Akiyama-Probe (A-Probe) guide

Similar documents
Akiyama-Probe (A-Probe) guide

Akiyama-Probe (A-Probe) technical guide This technical guide presents: how to make a proper setup for operation of Akiyama-Probe.

Akiyama-Probe (A-Probe) simple DIY controller This technical guide presents: simple and low-budget DIY controller

easypll UHV Preamplifier Reference Manual

- Near Field Scanning Optical Microscopy - Electrostatic Force Microscopy - Magnetic Force Microscopy

Nanosurf Nanite. Automated AFM for Industry & Research.

Advanced Nanoscale Metrology with AFM

Outline: Introduction: What is SPM, history STM AFM Image treatment Advanced SPM techniques Applications in semiconductor research and industry

Basic methods in imaging of micro and nano structures with atomic force microscopy (AFM)

Keysight Technologies Using Non-Contact AFM to Image Liquid Topographies. Application Note

Electric polarization properties of single bacteria measured with electrostatic force microscopy

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

AFM of High-Profile Surfaces

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

Atomic Force Microscopy (Bruker MultiMode Nanoscope IIIA)

Study of shear force as a distance regulation mechanism for scanning near-field optical microscopy

MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY

ATOMIC FORCE MICROSCOPY

Prepare Sample 3.1. Place Sample in Stage. Replace Probe (optional) Align Laser 3.2. Probe Approach 3.3. Optimize Feedback 3.4. Scan Sample 3.

Constant Frequency / Lock-In (AM-AFM) Constant Excitation (FM-AFM) Constant Amplitude (FM-AFM)

Park NX-Hivac: Phase-lock Loop for Frequency Modulation Non-Contact AFM

Figure for the aim4np Report

Instructions for easyscan Atomic Force Microscope

Nanosurf easyscan 2 FlexAFM

Investigate in magnetic micro and nano structures by Magnetic Force Microscopy (MFM)

; A=4π(2m) 1/2 /h. exp (Fowler Nordheim Eq.) 2 const

NSOM (SNOM) Overview

Lateral Force: F L = k L * x

Cutting-edge Atomic Force Microscopy techniques for large and multiple samples

Nanonics Systems are the Only SPMs that Allow for On-line Integration with Standard MicroRaman Geometries

Indentation Cantilevers

Supporting Information

Scanning force microscopy in the dynamic mode using microfabricated capacitive sensors

Specifying and Measuring Nanometer Surface Properties. Alson E. Hatheway

LOW TEMPERATURE STM/AFM

Standard Operating Procedure of Atomic Force Microscope (Anasys afm+)

SPM The Industry s Performance Leader High Resolution Closed-loop System Fast, Easy Tip & Sample Exchange Versatility and Value Powerful Research

PROBLEM SET #7. EEC247B / ME C218 INTRODUCTION TO MEMS DESIGN SPRING 2015 C. Nguyen. Issued: Monday, April 27, 2015

queensgate a brand of Elektron Technology

Nanosurf easyscan 2 Your Modular Scanning Probe Microscopy System

Optical Microscope. Active anti-vibration table. Mechanical Head. Computer and Software. Acoustic/Electrical Shield Enclosure

Lecture 20: Optical Tools for MEMS Imaging

Microscopic Structures

Enabling Areal Density Growth

RHK Technology. Application Note: Kelvin Probe Force Microscopy with the RHK R9. ω mod allows to fully nullify any contact potential difference

Oxford Scholarship Online

Piezoelectric Sensors and Actuators

NANOSCOPIC EVALUATION OF MICRO-SYSTEMS

IMAGING P-N JUNCTIONS BY SCANNING NEAR-FIELD OPTICAL, ATOMIC FORCE AND ELECTRICAL CONTRAST MICROSCOPY. G. Tallarida Laboratorio MDM-INFM

MICRO YAW RATE SENSORS

Park NX-Hivac The world s most accurate and easy to use high vacuum AFM for failure analysis.

University of MN, Minnesota Nano Center Standard Operating Procedure

High-speed wavefront control using MEMS micromirrors T. G. Bifano and J. B. Stewart, Boston University [ ] Introduction

Part 2: Second order systems: cantilever response

Controller Design for Z Axis Movement of STM Using SPM Control Software

UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY

Comparison of resolution specifications for micro- and nanometer measurement techniques

SENSOR+TEST Conference SENSOR 2009 Proceedings II

Imaging Carbon Nanotubes Magdalena Preciado López, David Zahora, Monica Plisch

Optimal Preamp for Tuning Fork signal detection Scanning Force Microscopy. Kristen Fellows and C.L. Jahncke St. Lawrence University

Adaptive Optics for LIGO

Author(s) Issue Date Text Version author. DOI / /18/9/095501

Q-Motion Miniature Linear Stage

Nanoscale Material Characterization with Differential Interferometric Atomic Force Microscopy

P-810 P-830 Piezo Actuators

Last Name Girosco Given Name Pio ID Number

Manufacturing Metrology Team

WAVES. Chapter Fifteen MCQ I

SUPPLEMENTARY INFORMATION

A simple strobe to study high-order harmonics and multifrequency oscillations in mechanical resonators

XYZ Stage. Surface Profile Image. Generator. Servo System. Driving Signal. Scanning Data. Contact Signal. Probe. Workpiece.

