MLI HYBRID STATCOM WITH WIDE COMPENSATION RANGE AND LOW DC LINK VOLTAGE

Similar documents
Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Multilevel Inverter Based Statcom For Power System Load Balancing System

Ripple Reduction Using Seven-Level Shunt Active Power Filter for High-Power Drives

Hybrid Active Power Filters for Reactive Power Compensation with Adaptive DC-Link Voltage Control

MMC based D-STATCOM for Different Loading Conditions

Comparison of Reference Current Extraction Methods for Shunt Active Power Filters

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS

Intelligence Controller for STATCOM Using Cascaded Multilevel Inverter

A NOVEL APPROACH TO ENHANCE THE POWER QUALITY USING CMLI BASED CUSTOM POWER DEVICES

A Novel Cascaded Multilevel Inverter Using A Single DC Source

Cascaded Two-Level Inverter using Fuzzy logic Based multilevel STATCOM for High Power Applications

A THREE PHASE SHUNT ACTIVE POWER FILTER FOR HARMONICS REDUCTION

Size Selection Of Energy Storing Elements For A Cascade Multilevel Inverter STATCOM

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

DIGITAL SIMULATION OF MULTILEVEL INVERTER BASED STATCOM

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

A COMPARITIVE STUDY OF THREE LEVEL INVERTER USING VARIOUS TOPOLOGIES

SEVERAL static compensators (STATCOM s) based on

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

Multilevel Current Source Inverter Based on Inductor Cell Topology

TRANSFORMER LESS H6-BRIDGE CASCADED STATCOM WITH STAR CONFIGURATION FOR REAL AND REACTIVE POWER COMPENSATION

Mitigation of Current Harmonics with Combined p-q and Id-IqControl Strategies for Fuzzy Controller Based 3Phase 4Wire Shunt Active Filter

SINGLE PHASE THIRTY ONE LEVEL INVERTER USING EIGHT SWITCHES TOWARDS THD REDUCTION

SEVEN LEVEL HYBRID ACTIVE NEUTRAL POINT CLAMPED FLYING CAPACITOR INVERTER

A NEW TOPOLOGY OF CASCADED MULTILEVEL INVERTER WITH SINGLE DC SOURCE

A Comparative Study of Different Topologies of Multilevel Inverters

Power Quality Improvement Using Cascaded Multilevel Statcom with Dc Voltage Control

Grid Connected Photovoltaic Micro Inverter System using Repetitive Current Control and MPPT for Full and Half Bridge Converters

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

Cascaded Two Level Electrical Converter-Based Multilevel STATCOM for High Power Utilization

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS

ISSN Vol.04,Issue.16, October-2016, Pages:

Phase Shift Modulation of a Single Dc Source Cascaded H-Bridge Multilevel Inverter for Capacitor Voltage Regulation with Equal Power Distribution

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Bhanutej Jawabu Naveez Assistant Professor, Vignana Bharathi Institute of Technology, Aushapur, Ghatkesar, Hyderabad.

PUBLICATIONS OF PROBLEMS & APPLICATION IN ENGINEERING RESEARCH - PAPER CSEA2012 ISSN: ; e-issn:

Modelling and Simulation of High Step up Dc-Dc Converter for Micro Grid Application

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

A New Multilevel Inverter Topology with Reduced Number of Power Switches

Joe Warner, Electric Power Industry Conference (EPIC), November 15, 2016 Advances in Grid Equipment Transmission Shunt Compensation

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Enhancement of Power Quality using active power filter in a Medium-Voltage Distribution Network switching loads

Design of Multi-Level Inverter and Its Application As Statcom to Compensate Voltage Sags Due to Faults

Implementation of Single Stage Three Level Power Factor Correction AC-DC Converter with Phase Shift Modulation

CAPACITOR VOLTAGE BALANCING IN SINGLE PHASE SEVEN-LEVEL PWM INVERTER

A Review on Simulation and Implementation of Thyristor controlled reactor and Shunt Hybrid Power Filter

Multilevel Inverter with Coupled Inductors with Sine PWM Techniques

MODELING AND SIMULATION OF MICRO GRID SYSTEM BASED ON RENEWABLE POWER GENERATION UNITS BY USING FIVE LEVEL CASCADED H-BRIDGE CONVERTER

