IDEAS+ WP3520 Calibration and data quality toolbox. July 2016 Steve Mackin James Warner

Similar documents
Comprehensive Vicarious Calibration and Characterization of a Small Satellite Constellation Using the Specular Array Calibration (SPARC) Method

ENMAP RADIOMETRIC INFLIGHT CALIBRATION, POST-LAUNCH PRODUCT VALIDATION, AND INSTRUMENT CHARACTERIZATION ACTIVITIES

Multi-sensor data base over desert sites for calibration purpose. P. Henry ¹, X. Briottet ², C. Miesch ², F. Cabot ¹ ¹CNES, ²ONERA

Sentinel-2 Products and Algorithms

Towards the Intercalibration of EO medium resolution multi-spectral imagers : MEREMSII Final Report Executive Summary

Railroad Valley Playa for use in vicarious calibration of large footprint sensors

On-Orbit Radiometric Performance of the Landsat 8 Thermal Infrared Sensor. External Editors: James C. Storey, Ron Morfitt and Prasad S.

Leica ADS80 - Digital Airborne Imaging Solution NAIP, Salt Lake City 4 December 2008

From Proba-V to Proba-MVA

RADIOMETRIC CAMERA CALIBRATION OF THE BiLSAT SMALL SATELLITE: PRELIMINARY RESULTS

OPAL Optical Profiling of the Atmospheric Limb

Two-linear-polarization measurement of O 2 A band with TANSO-FTS onboard GOSAT

LANDSAT 8 Level 1 Product Performance

Status of Aqua MODIS Reflective Solar Bands Calibration and Performance

Landsat-8 Operational Land Imager (OLI) Radiometric Performance On-Orbit

NIST Agency Report May 2012 OUTLINE. The case for traceability NMI capabilities A view to the future the HIP Current/recent NIST activities

RADIOMETRIC CALIBRATION

METimage Calibration & Performance Verification. Xavier Gnata ICSO 2016

The Hyperspectral UAV (HyUAV) a novel UAV-based spectroscopy tool for environmental monitoring

Remote Sensing Platforms

AVHRR/3 Operational Calibration

Using Ground Targets for Sensor On orbit Calibration Support

9/12/2011. Training Course Remote Sensing Basic Theory & Image Processing Methods September 2011

PLANET SURFACE REFLECTANCE PRODUCT

The Advanced Along-Track Scanning Radiometer (AATSR) Mission Status and Early Results

Chapter 5 Nadir looking UV measurement.

Remote Sensing Platforms

Dario Cabib, Amir Gil, Moshe Lavi. Edinburgh April 11, 2011

Part 1: New spectral stuff going on at NIST. Part 2: TSI Traceability of TRF to NIST

Status of MODIS, VIIRS, and OLI Sensors

DEFENSE APPLICATIONS IN HYPERSPECTRAL REMOTE SENSING

metcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 -

Lecture Notes Prepared by Prof. J. Francis Spring Remote Sensing Instruments

R a d i o m e t r i c C a l i b r a t i o n N e t w o r k o f A u t o m a t e d I n s t r u m e n t s

MERIS instrument. Muriel Simon, Serco c/o ESA

Suomi NPP VIIRS Calibration/ Validation Progress Update

High collection efficiency MCPs for photon counting detectors

Cross Track Infrared Sounder (CrIS) Flight Model 1 Test Results

MERIS US Workshop. Instrument Overview. Steven Delwart

Radiometric performance of Second Generation Global Imager (SGLI) using integrating sphere

Kazuhiro TANAKA GCOM project team/jaxa April, 2016

GEOMETRIC RECTIFICATION OF EUROPEAN HISTORICAL ARCHIVES OF LANDSAT 1-3 MSS IMAGERY

Hyperspectral Imager for Coastal Ocean (HICO)

