that HCG drops are very easy to use and can be taken right away, however, they must be taken several times a day.

Similar documents
i-stat 1 TESTING Training Guide

Learning to use your easypod. [somatropin (rdna origin) for injection]

USING ABSOLUTE BLACK INKS FOR MAKING SCREEN POSITIVES ON THE EPSON STYLUS PRO 3800 & 3880

Using Your Chip Priming Station

Alginate 3D Cell Culture Kit

Fotospeed PROFESSIONAL INKJET MEDIA & INKS. Instructions. Tubeless INKFLOW for Epson SC-P600. Fotospeed 4K Vivid Inks from new

The Synergy Opportunity Marketing Action Plan

USING ABSOLUTE BLACK INKS FOR MAKING SCREEN POSITIVES ON THE EPSON STYLUS PRO 4900

Sample Collection Instruction Booklet Stage 2 THE BART S OXFORD (BOX) FAMILY STUDY: Understanding the causes of type 1 diabetes

Page 1. Center for Environmental Health Sciences, MIT NIEHS Community Outreach and Education Program Core Center Award P30-ES 02109

HP 564 and 920 InkJet Cartridges Refill Instructions (Professional Version)

chemagic mrna Direct Kit

pluribead KIT Cell Separation Protocol M-Bead

ACQUITY APC Calibration Standards

mi-mag mrna Isolation Kit

Polymers and Enzymes Chemical Principles II Lab Week 2: January 27 30, 2003

THE WILLIAMSWARN BOTTLER USER MANUAL

Colorfil INSTRUCTIONS

Directions for running IC samples on the Shimadzu TOC analyzer. (5/18/2015 DER)

Corrie Moreau Page 1 7/23/10

Total RNA Isolation. User Manual. NucleoMag 96 RNA MACHEREY-NAGEL. January 2010 / Rev. 02

Solutions for purifying nucleic acids by solidphase reversible immobilization (SPRI)

Quick Start Learning Guide For LabColors Cosmetic Dyes

Experiment 6: Paper Chromatography

Technical data sheet. Encapsulator B-390 / B-395 Pro

Installation Instructions: Epson 1430 CFS

A three-dimensional (3D) cell culture kit using alginate gel.

Using Your Chip Priming Station

Step 01. Decide what your talents are Everybody in life has developed certain talents and skills that could and probably.

Black 22 Cyan 10 Magenta 10 Yellow 10

th St N Suite 113 Largo, FL (888) (888) Fax

CHROMATOGRAPHY. 1. Place about 5 drops of blue food color in a disposable plastic cup, a small glass container or on a glass or ceramic plate.

SC One Piece Connectors Termination Procedure Series: 728-NNN0-NNN0N

FROM THE GLASS TUBE TO OPTIMUM SYSTEM PACKAGING

Processing of Non-Metals Prof. Dr. Inderdeep Singh Department of Mechanical and Industrial Engineering Indian Institute of Technology, Roorkee

welcome to the PARTY

Published by Ginger Davis Allman

REFILLABLE CARTRIDGE SYSTEM FOR THE EPSON STYLUS PRO 4900

What s in your experiment kit:

COM-300 ph / EC / TDS / TEMP METER

Gerresheimer CAPITAL MARKETS DAY 2010

NEULOG CALCIUM ION LOGGER SENSOR GUIDE

What The Heck Is Mind Mapping?

CTC Analytics Service Note August 2016 PAL3: Design change for Tools

AdnaTest EMT-1/StemCellSelect

PERCEPTOL, ID-11 AND MICROPHEN FILM DEVELOPERS

AdnaTest OvarianCancer-2 Select

BASICS OF HERBALISM 10 Alyse Rothrock 2007

We want to thank and acknowledge the authors for sharing this protocol and their contributions to the field.

