Technical Data Sheets

Similar documents
Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

TECHNICAL DATA SHEET B9600FXS kva


Gutor PxW AC UPS Designed for North American Market

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

TOSHIBA International Corp

PRODUCTS FOR ELECTRICAL SUB-STATIONS UPS, DC-AC INVERTERS, BATTERY CHARGERS, DC-DC CONVERTERS, 1-PHASE TO 3-PHASE CONVERTERS

R&D TECHNICAL SPECIFI

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

Dale Power Solutions Ltd

Technical Specifications

These true online inverters integrate pulse width modulation (PWM) control combined with high frequency IGBT power transistors.

SG-CE Series PurePulse

Chloride FP-60Z 5 to 60kVA

PROTECT 8 INDUSTRIAL UPS. Protect 8.31 Single Phase output 10 kva 80 kva. Protect 8.33 Three Phase output 10 kva 120 kva. Engineering is our business

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

Est Static Frequency Converter. SFX 10kVA - 10MVA

MITSUBISHI ELECTRIC 2033A DDC SERIES SPECIFICATIONS

GESS Industrial UPS System. Overview

G-NET. 1 kva-10 kva. Rack & Tower UPS

B9000 FXS kVA B9600 FXS kVA

SENTINEL XR PLUS 5-10kVA

Table K. Input/Output Ratings & External Wiring Requirements for the Powerware /80 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220

OPUS C DC Power Systems OC2066 and OC1666 floor standing Cabinets

SECTION THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM

Liebert Hipulse-U. Fully Digital Dual DSP Controlled Transformer Based UPS

MAJORSINE Power Inverter

Est Static Frequency Converter. SFX 10kVA - 10MVA

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

1KVA-2KVA-3KVA 6KVA-10KVA. NUPS22 Series

Series PCI + PIT PIT5738 U IN PIT5748 U IN PCI5748 PCI5738. Series PIT 19 - Cabinet G10

Chloride 80-NET Secure Power For Mission Critical Applications 60kVA to 120kVA. AC Power For Business-Critical Continuity

GUIDE SPECIFICATIONS 40-80kVA, kVA and kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL

SPECIFICATION. Online UPS 3000VA

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

DIGITAL SWITCH MODE POWER SUPPLIES MAIN APPLICATIONS GENERAL INTRODUCTION TO QP23 SERIES

STATIC UNINTERRUPTIBLE POWER SYSTEM Revised 4/30/ Electrical Systems

StatiVolt. Inverter UPS Systems. Features. Contents

S11 Adjustable Speed Drive Engineering Specification

TEST REPORT IEC Uninterruptible power systems Part 3: Method of specifying the performance and test requirements

RELIABLE SOLUTIONS in POWER ELECTRONICS VRST SERIES. Power Management Instruments ELECTRONIC STABILIZER FROM PMI & OES GROUP COMPANIES SUD

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

BAT-Series Grid Inverter. Battery Charger.

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05

Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Liebert THE NEW LEADER IN THREE-PHASE UPS PRODUCT. Npower. 30 to 130 kva. True Double Conversion. Exceptional Reliability. Unmatched Performance

AXA 2400 COMPACT & 90 kva solid-state GPU

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES

CROSS Chassis from 160 A to 450 A

Orbital GFI Inverter Series

EL-AC Electronic Load

SM2000 TECHNICAL DESCRIPTION

Chloride. FP-50z 5 160kVA Industrial AC UPS

Technical Data Sheet AMIK 300 / 301

Side view View from below Rear view

Product Catalog PRODUCT CATALOG. Power supply system & test equipment

Table G. INPUT/OUTPUT Ratings & External Wiring Requirements for the /160 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220

UNINTERRUPTIBLE POWER SUPPLY SPECIFICATIONS MODEL 1100B SERIES

SHORE TO SHIP FREQUENCY

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics

ALL PRODUCT BROCHURE

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

FCL VOLTAGE & FREQUENCY CONVERTERS. FCL H SERIES - SINGLE PHASE - 2 to 30 kva H SERIES MODELS. AC SINGLE PHASE 2 TO 30 kva STATIC VARIABLE AC

CP-T range Product group picture

Types VIS and CRE. A e. Compliance with Standards. Uses. Features

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

COMPANY. GCRDC Lifter Gear Converter 12Vcc, 24Vcc, 48Vcc, 400VA GRDC Linear Converter DC/DC 13.8Vcc, 40AVcc 560W

VF-nC1 Adjustable Speed Drive Engineering Specification

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Power IT LV Active Filters PQFA - PQFL - PQFT

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Built To Order 3 Phase UPS Systems

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

The world is changing but our power is constant...