ASSESSMENT BY ESA OF GCOS CLIMATE MONITORING PRINCIPLES FOR GMES

Chapter 5. Preprocessing in remote sensing

AT-SATELLITE REFLECTANCE: A FIRST ORDER NORMALIZATION OF LANDSAT 7 ETM+ IMAGES

Inter-Calibration of the RapidEye Sensors with Landsat 8, Sentinel and SPOT

Reducing Striping and Non-uniformities in VIIRS Day/Night Band (DNB) Imagery

Kepler photometric accuracy with degraded attitude control: Simulation of White Paper Attitude

Preparing Remote Sensing Data for Natural Resources Mapping (image enhancement, rectifications )

High-end CMOS Active Pixel Sensor for Hyperspectral Imaging

Digital Radiography : Flat Panel

Basic Digital Image Processing. The Structure of Digital Images. An Overview of Image Processing. Image Restoration: Line Drop-outs

Camera Requirements For Precision Agriculture

Radiometric Use of WorldView-3 Imagery. Technical Note. 1 WorldView-3 Instrument. 1.1 WorldView-3 Relative Radiance Response

Radiometric Non-Uniformity Characterization and Correction of Landsat 8 OLI Using Earth Imagery-Based Techniques

RADIATION BUDGET INSTRUMENT (RBI): FINAL DESIGN AND INITIAL EDU TEST RESULTS

NORMALIZING ASTER DATA USING MODIS PRODUCTS FOR LAND COVER CLASSIFICATION

Hyperspectral Systems: Recent Developments and Low Cost Sensors. 56th Photogrammetric Week in Stuttgart, September 11 to September 15, 2017

a simple optical imager

Measurement Guide. Solarzentrum Stuttgart GmbH Rotebühlstr. 145, Stuttgart

Remote Sensing 1 Principles of visible and radar remote sensing & sensors

RADIOMETRIC CHARACTERIZATION AND PERFORMANCE ASSESSMENT OF THE ALI USING BULK TRENDED DATA

SMARTSCAN Smart Pushbroom Imaging System for Shaky Space Platforms

IMAGE PROCESSING: AN ENABLER FOR FUTURE EO SYSTEM CONCEPTS

WHITE PAPER. Methods for Measuring Flat Panel Display Defects and Mura as Correlated to Human Visual Perception

Status of the CNES / MicroCarb small

DIGITAL IMAGING. Handbook of. Wiley VOL 1: IMAGE CAPTURE AND STORAGE. Editor-in- Chief

Cross-Talk in the ACS WFC Detectors. II: Using GAIN=2 to Minimize the Effect

Low Cost Earth Sensor based on Oxygen Airglow

Sentinel-3 OLCI and SLSTR

DESIS Applications & Processing Extracted from Teledyne & DLR Presentations to JACIE April 14, Ray Perkins, Teledyne Brown Engineering

International Conference on Space Optics ICSO 2014 La Caleta, Tenerife, Canary Islands 7 10 October /cso _2014 ono ' r

Radiometric Solar Telescope (RaST) The case for a Radiometric Solar Imager,

Compact High Resolution Imaging Spectrometer (CHRIS) siraelectro-optics

Camera Requirements For Precision Agriculture

Application of GIS to Fast Track Planning and Monitoring of Development Agenda

THE SPACE TECHNOLOGY RESEARCH VEHICLE 2 MEDIUM WAVE INFRA RED IMAGER

CCDs for Earth Observation James Endicott 1 st September th UK China Workshop on Space Science and Technology, Milton Keynes, UK

DESIGN AND CHARACTERIZATION OF A HYPERSPECTRAL CAMERA FOR LOW LIGHT IMAGING WITH EXAMPLE RESULTS FROM FIELD AND LABORATORY APPLICATIONS

CIRiS: Compact Infrared Radiometer in Space August, 2017

Advanced Meteorological Imager (AMI) Development for GEO-KOMPSAT-2A

QWG4 RADIOMETRIC CALIBRATION: STATUS. Sindy Sterckx, Stefan Adriaensen, Wouter Dierckx

