media:scape HDVC Wall Mount

Similar documents
FlexFrame - Storage Components and Skins

Privacy Wall Glass Selections - Polished Edge Slider Door

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Pathways Privacy Wall Glass Selections - Sliding Door

Installing flat panels on the MPL15 wall mount

OB1U INSTALLATION INSTRUCTIONS. Interactive Flat Panel Over White Board Mount

487 Cachet Swivel - Base Chair Replace Front Seat Support or Seat

Answer Power Beam and Boundary Screen

c:scape Shared Tables - Freestanding and Tethered

TITAN2-EDGE Public Access Computer Station Dual Track

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Screens

Premium Whiteboard and Tackboard Mounting

Video Wall Installation Instructions 2W X 3H, 3W X 3H

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

110 and 555 Markerboard, Chalkboard and Tackboard Mounting

INSTALLATION INSTRUCTIONS DODGE RAM 2 & 4WD 1500 PART # P5058

INSTALLATION INSTRUCTIONS

434 Cobi Chair - Seat Shell Replacement

Opus Standard Corner Trim Unit

a.k.a. casegoods instructions

Desk/Wall-Mount Rack

Height Adjustable Benching End Panel and Utility Pole

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Displays

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Tilting & Swiveling Plasma/LCD Flat Panel Wall Mount Installation Guide Model: A380SM

Installation and Assembly: Full Service Video Wall Mount

DX-TVMLPTB03. Low-Profile TV Wall Mount ASSEMBLY GUIDE. For either wood-stud or concrete wall installations

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

Modular & Hardwired Hub Assembly to "X" and "Y" Posts

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

LAN Locker Adjustable Shelves

INSTALLATION INSTRUCTIONS GRILLE GUARD RAM 1500 PART # 5058/5058-2

Mounting a BalanceBox 400 to a brick wall

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED

Assembly Instructions for Model: VMPR1

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

Mount to the Wall INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS

SB-WM-ART2-L-BL SB-WM-ART2-XL-BL

SmartView Mounting Frame 3 Wide x 3 Deep Video Wall Display Installation Guide

Installation Instruction

MM750 Installation Instructions

Installation and Assembly: Articulating Swivel Arm for 37" - 60" Flat Panel Displays

INSTALLATION INSTRUCTIONS. PLASMA TV WALL MOUNT TILT Universal (RGTU-210) WARNINGS WARNING

LARGE FLAT PANEL DISPLAY STATIC MOUNT PST 2000 Series

Flat Panel Tilt Wall Mount (GPM-111)

INSTALLATION INSTRUCTIONS Small Flat Panel Mounts Model: F-Series

Adjustable Wall Mount and Adjustable Mobile Stand for the PolyVision PJ920 Ultra-Short Throw Projector. Installation Guide

INSTALLATION INSTRUCTION

Fixed Wall Arm. Installation Guide. Part number Rev E 2012 PolyVision Corporation All rights reserved

SM-RAZOR-T-M/L/XL. Strong Low Profile Tilt Mount for Ultra-Thin Flat-Panel TVs INSTRUCTION MANUAL

3 wide x 3 deep Video Wall Display Installation Guide

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

TOOLS REQUIRED FOR ASSEMBLY. Rubber Mallet or Plastic Tip Hammer PARTS REQUIRED FOR ASSEMBLY OF SINGLE ENTRY STARTER.

Installation and Assembly: 32" - 60" Flat Panel TV Cart

Large Case Storage - Counterweights

MSP-DCCPGSU Large Screen Static Display Mount

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Flat Panel Stand FPZ-655. for 32" to 55" Flat Panel Screens FEATURES. Reinforced universal adapter plate for a strong hold

MSP-DCCPGTU Large Screen Tilt Display Mount

Assembly Instructions for Model: VMPL3

EDGE2 DUAL MONITOR ARM

Assembly Instructions for Model: MF110

Mounting Instructions Item No.: xxx

ēno one Adjustable Wall Mount and Adjustable Mobile Stand Installation Guide

Gared Pro-S Portable Backstop

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

Assembly Instructions for Model: VMDD26

PROFILE Flat Panel Console System Installation Manual

Single Sided Height Adjustable Benching

Series 7 AdjusTable Height Tables

EPPA2-KIT DUAL MONITOR ARM CONVERSION

Installation and Assembly: LCD UPRIGHT STAND FOR PEDESTAL CABINETS

Interactive Monitor Arm

SB-WM-ART1-M-BL. Weatherproof Universal Single-Arm Articulating Mount for Medium Displays INSTALLATION MANUAL