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

CP-T range Benefits and advantages

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Please note and refer to warning marks which you will find in the unit.

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

OPTI-UPS User s Guide

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

AMIK 200 / 201 Technical Data Sheet

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

Power supply CP-T 24/20.0 Primary switch mode power supply

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Uninterruptible Power System (UPS) 20 to 320 kva

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Transcription:

GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SG Series 80 100 120 kva 400 Vac CE Series 0 Date of issue: 01.11.2007 SGSE_080_UPS_GE_01a SGSE_100-120_UPS_GE_01a SG Series 80 kva SG Series 100-120 kva GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 51 44 www.gedigitalenergy.com GE imagination at work

GENERAL DATA Topology VFI, double conversion with integrated transformer Nominal output power at PF=0.6...0.9 lag. kva 80 100 120 Overall efficiency at 100% load in VFI mode 91.4 91.3 91.1 Overall efficiency at 75% load in VFI mode % 92.3 92.1 91.9 Overall efficiency at 50% load in VFI mode 92.9 92.7 92.5 Overall efficiency at 100% load in SEM mode % 98.0 98.5 98.0 Heat dissipation at 100% load in VFI mode, PF=0.8 lag. and charged battery kw 6.02 7.62 9.38 Cooling air (25 C 30 C) m 3 /h 1760 2225 2740 Audible noise level db(a) 65 65 65 Battery type Valve regulated lead-acid (VRLA), vented lead-acid, NiCd Operating temperature range UPS: 0 C 40 C Storage temperature range -25 C +55 C Relative Humidity Max. 95% (non-condensing) Max. altitude without power derating Power derating (according to IEC 62040-3) 1000m 1500m: -5% / 2000m: -9% / 2500m: -14% / 3000m: -18% Protection degree IP 20 (IEC 60529) s EN 50091 / IEC 62040, CE marking EMC EN 50091-2 / IEC 62040-2 (Class A as option) Electrostatic discharge immunity 4kV contact / 8kV air discharge Internal protection All live parts shrouded Transport Cabinet suitable for handling by forklift Colour RAL 9003 (white) Installation Can be positioned against a wall and floor fixed Service access Front access only External cable connections Bottom or top, at right side of the cabinet Cooling Redundant fans Paralleling (RPA version) Up to 8 units parallelable for redundancy or capacity in RPA configuration (optional) RECTIFIER Rectifier bridge input voltage Other input voltages Input frequency Three phase, 6 thyristors, overtemperature protection Nominal: 3 x 380V / 400V / 415V + N Rectifier accepted ph-ph voltage range: 320V 460V (320V only for 405 VDC battery floating) On request 50/60 Hz +/-10% (45-66 Hz) 5 th harmonic filter 5 th + 11 th harmonic filter Power factor (with filter) 0.92 0.96 Input current THD at nominal load (with filter) 8% 6% Inrush current Limited by soft-start circuit Power walk-in >30 seconds Output voltage tolerance +/- 1% DC voltage ripple <1% DC current ripple Max. 5% the battery capacity [Ah], expressed in A Battery charging characteristic IU (DIN 41773), T compensated floating voltage Battery charging current limit Programmable Input power data kva 80 100 120 Input power at inverter nominal load and charged battery at PF=0.8 lag. 70.0 87.6 105.4 kw at PF=0.9 lag. 78.8 98.6 118.6 Max. input power at inverter nominal load and max. battery recharge current (programmable) kw 87.5 109.5 133.3 Max. battery charging current (programmable) at at PF=0.8 lag. 44 55 65 A the beginning of battery recharge at nominal load at PF=0.9 lag. 22 27 32 Modifications reserved Page 2/5

