Aug2017)

Exhibit Space & Booth Layout Guidelines

All exhibits must have floor covering (wall-to-wall carpeting or other flooring), with no concrete floor exposed.

EXHIBIT/BOOTH SPECIFICATIONS

DISPLAY REGULATIONS PAGE 1 OF 6

You are not allowed to install or place anything above the maximum height allocated for each type of booth.

BOOTH RULES & REGULATIONS

Exhibit Space & Booth Layout Guidelines

Exhibit Space & Booth Layout Guidelines

Appendix G - Booth Rules and Regulations

EXHIBIT RULES & REGULATIONS

Exhibit Space & Booth Display Guidelines

General Display Rules

The maximum back wall height is eight-feet three-inches (8 3 ), including truss, and is allowed only in the rear half of the booth space.

NRF BOOTH GUIDELINES

Linear Booth. Corner Booth (3.048M) 10' (1.524M) (1.524M) 5' (1.524M) (3.048M) 10' (1.219M) PLAN VIEW LEFT SIDE VIEW (2.438M) (1.

General Rules. of the needs exhibitions. Every. have. management for booth. Flooring in. your exhibit. are not. contracted. from view in.

NON-EXHIBITOR/Business MEMBERSHIP

TBA BUSINESS MEMBER BENEFITS MEMBERSHIP INFORMATION

2015 Exhibitor Handbook. This handbook including the attached booth rules are binding parts of the exhibitor agreement.

DISPLAY/BOOTH RULES AND REGULATIONS

September 29 October 1, 2013 Indiana Convention Center 100 South Capitol, Indianapolis, Indiana 46225

2016 Exhibitor Handbook. This document including the attached booth rules are binding parts of the Exhibitor Agreement.

Booth Design Guidelines

Booth Design Guidelines

Booth Construction. Installation & Dismantle. AAO 2016 Exhibit Prospectus

2018 Exhibitor Handbook. This document and the attached booth rules are binding parts of the Exhibitor Agreement.

BOOTH REGULATION VISUALS

NEW BOOTH PACKAGE SPECS + DECOR RULES

Example. *Please see the MODEX 2018 Rules and Regulations (attached) for full details on all rules and regulations.*

Stand construction regulations

2018 FUNERAL DIRECTORS CONVENTION AND EXPO EXHIBITOR RENTAL APPLICATION AND CONTRACT

Exhibitor Prospectus. Cardinal Health Retail Business Conference

SECTION 35 ANTENNAS AND TOWERS

EXHIBITOR MANUAL North Carolina State Fairgrounds

2010 ADA Standards Courtroom Requirements

Fire Safety During Construction, Tar Kettles, and Bituminous Melters

Estimated Cost of Project Contractor License No. Contractor Qualifier No.

Temporary Sign Permit

Welcome to the 25th Annual AMAT Conference

Tenant Sign Criteria. Guidelines. Requirements. Braelinn Village, Peachtree City

NAMES 2018 Exhibition Fair Guidelines

PALM SQUARE SHOPPING CENTER TENANT SIGN CRITERIA

Moline Illinois CODE OF ORDINANCES. Art. IX. Miscellaneous DIVISION 3. IN-BUILDING EMERGENCY RADIO SYSTEM COVERAGE

SUNSET & FRANCISQUITO SHOPPING CENTER S I G N P R O G R A M

The construction period is from February 26 th to March 5 th

TOWN OF NORTH BRANFORD

ACCESS TO HIGH VOLTAGE APPARATUS

Chapter 24 Outdoor Lighting Ordinance

THE HILLCREST VILLAGE HOMEOWNERS ASSOCIATION, INC. RULES FOR INSTALLATION OF ANTENNAS

Wall bracing is one of the most important structural elements of

Sec Radio, television, satellite dish and communications antennas and towers.

48 in. X 96 in. 500 Pound Capacity Motorized Overhead Storage Unit Installation Guide [OPTION B] MODEL # PRM4X8 Patent Pending

Transcription:

DISPLAY RULES AND REGULATIONS Please be sure to read the following information in its entirety and distribute to your staff and Exhibitor Appointed Contractors. These regulations will be strictly enforced. Display rules and regulations have been with us since expositions began. Each of us recognize the need for certain limitations but many have never taken the time to understand the intent of such rules, why the rules were written, what the rules are expected to accomplish and most importantly, how you as an exhibitor can use them effectively. The International Association for Exposition Management (IAEM) Guidelines for Display Rules and Regulations were created to promote continuity and consistency among North American exhibitions. Since their introduction, they have become the model for domestic shows. Please pay close attention to the height regulations for each booth type: Inline / Perimeter, Peninsula and Island. All line of sight regulations will apply for all exhibit space. The tenet on which all show management is based can be summed up as follows: All exhibitors are equal regardless of size and should be given an equal opportunity, within reason, to present their product in the most effective manner to the audience. Experience proves that exposition management must establish rules or guidelines to make this possible while allowing the greatest flexibility in each exhibit. The exhibitor s responsibility can be summed up far more simply: Be a good neighbor. Please review the rules and regulations outlined on the following pages. By following these regulations you can be reasonably sure you will always be a good neighbor. DIVERSIFIED BUSINESS COMMUNICATIONS 121, Free Street P.O. Box 7437 Portland, ME 04112-7437

