OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from

Similar documents
ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

SKINTOP ÖLFLEX CLICK & VFD CLICK FLEX. Products for Variable Frequency Drive Applications. ake the right connection

ÖLFLEX 409 P. Heavy duty control cable with PUR jacket

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6

CIR (Crush & Impact Resistant) VFD Power Cable

Continuous Flex Data Cable

High Temperature Flexible Control Cable OLFLEX

High Temperature Flexible Control Cable

MachFlex Industrial Cables

Servo Cable Selection

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

TIGER BRAND MINING CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

EcoCable and EcoFlex Cable. Smaller. Lighter. 100% Recyclable.

GEXOL WORLD CLASS OIL & GAS CABLES

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500

Communication, Control, and Industrial Cable

ÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

EcoCable and EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

EcoCable and EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

DB EN valid from: Application SERVO LK SMS FX8PLUS SIGNAL

DLO Flexible Power Cable

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

THHN12STGN500 THHN 12 STR Green 500

THHN2BK2500 THHN 2 STR Black 2500

THE WORLD OF LAPP. Cables for power chains

14 AWG 2 AWG: 600 Volt

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)

For tough, seaworthy wire

Detailed Specifications & Technical Data

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

Low Voltage AIRGUARD. A proven, rugged product for harsh environments

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

Industrial Automation & Control Cables

Industrial Data. Conductor (stranding) Diameter Nom. DCR. Shielding Materials Nom. DCR. Color Code. (2)18 AWG TC Data Pair:

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

THE WORLD OF LAPP. Photovoltaic Solutions for the North American Market

Section 4. Multi-Conductor

ADVANCED FLAT CABLE SOLUTIONS

Instrumentation Cables

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

WIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable

WELCOME On-Line Catalog Features

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Detailed Specifications & Technical Data

Micro-Change. Cordset Family

3-10. General Quick Selection Introduction 3-Cordsets PannelConnect Safety. Connection. Network Media

TRAXLINE CABLES FOR MOTION

HELUKABEL UL-LISTED CABLES

Shielded Fire Alarm Cables

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

SIMpull THHN, it slips and slides - all with NoLube.

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

Amphenol. Advantage. R-Line R-146. Rectangular Attached Multi-Pin Industrial Cable Assemblies. Amphenol - Sine Systems

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

Airport Cables & Connectors

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

INTRODUCTION PRODUCT LINES GREEN ENERGY. In drive technology, the trend is towards ever more complex

IMSA TRAFFIC SIGNAL CABLE

AEE. Canada. Australia

Installation Solutions. Cable assemblies according to SIEMENS 6FX standard

Detailed Specifications & Technical Data

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry

Quality Commitment # #

Success Depends on the Crimp

Nexans Industrial Solutions PRODUCT CATALOG

The STrongeST Link to your SucceSS... From ViSion to FiniShed ProducT

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*)

MEDIUM VOLTAGE

FieldLink MC at 20 x outer diameter Torsion

QUICK REFERENCE. A-Size (7/8 ) powerfast. D-Size (1 3/8 ) powerfast. M16 powerfast. M23 powerfast. M40 powerfast. 3 & 4 pole 14 AWG conductors

Industrial Data Solutions Industrial Data DeviceBus for ODVA DeviceNet Cables

Selection table for flat & ribbon cables

HARTING Han-Power T Solutions

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*)

SpaceMaker Series Electronic Wire and Cable

Part Number: 7953A Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

BUS cable. BUS cable. Cables for use in automation- and communication technique.

Detailed Specifications & Technical Data

Multi-Paired Cable Product Finder

02 WIRE AND CABLE WIRE AND CABLE FILS ET CÂBLES ALAMBRES Y CABLES. Primary Wire Dispenser

SECTION Q WIRE AND CABLE Wilson Avenue, Toronto, Ontario, Canada, M9M 1A1 Ph: Fax:

MHR-2 Two Conductor Mini High Resolution S-Video Cable

Detailed Specifications & Technical Data

SUBMITTAL COVER SHEET

Transcription:

LAPP products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph:(10)358-3130 (800)638-1830 fx:(10)358-312 (800)872-9329 RFQ form: http://mdmetric.com/rfq.htm Flexible Tray Cable Lapp Index Page: http://mdmetric.com/elect/contents.htm 2 65

