GP-3124-L2x(D) 1.25Gbps SFP Optical Transceiver, 20km Reach

Similar documents
GLC LH SM. 1.25Gbps SFP Optical Transceiver, 20km Reach

XSS311-20LY. 1.25Gbps SFP Optical Transceiver, 20km Reach. Features. Applications. Description

AOP-324-R20(D) 1.25Gbps SFP Optical Transceiver, 20km Reach

GP-5524-L8x(D) 1.25Gbps SFP Optical Transceiver, 80km Reach

GP-8524-S5x(D) 1.25Gbps SFP Optical Transceiver, 550m Reach

1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1310nm TX / 1550 nm RX CFORTH-SFP-35-20S

SFP-7020-WB 1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1550nm TX / 1310 nm RX

HT201-24D083M Gbps 850nm SFP Optical Transceiver, 550m Reach

3CP-485L1MN-SX 1.25Gbps SFP Optical Transceiver, 550m Reach

AC05-A13L6-02 (-DD) 155Mbps SFP Optical Transceiver, 2km Reach

CWDM SFP 1.25G 40KM LC Duplex

1.25Gbps SFP Optical Transceiver, 550m Reach

GPB-5324L-L8CD 1.25Gbps SFP Bi-Directional Transceiver, 80km Reach 1550nm TX / 1310 nm RX

GP C(D) 155Mbps SFP Optical Transceiver, 2km Reach

SFP BIDI 2.488Gbps 20KM 1550nm TX/1310nm RX

1.25Gbps SFP Optical Transceiver, 550m Reach

1.25Gbps CWDM SFP Optical Transceiver, 80km Reach SFP-7080-Cxx

155Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

622Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

GPB-4324x-L4x(D) 1.25Gbps SFP Bi-Directional Transceiver, 40km Reach 1490nm TX / 1310 nm RX

SFP-ZX-SM Gbps SFP Optical Transceiver, 80km Reach

FSPC-xx12-40D. 1.25G SFP CWDM 1470nm~1610nm 40km Optical Transceiver

GPB-5303x-L2x(D) 155Mbps SFP Bi-Directional Transceiver, 20km Reach 1550nm TX / 1310 nm RX

622Mbps SFP Optical Transceiver, 40km Reach FS-622M-A40

1.25Gbps CWDM SFP Optical Transceiver, 40km Reach EPC-xx24-04C(D)

1.25Gbps SFP Optical Transceiver, 20km Reach GP L2x(D)

SFP M~2.67Gbps SFP Optical Transceiver, 300m Reach

1.25Gbps SFP Optical Transceiver, 550m Reach EP-8524-S5x(D)

1G SFP CWDM nm 80km Optical Transceivers

GLC-SX-MMD (1000BASE-SX SFP) Datasheet

XSB531-20xx Gbps SFP Bi-Directional Transceiver, 20 km Reach, 1550 nm TX/1310 nm RX. Features. Applications. Description

GPBC-xxxx24L-04CD 1.25Gbps SFP CWDM Bi-Di Single Fiber Transceiver, 40km Reach

2.67Gbps CWDM SFP Optical Transceiver, 40km Reach GPC-xx48-04X(D)

SNS SFP-GDCWXD-XX* 1.25 Gbps 80 km CWDM SFP Transceiver

SFP Optical Transceivers

SFP BIDI 2.5Gbps 40Km Tx1310/Rx1550nm / Tx1550/Rx1310nm

GPH-3102-L1C(D) 100BASE-LX Spring-Latch SFP Transceiver, 10km Reach

MGS-MM MODULO GBIC SFP 500M 4.25GBPS LC MM 850NM VCSEL PIN TRANSCEIVERS

EPON OLT 1.25Gbps 1000Base-PX20 Tx1490/Rx1310nm DDMI SLEP-1143-P

SGMII SFP 125Mbps 1310nm MMF 2KM SLSG D

SFP-1.25G-LX 1.25Gbps SFP Optical Transceiver, 10KM Reach

Product Specification Sheet

GDETP-XX21S-2CD DWDM EPON OLT SFP Transceiver

GNTP-4321S-C2CDA GPON SFP OLT Transceiver

GPON ONU SFF 2X10 GNUF-3412S-B2CDA

GPON SFP OLT Transceiver GNTP-4321S-B2CDA

6Gbps SFP+ Optical Transceiver,10 Km (OP3B10D ) Hot Pluggable, Duplex LC, +3.3V 1310nm DFB-LD. Features

Product Specification Sheet

LinkPower LPS LC MM 2630C/2630I. RoHS Compliant 1.25Gbps 850nm 550M Optical Transceiver