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

January, 2004 Jeju Island. Acknowledgements OTFL

A scanning tunneling microscopy based potentiometry technique and its application to the local sensing of the spin Hall effect

A Project Report Submitted to the Faculty of the Graduate School of the University of Minnesota By

Fast Tip/Tilt Platform

Micro-nanosystems for electrical metrology and precision instrumentation

Rebirth of Force Spectroscopy: Advanced Nanomechanical, Electrical, Optical, Thermal and Piezoresponse Studies

Underground M3 progress meeting 16 th month --- Strain sensors development IMM Bologna

Available online at ScienceDirect. Procedia Computer Science 79 (2016 )

Characteristics of Crystal. Piezoelectric effect of Quartz Crystal

Near-field Optical Microscopy

Radial Polarization Converter With LC Driver USER MANUAL

School of Instrument Science and Opto-electronics Engineering, Hefei University of Technology, Hefei, China 2

Out-of-plane translatory MEMS actuator with extraordinary large stroke for optical path length modulation in miniaturized FTIR spectrometers

ISSCC 2006 / SESSION 16 / MEMS AND SENSORS / 16.1

LAB UNIT 1: Introduction Scanning Force Microscopy

PACS Nos v, Fc, Yd, Fs

ARCoptix. Radial Polarization Converter. Arcoptix S.A Ch. Trois-portes Neuchâtel Switzerland Mail: Tel:

Phase modulation atomic force microscope with true atomic resolution

Radio-frequency scanning tunneling microscopy

CAPACITIVE SENSORS. Series KS. Key-Features:

Magnetic Micro Testing System Microservo MMT Series C225-E014A

Physics Faculty Publications and Presentations

PIHera Piezo Linear Precision Positioner

Sensors and actuators at NXP: bringing more than Moore to CMOS

MICROMACHINED INTERFEROMETER FOR MEMS METROLOGY

Multi-Probe Atomic Force Microscopy Using Piezo-Resistive Cantilevers and Interaction between Probes

The World s Most Accurate AFM System. Park NX-3DM Innovation and Efficiency for 3D Metrology.

Transcription:

Akiyama-Probe (A-Probe) guide This guide presents: what is Akiyama-Probe, how it works, and its performance. Akiyama-Probe is a patented technology. Version: 2009-03-23

Introduction NANOSENSORS Akiyama-Probe (A-Probe) is a novel self-sensing and self-actuating (-exciting) probe based on a quartz tuning fork combined with a micromachined cantilever for dynamic mode AFM. The great advantage of this novel probe is that one can benefit from both the tuning fork's extremely stable oscillation and the silicon cantilever's reasonable spring constant with one probe. Akiyama-Probe is equipped with a high-end sharp silicon tip and has an excellent imaging capability on various samples with different properties, which is as high as a conventional optical lever system. Akiyama-Probe requires neither optical detection, nor external shaker. Akiyama-Probe occupies only a small space above the sample. These features make it very attractive for creating new generation SPM instruments.

Akiyama-Probe specifications ~ 3 mm w l The cantilever is electrically connected to one of the electrodes of the TF. Specifications (typical values) Cantilever Tip Force constant Resonance frequency Ceramic plate length: 310 µm, thickness: 3.7 µm, width: 30 µm each material: n + silicon (0.01-0.025 Ohm cm) AdvancedTEC -like tip radius <15 nm, tip height 28 µm 5 N/m (Si cantilever) ~ 50 khz approximately 6.5 mm x 5.1 mm x 0.4 mm All values are subject to change without notice.

Working principle (1) In-plane movement transformed Out-of-plane motion (tip vibration) In operation, the electrical driving signal is directly applied to the electrodes of the tuning fork (TF) to excite it at its lowest resonance. In this mode, the ends of the two prongs are moving in-plane and have opposite phases, meaning that they approach and withdraw from each other. The vibration amplitude is typically in the order of tens of nm. This motion applies a small vibration at the glued ends of the cantilever, which always contains a component in z-direction (i.e., the axis of the tip) due to the twisting motion of the prongs (i.e., the cantilever disturbs a symmetry of the TF). The cantilever amplifies the vibration according to its mechanical property and a large out-ofplane motion of the tip is obtained.

Working principle (2) The TF is used as an oscillatory force sensor similarly to a quartz microbalance. Its frequency and amplitude are influenced by those of the tip motion. Consequently, the tip-sample interaction can be electrically detected with the TF. The recommended operation mode for Akiyama-Probe is dynamic mode with the frequency modulation (FM) detection, where the TF is self-excited (oscillating) at its first resonance frequency. During sample imaging, the resonance frequency is tracked by a phase locked loop (PLL) and kept at a set value by adjusting the tip-sample distance with a feedback loop. Selfoscillation f 0 f 1 TF influence Dynamic mode AFM The amplitude modulation (AM) detection (fixed driving frequency) is also feasible, if one would accept a slower scan speed and compromise on spatial resolution. Akiyama-Probe is designed for operation in ambient conditions. It may work in other conditions, like vacuum, UHV, or low temperatures, etc.