BATTERY Battery type Valve regulated lead-acid (VRLA)-standard, Vented lead-acid, wet battery and NiCd Number of 12V blocks, 6 cells/block 30 to 32, placed in external cabinets (33 blocks on request) Float voltage at 20 C 405V 436V (dependent on the number of blocks) Min. discharge voltage (programmable) 1.65V / cell (1.60V / cell for 33 blocks) Recharge time <5 hours up to 90% of battery capacity Battery to earth fault detection Automatic and manual battery test Automatic battery contactor Battery power data kva 80 100 120 DC power at full load and PF=0.8 lag. kw 68.8 86.0 103.2 DC power at full load and PF=0.9 lag. kw 77.4 96.8 116.1 DC power at full typical computer load (PF=0.66 lag.) kw 56.2 70.2 84.3 Matching battery cabinets See optional features on page 4 INVERTER Nominal output power at PF=0.6... 0.9 lag. 80-100 - 120 kva Nominal output voltage (on site programmable) 3 x 380V / 400V / 415V + N Inverter bridge SVM (Space Vector Modulation) and IGBT technology Output transformer (for galvanic separation) Output waveform Sine wave Output voltage tolerance: - static... +/- 1% - dynamic (at load step 0 100 0%)... +/- 2% - dynamic (at load step 0 50 0%)... +/- 1.5% - recovery time to +/-1%... 20 ms - output voltage THD for 100% linear load... Max. 1% - output voltage THD for 100% non-linear load (EN 50091) Max. 3% Output voltage tolerance at 100% unbalanced load (Ph-N) +/- 3% Output frequency 50/60 Hz (selectable) Output frequency tolerance: - free-running... +/- 0.1% - with mains synchronisation adjustable to... +/- 4% Phase displacement: - at 100% balanced load... 120 : +/- 1% - at 100% unbalanced load... 120 : +/- 2% Overload capability (at PF=0.8) 125% - 10 minutes, 150% - 1 minute Short-circuit characteristic Electronic short-circuit protection, current limit to 2.2 times In for 200 ms MTCB clearance capability (selectivity) 20% In within 5-10 ms (with MTCB class C) Crest factor >3:1 BYPASS Input connection Primary components Voltage limits for inverter/bypass load transfers Overload on bypass Separate (dual input-recommended) or common to the rectifier input - Static switch (SCR) on bypass - Electromechanic contactors (backfeed protection) on bypass and inverter - 2 manual switches for maintenance bypass +/- 10% (adjustable) 200% for 5 minutes & 45 times In for 10 ms, non repetitive INTERFACING 6 programmable signalling voltage-free contacts - information for easy integration and signalling (available on Delta and block terminals) - 27 user settable signals Serial channel RS232 (on Delta 9 pin connector) - EMERGENCY POWER OFF (n/c contact, customer supplied) Input signals - GEN ON (emergency power supply ON, n/o contact, customer supplied) - 2 auxiliary signals, with settable functionality Note: all indicated values are typical. Variations may be found from one unit to another. Modifications reserved Page 3/5

FRONT PANEL CONTROLS, SIGNALS AND ALARMS SYNOPTIC DIAGRAM OF THE UPS: Represents the operational status with integrated LEDs and power flow indicators. SERVICE CHECK (LED): Turns on when maintenance is due or when the UPS is Service mode. ALARM: Visual (LED) and audible signal (buzzer), active when an alarm condition is present. STOP OPERATION: Visual (LED) and audible signal (buzzer) active approx. 3 minutes before complete and automatic load dis-connection (due to an overtemperature condition or fully discharged battery). LOAD LEVEL, BATTERY AUTONOMY: Status indicator bar graphs. MONITORING SYSTEM with multi language LCD display and control keys. PUSH-BUTTONS: - INVERTER ON - INVERTER OFF - MUTE - LAMP TEST - TOTAL OFF (key with protective cover): to be pressed for emergency off. OPTIONS BUILT-IN UPS OPTIONS: 1. RPA kit 2. Auxiliary Power Supply (APS) 24VDC 3. Harmonic filters 4. EMC filters IEC 62040-2 Class A COMMUNICATION: 1. RSB - Remote Signalling Box (cable for connection to UPS not included) 2. Advanced SNMP Card 3. JUMP software suite 4. IRIS service 5. Modbus RTU Interface OPTIONS IN ADDITIONAL CABINETS: Dimensions (WxDxH): 800x300x 500x800x1820mm 800x800x1820mm 1200x800x1820mm 1. Rectifier and/or bypass transformer 2. Active Filter 3. 12 pulse rectifier with or without galvanic separation 4. Special voltages: input and/or output On request 5. Centralized maintenance bypass for RPA configuration On request 6. Empty battery cabinets External accessories: 1. External battery fuses box On request Modifications reserved Page 4/5