ES3112-3LCD Gbps SFP Optical Transceiver, 10KM Reach

LinkPower LPS SM BIDI 2612TC/2612TI & 2613RC/2613RI SC. RoHS Compliant 1.25G 1310/1550nm & 1550/1310nm 20km Transceivers

RoHS compliant TX-1310/RX-1550 nm Single-mode Bi-directional SFP LC Simplex Connector DDM. Features

EPON-OLT-20. OLT for IEEE 802.3ah-2004 PX Gbps Downstream and 1.25Gbps Upstream

1.25Gbps SFP Optical Transceiver, 80KM Reach

155Mbps 850nm Multimode Optical Transceiver Small Form Pluggable (SFP)

SO-CSFP-100Base-BX20D-34-O2 -I

Multimode 1.25Gbps 850nm Optical Transceiver SFP with MSA

GLC-GE-100FX-LEG. 155Mbps SFP Transceiver

Singlemode 155Mbps Optical Transceiver SFP with MSA

Fiber Channel 2.125Gbps Multimode Optical Transceiver SFP with MSA

SFP-1000BASE-LX-LEG. 1.25Gbps SFP Transceiver

SFP-CWDMxx.60. CWDM* Wavelength (0 to 70 o C)

GLC-SX-MM-LEG. 1.25Gbps SFP Transceiver

GLC-LH-SM-LEG-5PK. 1.25Gbps SFP Transceiver

AXFT Mbps~155Mbps Single Fiber Bi-directional SFP, ONU Transceiver

AXGE Gbps Single-mode 1310nm, SFP Transceiver

PT (2)-1W. OC-3 SR/IR-1 / STM S-1.1 SFP Transceiver

Singlemode 1.25Gbps Optical Transceiver SFP with MSA

125Mbps~155Mbps Multimode 850nm, SFP Transceiver

GLC-LH-SM-TX. Product Features. Applications. General. Cisco Compatible 1000BASE-LX/LH SFP TurboX

SFP CWDM 1.25G nm Single mode Optical Transceiver

UK - SFP MONOMODO 20 KM 1310 NM. DTS3112L - C(D)

JD061A-C. 1.25Gbps SFP Transceiver

1.25Gbps Single Fiber Bi-directional SFP, ONU Transceiver

SNR-SFP-LX 1.25Gbps. Features. Applications. Product Description

155Mbps Single-mode 1310nm, SFP Transceiver

PT (2)-1W(+) GbE 1000Base-LX 10 km SFP Transceiver

SO-SFP-1000BASE-ZXD-I

OCTECH 1.25Gbps SFP Transceiver

SFP Module DB1310-SFP-SC.S20 DB1550-SFP-SC.S20. Features. Applications. Ordering information

DATASHEET 4.1. SFP, 100Mbps-2.7Gbps, Multirate, 1310nm, SM, DDM, 8dB, 2km, ind.temp.

SO-SFP-10GE-LR20-I. SFP+, 10GBase-LR, 1310nm, SM, DDM, 11.4dB, 20km ind.temp. OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION

Single Fiber 1.25Gbps Bi-directional Optical Transceiver SFP with Digital Diagnostics

1.25Gb/s SFP Transceiver P/N: MO-C-S31123CDL20. Product Features. Applications. General. Regulatory Compliance. Up to 1.

ROHS Compliant MM SFP Transceiver 1.25Gb Gigabit Ethernet

OCTECH 1.25Gbps SFP Transceiver

DATASHEET 4.3. SFP+, 10GBase-LR, 1310nm, SM, DDM, 70km, RX sensitivity -22 dbm, Ind.temp.

SFP 4.25G 850nm Multi mode Optical Transceiver

BO05C13610 SFP 1.25G 1310nm 10KM RoHS Compliant Optical Transceiver

10Gbps 1270/1330nm SFP+ BIDI TRx 40km

BIDI SFP Series. Part No. Data Rate Wavelength Interface Temp. DDMI

Standard Operating Temperature: -10 C ~ 70 C. Parameter Symbol Min. Max. Unit Note

Part Number Operating temperature DDMI. APS31123CXL2 Commercial No. APS31123CDL2 Commercial Yes. APS31123IXL2 Industrial No

SPL EBX-IDFM SPL EBX-IDFM

PRODUCT FEATURES APPLICATIONS. Pin Assignment: 1 Gigabit Long-Wavelength SFP Transceiver SFP-SX-MM

APSB53123xxL20. Product Features. Applications. General. 1.25Gb/s BiDi SFP Transceiver

SFP Dual LC 1.25G SMF 20Km 1310nm Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