Working principle (3) k2 c2 Resonance of TF before cantilever was glued 32.768 khz 1st resonance 2nd resonance m2 F k1 m1 c1 Optical detection of tip vibration Electrical signal from TF Main peak Frequency Sub peak Akiyama-Probe is a system with two coupled resonators that are moderately matched in terms of resonance frequency. The left figure illustrates a simplified model of Akiyama- Probe, where the cantilever corresponds to Resonator 1 (m1, k1, c1) and the TF to Resonator 2 (m2, k2, c2). F is the driving force created by the piezoelectric effect of the TF. Like with other similar systems, one obtains two typical resonances: in-phase (1st) and antiphase (2nd) peaks. By sweeping the driving frequency, the two large vibration peaks can be observed at the tip by optical means. In the electrical signal from the TF, one observes a large peak at the 1st resonance and a small, or almost none, peak at the 2nd resonance. The large peak at the 1st resonance is the operation frequency of Akiyama-Probe.

Approach curve Tip in contact, but TF is still oscillating Resonance Frequency Δf B Periodic contact A Tip oscillating in free space The figure shows a typical approach curve of Akiyama- Probe. The dashed line A indicates the critical point where the tip starts periodic contact on the sample surface. Beyond this point, the resonance frequency increases almost linearly as the tip is moved closer to the sample surface in the periodic contact region. Oscillation amplitude of the tip decreases linearly and the center of the vibration is shifted in this region (i.e., illustration at the bottom of the figure). Tip oscillation (optical observation) ΔZ The end of the periodic contact region is indicated by the dashed line B. Beyond this point, the probe works in a quasi contact mode, i.e., the tip remains in contact with the surface during the full oscillation cycle, whereas the cantilever is still vibrated by the TF. The maximum frequency shift obtained in the periodic contact region (denoted as Δf) is a specific and constant value for each probe. The distance ΔZ is about a half of the peak-to-peak amplitude of the tip oscillation in free space.

Approach curves One of the important features of Akiyama-Probe is that the maximum frequency shift Δf does not depend on the tip vibration amplitude. The figure shows three approach curves with different amplitude settings. It demonstrates Δf a = Δf b = Δf c. Δf a 1040 nm The sensitivity defined as the maximum frequency shift divided by the amount of tip displacement in the periodic contact region differs for each setting of the tip vibration amplitude. The sensitivity is increased as the tip vibration amplitude is decreased. Δf b 560 nm The range of Δf is approximately 30 Hz ~ 400 Hz. This is not guaranteed and subject to change without notice. Δf varies depending on temperature and humidity. Δf c 240 nm 80 nm/div

Long range approach curve Tip in contact, but TF is still oscillating Periodic contact Tip oscillating in free space Frequency shift Δf 13.3 µm Z position The figure shows a long range approach curve. The resonance frequency of the TF decreases gradually in the region of the quasi static mode. This region lies over a couple of tens µm in z-direction. Although Akiyama-Probe operated in this mode could be used for e.g. measuring displacement, the tip is strongly pushed onto the sample surface and, hence, operation in this mode is not recommended for AFM imaging.

Applications AFM imaging (topography, roughness) Measurement inside of channel Displacement measurement Light Combination with SEM/ optical microscope Multi-probe AFM imaging of light sensitive samples

AFM images with Akiyama-Probe IC chip (40 µm x 40 µm) Carbon nanotube (5 µm x 5 µm) PS/PMMA film (5 µm x 5 µm) Samples from Nanosurf AG. Akiyama-Probe vs. Optical lever Akiyama-Probe µm Std. 40 N/m Si lever Tapping mode on Veeco Nanoscope III, with Nanosurf easypll, by IMT Univ. of Neuchâtel Switzerland µm

Akiyama-Probe in SEM EMPA Switzerland Dr. Vinzenz Friedli, Focused electron- and ion-beam induced processes : in situ monitoring, analysis and modeling, disseration EPFL, no 4036 (2008).

AFM images Carbon nanotube Staphylococcus aureus bacteria Atomic steps on PbSnSe etch pits Topographic images taken under ambient conditions in intermittent contact mode using Akiyama-Probe with Nanosurf Nanite A100 A-Probe AFM

AFM image Plasmid-DNA (2,686 bp) Scan Size : 1x1 µm Topographic images taken under ambient conditions in intermittent contact mode using Akiyama-Probe with : SXM Standard (Research Institute of Biomolecule Metrology Co., Ltd., Japan)

THANK YOU FOR YOUR INTEREST

NANOSENSORS NANOSENSORS Rue Jaquet Droz 1 Case Postale 216 CH-2002 Neuchâtel Switzerland phone: +41 32 720 5085 fax: +41 32 720 5792 info@nanosensors.com www.nanosensors.com NANOSENSORS is a trademark of NanoWorld AG - Copyright by NanoWorld AG