SM-RAZOR-ART2-L / SM-RAZOR-ART2-XL

TYGER GUARD. Parts List BEFORE INSTALLATION WARNING TG-GD6D /7. Tyger Guard. Tube Brackets (Bull Bar) passenger or driver side

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

INSTALLATION INSTRUCTIONS Small Flat Panel FMA Pivot Arrays Models: FMA-220 and FMA-320

IMPULSE G2/PULSE STATIC BRIDGE & RETURN MODULE. Drill. Desk Connecting. Outside by fastening the supplied wood screws from the HK-67 kit through the

Opus Base Unit Assembly

Frameless Fixed Panel Slider


19 to 39 TV WALL MOUNT - FULL MOTION

Side Mount INSTRUCTION BOOKLET #C122 BED STYLE: PARK CITY

INSTALLATION TORSION SPRING FRONT OR REAR MOUNT LOW HEADROOM. 1 Cutting Vertical Track. 2 Fully Adjustable Jamb Brackets

Installation and Assembly: Flat Panel Pull-out Swivel Wall Mount


TV Floor Cart and Accessories

Installing Brackets to Minimize Distortion in Your SMART Board 685ix Interactive Whiteboard System s Projected Image

Transcription:

Dual Shroud media:scape HDVC Wall Mount Single Shroud CAUTION Quad Shroud FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. Triple Shroud Read the entire Assembly Direction before beginning installation or assembly. Building construction varies greatly and is outside Steelcase's control. The Building's Engineer of Record is responsible for the design of studs, backing, reinforcement, supporting members etc. which the units are attached to and must verify the adequacy of the mounting hardware. These instructions and any hardware provided by Steelcase are for convenience only and are not an indication of what may be required by your local Code. Dual Shroud with Bridge & Codec Case Attachment Total load of each monitor bracket (monitor + monitor bracket) MAXIMUM WEIGHT - 200 LBS (92 kg.) 3/32", 1/8", 3/16" HEX DRIVE The building owner or designated agent is responsible for verifying that the installation is in compliance with all local Codes and regulations. Topic Table of Contents Page Standard Wall Mount Shroud 2 Codec Wall Mount Shroud 7 Bridge Attachment 10 If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE (888.783.3522) for immediate action by people who want to help you. (Outside the U.S.A., Canada, Mexico, Puerto Rico, and the U.S. Virgin Islands, call: 1.616.247.2500) Or visit our website: www.steelcase.com 2010 Steelcase Inc. Grand Rapids, MI 49501 U.S.A. Printed in U.S.A. WARNING: All electrical installations should be done by a qualified person in accordance with codes and regulations applicable at the installation site. PDR Panel Display Mount 11 Codec Case Attachment 12 Seismic Wall Mount Shroud 14 Shroud Camera Mount 18 Totem Camera Mount 18 Shroud Hole Locations and 19 Additional Dimensions Page 1 of 19

1/4" GAP Standard Wall Mount Shroud NOTE: Unit comes assembled. You must first remove all tubing from the shroud. For the top tube, loosen the top screws a 1/4" and slide screws out of the keyhole slots. For the bottom tube, remove screws completely to remove tubing. NOTE: The installation of the horizontal wall mount depends on there being an adequate wall to support the weight of the shroud and monitor assembly. This procedure is specifically for mounting to a metal stud wall that has a maximum of 24" between centers and minimum metal guage of 25 (.017" thick). The position of the shroud relative to the studs must conform to steps 4 & 5. Once location is determined, installation can proceed according to the following steps. Standard Wall Mount Shroud (If installing with a bridge, see page 10 before continuing. For additional shroud dimensions, see page 19.) 1 3-7/16" TO C L OF SLOT 1-9/16" C L TO CL NOTE: Mounting hardware is to be specified/verified by the Building's Engineer of Record. Install fasteners per the hardware manufacturer's instructions. CAUTION: Be careful not to cut/drill through any wires that may be hidden in the wall. 1. Determine height of shroud from floor. Shroud height Dim. X (See chart on page 3) 1-9/16" C L TO CL Page 2 of 19

