READ ME FIRST QUICK INSTALL GUIDE Wireless Controller Kit XWS-1310 Package Contents: XWC-1000 Wireless Controller Rack Mount Kit Power Cord XAP-310 Access Points XFS-1054P PoE Switch
BEFORE YOU BEGIN INSTALLATION Access Point Firmware: If you are using APs other than those included in this kit, ensure that the firmware is v5 or newer. Visit the AP Firmware upgrade page at luxul.com/ap-upgrade for details. Controller Setup Sequence: Be sure to setup the XWC-1000 Wireless Controller BEFORE powering up the APs. Once logged into the Wireless Controller, the Setup Wizard will prompt you when it is time to add the APs to the network. A DHCP server is required on the network. Accessibility: Once an Access Point is controlled by the XWC-1000 Wireless Controller, the web interface on the AP is no longer enabled. Conversely, if an AP configuration is managed via its web interface, communication with the XAP-1000 Wireless Controller will be disabled. To change an AP from Controller-managed to standalone (or the reverse), restore the AP to Factory Default. Firmware Updates: The XWC-1000 Wireless Controller automatically checks for firmware updates of Controller-compatible APs and the Wireless Controller itself, but requires Internet access to do so. The Wireless Controller will still operate without Internet access, but firmware updates will not be available. 1 Physical Installation Connecting Devices: The XWC-1000 Wireless Controller simply connects to the network. The XAP-310 APs connect to the network via the included PoE Ethernet switch (or other 802.3af/at switch).
PoE LINK/ACT POWER LAN AP AP PoE Switch AP LAN Wireless Controller Access Point Placement: Place APs to ensure adequate coverage, but not so far apart that there is no signal overlap. You may have to experiment with AP placement to optimize the roaming experience. The APs should overlap enough that the client device has a good connection to the AP to which it is currently attached, but also sees the next-nearest AP. Ideally, roaming clients should see signal strength of two overlapping APs in the range of -60 to -70 dbm at the midway point between two APs n n Note: Visit luxul.com/ap-placement for more detail on how to select and optimize AP placement.
nnnote: Consider using Ekahau HeatMapper to assist with this process, available from www.ekahau.com. Luxul also offers an informative How-To video on HeatMapper at luxul. com/how-to-videos. WIRELESS CONTROLLER SYSTEM KIT SETUP 1. Use an Ethernet cable to plug the XWC-1000 Wireless Controller into the network. Do not connect any APs to the network yet. nnnote: Be sure a DHCP server is present on the network and that all Luxul APs and the XWC-1000 Wireless Controller will share the same subnet. If your network uses a 192.168.0.X IP address scheme, you are ready to start the setup process. If not, you will need to manually change the IP address of your computer to be able to configure the XWC-1000 Wireless Controller so that it is on the same subnet as your network. For help setting the IP address of your particular operating system, visit luxul.com/ip-addressing. 2. To access the Setup Wizard, open your web browser and enter the Wireless Controller s default 192.168.0.19 IP address in the address field. Log in to the Wireless Controller using the default user name and password: Default IP: 192.168.0.19 Username: admin Password: admin
nnnote: If there is another device on the network already using the 192.168.0.19 address, you ll need to either temporarily disconnect or reconfigure that other device, or manually configure the Wireless Controller with a different address on a separate isolated network. 3. Follow the built-in Setup Wizard in the Wireless Controller. The Wizard will direct you to power the APs on at the appropriate time and walk you through completing the setup. ttsmart Tip: For more information on setup and configuration best practices, visit luxul.com/smart-tips. LEGAL AND REGULATORY INFORMATION No part of this publication may be modified or adapted in any way, for any purposes without permission in writing from Luxul. The material in this manual is subject to change without notice. Luxul reserves the right to make changes to any product to improve reliability, function, or design. No license is granted, either expressly or by implication or otherwise under any Luxul intellectual property rights. An implied license only exists for equipment, circuits and subsystems contained in this or any Luxul product. FCC ID: W59XAP310 IC: 8584A-XAP310 Regulatory Compliance The device complies with internationally recognized standards covering human exposure to electromagnetic fields from radio devices. This equipment also complies with FCC radiation exposure set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 20 cm (8 inches) during normal operation. Unauthorized antennas, modifications, or attachments could cause damage and may violate regulatory approvals. Any changes or modifications not expressly approved by the party responsible for compliance could void the authority to operate the equipment. The equipment version marketed in the U.S. is restricted to usage of channels 1-11 only.