Flexible Tray Cable QUICK SELECT CHART 69 NEW TC 600/ 600 S 71 For Exposed Run, no conduit is needed TRAY II/ II CY 73 Flexible & Oil Resistant Tray Cable with both UL & CSA TC Approval for Industrial Applications AUTO-I 75 Heavy Duty, Flexible Control Cable with Colored for DC, AC or Control Wiring NEW SERVO TC 76 Tray Approved for Power and Signal For Longer Plant Cable Runs OTHER TRAY APPROVED CABLES IN OTHER CATALOG SECTIONS NEW NEW NEW NEW CONTROL TM/ TM CY Flexible and Oil Resistant Tray & Machine Cable UL MTW & UL/CSA TC Approval with Exposed Run for Industrial Applications CONTROL M 62 Flexible & Oil Resistant MTW Cable according to NFPA 79 CONTROL COLD 6 Flexible & Cold Temperature Tray Cable with UL/CSA -5 C Flexible/ -55 C Stationary POWER MULTI 63 Flexible & Oil Resistant Tray Cable and STOOW Extra Hard Service Cordage UNITRONIC 300 Series 15 Multi-Conductor Low Voltage Control & Signal Cable for Industrial Applications FD AUTO-X 9 Heavy Duty Continuous Flex Control Cable UL Type MTW Approved Cable VFD Slim 130 Reduced VFD Cable with Lapp Surge Guard UL & CSA TC Approval 66 Available from MARYLAND METRICS (800)638-1830 email: sales@mdmetric.com

Flexible Tray Cable VFD with Signal 132 Flexible VFD Cable with a Pair for Brake or Temperature Sensor VFD SYMMETRICAL 133 Oil Resistant Motor Supply Cable for Large HP VFD Drives with UL & CSA TC Approval FD VFD 13 Continuous Flex VFD Cable with UL & CSA TC Approval SDP TC 135 Severe Duty Power Cable, Bus Drop Cable Available from MARYLAND METRICS (800)638-1830 email: sales@mdmetric.com 67

QUICK SELECT CHART AWG Range Conductor Count Stranding TC 600 18-10 3,, 5, 6, 7, 9, 10, 12, 15, 16, 19, 7 & 19 Strand TC 600 S 18-10 3,, 5, 6, 7, 9, 10, 12, 15, 16, 19, 7 & 19 Strand TRAY II 18-500 KCMIL 3,, 5, 7, 8, 9, 12, 16, 18,, 1, 50, 61 TRAY II CY 18-500 KCMIL 3,, 5, 7, 12, 18, AUTO-I 18-16 3, 5, 7, 11, 12, 19,, 33, 2, 9, 65 30 AWG Stranding SERVO TC 18 - c 2 pair CONTROL TM/ TM CY 18-10 3,, 5, 6, 7, 9, 10, 12, 15, 19, 20, CONTROL M 18-2 3,, 5, 7, 9, 12, 18, 19,, 33 CONTROL COLD 18-2 3,, 5, 7, 9, 12, 16, 18, POWER MULTI 18-8 3,, 5, 7, 12, 18, UNITRONIC 300/ 300S 28-16 2, 3,, 6, 8, 10, 15, 20,, 30, 0, 50 FD AUTO-X 18-16 3, 5, 7, 11, 12, 19,, 33, 2, 9, 55 Class M VFD Slim 18-2 30 AWG Stranding VFD with Signal 16 - c 1pr 30 AWG Stranding VFD SYMMETRICAL 1-500 KCMIL 3c 3 symm grounds 19 & 30 Strand VFD FD 1-10 c Class 6 Superfine Stranding SDP TC 1-2 c * UNITRONIC 300 Wet Rating is based on Lapp Testing. 68 Available from MARYLAND METRICS (800)638-1830 email: sales@mdmetric.com