3 2. Mark the top horizontal lines using a level. 3. Find and mark all stud locations near desired position on the wall. Determine edges of studs. 4. Adjust horizontal tube position to have most possible hole locations line up with the center of a stud in the wall (4a). On sizes that require two (2) top tubes, make sure to butt tubes tight together (4b). 5. The attachment slots on both ends need to be structurally attached to the building wall. One of the end attachment slots need to be structurally attached to a stud, while the other end also needs to be structurally attached, if not by a stud then by another structurally appropriate attachment method depending on the wall construction. 2 Size 32 Sgl 32 Dbl 32 Triple 32 Quad 42 Sgl 42 Dbl 42 Triple 42 Quad 46 Sgl 46 Dbl 46 Triple 55 Sgl 55 Dbl 55 Triple 65 Sgl 65 Dbl 65 Triple 42 Dbl 42 Triple 46 Dbl 46 Triple Dim X Dim Y Dim Z Standard and Seismic 14-7/8" 14-7/8" 14-7/8" 36-1/2" 19-1/8" 19-1/8" 19-1/8" 45-3/8" 22" 22" 22" 26-5/8" 26-5/8" 9-3/4" 9-3/4" 9-3/4" 9-1/2" 9-3/4" 14" 9-3/4" 10-1/4" 15" 12" 15" 12-1/2" 11-5/8" 14-5/8" 12-1/8" 15" 26-5/8" 12-1/2" 13-3/4" 32" 32" 32" 19-1/8" 19-1/8" 22" 22" 9-3/4" 9-3/4" Codec 8" 8" 12-5/8" 11-3/4" 10-3/4" 15" 12" 11-5/8" 14-7/8" Shroud Ht. 23-3/8" 23-3/8" 23-3/8" 45" 27-5/8" 27-5/8" 27-5/8" 53-7/8" 30-1/2" 30-1/2" 30-1/2" 35-1/8" 35-1/8" 35-1/8" 40-1/2" 40-1/2" 40-1/2" 27-5/8" 27-5/8" 30-1/2" 30-1/2" ON A STUD 5-1/2" REF. 2-1/2" 5-1/2" REF. ON A STUD 8" TYPICAL WALL Dim. Z Dim. Y STRUCTURALLY APPROPRIATE ATTACHMENT OVERALL DEPTH 5-1/2" (STD.) 7" (CODEC) 1" (STD.) 2-1/2" (CODEC) 15/32" 1-9/16" 3-15/32" 4a C L C L Dim. X SHROUD HEIGHT C L X 4b STUD FLOOR LINE 5 Page 3 of 19

6a 6b 6. Mark hole locations (studs and/or drywall locations) (6a) and attach tube accordingly depending on the wall construction that is at that location (6b). NOTE: Fasteners are not provided. Fasteners must be used in both top & bottom holes of each tube. 7. Verticals are positioned using the edge of the top horizontal tube as a guide. Position tight into corner (7a) and use a level or large carpenters square to plumb vertically (7b). 8. Mark center of horizontal slots of vertical brackets. 9. Attach vertical brackets to wall accordingly depending on the wall construction that is at that location. NOTE: Fasteners are not provided. TOP HORIZONTAL TUBE 7a 7b VERTICAL 8 8 9 Page 4 of 19

10 Front View 10. Measure across corners of verticals to check for squareness before securing to wall. VERTICAL 11. A bottom horizontal tube is required for duals that are greater than 80" wide (42" product and larger) and for all triples & quads. The bottom horizontal tube is included when it's required and does not need to be ordered seperately. NOTE: A bottom horizontal tube is not required for all singles. 12. Mark/draw line from the bottom of the two (2) verticals. 13. Determine and mark the centerline between the two verticals on the wall. VERTICAL MARK LINE FROM THE BOTTOM OF THE TWO VERTICALS 13 12 14. Determine and mark the centerline on the narrow tube. C L 15. Position bottom horizontal tube aligning the bottom of the tube with horizontal line (while level) and centerline marks, while marking the attachment hole locations on the wall. 14 VERTICAL MARK LINE FROM THE BOTTOM OF THE TWO VERTICALS 15 C L Page 5 of 19

