Figure 1: Schematic of operation.

Similar documents
HOW THE COMPONENTS OF FORMATION OF FINE PAPER AFFECT PRINTABILITY FOR DIFFERENT PRINTING PROCESSES

HOW THE COMPONENTS OF FORMATION OF FINE PAPER AFFECT PRINTABILITY FOR DIFFERENT PRINTING PROCESSES

Paperboard converting

nanovea.com PROFILOMETERS 3D Non Contact Metrology

Fingerprinting the Gravure Press. Presented by: Bruce G. Beyer GAA 2008 all rights reserved

Bias errors in PIV: the pixel locking effect revisited.

Acoustic resolution. photoacoustic Doppler velocimetry. in blood-mimicking fluids. Supplementary Information

Isolator-Free 840-nm Broadband SLEDs for High-Resolution OCT

ON-LINE TOPOGRAPHY ANALYSIS BY PHOTOMETRIC STEREO METHOD NEW TOOLS FOR TISSUE, PAPER AND BOARD MAKERS

Spatial Filtering of Surface Profile Data

Operational Excellence Success Story

Influence of surface properties of ink jet papers on

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA

Effect of Substrate Topography on Print Quality in Gravure Press

Automated Print Quality Analysis in Inkjet Printing: Case Study Using Commercially Available Media

WRINKLES & PIPING IN PAPER REELS. By: D K Singhal

Rotary sizing of tube and pipe on the mill

MINIATURE X-RAY SOURCES AND THE EFFECTS OF SPOT SIZE ON SYSTEM PERFORMANCE

Manufacturing Metrology Team

A NOVEL METHOD FOR DETERMINING AMOUNT OF INK PRINTED ON PAPER USING X-RAY FLUORESCENCE SPECTROSCOPY

Material analysis by infrared mapping: A case study using a multilayer

Automated Print Quality Analysis in Inkjet Printing: Case Study Using Commercially Available Media

Controlling Fusing Parameters by Optical Image Quality in Electrophotographic Printing

Image-based On-line Measurement of Crepe Structure

"Papermaking, Part 3: Finishing" Edited by Mikko Jokio

Significance of Paper Properties on Print Quality in CIJ Printing

Design of Practical Color Filter Array Interpolation Algorithms for Cameras, Part 2

Single-photon excitation of morphology dependent resonance

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

Microscopic Structures

WHITE PAPER. Methods for Measuring Flat Panel Display Defects and Mura as Correlated to Human Visual Perception

The History and Future of Measurement Technology in Sumitomo Electric

Troubleshooting Guide for Digital Printing on Creative Papers

Module-2 Lecture-1 Angle plate, steel rule, spring calipers. (Refer Slide Time: 00:14)

Optical Performance of Nikon F-Mount Lenses. Landon Carter May 11, Measurement and Instrumentation

COTTON FIBER QUALITY MEASUREMENT USING FRAUNHOFER DIFFRACTION

TOPOGRAPHY & ROUGHNESS TESTING OF SANDPAPER SURFACE

INSTRUMENTATION BREADBOARDING (VERSION 1.3)

PROCESS INTERMITTENT MEASUREMENT FOR POWDER-BED BASED ADDITIVE MANUFACTURING. A.L. Cooke *, S.P. Moylan *

Printing on Corrugated Board

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS

Profilometry: A Technique to Characterize Paper Surface. Pólo II, Pinhal de Marrocos, Coimbra, Portugal

Measurement and alignment of linear variable filters

HIGH THROUGHPUT MINIMUM SET-UP TIME BT-Z LARGE BAR PEELERS

Amorphous Selenium Direct Radiography for Industrial Imaging

white paper l April 2011 LUX in the Corrugated Post-Print Market

Properties of Structured Light

Fast, high-contrast imaging of animal development with scanned light sheet based structured-illumination microscopy

Texture characterization in DIRSIG

Spectral Analysis of the LUND/DMI Earthshine Telescope and Filters

Agilent 8700 LDIR Chemical Imaging System. Bringing Clarity and Unprecedented Speed to Chemical Imaging.