Shield Jacket Low Temp High Temp Oil Rating Flame Rating Motion Type Wet Rating Page # -0 o C 71-0 o C 71-0 o C 73-0 o C 73 - o C 75-0 o C 76 & -0 o C TPE -0 o C 105 o C 62-55 o C 6 TPE -0 o C 63 & - o C 15 TPE - o C 9 - o C 130 TPE - o C 105 o C 132-20 o C 133 TPE - o C 105 o C 13 TPE -0 o C 105 o C 135 Ultimate Excellent Superior Above Average Average OR- 05 0 03 02 01 FR- 05 0 03/3.1 02 01 Motion CF-03 CF-02 CF-01 FL-02 FL-01 Cable Attributes, See Page 653 Oil Resistance: OR Flame Resistance: FR Motion CF or FL Available from MARYLAND METRICS (800)638-1830 email: sales@mdmetric.com 69

Tray Cables from the Lapp Group The Lapp Group offers a complete line of UL TC-ER (Exposed Run)/CSA TC cables for all your application needs. Do It Without Conduit From industrial to commercial... From cold environments to hazardous environments... With either black, red, or yellow conductors... From control to power... From machine tools to factory installation... In either black or gray jackets... From 22 AWG to 500 KCMIL... For 300V to 600V max... For USA and Canada... Lapp Group, your one stop solution for all UL TC-ER (Exposed Run) & CSA TC cables 70 Available from MARYLAND METRICS (800)638-1830 email: sales@mdmetric.com

TC 600/ 600 S For Exposed Run, no conduit is needed TC 600 is a multi-conductor cable approved for use in cable trays. It is UL TC-ER & CSA CIC/TC approved making it perfect for new plant installations and factory expansion. TC 600 S has an overall foil tape and drain wire for EMI & RFI protection. Recommended Applications: Plant expansion, Contractor market, A & E firm plant designs, Tray wiring, Anywhere that VNTC cables are used Application Advantage: Easier to pull than standard tray cables, minimizing labor costs UL TC-ER approval to reduce material costs. conduit is needed. Black numbered conductors with printed color code for easy identification UV resistant and direct burial UL wet rating TC 600 Construction: Finely stranded bare copper conductors; specially blended /nylon insulation; specially formulated jacket. TC 600-(UL)TYPE TC-ER 90 C 600V---CSA CIC/TC AWM FT RoHS TC 600 S Construction: Finely stranded bare copper conductors; specially blended /nylon insulation; % shielding with foil tape and drain wire; specially formulated jacket. TC 600 S-(UL)TYPE TC-ER 90 C 600V---CSA CIC/TC AWM FT RoHS Cable Attributes, See Page 653 Oil Resistance: OR-01 Motion Type: FL-01 Flame Resistance: FR-03 Mechanical Properties: MP-03 Availability: Standard put-ups are ft, 0ft, 500ft, and 1,000ft. Bulk reels can be cut to length. Complete the installation with: SKINTOP Strain Relief: Page 86 Tubing: Page 56 EPIC Connectors: Page 1 Servo TC: Page 75 Additional color code for the conductors and jacket available upon request. Minimums may apply. Technical Data: Minimum Bending Radius for installation: 6 x cable diameter for shielded: 8 x cable diameter Temperature Range: minal Voltage: Test Voltage: -0 o C to UL AWM 600V - TC 0V - TC Wind Turbine (WTTC) 2000V Approvals: UL: - Type TC-ER (Exposed Run) - UL AWM, UL Wet Rating 75 C - UL Type MTW, NFPA 79 2007 (1 AWG and larger) - Class 1, Div. 2 per NEC Art. 336, 392, 501 - Bus Drop- 1 AWG & Larger; 3c & c only CSA: - c(ul) CIC/TC FT - CSA-AWM I/II A/B FT Color Code: are black printed with white numbers and color name per color chart ICEA-NEMA (K-2) plus green/yellow ground Please note that VNTC is a trademark for General Cable Technologies Corporation. ** Meets UL Bus Drop Approval Available from MARYLAND METRICS (800)638-1830 email: sales@mdmetric.com 71