Health and Safety Recommendations Warnings for the use of Wireless Devices: Please observe all warning notices with regard to the usage of wireless devices Potentially Hazardous Atmospheres: You are reminded of the need to observe restrictions on the use of radio devices in fuel depots, chemical plants etc. and areas where the air contains chemicals or particles (such as grain, dust, or metal powders). Safety in Hospitals: Wireless devices transmit radio frequency energy and may affect medical electrical equipment. When installed adjacent to other equipment, it is advised to verify that the adjacent equipment is not adversely affected. RF Exposure Guidelines Safety Information: The device complies with internationally recognized standards covering human exposure to electromagnetic fields from radio devices. Warning, Exposure to Radio Frequency (RF) Radiation: The radiated output of this device is below the FCC radio frequency exposure limits. Nevertheless, the device should be used in such a manner that the potential for human contact during normal operation is minimized. The end user must avoid any extended human RF exposure directly in front of the device, up to a distance of 20cm, when unit is on. When servicing the equipment and selecting a location for the antennas, it is important to note that a minimum distance of 20cm is required between personnel and the device or antenna to comply with the radio frequency exposure limit. The antenna used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. The following safety precautions should be observed: Do not touch or move the antenna while the unit is transmitting or receiving. Do not hold any component containing the radio such that the antenna is very close or touching any exposed parts of the body, especially the face or eyes, while transmitting. X X Do not operate the radio or attempt to transmit data unless the antenna is connected; this behavior may cause damage to the radio.
FCC Statement Wireless FCC 2.4GHz 802.11bgn This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Hereby, Luxul, 14203 Minuteman Drive, Suite 201, Draper, Utah, 84020, declares that this Luxul XAP-310 is in compliance with the essential requirements and other relevant provisions of Directive 1995/5/EC. For a copy of this report send a self addressed stamped envelope to: Luxul CE, 14203 Minuteman Drive, Suite 201, Draper, Utah, 84020.
Industry Canada (RSS-Gen Issue 4) This device complies with Industry Canada s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence. L exploitation est autorisée aux deux conditions suivantes : (1) l appareil ne doit pas produire de brouillage; (2) l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d en compromettre le fonctionnement. The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS-102 RF exposure, users can obtain Canadian information on RF exposure and compliance. Le dispositif rencontre l exemption des limites courantes d évaluation dans la section 2.5 de RSS 102 et la conformité à l exposition de RSS-102 rf, utilisateurs peut obtenir l information canadienne sur l exposition et la conformité de rf. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. Cet émetteur ne doit pas être Co-placé ou ne fonctionnant en même temps qu aucune autre antenne ou émetteur. Cet équipement devrait être installé et actionné avec une distance minimum de 20 centimètres entre le radiateur et votre corps. CAN ICES-3(B)/NMB-3(B) Sales P: 801-822-5450 E: sales@luxul.com Technical Support P: 801-822-5450 Option 3 E: support@luxul.com Copyright and Trademark Notices No part of this document may be modified or adapted in any way, for any purposes without permission in writing from Luxul. The material in this document is subject to change without notice. Luxul reserves the right to make changes to any product to improve reliability, function, or design. No license is granted, either expressly or by implication or otherwise under any Luxul intellectual property rights. An implied license only exists for equipment, circuits and subsystems contained in this or any Luxul product. Copyright 2015 Luxul. All rights reserved. The name Luxul, the Luxul logo, the Luxul logo mark and Simply Connected are all trademarks and or registered trademarks of Luxul Wireless, Inc. All other trademarks and registered trademarks are property of their respective holders. LUX-QIG-XWS-1310 12181509