LX21 100Mb/s to 1.25Gb/s BX-U

Regulatory Compliance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge to the enclosure Electromagnetic Interference (EMI)

SFP Series IOLS-1348-XXXX. 4.25Gbps up to 30 km transmission. version 0.1 FEATURES PRODUCT DESCRIPTION

Transcription:

Features GP-3124-L2x(D) 1.25Gbps SFP Optical Transceiver, 20km Reach Dual data-rate of 1.25Gbps/1.063Gbps operation 1310nm FP laser and PIN photodetector for 20km transmission Compliant with SFP MSA and SFF-8472 with duplex LC receptacle Digital Diagnostic Monitoring: Internal Calibration or External Calibration Compatible with SONET OC-24-LR-1 Compatible with RoHS +3.3V single power supply Operating case temperature: Standard : 0 to +70 C Extended : -20 to +85 C Industrial : -40 to +85 C Applications Gigabit Ethernet Fiber Channel Switch to Switch interface Switched backplane applications Router/Server interface Other optical transmission systems Description The SFP transceivers are high performance, cost effective modules supporting dual data-rate of 1.25Gbps/1.0625Gbps and 20km transmission distance with SMF. The transceiver consists of three sections: a FP laser transmitter, a PIN photodiode integrated with a trans-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety Address: 5F, Main Building SheKou Technology Building,No.1059 Page 1 of 9

requirements. The transceivers are compatible with SFP Multi-Source Agreement (MSA) and SFF-8472. For further information, please refer to SFP MSA. TD+/- TxFault TxDis LD Driver LD LOS RD+/- Post Amp PIN+TIA SCL SDA EEPROM MCU ADC/DAC Vcc Temp Absolute Maximum Ratings Table 1 - Absolute Maximum Ratings Parameter Symbol Min Max Unit Supply Voltage Vcc -0.5 4.5 V Storage T emperature Ts -40 +85 C Operating Humidity - 5 85 % Recommended Operating Conditions Table 2 - Recommended Operating Conditions Parameter Symbol Min Typical Max Unit Operating Case Temperature Standard Industrial Tc 0 +70-20 +85-40 +85 Power Supply Voltage Vcc 3.13 3.3 3.47 V Power Supply Current Icc 300 ma Data Rate Gigabit Ethernet 1.25 Gbps C C Address: 5F, Main Building SheKou Technology Building,No.1059 Page 2 of 9

Fiber Channel 1.063 Optical and Electrical Characteristics GP-3124-L2x(D): (FP and PIN, 1310nm, 20km Reach) Table 3 - Optical and Electrical Characteristics Parameter Symbol Min Typical Max Unit Notes Transmitter Centre Wavelength λc 1260 1310 1360 nm S pectral Width (RMS) λ 4 nm Average Output Power Pout -9-3 dbm 1 Extinction Ratio ER 9 db Optical R ise/fall Time (20% ~80%) tr/tf 0.26 ns Data Input Swing Differential V IN 400 1800 mv 2 Input Differential Impedance Z IN 90 100 110 Ω TX Disable TX Fault Disable 2.0 Vcc V Enable 0 0.8 V Fault 2.0 Vcc V Normal 0 0.8 V Receiver Centre Wavelength λc 1260 1580 nm Receiver Sensitivity -23 dbm 3 Receiver Overload 0 dbm 3 LOS De-Assert LOS D -24 dbm LOS Assert LOS A -35 dbm LOS Hysteresis 1 4 db Data Output Swing Diffe rential Vout 400 1800 mv 4 LOS High 2.0 Vcc V Low 0.8 V Address: 5F, Main Building SheKou Technology Building,No.1059 Page 3 of 9

Notes: 1. The optical power is launched into SMF. 2. PECL input, internally AC-coupled and terminated. 3. Measured with a PRBS 2 7-1 test pattern @ 1250Mbps, BER 1 10-12. 4. Internally AC-coupled. Timing and Electrical Table 4 - Timing and Electrical Parameter Symbol Min Typical Max Unit Tx Disable Negate Time t_on 1 ms Tx Disable Assert Time t_off 10 µs Time To Initialize, including Reset of Tx Fault t_init 300 ms Tx Fault Assert Time t_fault 100 µs Tx Disable To Reset t_reset 10 µs LOS Assert Time t _loss_on 100 µs LOS De-assert Time t_loss_off 100 µs Serial ID Clock Rate f_serial_clock 400 KHz MOD_DEF (0:2)-High V H 2 Vcc V MOD_DEF (0:2)-Low V L 0.8 V Diagnostics Table 5 Diagnostics Specification Parameter Range Unit Accuracy Calibration Temperature 0 to +70-40 to +85 C ±3 C Internal / External Voltage 3.0 to 3.6 V ±3% Internal / External Bias Current 0 to 100 ma ±10% Internal / External TX Power -9 to -3 dbm ±3dB Internal / External Address: 5F, Main Building SheKou Technology Building,No.1059 Page 4 of 9