Series Parallel Switched Multilevel DC Link Inverter Fed Induction Motor

Multilevel Inverter for Single Phase System with Reduced Number of Switches

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

ANALYSIS OF SYNCHRONOUS-REFERENCE-FRAME-BASED CONTROL METHOD FOR UPQC UNDER UNBALANCED AND DISTORTED LOAD CONDITIONS Salava Nagaraju* 1

DESIGN OF A MODE DECOUPLING FOR VOLTAGE CONTROL OF WIND-DRIVEN IG SYSTEM

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

ISSN Vol.02,Issue.19, December-2013, Pages:

Implementation of Cascade Multilevel Inverter in Distribution Systems as Power Line Conditioner

CASCADED H-BRIDGE MULTILEVEL INVERTER FOR INDUCTION MOTOR DRIVES

Power Quality Improvement Using Cascaded Multilevel Statcom with Dc Voltage Control

ISSN Vol.03,Issue.07, August-2015, Pages:

Investigation of negative sequence injection capability in H-bridge Multilevel STATCOM

Key terms: Voltage, Phase Angle, FACTS, Multilevel Converter, Power Quality, STATCOM.

Svpwm Technique to Eliminate Harmonics and Power Factor Improvement Using Hybrid Power Filter and By Using Dsp Tms 320lf2407

Power Quality enhancement of a distribution line with DSTATCOM

Keywords Cascaded Multilevel Inverter, Insulated Gate Bipolar Transistor, Pulse Width Modulation, Total Harmonic Distortion.

Reactive Power Compensation of LC Coupling Hybrid Active Power Filters by DC Link Voltage Controls

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

Low Order Harmonic Reduction of Three Phase Multilevel Inverter

Analysis of IM Fed by Multi-Carrier SPWM and Low Switching Frequency Mixed CMLI

Modified Transistor Clamped H-bridge-based Cascaded Multilevel inverter with high reliability.

MODERN power electronics have contributed a great deal

IEEE Transactions On Circuits And Systems Ii: Express Briefs, 2007, v. 54 n. 12, p

Power Quality Improvement by Using Shunt Hybrid Power Filter and Thyristor Controlled Reactor with Fuzzy Logic Controller

Electromagnetic Compatibility and Better Harmonic Performance with Seven Level CHB Converter Based PV-Battery Hybrid System

HARMONIC contamination, due to the increment of nonlinear

Hybrid 5-level inverter fed induction motor drive

Improvement in Power Quality of Distribution System Using STATCOM

Performance of Indirectly Controlled STATCOM with IEEE 30-bus System

High Current Gain Multilevel Inverter Using Linear Transformer

A Modified Single-Phase Quasi z source converter

Three Phase Parallel Multilevel Inverter Fed Induction Motor Using POD Modulation Scheme

A Single-Phase Cascaded Multilevel Inverter Based on a New Basic Unit with Reduced Number of Power Switches

A New Control Scheme for Power Quality Improvement with STATCOM

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online):

A Time Domain Reference-Algorithm for Shunt Active Power Filters

An Efficient Cascade H-Bridge Multilevel Inverter for Power Applications

ANALYSIS OF PWM STRATEGIES FOR Z-SOURCE CASCADED MULTILEVEL INVERTER FOR PHOTOVOLTAIC APPLICATIONS

Reduction of Power Electronic Devices with a New Basic Unit for a Cascaded Multilevel Inverter fed Induction Motor

Improving Passive Filter Compensation Performance With Active Techniques

Analysis and Simulation of Multilevel DC-link Inverter Topology using Series-Parallel Switches

Study on Voltage Controller of Self-Excited Induction Generator Using Controlled Shunt Capacitor, SVC Magnetic Energy Recovery Switch

Harmonic Analysis Of Three Phase Diode Clamped Multilevel Inverters

B.Tech Academic Projects EEE (Simulation)

Grid connected Boost-Full-Bridge photovoltaic microinverter system using Phase Opposition Disposition technique and Maximum Power Point Tracking

MATLAB Implementation of a Various Topologies of Multilevel Inverter with Improved THD