16 1/4" GAP 17 17 KNOCKOUT NOTE: If knockout needs to be removed for camera wires, insert flat-bladed screwdriver and rotate. 16. Attach bottom horizontal tube to the wall accordingly depending on the wall construction that is at that location. NOTE: Fasteners are not provided. Fasteners must be used in both top & bottom holes of each tube. 17. Verify all colored washers at all keyhole slots on the upper tube with provided fasteners. Leaving approximately 1/4" gap from tube. TIP: Knockout appropriate wire management locations, determined by the A.V. integrator before continuing. 17 17 18b FASTENER KEYHOLE SLOT 18c 18d 18. Attach shroud by lifting keyhole slots over protruding fasteners on the top tube. 18a 20b 19. Check for alignment of all fasteners and adjust as necessary prior to securing all shroud fasteners in place. 20a 20. Secure shroud using provided screws in all locations. Top & bottom tubes (20a) and verticals (20b). 20b SHROUD Page 6 of 19

Codec Wall Mount Shroud 1/4" GAP NOTE: Mounting hardware is to be specified/verified by the Building's Engineer of Record. Install fasteners per the hardware manufacturer's instructions. 2 3a 1. Perform steps 1 through 6 of the "Standard Wall Mount Shroud" on pages 2 and 3. NOTE: Make sure to pay attention to the tube orientation. The tab at the end of the tubes go toward the inside as shown. TEMPLATE 2. Verify provided fasteners are mounted at keyhole slots on upper tube. Leaving approximately a 1/4" gap away from the tube. 3. Position bottom horizontal tube by hanging the provided templates. Use upper hole for a shroud height of 27-5/8" (42" product) and lower hole for a shroud height of 30-1/2" (46" product) (3a). Use a level or large carpenters square to plumb vertically, while making sure the bottom horizontal tube is pressed tightly to wall (3b). 3b BOTTOM HORIZONTAL TUBE Page 7 of 19

4 4. Measure across corners of verticals to check for squareness. 5. Mark all hole locations on the bottom horizontal tube. 6. Verify squareness. Attach bottom horizontal tube to wall, accordingly depending on the wall construction that is at that location. NOTE: Fasteners are not provided. Fasteners must be used in both top & bottom holes of each tube. 5 CODEC BOX Z-BRACKET FOR CODEC BOX 7. Remove template brackets. 8. Locate and install spring clips on tabs on both ends of both horizontal tubes. 9. Locate & install z-brackets for codec box. Position as required, so codec box can slide in from the desired side. NOTE: Fasteners are not provided. TIP: Knockout appropriate wire management locations, determined by the A.V. integrator before continuing. Install/place wires for codec unit. 8 KNOCKOUT TAB SPRING CLIP NOTE: If knockout needs to be removed for camera wires, insert flat-bladed screwdriver and rotate. 6 9 6"-12" Page 8 of 19

10b 10c KEYHOLE SLOT 10d 10. Attach shroud by lifting keyhole slots over protruding fasteners on the top tube. FASTENER 11. Check alignment of all fasteners and adjust as necessary prior to securing all shroud fasteners in place. 12. Secure shroud, using provided screws, to all locations (top and bottom tubes). 13. Snap in the perforated vertical covers over clips. TIP: Lock features are provided for use with an aftermarket lock such as Kensington. 10a 12 12 13 12 13 SHROUD Perforated vertical covers let heat dissipate from the codec unit and allows access to hardware for services. VERTICAL COVER Page 9 of 19