RX Power -23 to 0 dbm ±3dB Internal / External Digital Diagnostic Memory Map The transceivers provide serial ID memory contents and diagnostic information about the present operating conditions by the 2-wire serial interface (SCL, SDA). The diagnostic information with internal calibration or external calibration all are implemented, including received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring. The digital diagnostic memory map specific data field defines as following. Address: 5F, Main Building SheKou Technology Building,No.1059 Page 5 of 9

Pin Definitions Pin Diagram Address: 5F, Main Building SheKou Technology Building,No.1059 Page 6 of 9

Pin Descriptions Pin Signal Name Description Plug Seq. Notes 1 V Transmitter Ground 1 EET 2 TX FAULT Transmitter Fault Indication 3 Note 1 3 TX DISABLE Transmitter Disable 3 Note 2 4 M OD_DEF(2) SDA Serial Data Signal 3 Note 3 5 MOD_DEF(1) SCL Serial Clock Signal 3 Note 3 6 MOD_DEF(0) TTL Low 3 Note 3 7 Rate Select Not Connected 3 8 LOS Lo ss of Signal 3 Note 4 9 V EER Receiver ground 1 10 V EER R eceiver ground 1 11 V EER Receiver ground 1 12 RD- Inv. Received Data Out 3 Note 5 13 RD+ Received Data Out 3 Note 5 14 V EER Receiver ground 1 15 V CCR Receiver Power Supply 2 16 V CCT Transmitter Power Supply 2 17 V EET Transmitter Ground 1 18 TD+ Transmit Data In 3 Note 6 19 TD- Inv. Transmit Data In 3 Note 6 20 V EET T ransmitter Ground 1 Notes: Plug Seq.: Pin engagement sequence during hot plugging. 1) TX Fault is an open collector output, which shou ld be pulled up with a 4.7k~10kΩ resistor on the host board to a voltage between 2.0V and Vcc+0.3V. Logic 0 indicates normal operation; Logic 1 indicates a laser fault of some kind. In the low state, the output will be pulled to less than 0.8V. 2) TX Disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7k~10kΩ resistor. Its states are: Low (0 to 0.8V): Transmitter on (>0.8V, < 2.0V): Undefined High (2.0 to 3.465V): Transmitter Disabled Open: Transmitter Disabled 3) Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7k~10kΩ resistor on the host board. The pull-up voltage shall be VccT or VccR. Mod-Def 0 is grounded by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID 4) LOS is an open collector output, which should be pulled up with a 4.7k~10kΩ resistor. Pull up voltage between 2.0V and Vcc+0.3V. Logic 1 indicates loss of signal; Logic 0 indicates normal operation. In the low state, the output will be pulled to less than 0.8V. 5) RD-/+: These are the differential receiver outputs. They are internally AC-coupled 100 differential lines which should be terminated with 100Ω (differential) at the user SERDES. 6) TD-/+: These are the differential transmitter inputs. They are internally AC-coupled, differential lines with 100Ω differential Address: 5F, Main Building SheKou Technology Building,No.1059 Page 7 of 9

termination inside the module. Recommended Interface Circuit Address: 5F, Main Building SheKou Technology Building,No.1059 Page 8 of 9

Mechanical Dimensions Ordering information Part Number Product Description GP-3124-L2C 1310nm, 1.25Gbps, 20km, 0ºC ~ +70ºC GP-3124-L2CD 1310nm, 1.25Gbps, 20km, 0ºC ~ +70ºC, With Digital Diagnostic Monitoring GP-3124-L2N 1310nm, 1.25Gbps, 20km, -20ºC ~ +85ºC GP-3124-L2ND 1310nm, 1.25Gbps, 20km, -20ºC ~ +85ºC, With Digital Diagnostic Monitoring GP-3124-L2T 1310nm, 1.25Gbps, 20km, -40ºC ~ +85ºC GP-3124-L2TD 1310nm, 1.25Gbps, 20km, -40ºC ~ +85ºC, With Digital Diagnostic Monitoring E-mail: sales@ gigalight.com.cn Web : http://www.gigalight.com.cn Address: 5F, Main Building SheKou Technology Building,No.1059 Page 9 of 9