TC 600/ 600 S For Exposed Run, no conduit is needed. TC 600: Flexible Tray Cable 18 AWG (7 strand) 1.00 mm 2 211802 2 211803 3 21180 211805 5 211807 7 211809 9 211810 10 211812 12 211815 15 211819 19 2118 16 AWG (7 strand) 1.32 mm 2 211602 2 211603 3 21160 211605 5 211606 6 211607 7 211609 9 211610 10 211612 12 211616 16 211619 19 211620 20 2116 1 AWG (19 strand) 2.08 mm 2 21102 21103** 2110** 21105 21106 21107 2 3 5 6 7.273.287.310.335.361.16.9.62.511.569.68.295.311.337.36.39.39.55.93.508.59.62.655.718.3.33.373.05.39.39 6.9 7.3 7.9 8.5 9.2 10.6 11. 11.7 13.0 1.5 16.6 7.5 7.9 8.6 9.3 10.0 10.0 11.6 12.5 12.9 15.1 15.9 16.6 18.2 8.3 8.7 9.5 10.3 11.2 11.2 13 16 21 27 37 8 53 6 80 101 133 18 3 2 51 59 76 85 101 135 161 169 211 30 0 5 67 81 9 2 55 6 75 97 109 115 166 207 263 312 52 67 80 95 123 123 166 18 213 26 286 301 312 65 8 10 12 16 16 TC 600 S: Shielded Flexible Tray Cable 18 AWG (7 strand) 1.00 mm 2 211802S 2 211803S 3 21180S 211805S 5 211807S 7 211809S 9 211810S 10 211812S 12 211815S 15 211819S 19 2118S 16 AWG (7 strand) 1.32 mm 2 211602S 2 211603S 3 21160S 211605S 5 211606S 6 211607S 7 211609S 9 211610S 10 211612S 12 211616S 16 211619S 19 211620S 20 2116S 1 AWG (19 strand) 2.08 mm 2 21102S 21103S** 2110S** 21105S 2 3 5.276.290.313.338.36.19.52.65.51.572.651.298.31.30.367.397.397.58.96.511.597.627.658.721.328.36.376.08 7.0 7.3 7.9 8.5 9.2 10.6 11. 11.7 13.0 1.5 16.6 7.6 7.9 8.6 9.3 10.0 10.0 11.6 12.6 12.9 15.1 15.9 16.6 18.2 8.3 8.7 9.5 10.3 13 16 21 27 37 8 53 6 80 101 133 18 3 2 51 59 76 85 101 135 161 169 211 30 0 5 67 63 82 95 112 1 162 171 27 308 391 6 77 119 11 183 183 27 273 317 366 26 8 6 96 1 155 185 2 2 57 66 77 112 118 171 213 271 321 5 69 82 98 127 127 171 190 219 3 295 310 321 67 87 107 128 65 8 98 115 18 167 176 317 03 78 80 103 123 15 188 188 281 327 377 39 61 78 129 160 191 9 10 12 16 19 21109 21110 21112 21116 21119 211 12 AWG (19 strand) 3.30 mm 2 211202 2 211203** 3 21120** 211205 5 211206 6 211207 7 211209 9 211212 12 211216 16 211219 19 211220 20 2112 10 AWG (19 strand) 5.32 mm 2 212 2 213** 3 21** 215 5 217 7 219 9 211012 12 211019 19 8 AWG (19/.0295) 13.2 mm 2 21080 6 AWG (19/.0372) 8.38 mm 2 21060 6 7 9 10 12 16 19 21106S 21107S 21109S 21110S 21112S 21116S 21119S 211S 12 AWG (19 strand) 3.30 mm 2 211202S 2 211203S** 3 21120S** 211205S 5 211206S 6 211207S 7 211209S 9 211212S 12 211216S 16 211219S 19 211220S 20 2112S 10 AWG (19 strand) 5.32 mm 2 212S 213S** 21S** 215S 217S 219S 211012S 211019S 2 3 5 7 9 12 19.510.585.602.665.699.807.363.38.19.56.96.96.610.681.75.79.835.960.39.66.511.591.62.78.839 1.02.93 1.101 13.0 1.9 15.3 16.9 17.8 20.5 9.2 9.8 10.6 11.6 12.6 12.6 15.5 17.3 19.2 20.2 21.2 2. 11.2 11.9 13.0 15.0 16.3 19.0 21.3 26.0 2.0 28.0.2.2.513.588.605.668.702.810.366.387.22.59.99.99.613.68.757.797.883.963.22.69.51.59.65.751.82 1.027 11.2 11.2 13.0 1.9 15.3 16.9 17.8 20.5 9.3 9.8 10.6 11.6 12.6 12.6 15.5 17.3 19.2 20.2 21. 2. 11.2 11.9 13.0 15.0 16.3 19.0 21.3 26.0 121 135 162 215 6 337 50 6 86 107 128 150 192 7 32 06 28 535 7 102 136 170 238 306 08 66 393 81 9 121 135 162 215 6 337 50 6 86 107 128 150 192 7 32 06 28 535 7 102 136 170 238 306 08 66 218 22 298 373 50 569 85 111 18 181 0 32 360 32 50 68 720 900 18 193 7 307 30 59 737 1178 597 838 32 360 3 555 670 87 127 165 220 269 372 82 536 63 80 1018 1071 1339 220 287 382 57 60 817 1097 1753 888 1297 169 169 2 29 307 38 6 586 89 11 152 186 8 33 371 5 556 705 72 927 15 199 265 316 3 565 759 1213 1 1 33 371 56 572 690 872 132 170 227 277 383 96 552 662 828 109 1103 1379 229 296 393 71 659 82 1130 1806 72 Available from MARYLAND METRICS (800)638-1830 email: sales@mdmetric.com