30 Plex Human Luminex (Invitrogen Kit, Single Plate)

MS - VERSATILE INSTRUCTION MANUAL

GARDEN IN A GLOVE. Supplies. What to do. disposable glove permanent marker 5 cotton balls water 5 different kinds of seeds craft stick pipe cleaner

KODAK PROFESSIONAL HC-110 Developer

TITLE: GUIDELINES FOR SAMPLE COLLECTION U + B

Fig. 1. A. Adjustable section of film holder. B. Notched portion. C. Projection guides. D. Back stop

Jars & Closures

How to build a hockey stick chair

KODAK HC-110 Developer

EMO. Service Instruction. created by Frank Weithöner. Table of contents: Special Tools Assembling Mixing Chamber

MabeWithLove.WordPress.com

INSTRUCTION MANUAL DISSOLVED OXYGEN-METER MODEL CDO-01

INSTRUCTION MANUAL Milwaukee Lab Photometer Mi490 Peroxide value

The FDA monitors all recalls and provides information via the FDA s weekly Enforcement Report (summarized below).

MEDICINES CONTROL COUNCIL

Investigating Water. DELTA SCIENCE READER Overview Before Reading Guide the Reading After Reading

Epson T069 Refillable Cartridges

Preparation of a Liquid Crystal Pixel

MEDIP-SEQUENCING PROTOCOL

CUSTOM-BUILT LUMINESCENCE BOX USER GUIDE

Guardian Sensor (3) User Guide

DNA extraction Protocol for Agencourt Genfind v2 Blood and Serum Genomic DNA Isolation Kit

TOOLS & SUPPLIES (Included in ProTops Tool Kit)

Tools Needed 3/32 Allen Wrench which is located in your accessory kit Masking Tape

Soap Dispenser Vertical Model: SD-V

Installation Instructions

Activities for Kids that Combine Art and Science

Instruction for applying the Logo Decals

An inexpensive and easy to make µl re-pipette

M-Beads Magnetic silica beads DNA 3.0 (COOH) Order #: PR-MAG00078 & PR-MAG00079

SeeMeCNC Guides. Step 2. REV2 Rostock Max v3 Base Assembly. Second edition Rostock Max v3 assembly guide. Written By: JJ Johnson

Gastight Syringes. A guide to syringe terminations and needle points can be found on page Series

[00:03:00] There is another movement, which is essentially the pupils of the eyes expanding and contracting.

PTFE Tip, Gas-Tight Syringes

PROFILES Teaching Material Material for Teachers

How to install an aftermarket stereo/navigation

E3 UV-30 Resist Film Instructions

Celerity Fiber Termination Kit

Bang! Zoom! Off to the Moon!

QUICK REFERENCE INSTRUCTIONS For use with the Sofia Analyzer only.

break down on their own. (They are usually non-biodegradable.) Once we make them,

Darkroom printing. Pictionary_tutorial

Lesson 4: Develop and Launch an Engaging Website

Guide for Casting Titanium with SuperCast Contents

How To Make A Two Part Mold And Cast Crystal Clear Medieval Knight Action Figures.

Boondocking is a computer game about street smarts and frugality players must master the art of living out of one s car in order to survive.

pure. precise. perfect.

Clear jammed paper from the input tray Remove any jammed paper that is accessible from the input tray area.

Go back to the stopped deck. Put your finger on it, holding it still, and press start. The deck should be running underneath the stopped record.

Smartlamp SINGLE LED Kit - Construction Manual

UPHO. ULTIMATE SAMPLE HOMOGENIZER cell disruption - user guide

Transcription:

that HCG drops are very easy to use and can be taken right away, however, they must be taken several times a day. 59

Injection Procedure Video Link== http://www.youtube.com/watch?v=r4sqwzisixk How to Mix 5000IU S of HCG for 200IU Daily Injection Take out the supplies you will need in order to follow these instructions: 1. 30ml bacteriostatic water 2. 10ml clear bottle 3. HCG vial 4. 5ml syringe and mixing needle alcohol pads First, you need to put together the supplies listed above in order to complete the mixing instruction. You need to have a 10-ml clear mixing bottle. This is your mixing bottle. You need your bacteriostatic water and you are going to have a mixing needle with 5ml s or larger. You will also have alcohol swabs to use to clean the surfaces of all of your supplies. Use it to clean the surfaces of the ampoules and mixing bottle and bacteriostatic bottles. You can remove the sodium chloride that comes with your HCG, because you don t really need it, you can take it out and put it to the side. 60