Advanced Optical Satellite (ALOS-3) Overviews

Experimental Analysis of Luminescence in Printed Materials

MEASURING HEAD-UP DISPLAYS FROM 2D TO AR: SYSTEM BENEFITS & DEMONSTRATION Presented By Matt Scholz November 28, 2018

MTF and PSF measurements of the CCD detector for the Euclid visible channel

Camera Case Study: HiSCI à now CaSSIS (Colour and Stereo Surface Imaging System)

VICARIOUS CALIBRATION SITE SELECTION FOR RAZAKSAT MEDIUM-SIZED APERTURE CAMERA (MAC)

1. INTRODUCTION. GOCI : Geostationary Ocean Color Imager

High-speed Micro-crack Detection of Solar Wafers with Variable Thickness

A CubeSat-Based Optical Communication Network for Low Earth Orbit

NASA OBPG Satellite Ocean Color Update

Receiver Design for Passive Millimeter Wave (PMMW) Imaging

Int n r t o r d o u d c u ti t on o n to t o Remote Sensing

REVIEW OF ENMAP SCIENTIFIC POTENTIAL AND PREPARATION PHASE

EnMAP Environmental Mapping and Analysis Program

Cross Calibration of the Landsat-7 ETM+ and EO-1 ALI Sensor. Gyanesh Chander, David J. Meyer, and Dennis L. Helder, Member, IEEE

Sensor Fusion Enables Comprehensive Analysis of Laser Processing in Additive Manufacturing

Changyong Cao 1, Pubu Ciren 2, Mitch Goldberg 1, and Fuzhong Weng 1. Introduction

Transcription:

IDEAS+ WP3520 Calibration and data quality toolbox July 2016 Steve Mackin James Warner

Proposition : Every image contains the same information Railroad Valley, Nevada London, UK

Rationale for the project By using normal images, we have a much higher sampling density (every image) and hence can monitor and update our results with a much higher frequency than many on-board devices and vicarious methods which use specific sites that can only be accessed infrequently. By using normal images, in theory we can update coefficients automatically as soon as an issue is encountered (detector non-uniformity where a single detector responsivity changes dramatically in a short period of time) We also avoid dead periods where a specific site cannot be used, such as the polar sites in Antarctica and Greenland that for precision work can only be used effectively for one to two months per year.

Areas to be explored The number of areas to be explored has grown with time, given additional knowledge of what can and cannot be extracted from the image data alone. These include (at this time), Signal to Noise Ratio (SNR) Absolute Calibration Drift Relative Gain Correction Single Pixel Drift Spectral Calibration Drift Micro-Vibration and attitude stability Instrument focus

Signal to Noise Ratio (SNR) Developing automated methods to estimate SNR in heterogeneous scenes

Signal to Noise Ratio (SNR) - Simulation Simulated snow scene (SD = 0.64)

Overestimation and underestimation of SNR using automated methods Most automated methods tend to overestimate the SNR for relatively homogeneous surfaces Automated methods have been shown to underestimate the SNR over moderately heterogeneous surfaces

Real surfaces are often mixtures Upper line of data cloud shows the true SNR. Validated using manual methods Allows the monitoring of changes in operational procedures or sensor response Extension of single detectors under investigation

Absolute Calibration Drift The aim is to provide a simple, but effective way of inspecting the calibration of an instrument without complex modelling or processing.

AATSR Instrument - calibration drift VISCAL is a calibration device for the VNIR bands and the 1.6 mm band. Piece of OPAL characterised by NPL in the lab under 0 /45 conditions. Photodiode placed by mirror M2 to monitor the signal, VISCAL data and photodiode information both recorded.

The major assumptions? Basic principles are that we have two independent references on the behaviour of the instrument. Calibrator (reflectance diffuser) If recorded signal of calibrator drops with time then there is degradation in the optics / detector, ASSUMING that the calibration device does not change (using annual averages to avoid sun-earth difference effects) The Earth If recorded signals on average of the earth drop with time then there is degradation in the optics / detector, ASSUMING that the earth does not change (using annual averages to avoid sun-earth distance and seasonal effects).