TRAY II/ II CY Flexible & Oil Resistant Tray Cable with both UL & CSA TC Approval for Industrial Applications Tray II is an industrial grade tray cable with superior oil performance for long cable life. It has a pressure extruded jacket and fine copper stranding for excellent flexibility making it much easier to pull through tray. With UL TC-ER approval, no conduit is needed so you can reduce material costs along with saving on labor. Recommended Applications: Industrial plant expansions, Automotive plants, Tray wiring, anywhere that VNTC cables are used Application Advantage: Oil resistant pressure extruded jacket for improved flexibility Easier to pull than standard tray cables minimizing labor costs UL TC-ER approval to reduce material costs. conduit is needed. Black numbered conductors for easy identification UV resistant and direct burial UL wet rating TRAY II Construction: Finely stranded bare copper conductors; specially blended /nylon insulation; specially formulated oil resistant black jacket. TRAY II -(UL)TYPE TC-ER OR DP-I 90 O C 600V---c(UL) TC/CIC FT--CSA AWM FT RoHS TRAY II CY Construction: Finely stranded bare copper conductors; specially blended /nylon insulation; % shielding with foil tape and tinned copper braid (70% coverage); specially formulated oil resistant black jacket TRAY II CY-(UL)TYPE TC-ER OR DP-I 90 O C 600V---c(UL) TC/CIC FT--CSA AWM FT RoHS MSHA Cable Attributes, See Page 653 Oil Resistance: OR-02 Motion Type: FL-01 Flame Resistance: FR-03 Mechanical Properties: MP-03 Availability: Standard put-ups are ft, 0ft, 500ft, and 1,000ft. Bulk reels can be cut to length. Complete the installation with: SKINTOP Strain Relief: Page 86 Tubing: Page 56 EPIC Connectors: Page 1 Servo TC: Page 75 Additional color code for the conductors and jacket available upon request. Minimums may apply. Jacket is dual printed with AWG/mm 2 equivalent. Technical Data: Minimum Bending Radius for installation: < 1 AWG: 5 x cable diameter > 1 AWG: 7.5 x cable diameter Temperature Range: minal Voltage: Conductor Stranding: -0 o C to UL/CSA TC -0 o C to UL AWM 600V - TC 0V - AWM 0V - TC Wind Turbine (WTTC) Fine wire Color Code: Please note that VNTC is a trademark for General Cable Technologies Corporation. Black with white numbers plus green/yellow ground Approvals: UL: - Type TC-ER (Exposed Run) or DP-1 - UL AWM, Oil Res I, Wet Rating UL 83 - UL MTW, NFPA 79 2007 - Class 1, Div. 2 per NEC Art. 336, 392, 501 - Submersible pump (1 AWG & Larger: 2 to 7 conductors) CSA: Additional: - c(ul) Type TC and CIC FT - CSA-AWM I/II A/B FT - MSHA-P-07-KA050016-MSHA (Shielded Only) Available from MARYLAND METRICS (800)638-1830 email: sales@mdmetric.com 73