Simulation and test of 3D silicon radiation detectors

Pulsed Thermography and Laser Shearography for Damage Growth Monitoring

Super High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series

An Evaluation of MTF Determination Methods for 35mm Film Scanners

-SQA-SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NG NATIONAL CERTIFICATE MODULE DESCRIPTOR

The following media characteristics affect print quality and reliability. Consider these characteristics when evaluating new media stock.

Report on BLP Spectroscopy Experiments Conducted on October 6, 2017: M. Nansteel

COS: NUV and FUV Detector Flat Field Status

Attenuation length in strip scintillators. Jonathan Button, William McGrew, Y.-W. Lui, D. H. Youngblood

Clairbook. Clairjet 400. Everjet 400. Clairjet 1200

Fast Laser Raman Microscope RAMAN

CONTACT LASER ULTRASONIC EVALUATION OF CONSTRUCTION MATERIALS

Characterizing and Modeling Coalescence in Inkjet Printing

Effect of paper properties on print quality by flexographic method

Temperature Reductions to Mitigate the WF4 Anomaly

Supplementary Figure 1 Reflective and refractive behaviors of light with normal

Technical Explanation for Displacement Sensors and Measurement Sensors

A High-Speed Imaging Colorimeter LumiCol 1900 for Display Measurements

REAL-TIME X-RAY IMAGE PROCESSING; TECHNIQUES FOR SENSITIVITY

Paper Parameters That Affect Color Reproduction. Danny C. Rich, Ph.D. Sun Chemical Color Research Laboratory

Southern African Large Telescope. RSS CCD Geometry

Creasability and foldability

NON UNIFORM BACKGROUND REMOVAL FOR PARTICLE ANALYSIS BASED ON MORPHOLOGICAL STRUCTURING ELEMENT:

APPLICATIONS FOR TELECENTRIC LIGHTING

Ring crush of paperboard (flexible beam method) (REAFFIRMATION of Classical Method T 818 cm-07) (No changes from previous drafts)

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

New Features of IEEE Std Digitizing Waveform Recorders

Process Solutions to Improve Paper Machine Performance in Forming Section with Essential Abstract Essential ESB Introduction

Edge-Raggedness Evaluation Using Slanted-Edge Analysis

Supplementary Information for. Surface Waves. Angelo Angelini, Elsie Barakat, Peter Munzert, Luca Boarino, Natascia De Leo,

Determination and Correction of Optical Distortion in Cryogenic Target Characterization

Outline Remote Sensing Defined Resolution Electromagnetic Energy (EMR) Types Interpretation Applications

Nanonics Systems are the Only SPMs that Allow for On-line Integration with Standard MicroRaman Geometries

Fastest high definition Raman imaging. Fastest Laser Raman Microscope RAMAN

Light Guide Overview

Outline Remote Sensing Defined Resolution Electromagnetic Energy (EMR) Types Interpretation Applications 2

Peel Adhesion of Pressure Sensitive Tape

CARDING OF MICROFIBERS. Yoon J. Hwang, William Oxenham and Abdelfattah M. Seyam Nonwovens Cooperative Research Center North Carolina State University

Automated measurement of cylinder volume by vision

Bringing Answers to the Surface

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

PIV Measurements of Flow immediately above Woven Fabrics

MOXTEK S NEW ULTRA-LITE X-RAY SOURCES: PERFORMACE CHARACTERIZATIONS

Laser Beam Analysis Using Image Processing

METHOD FOR CALIBRATING THE IMAGE FROM A MIXEL CAMERA BASED SOLELY ON THE ACQUIRED HYPERSPECTRAL DATA

Fast Laser Raman Microscope RAMAN

ESA400 Electrochemical Signal Analyzer

Lectureo5 FIBRE OPTICS. Unit-03

ME 6406 MACHINE VISION. Georgia Institute of Technology

Transcription:

OpTiSurf - A New Optical Imaging Method for Measuring Surface Roughness of Tissue, Paper and Board Roland J. Trepanier, Ph.D. OpTest Equipment Inc. Hawkesbury, ON, Canada, K6A 3S3 ABSTRACT Australian Paper, Amcor R&D and OpTest Equipment Inc. have developed a new optical imaging method that measures the roughness of tissue, paper and board. The method provides valuable information about the spatial variation of surface non-uniformity. It can be applied to a wide range of paper types, including grades too difficult to measure by traditional air-leak methods such as porous sheets, soft sheets, tissue papers, specialty papers with laid lines or other imposed structure in the surface of the paper. INTRODUCTION Print quality is subjective and depends largely on the intended end use of the paper. For example, graphic papers need to be smooth, but the degree of smoothness required depends on the printing method that will be used. Lithographic offset printing, which transfers ink using a rubber blanket, is somewhat less demanding than gravure printing which uses a hard printing form to transfer ink to the paper surface. Similarly, methods used to measure smoothness or roughness may be more applicable to certain products. A number of methods and instruments are available for the measurement of surface roughness or smoothness. Such instruments can be broadly classified as Air Leak, Stylus or Optical. Instruments that rely on air leakage, between the paper sample and a reference plane to determine the unevenness of the paper have been around for over 70 years. They include smoothness testers, Bekk [1] (result reported in seconds, s) and roughness testers, Bendsten [2] (reports air leak in ml/min), Sheffield (reports Sheffield units in cm 3 /min) and Parker Print Surf [3] (reports µm). Traditional air leak methods are fairly quick and robust, but they are indirect and only report a single number to characterize paper roughness or smoothness. Stylus or direct profiling methods, using a mechanical stylus to physically measure the changing surface of the paper. Both stylus and air leak methods are slow and require contact with the paper, they inherently compress the sample and as such are somewhat destructive. Optical methods offer an alternative approach, they are non-contacting, faster and offer the possibility of examining the topography of the paper at a range of scales simultaneously. Various optical techniques have been proposed in the past, including reflection of polarised light, reflection of shallow incidence light and frustrated internal reflection of a glass surface pressed against the paper. Optical methods however have the potential to produce a vast amount of data that needs to be analysed and presented in a manner that relates to the underlying paper structure and the printing process. The method discussed in this paper is based on the concept of illuminating a paper sample at shallow incidence and analyzing the shadows cast by the surface topography to provide statistical information about surface roughness [4]. The results are presented as indices that correlate well with air leak methods [4,5]. Spectral information that relates to variations at different sizes has been shown to correlate well with formation [5]. The spectral size of roughness is important as an average roughness index only provides limited information [5,6]. TECHNOLOGY The technology is incorporated in an instrument called OpTiSurf. It is based on the concept of illuminating a paper sample at shallow incidence and using a digital camera to observe the shadows cast by the surface topography. The variation in reflected light intensity is analysed to provide statistical information about surface roughness. The instrument has been designed to accept samples ranging from cut sheets of 80mm wide to a 300mm wide continuous sheet (deckle strip or small reel). Operation A sample of paper is fed into the instrument, the sample is held by the nip between the top roller and the feed drum, and by guides around the edge of the feed drum, figure 1. C Figure 1: Schematic of operation. The sample is under slight tension to hold it securely in place against the feed drum. The paper is illuminated over a range of angles from New Applied Technology Conference, Asian Paper 2008, Bangkok 1