Your HCG usually comes with a little red or blue cap on it, or it may also come in ampoules. Snap the lid off and you will see a white substance, or little white pellet in there and that is your HCG. Genuine HCG comes usually in this powder form. Sometimes the supplier will send you a premixed liquid form, which is mixed with a 1-ml solution also inside this size bottle, but it is still in the powder form to begin with. Just so you know this is what it looks like. Overview-1 ml of bacteriostatic water; I m going to inject it into this small HCG bottle to dilute the pellet of HCG then extract the 1ml mixed solution of HCG from the small vial and add it to the 10ml clear vial. Then you re going to add 4 more ml of bacteriostatic water. 5000IU s of HCG to 5 ml of bacteriostatic water, 5 to 5, very is easy to remember. Here are the steps that you need to take: 1. First, clean the surfaces all of your mixing bottles, right now. Let s go ahead and just make sure that everything is sterile. By cleaning all these areas to begin with you ll know that you are using a clean and sterile surface. 61

2. This would be a brand new needle, go ahead and use that. You are going to take 1 ml of water from the BAC bottle, and add it to your HCG vial. Gently swirl your mixture to make sure all of your HCG has been dissolved. You re going to pressurizes this bottle and make it easier to extract the HCG from the vial and fill your syringe. 3. Extract all the HCG as much as you can, try and get every drop of it from this bottle. If there is a little teeny bit of liquid still in there it s not a big deal. Take that solution and put it into your big 10-ml clear bottle. This is the beginning of your mixture. Then you ll extract 4 more ml from your bacteriostatic water bottle. Pressurize the bacteriostatic water bottle by injecting 5ml of air into the bottle. 4. Fill your 5ml needle all the way up to the 4-ml mark. Put the 4 ml BAC water into your 10 ml mixing bottle that now contains your HCG mixture. You should now have a total of 5ml of HCG. FINISHED PRODUCT-5000IU s plus 5ml s bacteriostatic water = dosage of 200IUs of HCG daily. This should last you about 23 days which is the right amount of shots for the 26-day cycle. Duplicate this process on your 23- day to continue through the 43 day protocol. 62

You can also watch the video at www.hcgbodyforlife.com A radiant and happy life will open up just by having radiant and happy thoughts ~ Ryuho Okawa How Much HCG to Inject and How to Fill the Syringe Video Link http://www.youtube.com/watch?v=jovpkkpsobw I've had a lot of e-mails about how much HCG to actually put in the syringe and people aren t sure what size of syringes that they're getting. If you're getting the insulin needles (which are what I recommend, because it's not as long) or if you choose larger needles, I'd still be able to show you how much HCG to put into your syringe. Now go over to the fridge where you store your HCG and let's see if I can help you figure that out. 63

Keep the HCG refrigerated at all times so you can make sure it stays fresh. You should fill your syringe to the.20 mark and inject this amount daily. (This is approximately 200 IU s). This amount seems to work best for most dieters. With that said, you always want to keep this clean and sterile. If you're touching it a lot, make sure you put alcohol swab on there and use the needle coming out of the package. When injecting, put the needle into the bottle (in the center) and then usually what I do is to inject some here and there so I can get the HCG out. I usually overfill it (over 2) and then I push back into it at a downward angle to the.20 units mark. That gets the air bubbles out and you have your.20 units or 20 mark. You may also have needles that say 50 units instead of 100 units, but it s still going to be the same number, the 20. And that's 200 IU s. 64

Put that back on and you're ready to go. If you happen to have a larger needle for some reason and you'll see here that this one has 3ml but it's larger, you're still going be on the no. 2 nd hash line of the large syringe line on this syringe. For further clarification, simply copy and paste the video website link above in you internet browser to watch an easy to follow instructional video. 65