TRAY II/ II CY Flexible & Oil Resistant Tray Cable with both UL & CSA TC Approval for Industrial Applications Tray II: Flexible and Oil Resistant Tray Cable 18 AWG (19/30) 1.00 mm 2 221803 3 22180 221805 5 221807 7 221809 9 221812 12 221818 18 2218 221850 50 16 AWG (28/30) 1.50 mm 2 221603 3 22160 221605 5 221607 7 221608 8 221609 9 221612 12 221616 16 221618 18 2216 22161 1 221650 50 221661 61 1 AWG (6/30) 2.50 mm 2 22103 3 2210 22105 5 22107 7 22109 9 22112 12 22118 18 221 12 AWG (56/.0117) mm 2 22120 221205 221207 5 7.297.320.36.373.29.77.587.66.939.3.351.381.12..76.565.621.652.71.986 1.08 1.085.362.392.27.63.571.636.737.886.60.503.581 7.5 8.1 8.8 9.5 10.9 12.1 1.9 16.9 23.9 8.3 8.9 9.7 10.5 11.3 12.1 1. 15.8 16.6 18.8.0 26.6 27.6 9.2 10.0 10.8 11.8 1.5 16.2 18.7 22.5 11.7 12.8 1.8 19 31 56 75 113 156 313 27 36 5 6 73 82 109 15 163 227 372 5 553 5 60 75 105 135 179 269 37 1 176 57 66 77 112 171 322 66 69 83 98 127 136 171 220 271 289 397 6 760 769 87 107 128 169 2 308 39 587 152 187 8 85 98 115 19 167 5 365 79 961 103 12 16 189 203 5 328 03 31 592 931 1132 118 130 159 191 2 335 59 65 87 226 279 38 10 AWG (82/.0117) 6 mm 2 22 2 5 227 7 8 AWG (7/.0159) 10 mm 2 22080 220805 5 6 AWG (119/.0159) 16 mm 2 220603 3 22060 220605 5 AWG (182/.0) mm 2 22003 3 2200 2 AWG (273/.0) 35 mm 2 220203 3 22020 1 AWG (836/30) 2.3 mm 2.578.631.686.703.772.776.899.982.999 1.09 1.155 1.272 22010 1.00 1/0 AWG (105/30) 52.9 mm 2 22110 1.66 2/0 AWG (1330/30) 67.3 mm 2 22220 1.67 3/0 AWG (1672/30) 8.8 mm 2 22330 1.695 /0 AWG (2107/30) 106.7 mm 2 220 2.059 0 KCMIL (33 x 19/2) 128. mm 2 220 2.167 350 KCMIL (2 x 37/2) 181.9 mm 2 22350 2.501 500 KCMIL (3 x 37/2) 7.6 mm 2 200 2.902 1.7 16.0 17. 17.9 19.6 19.7 22.8 2.9.3 27.8 29.3 32.3 35.6 37.2 2.5 3.1 52.3 55.0 63.5 73.7 17 18 7 306 295 393 91 06 51 60 853 1096 13 1777 25 2839 331 687 6615 265 317 3 12 518 62 580 7 918 952 1169 139 1978 2195 2750 3717 69 5102 5578 7090 39 72 661 615 771 688 86 1080 1367 118 171 2077 297 3271 098 5538 699 7602 8311 1056 Tray II CY: Shielded Flexible and Oil Resistant Tray Cable 18 AWG (19/30) 1.00 mm 2 2218030 3 221800 2218050 5 2218070 7 2218120 12 2218180 18 22180 16 AWG (28/30) 1.5 mm 2 2216030 3 221600 2216050 5 2216070 7 2216120 12 2216180 18 22160 1 AWG (6/30) 2.5 mm 2 221030 22 221050 3 5.322.36.371.398.508.618.695.350.376.06.3.596.683.772.387.23.58 8.2 8.8 9. 10.1 12.9 15.7 17.7 8.9 9.6 10.3 11.3 15.1 17.3 19.6 9.8 10.7 11.6 21 35 2 56 96 138 190 38 8 59 82 13 196 261 57 78 93 80 92 130 222 29 386 97 116 127 165 286 36 76 121 150 180 The zero at the end of the part number denotes foil and braid shielding. 119 137 19 193 330 38 57 1 173 189 26 26 515 708 180 223 268 7 12 18 221070 221120 221180 2210 12 AWG (56/.0117) mm 2 221200 2212050 5 2212070 7 10 AWG (82/.0117) 6 mm 2 220 20 5 2270 7 8 AWG (7/.0159) 10 mm 2 220800 6 AWG (119/.0159) 16 mm 2 220600 AWG (182/.0) mm 2 22000 2 AWG (273/.0) 35 mm 2 220200.9.667.768.917.91.568.612.609.662.717.737.918 1.127 1.309 12.5 16.9 19.5 23.3 12.5 1. 15.5 15.5 16.8 18.2 18.7 23.3 28.6 33.2 1 208 303 26 121 151 201 173 211 291 279 35 613 95 220 00 527 70 212 261 335 371 12 575 576 812 1332 1951 327 595 78 108 315 388 99 552 613 856 857 1208 1982 2903 7 Available from MARYLAND METRICS (800)638-1830 email: sales@mdmetric.com