Inline/Perimeter Booths An Inline or Perimeter Booth is open to the aisle on one or two sides and located along a straight line or on a perimeter wall of the exhibit floor. Dimensions Inline and Perimeter Booths will be ten feet (10 ) wide and eight feet (8 ) deep. Each booth will be set with an eight-foot (8 ) high back drape and two (2) 36 high side divider drapes. Use of space Display materials should be arranged in such a manner as not to obstruct sight lines of neighboring exhibitors. The maximum height of eight (8 ) feet is allowed only in the rear half of the booth space, with a four-foot (4 ) height restrictions imposed on all materials in the remaining space forward to the aisle. 10'- 0" Left Side Front Plan 10'-0" Aisle

Peninsula Booth A Peninsula Booth is exposed to aisles on three (3) sides and composed of a minimum of four booths. There are two types of Peninsula Booths: (a) one which backs up to Linear Booths, and (b) one which backs to another Peninsula Booth and is referred to as a Split Island Booth. Dimensions A Peninsula Booth is 16'x 20' or larger. When a Peninsula Booth backs up to two Linear Booths, the backwall is restricted to four feet (4') high within four feet (4') of each aisle and 10' out from the backwall, permitting adequate line of sight for the adjoining Linear Booths. In the Rhinelander Gallery, eight feet (8') is the maximum height allowance, including signage for the center portion of the backwall. In the Americas Hall 1, the maximum height allowance for the center portion of the backwall is twelve feet (12'). Backwall must be devoid of all graphics, text and logos and must be suitably finished. In the event that the adjoining exhibit is a booth peninsula area since (creating a peninsula a split island), booth adjoining display fixtures another will penisula be permitted booth does to a not maximum block the height neighboring of 8' - Rhinelander exhibit's line / 12' of -Americas sight within ates fro the IAEM, entire 2000 Update Published Guidelines. 2000 IAEM

Island Booth An island booth is exposed to aisles on all four sides. Dimensions An island booth is 16 x 20, although it may be configured differently. Use of space The entire cubic content of the space may be used up to the maximum allowable height, which is eight feet (8 ), including signage in the Rhinelander Gallery. In the Americas Hall, the maximum allowable height is twelve feet (12'), including signage. 16'- 0" 20'- 0" FRONT PLAN 8.0 AISLE ASILE AISLE AISLE

Issues Common To All Booth Types Americans with Disabilities Act (ADA) All exhibiting companies are required to be in compliance with the Americans with Disabilities Act (ADA) and are encouraged to be sensitive, and as reasonably accommodating as possible, to attendees with disabilities. Information regarding ADA compliance is available from the U.S. Department of Justice ADA Information Line (800-514-0301) and from web site www.usdoj.gov/crt/ada/infoline.htm. Structural Integrity All exhibit displays should be designed and erected in a manner that will withstand normal contact or vibration caused by neighboring exhibitors, hall laborers or installation/dismantling equipment such as fork lifts. Displays should also be able to withstand moderate wind effects that may occur in the exhibit hall when freight doors are open. Refer to local building codes that regulate temporary structures. Exhibitors should ensure that any display fixtures such as tables, racks or shelves are designed and installed properly to support the product or marketing materials to be displayed upon them. Flammable and Toxic Materials All materials used in display construction or decorating should be made of fire retardant materials and be certified as flame retardant. Samples should also be available for testing. Materials that cannot be treated to meet the requirements should not be used. A flameproofing certificate should be available for inspection. Exhibitors should dispose of any waste products they generate during the exhibition in accordance with guidelines established by the Environmental Protection Agency and the facility. Lighting Exhibitors should adhere to the following suggested minimum guidelines when determining booth lighting: No lighting, fixtures, lighting trusses or overhead lighting are allowed outside the boundaries of the exhibit space. Exhibitors intending to use hanging light systems should submit drawings to exhibition management for approval. Lighting should be directed to the inner confines of the booth space. Lighting should not project onto other exhibits or show aisles. Lighting which is potentially harmful, such as lasers or ultraviolet lighting, should comply with facility rules and be approved in writing by exhibition management. Lighting that spins, rotates, pulsates and other specialized lighting effects should be in good taste and not interfere with neighboring exhibitors or otherwise detract from the general atmosphere of the event. 2000 IAEM

Storage Fire regulations in most exhibit facilities prohibit storing product, literature, empty packing containers or packing materials behind back drapes or under draped tables. In most cases, however, exhibitors may store a limited supply of literature or product appropriately within the booth area, so long as these items do not impede access to utility services, create a safety problem or look unsightly. Demonstrations As a matter of safety and courtesy to others, exhibitors should conduct sales presentations and product demonstrations in a manner which assures all exhibitor personnel and attendees are within the contracted exhibit space and not encroaching on the aisle or neighboring exhibits. It is the responsibility of each exhibitor to arrange displays, product presentation and demonstration areas to ensure compliance. Special caution should be taken when demonstrating machinery or equipment that has moving parts, cooking equipment with an open flame, or any product that is otherwise potentially dangerous. Exhibitors should establish a minimum setback of three feet (3 ) and/or install hazard barriers as necessary to prevent accidental injury to spectators. Sound demonstrations should not exceed 85 decibels. Additionally, demonstrations should only be conducted by qualified personnel. Sound/Music In general, exhibitors may use sound equipment in their booths so long as the noise level does not disrupt the activities of neighboring exhibitors. Speakers and other sound devices should be positioned so as to direct sound into the booth rather than into the aisle. Rule of thumb: Sound and noise should not exceed 85 decibels. Exhibitors should be aware that music played in their booths, whether live or recorded, may be subject to laws governing the use of copyrighted compositions. ASCAP, BMI and SESAC are three authorized licensing organizations that collect copyright fees on behalf of composers and publishers of music. Fire Equipment Fire hoses and extinguishers should be visible and accessible at all times. 2000 IAEM