APF technical features. APF technical principle. About. solution is adaptive for load increasing in power grid

Switching Angles and DC Link Voltages Optimization for. Multilevel Cascade Inverters

Transcription:

MLI HYBRID STATCOM WITH WIDE COMPENSATION RANGE AND LOW DC LINK VOLTAGE #1 BONDALA DURGA, PG SCHOLAR #2 G. ARUNA LAKSHMI, ASSISTANT PROFESSOR DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING KAKINADA INSTITUTE OF TECHNOLOGICAL SCIENCES, RAMACHANDRAPURAM,EGDT, AP ABSTRACT-A hybrid-statcom in three-phase power system is proposed discussed as a costeffective reactive power compensator for medium voltage level application is proposed in this paper. Because of these prominent characteristics, the system costs can be greatly reduced. By using fivelevel inverter is developed applied for injecting the real power of the renewable power into the grid to reduce the switching power loss, harmonic distortion, electromagnetic interference caused by the switching operation of power electronic devices. Its V-I characteristic is then analyzed, discussed, compared with traditional STATCOM capacitive coupled STATCOM (C-STATCOM). The system parameter design is then proposed on the basis of consideration of the reactive power compensation range avoidance of the potential resonance problem. After that, a control strategy for hybrid- STATCOM is proposed to allow operation under different voltage current conditions, such as unbalanced current, voltage dip, voltage fault. By using the simulation results we can verify the wide compensation range low DClink voltage characteristics the good dynamic performance of the proposed hybrid-statcom. Index Terms Capacitive-coupled static synchronous compensator (C-STATCOM), hybrid- STATCOM, low dc-link voltage, STATCOM, wide compensation range. I. INTRODUCTION A hybrid-statcom is proposed, with the distinctive characteristics of a much wider compensation range than C-STATCOM [10] other series-type PPF-STATCOMs a much lower DC-link voltage than traditional STATCOM [4]-[9] other parallel-connected hybrid STATCOMs. To improve the operating performances of the traditional STATCOMs, C-STATCOMs, other PPFSTATCOMs, many different control techniques have been proposed. THE large reactive current in transmission systems is one of the most common power problems that increases transmission losses lowers the stability of a power system [1]. Application of reactive power compensators is one of the solutions for this issue. Static VAR compensators (SVCs) are traditionally used to dynamically compensate reactive currents as the loads vary from time to time. However, SVCs suffer from many problems, such as resonance problems, harmonic current injection, slow response [2]-[3]. To overcome these disadvantages, static synchronous compensators (STATCOMs) active power filters (APFs) were developed for reactive current compensation with faster response, less harmonic current injection, better performance [4]-[9]. However, the STATCOMs or APFs usually require multilevel structures in a medium- or high-voltage level transmission system to reduce the high-voltage stress across each power switch DC-link capacitor, which drives up the initial operational costs of the system also increases the control complexity. A new control strategy for hybrid-statcom is proposed to coordinate the TCLC part the active inverter part for reactive power compensation under different voltage current conditions, such as unbalanced current, voltage fault, voltage dip. To reduce the current rating of the STATCOMs or APFs, a hybrid combination structure of PPF in parallel with STATCOM was proposed. However, this hybrid compensator is dedicated for inductive loading operation. When it is applied for capacitive loading compensation, it easily loses its small active inverter rating characteristics. PAPER AVAILABLE ON WWW.IJECEC.COM-VOLUME4-ISSUE2 27