AUTO-I Heavy Duty, Flexible Control Cable with Colored for DC, AC or Control Wiring AUTO-I is a UV resistant, multi-conductor cable designed for use on Machine Tool Equipment and other industrial machinery conforming to NFPA 79 2007 wiring norms. AUTO-I is color coded with either blue, red, yellow, orange or black conductors for DC, AC or control wiring. Recommended Applications: Machine Tool machinery, Food & Beverage, Processing equipment, Automotive and Machine wiring for conformance to NFPA 79 2007 AUTO-I (UL) TC-ER OR MTW 90 O C 600V --- CSA CIC/TC AWM FT RoHS Application Advantage: Industrial grade jacket (Oil Res I) Conforms to NFPA 79 2007 standards for wiring machinery UL TC-ER, MTW & CSA CIC/TC approved coded for easy wiring with either black, blue, red, orange or yellow conductors AUTO-I Construction: Finely stranded bare copper conductors; specially formulated /nylon insulation; specially formulated gray jacket. Cable Attributes, See Page 653 Oil Resistance: OR-02 Motion Type: FL-01 Flame Resistance: FR-03 Mechanical Properties: MP-03 Jacket is dual printed with AWG/mm 2 equivalent. Minimums may apply. Availability: Standard put-ups are ft, 0ft, 500ft, and 1,000ft. Bulk reels can be cut to length. Complete the installation with: SKINTOP Strain Relief: Page 86 Tubing: Page 56 EPIC Connectors: Page 1 VFD Slim: Page 130 Additional color code for the conductors and jacket available upon request. Technical Data: Minimum Bend Radius for installation: Temperature Range: minal Voltage: 5 x cable diameter - o C to 600V 0V - TC Wind Turbine (WTTC) Approvals: UL: - Type TC-ER (Exposed Run) - Type MTW, NFPA 79 2007 - Oil Res. I, UL Wet Rating - Class 1 Div. 2 per NEC Art. 336, 392, 501 CSA: - c(ul) CIC/TC FT - AWM I/II A/B FT Color Code: Red (R), Blue (B), Black (BK), or Yellow (Y) or Orange (O) with black numbers, plus green/yellow ground (Black cond. has white numbers) >7c - For blue:. 2 cond. is white with blue stripe - For red:. 2 cond. is white, plus grn/yell gnd - For yellow:. 2 cond. is white, plus grn/yell gnd - For orange:. 2 cond. is white, plus grn/yell gnd 18 AWG (19/30) 1.00 mm 2 (BLUE) 1803IB 1805IB 1807IB 1811IB 1812IB 1819IB 18IB 1833IB 182IB 189IB 1865IB 3 5 7 11 12 19 33 2 9 65.297.36.373.63.77.583.677.736.818.908 1.011 7.5 8.7 9. 11.8 12.1 1.8 17.2 18.7 20.7 23.0.6 19 31 69 75 119 156 206 263 306 07 57 77 157 171 322 397 510 620 726 85 115 19 23 5 378 79 590 758 917 102 16 AWG (26/30) 1.32 mm 2 (BLUE) 1603IB 3.323 8.2 1607IB 7.09 10. 1611IB 11.51 13.7 1612IB 12.557 1.1 1617IB 17.638 16.1 1619IB 19.63 16.3 16IB.737 18.7 1633IB 33.816 20.7 162IB 2.950 2.1 169IB 9 1.005.5 1665IB 65 1.123 28.5 Replace the B at the end of the P/N with R for red conductors, Y for yellow conductors, BK for black conductors or O for orange conductors 27 6 109 15 172 227 299 381 5 590 65 1 202 220 9 285 397 510 6 760 890 97 186 301 3 379 2 590 758 936 1132 1326 Available from MARYLAND METRICS (800)638-1830 email: sales@mdmetric.com 75