3-5/16" TO C OF SLOT L 1-9/16" C L TO CL Bridge Attachment SHROUD HEIGHT NOTE: Not for seismic or codec versions of shrouds. 5-1/16" 1. In order to attach the bridge to the table it is important that shrouds be positioned relative to media:scape table heights. Lounge Height = 23-1/8" from floor. Desk Height = 28-5/8" from floor. LOUNGE HT. - 23-1/8" DESK HT. - 28-5/8" STANDING HT. - 38-1/8" 3a 3b Standing Height = 38-1/8" from floor. 2. Follow steps 1 through 10 of the "Standard Wall Mount Shroud" on pages 2 through 5. BRIDGE 3. Attach bridge behind shroud and secure in place in the vertical slots with two (2) 5/16-18 x 3/4" long screws. 5 4. Slide table into position and level. 5. Align and attach bridge holes with inserts in worksurface. This will level bridge to the correct height on the shroud. 4 6. Secure bridge/shroud holes in slot from step 3. Page 10 of 19

7 8 PYRAMID COVER 7. After managing necessary wires, install wire cover by securing in place using two (2) 5/16-18 x 7/8" button head screws. NOTE: Wire cover not provided, ordered seperately. 8. Install pyramid covers with necessary 5/16-18 x 7/8" button head screws. (Reference media:scape installation manual, if necessary.) PDR Panel Display Mount 1. Locate the PDR package & hardware bag. 2. Choose from the three (3) possible positions, depending on the size and make of the television. Install wall mount bracket from PDR kit, with fasteners provided in Steelcase hardware bag (not from kit), to the shroud. Note the flange orientation of the wall mount bracket. 3. See installation direction 'PDM120THN Panel Mount Display' that is inside the panel display mount box. Install display brackets, plastic spacers (optional), gravity lock brackets provided in Steelcase hardware bag and adjust the lateral movement per the manufacturer's specifications. 5/16-18 X 7/8" BUTTON HEAD SCREW WIRE COVER POSITION #1 POSITION #2 POSITION #3 5/16-18 X 7/8" BUTTON HEAD SCREW 2 SHOWN IN POSITION #2 Total load of each monitor bracket (monitor + monitor bracket) MAXIMUM WEIGHT - 200 LBS (92 kg.) FLANGE UP Page 11 of 19

Codec Case Attachment 2a NOTE: Be careful not to pinch any wires that may already be installed through this area. 1. Align the four (4) holes on the bridge with the four (4) holes on the codec case and attach with four (4) 5/16-18 x 3/8" long fasteners provided. The perforated cover must be removed for the 5-1/2" thick version and does not need to be removed for the 2-1/2" version. 2. To remove the perforated codec cover, remove two (2) screws at the top (2a) and rotate the top outwards (2b). CODEC CASE BRIDGE 5/16-18 x 3/8" LONG FASTENER 1 2b Perforated cover lets heat dissipate from the codec unit and allows access to hardware for services. Page 12 of 19

3 3. Install strap by feeding through either set of slots so that the connections points are accessible from the front. 4a TIP: Lock features are provided for use with an aftermarket lock such as Kensington. 4. To install the codec cover, position the two (2) hooks on the two (2) tabs (4a) and rotate the top upwards (4b). Tight fit (resistance) is to reduce rattling. Secure in place with two (2) #10 x 1/4" long screws (provided) (4c). NOTE: Modifications may be necessary to retrofit totem bridges. Mark and drill accurately to dimensions shown. After drilling, tap the four (4) holes 5/16-18 thread. Side View 4b Side View 4c 8" 5-1/8" 3" 2-5/8" HOOK TAB Page 13 of 19

Seismic Wall Mount Shroud Front View 1. Perform steps 1 through 10 of the "Standard Wall Mount Shroud" on pages 2 through 5. VERTICAL 2. Position bottom horizontal tube tight into corners of both verticals. 2 3. Adjustments may be needed to the verticals to make sure the bottom horizontal tube fits tight. C L 4. Measure across corners of verticals to check for squareness before securing to wall. 4 C L Page 14 of 19

5 5. Mark all hole locations on the bottom horizontal tube. 6. Attach bottom horizontal tube accordingly depending on the wall construction that is at that location (6a). On sizes that require two (2) bottom tubes, make sure to butt tubes tight together (6b). NOTE: Fasteners are not provided. Fasteners must be used in both top & bottom holes of each tube. 7. On sizes that require two (2) bottom tubes: Check the spacing of the top tube to the bottom tube at the center seam (7a). Make sure the spacing is equal at both ends of the tube (7b). 6a 7a 6b 7b Page 15 of 19