To overcome the shortcomings of different reactive power compensators [1]-[10] for transmission systems, this paper proposes a hybrid STATCOM that consists of a thyristor-controlled LC part (TCLC) an active inverter part, as shown in Fig. 1. The TCLC part provides a wide reactive power compensation range a large voltage drop between the system voltage the inverter voltage so that the active inverter part can continue to operate at a low DC-link voltage level.the small rating of the active inverter part is used to improve the performances of the TCLC part by absorbing the harmonic currents generated by the TCLC part, avoiding mistuning of the firing angles, preventing the resonance problem. The active inverter part is composed of a voltage source inverter with a DC-link capacitor the small rating active inverter part is used to improve the performance of the TCLC part. In addition, the coupling components of the traditional STATCOM C-STATCOM are also presented in Fig. 1. The characteristics of different reactive power compensators the proposed hybridstatcom for the transmission system are compared summarized in Table I. TABLE I CHARACTERISTICS OFDIFFERENT COMPENSATORS FOR TRANSMISSION SYSTEM II. CIRCUIT CONFIGURATION OF THE HYBRID-STATCOM Fig. 1 shows the circuit configuration of hybrid- STATCOM, in which the subscript phase a, b, c in the following analysis. are the source load voltages sts for are the source, load, compensating currents, respectively. is the transmission line impedance. The hybrid-statcom consists of a TCLC an active inverter part. The TCLC part is composed of a coupling inductor a parallel capacitor a thyristor-controlled reactor with The TCLC part provides a wide continuous inductive capacitive reactive power compensation range that is controlled by controlling the firing angles thyristors. of the III. V-I CHARACTERISTICS OF THE TRADITIONAL STATCOM, C-STATCOM AND HYBRID-STATCOM The purpose of the hybrid-statcom is to provide the same amount of reactive power as the loadings consumed, but with the opposite polarity The hybrid-statcom compensating reactive power is the sum of the reactive power that is provided by the TCLC part the reactive power that is provided by the active inverter part. Therefore, the relationship among can be expressed as FIG.1.Circuit configuration of the hybrid STATCOM. PAPER AVAILABLE ON WWW.IJECEC.COM-VOLUME4-ISSUE2 28

The reactive powers can also be expressed in terms of voltages currents as where is the coupling impedance of the TCLC part; is the corresponding firing angle; are the root mean square (RMS) values of the coupling point the inverter voltages; are the RMS value of the load compensating reactive currents, where simplified as Therefore, (2) can be further where the TCLC part impedance expressed as can be A. TCLC part control Different with the traditional IV. CONTROL STRATEGY OF HYBRIDSTATCOM A control strategy for hybrid-statcom is proposed by coordinating the control of the TCLC part the active inverter part so that the two parts can complement each other s disadvantages the overall performance of hybrid-statcom can be improved. The control strategy of hybrid-statcom is separated into two parts for discussion: A. TCLC part control B. Active inverter part control. The response time of hybrid-statcom is discussed in part C. The control block diagram of hybrid STATCOM is shown in Fig. 5. SVC control based on the traditional definition of reactive power [2]-[3], to improve its response time, the TCLC part control is based on the instantaneous pq theory [4]. The TCLC part is mainly used to compensate the reactive current with the controllable TCLC part impedance Referring to (3), to obtain the minimum inverter voltage can be calculated with Ohm s law in terms of the RMS values of the load voltage the load reactive current However, to calculate the in real time, the expression of terms of instantaneous values as can be rewritten in where v is the norm of the three-phase instantaneous load voltage phase reactive power. is the DC component of the B. Active inverter part control In the proposed control strategy, the instantaneous active reactive current id-iq method [7] is PAPER AVAILABLE ON WWW.IJECEC.COM-VOLUME4-ISSUE2 29

implemented. The calculated contains reactive power, unbalanced power, current harmonic components. By controlling the compensating current icx to track its reference the active inverter part can compensate for the load harmonic currents improve the reactive power compensation ability dynamic performance of the TCLC part under different voltage conditions. The icx* can be calculated as Cascaded H-Bridge Multilevel Inverter: The cascaded H-bride multi level inverter is to use capacitors switches requires less number of components in each level. This topology consists of series of power conversion cells power can be easily scaled. The combination of capacitors switches pair is called an H-bridge gives the separate input DC voltage for each Hbridge. It consists of H-bridge cells each cell can provide the three different voltages like zero, positive DC negative DC voltages H-bridge multi level inverter, 9- H-bridge clamped multi level inverter. where are the instantaneous active reactive current. C. Response time of hybrid-statcom The TCLC part has two back-to-back connected thyristors in each phase that are triggered alternately in every half cycle, so that the control period of the TCLC part is one cycle (0.02 s). FIG.2.H-bridge multi level inverter Multilevel Inverter Now a days many industrial applications have begun to require high power. Some appliances in the industries however require medium or low power for their operation. Using a high power source for all industrial loads may prove beneficial to some motors requiring high power, while it may damage the other loads. Some medium voltage motor drives utility applications require medium voltage. Types of Multilevel Inverter: Multilevel inverters are three types. Diode clamped multilevel inverter Flying capacitors multilevel inverter FIG.3.Waveform of 5 level inverter V. SIMULATION RESULTS In this section, the simulation results among traditional STATCOM, C-STATCOM, the proposed hybrid-statcom are discussed compared. The detailed simulation results are summarized in Table II. Cascaded H- bridge multilevel inverter PAPER AVAILABLE ON WWW.IJECEC.COM-VOLUME4-ISSUE2 30