SERVO TC Tray Approved for Power and Signal For Longer Plant Cable Runs SERVO TC is a power cable with two shielded pairs for signal/ feedback. It is UL TC-ER and CSA CIC/TC making it approved for tray. SERVO TC has an overall shield for EMI & RFI protection. Recommended Applications: Plant expansion, Contractor market, A & E firm plant designs, Tray wiring, Anywhere that VNTC cables are used Application Advantage: Tray Approved Servo Cable Oil Resistant Jacket TC-ER Approved so no conduit is needed With Tray approval, it is perfect for long runs from a cabinet to the machine Meets NFPA 79 2007 Machine Wiring Standard SERVO TC Construction: Bare copper conductors; specially blended /nylon insulation; pairs have a foil shield and drain wire, overall foil shield with drain wire; specially formulated jacket. SERVO TC-(UL)TYPE TC-ER 90 C 600V---c(UL) CIC/TC CSA AWM FT RoHS Cable Attributes, See Page 653 Oil Resistance: OR-02 Motion Type: FL-01 Minimums may apply on 18, 8, 6 & AWG Flame Resistance: FR-03 Mechanical Properties: MP-03 Availability: Standard put-ups are ft, 0ft, 500ft, and 1,000ft. Bulk reels can be cut to length. Complete the installation with: SKINTOP Strain Relief: Page 86 Tubing: Page 56 EPIC Connectors: Page 1 VFD Slim: Page 130 Jacket is dual printed with AWG/mm 2 equivalent. Technical Data: Minimum Bend Radius for installation: Temperature Range: minal Voltage: Test Voltage: 10 x cable diameter -0 C to 90 C 600V- TC 0V- TC Wind Turbine (WTTC) 2000V Color Code: Three black conductors with white numbers, plus green/yellow ground and two black pairs with white numbers (&5, 6&7) Approvals: UL: - Type TC-ER (Exposed Run) - UL AWM, UL Wet Rating 75 C - Class 1, Div. 2 per NEC Art. 336, 392, 501 - Type MTW, NFPA 79 2007 - UL Bus Drop- 1 AWG & Larger CSA: - c(ul) CIC/TC FT - AWM I/II A/B FT, CIC/TC Description 2 pairs for signal shielded 18 AWG (19/30) 1.00 mm 2 751808 18/c 18/2pr. 16 AWG (28/30) 1.50 mm 2 751608 16/c 18/2pr. 1 AWG (6/30) 2.50 mm 2 75106 1/c 16/2pr. 12 AWG (56/.0117) mm 2 751206 12/c 16/2pr. 10 AWG (8/.0117) 6 mm 2 756 10/c 16/2pr. 8 AWG (7/.0159) 10 mm 2 750806 8/c 16/2pr. 6 AWG (119/.0159)16 mm 2 750606 6/c 16/2pr. AWG (13/30) mm 2 75006 /c 16/2pr. 18 AWG (19 Strand) 18 AWG (19 Strand) 16 AWG (19 Strand) 16 AWG (19 Strand) 16 AWG (19 Strand) 16 AWG (19 Strand) 16 AWG (19 Strand) 16 AWG (19 Strand).61.83.551.588.656.770.879 1.082 11.5 12.0 13.7 1.7 16. 19.3 22.1 27.2 6 88 110 172 220 329 91 661 98 12 178 222 05 626 868 131 16 185 265 330 603 932 1292 1955 76 Available from MARYLAND METRICS (800)638-1830 email: sales@mdmetric.com