The Earth s albedo is stable? The Earth as measured by CERES TOA irradiance stability is 0.5 Wm -2 per decade. Negligible drift over the lifetime of AATSR http://lasp.colorado.edu/sorce/news/2011sciencemeeting/docs/presentations/4e_kato_sorce_2011 _presentation.pdf

Principles of operation Level 0 processing If we take annual average values of our data (billions of data points) and take annual average values of our on-board calibrator. We will have two data points with a specific relationship at start of life. Over several years we get a profile. Bias subtracted Count Calibrator Counts Earth Reference Counts time Digital gain changes or common instrument related changes are common to both counts

Validation step - What were RAL s findings? Used a complex processing based on Level 1 To obtain drift RAL compared measured BRF against reference BRF (ATSR-2) for all sites Trend is obtained by averaging drift for all sites of 120 day window filtering for values <2 sigma from mean (5 iterations usually to get stability) Results provide input to drift correction look-up-table 2012 RAL Space

Results - 0.56 micrometre band

Results - 0.66 micrometre

Results 0.87 micrometre

Results 1.6 micrometre band A reasonable result at limits of the quoted uncertainties Is there a reason why the fit is not so good?

Drift table repeat pattern BRDF? Drift data with VISCAL monitor data (blue line), without VISCAL monitor data (red line) and difference (green line)

Relative Gain Calibration This is essentially detector equalisation to avoid striping effects in pushbroom sensors, but in our case using single heterogeneous images

Relative Calibration using the on-board diffuser As long as the diffuser does not vary spatially it should work. The sensitivity to changes in the BRDF of the diffuser with time may be difficult to detect

Relative Calibration using flat-fields Multiple white images over Antarctica or Greenland to derive relative gain terms, yawing the spacecraft, removing scenes with clouds or hoar frost effects.

Relative Calibration using Side Slither PROBLEMS : Landsat 8 has a 15 degree FOV and the CCD relative azimuth to the sun will vary depending on acquisition. Many surfaces will show BRDF effects. The Landsat 8 FPA has staggered arrays with around 1.5 degrees difference. This means you are looking at two targets and inducing a small BRDF difference.

Relative calibration from single heterogeneous images Bias subtracted raw image used to derive the relative gains

Clouds were an issue originally Problematic cloudy image

Instrument Focus The aim in this case is to have a simple metric of the focus condition of any image, affected by electronics, optics, atmosphere etc.

Instrument focus and MTF Algorithm that uses any image to try and determine best focus Which is most in focus?

Instrument focus and MTF These are the images we use, far more difficult. There is no pre-selection (currently), so all these images have been used in the analysis. The bottom right image presents particular challenges, as you can imagine the atmospheric conditions do reduce the effective focus.

Monitoring changes in focus with time Launch plus five years. Focus has changed, now peaks at around 830 steps At launch, best focus Focus was changed in steps from zero, peaks at 550.

Relationship between the focus measure and MTF at Nyquist Quantitative relationship modelled Same image used for MTF and focus assessment. MTF based on small checkerboard target

Monitoring instrumental effects Cross-track variation in Focus (UK-DMC-2) In focus position In focus position CCD Pixel 1 CCD Pixel 14436 1 2 3 4 5

Monitoring instrumental effects Green Red Variation in focus across the FOV is captured Variation in focus value due to charge diffusion effects in the silicon detectors is also captured. NIR

Conclusions Results suggest we can monitor a wide range of parameters on a regular basis with uncertainties similar to those obtained using on-board and other more complex vicarious methods. Using the data we can have a much higher sampling density hence we can deal with instabilities and changes on short time scales and embed automated corrections in our processing chains. Still under development, but we have reached the prototype implementation stage.