TABLE II SIMULATION RESULTS FOR INDUCTIVE AND CAPACITIVE REACTIVE POWER COMPENSATION OF TRADITIONAL STATCOM, C-STATCOM AND HYBRIDSTATCOM Dynamic reactive power compensation of phase a by applying hybrid-statcom A.Inductive light loading When the loading is inductive light, traditional STATCOM requires a high DC-link voltage compensation. B. Inductive heavy loading for To compensate for the inductive heavy loading, traditional STATCOM still requires a high DC-link voltage of for compensation. Traditional STATCOM can obtain acceptable results Dynamic compensation waveforms of by applying hybrid-statcom under unbalanced loads. Control block diagram of simulation Dynamic compensation waveforms of by applying hybrid STATCOM during voltage dip. PAPER AVAILABLE ON WWW.IJECEC.COM-VOLUME4-ISSUE2 31

VI. CONCLUSION In this paper, a hybrid-statcom in three-phase power system is proposed discussed as a costeffective reactive power compensator for medium voltage level application. The system configuration V-I characteristic of the hybrid-statcom are analyzed, discussed, compared with traditional STATCOM C-STATCOM. In addition, its parameter design method is proposed on the basis of consideration of the reactive power compensation range prevention of a potential resonance problem. Moreover, the control strategy of the hybrid-statcom is developed under different voltage current conditions. Finally, the wide compensation range low DC-link voltage characteristics with good dynamic performance of the hybrid-statcom are proved by both simulation experimental results REFERENCES: [1] J. Dixon, L. Moran, J. Rodriguez, R. Domke, Reactive power compensation technologies: Stateof-the-art review, Proc. IEEE, vol. 93, no. 12, pp. 2144 2164, Dec. 2005. [2] L. Gyugyi, R. A. Otto, T. H. Putman, Principles applications of static thyristorcontrolled shunt compensators, IEEE Trans. Power App. Syst., vol. PAS-97, no. 5, pp. 1935 1945, Sep./Oct. 1978. [3] T. J. Dionise, Assessing the performance of a static var compensator for an electric arc furnace, IEEE Trans. Ind. Appl., vol. 50, no. 3, pp. 1619 1629, Jun. 2014.a multilevel STATCOMs, IEEE Trans. Ind. Electron., vol. 61, no. 6, pp. 2743 2753, Jun. 2014. [7] V. Soares P. Verdelho, An instantaneous active reactive current component method for active filters, IEEE Trans. Power Electron., vol. 15, no. 4, pp. 660 669, Jul. 2000. AUTHOR'S DETAILS: BONDALA DURGA, Pursuing M-Tech (power system) in EEE from KITS college Ramachrapuram G. ARUNA LAKSHMI, Now She Working As Assistant Professor In Kits College, Department Of eee, Ramachrapuram. [4] F. Z. Peng J. S. Lai, Generalized instantaneous reactive power theory for three-phase power systems, IEEE Trans. Instrum. Meas., vol. 45, no. 1, pp. 293 297, Feb. 1996. [5] L. K. Haw, M. S. Dahidah, H. A. F. Almurib, A new reactive current reference algorithm for the STATCOM system based on cascaded multilevel inverters, IEEE Trans. Power Electron., vol. 30, no. 7, pp. 3577 3588, Jul. 2015. [6] J. A. Munoz, J. R. Espinoza, C. R. Baier, L. A. Moran, J. I. Guzman, V. M. Cardenas, Decoupled modular harmonic compensation for PAPER AVAILABLE ON WWW.IJECEC.COM-VOLUME4-ISSUE2 32