TECHNICAL DATA WEIGHTS (kg) SG Series 80 kva UPS cabinet Additional cabinet (500x800x1820) SG Series 100 & 120 kva 1'820mm UPS rating UPS standard EMC filter 5 th harmonic filter 5 th + 11 th harmonic filter Rectifier and/or bypass transformer 12 pulse without galvanic separation 12 pulse with galvanic separation 80 kva (6 pulse) 620 30 80 95 380 - - 1'820mm 1'850mm 80 kva (12 pulse) 570 30 - - 380 385 440 100 kva (6 pulse) 810 40 90 110 450 - - SGSE_080_UPS dimension_ge_01 100 kva (12 pulse) 750 40 - - 450 460 555 120 kva (6 pulse) 810 40 90 110 450 - - 120 kva (12 pulse) 750 40 - - 450 460 555 SGSE_100-120_UPS dimension_ge_01 1'200mm Note: Single weights have to be added up for system configuration to get the total weight! UPS BLOCK DIAGRAM, PROTECTIONS AND CABLE SECTIONS Common input Rectifier & Bypass K6 SGSE_Block diagram common input_01 SSM Q2 B L1/L2/L3/N F2 Separated input (recommended) Rectifier & Bypass K6 SGSE_Block diagram separate input_01 1 6 K4 K4 1 6 5 5 F3 Q1 Q1 E D K7 F1 K7 C K3 2 3 4 K3 2 3 4 A K 7 K F4 F4 7 1 = Rectifier 3 = Electronic Bypass 5 = Mains 7 = External Battery 2 = Inverter 4 = Manual Bypass 6 = Load F4 = External Battery Fuses Protections for mains voltages 3x380/220V, 3x400/230V, 3x415/240V SSM Protections and cable sections Cable sections A, B, C, D, E and K Recommended by European s Alternatively, local standards to be respected Fuses AgL or equivalent MTCB Cable sections (mm 2 ) kva F1 F2 F3 F4 A B C and E D K 80 3 x 160A 3 x 125A 3 x 160A 2 x 250A 3 x 50 + 25 4 x 35 4 x 50 + 25 4 x 35 + 25 2 x 120 + 70 100 3 x 200A 3 x 160A 3 x 200A 2 x 315A 3 x 70 + 35 4 x 50 4 x 70 + 35 4 x 50 + 25 2 x 150 + 95 120 3 x 250A 3 x 200A 3 x 250A 2 x 355A 3 x 120 + 70 4 x 70 4 x 120 + 70 4 x 70 + 35 2 x 185 + 95 SEV / ASE cable sections recommended in Switzerland (mm 2 ) kva A B C and E D K 80 3 x 70 + 35 4 x 50 4 x 70 + 35 4 x 50 + 25 2 x 150 + 95 F1, F2, F3, F4, A, B, C, D, E, K: supplied by customer 100 3 x 95 + 50 4 x 70 4 x 95 + 50 4 x 70 + 35 2 x 185 + 95 F4: can be supplied by GE. 120 3 x 150 + 95 4 x 95 4 x 150 + 95 4 x 95 + 50 2 x 240 + 120 IMPORTANT NOTE! The UPS is designed for TN System. The input neutral shall be grounded at source and shall never be disconnected. 4 pole breaker shall not be used at the UPS input (see also IEC 60634, IEC 61140, IEC 61557). Q2 Modifications reserved Page 5/5