1/4" GAP 8 8 KNOCKOUT NOTE: If knockout needs to be removed for camera wires, insert flat-bladed screwdriver and rotate. 8. Verify all colored washers at all keyhole slots on the upper tube with provided fasteners. Leaving approximately 1/4" gap from tube. TIP: Knockout appropriate wire management locations, determined by the A.V. integrator before continuing. 8 8 9b KEYHOLE SLOT 9. Attach shroud by lifting keyhole slots over protruding fasteners on the top tube. 9a FASTENER 9c 9d SHROUD Page 16 of 19

10. Check for alignment of all fasteners and adjust as necessary prior to securing all shroud fasteners in place. 11a 11. Secure shroud using provided screws in all locations. Top & bottom tubes (11a) and verticals (11b). 11a 11b 11a 11a 11a 11a 11b Page 17 of 19

SHROUD CAMERA SHELF 1a Shroud Camera Mount 1. To install a shroud camera shelf, loosen set screw (by turning counter-clockwise) enough to lower shelf onto top of shroud (1a). On back of shelf, using an Allen wrench tighten set screw by turning clock-wise (1b). Mount camera on top of shelf by installing camera mount screw on bottom of shelf and turning clock-wise (1c). NOTE: DO NOT over tighten set screw. Totem Camera Mount 2. To install a totem camera shelf, loosen set screw (by turning counter-clockwise) enough to slide shelf onto totem (2a) so that bracket underneath the shelf engaged with totem (2b). On top of shelf, using an Allen wrench tighten set screw by turning clock-wise (2c). Mount camera on top of shelf by installing camera mount screw on bottom of shelf and turning clock-wise (2d). NOTE: DO NOT over tighten set screw. 1b 2a TOTEM CAMERA 2b CAMERA SHELF TOTEM BRACKET TOTEM SHELF 2c TOTEM 1c 2d Page 18 of 19

D (Overall Width) D (Overall Width) Shroud Hole Locations: A A Use chart to aid in positioning of any holes that maybe required in the wall behind the shrouds. NOTE: Reference PDR Panel Display Mount (page 11) for the possible positions of the wall mount bracket that could interfere with anything behind the shroud. B B Single Monitor B D (Overall Width) C Dual Monitor B Style No. Single Monitor MTSWS32 MTSWS42 MTSWS46 MTSWS55 MTSWS65 Dual Monitor MTSWD32 MTSWD42 MTSWD46 MTSWD55 MTSWD65 11.70" 13.80" 15.25" 17.55" 20.25" 11.70" 13.80" 15.25" 17.55" 20.25" 17.56" 22.21" 24.51" 28.16" 32.66" 17.56" 22.21" 24.61" 28.16" 32.66" Dual Monitor with CODEC Case MTSWD42C MTSWD46C Triple Monitor MTSWT32 MTSWT42 MTSWT46 MTSWT55 MTSWT65 13.80" 15.25" 11.70" 13.80" 15.25" 17.55" 20.25" 22.21" 24.61" 17.56" 22.21" 24.71" 28.16" 32.66" Triple Monitor with CODEC Case MTSWT42C MTSWT46C Quad Monitor MTSWQ32 MTSWQ42 Dim. A Dim. B Dim. C Dim. D 13.80" 22.21" 15.25" 24.71" 11.70" 17.56" 13.60" 22.21" NA NA NA NA NA 32.43" 41.73" 46.12" 53.62" 62.12" 41.72" 46.12" 32.43" 41.73" 46.12" 53.62" 62.12" 41.73" 46.12" 32.43" 41.73" 35.00" 44.00" 48.50" 56.00" 65.00" 67.00" 86.00" 95.00" 109.50" 127.00" 86.00" 95.00" 99.50" 127.50" 141.50" 163.00" 189.50" 127.50" 141.50" 67.00" 86.00" B C Triple Monitor 10-1/2" Hole pattern C 5" 2-1/2" B B C A D (Overall Width) Quad Monitor B A A Page 19 of 19