near normal to grazing incidence, by light emitting diodes (LEDs). This creates a pattern on the surface caused by highlighting hills and shadowing valleys. An image, figure 2, is captured by the digital camera, which is positioned normal to the illuminated surface, the image is then analysed statistically [4]. The sensitivity of the measurement is affected by the location of the measured area of the sample relative to the camera centre line, marked C on figure 1. The reflected light is more sensitive to small variations in the surface topography at C as the angle of illumination is just above grazing incidence. Consequently the slightest change in surface can cause a significant shadow to be cast (analogous to long shadows being cast at sunset). As the region that is being observed gets further above the centre line, C, the angle of illumination becomes more normal to the local plane of the surface and the shadowing becomes less pronounced (small shadows cast at noon) and the measurements are then less sensitive to the surface topography. Figure 2: Image of the surface of a sheet of linerboard. Image area is approximately 80mm x 60mm. DATA ANALYSIS The image acquired by the camera is stored as a two-dimensional array of pixel intensities. Along each array, row and column, there is a slowly varying component of intensity caused by the illumination geometry, as well as higher frequency components caused by roughness. The slowly varying component is removed [4,7]. The roughness indices are based on the standard deviation or RMS variation. The RMS variation in intensity is first calculated as image where the variation caused by topographic shadowing is highest. Averaging the row and column indices gives an overall index, referred to as the Optical Roughness Index (ORI). The ORI gives a simple descriptor of paper roughness, which can be compared to roughness measured by traditional air-leak techniques. However, considerably more information can be obtained by treating the pixel data differently. For example, Fourier transforms give intensity spectrum information in the sheet feed direction. Depending of the direction of feed either the MD or CMD spectrum is obtained. FFT Intensity spectrum analysis gives information about roughness on different length scales. The instrument offers a field of view of 8cm by 6cm with an optical resolution of 125µm. This resolution allows for example, the isolation of roughness caused by wire-marks; or, permits the study of fine-scale roughness on a sample that has texture embossed on it. COMPARISON WITH LASER PROFILOMETER The laser profilometery measurements, on a selection of 8 paper sheets, were made using the calibrated AltiSurf profilometer at Paprican. For each sheet 2 areas were measured on the same side. Each measured area was 64 mm MD X 80 mm CD. Measurements were made at a resolution of 1 µm in both directions with a spacing of 10 µm in the MD and 125 µm in the CD. To measure the 2 areas on a single sheet took at least 12 hours. Paprican applied a 2 nd order polynomial to the remove the large-scale variations from the raw data. The resulting detrended data was used to calculate the 1-d RMS (µm), in the MD, for each area tested. The average of the 2 areas was then used to compare with the ORI results, figure 3. x RMS =[ (1/N) Σ x i 2 ] 1/2 where x i represents the difference between the intensity value of each pixel, i, and the average corrected intensity for a particular array. The individual array RMS values are weighted and then averaged to give an average roughness index. Weighting the data tends to concentrate the measurement to the central region of the Figure 3: Comparison of the ORI (RMS-GL) with a calibrated laser profilmeter (RMS-µm) The 8 sheets were measured on 4 different OpTiSurf instruments and ORI calculated (RMS- New Applied Technology Conference, Asian Paper 2008, Bangkok 2

GL). Two measurements per sheet took less than 5 seconds. Figure 3 reveals that the optical roughness reported as ORI and AltiSurf roughness RMS (µm) is significantly correlated to a high level of confidence. This implies that the ORI can be calibrated to RMS (µm). COMPARISON WITH AIR LEAK MEASUREMENTS OVER A WIDE RANGE OF PAPER GRADES It is important to ensure that optical techniques, in addition to providing spectral or size data, can also provide roughness indices that correlate to existing air leak methods. Bonham et al [4] showed a non-linear correlation in excess of 90% between the ORI and Parker Print Surf and Bendsten results. This correlation was based on 240 samples ranging from coated photo quality inkjet to sack kraft papers. The Parker Print-Surf and Bendsten methods are industry standards, both based on measuring the rate at which pressurized air leaks under a circular land placed on the paper surface. Both these instruments however have limitations on the smoothness and weight of samples that can be measured, neither of which is a restriction for OpTiSurf. An advantage of the optical technique is that it is easy to use. In addition to roughness indices, Fourier transforms spectra are obtained ove a size scale from 0.25 mm to 32 mm. The same paper samples used by Bonham et al [4] were measured on the OpTiSurf and the 2-d FFT power spectra determined. The area under the power spectrum curve was calculated over the entire frequency range to produce a total power spectrum intensity for each sample [5]. As such, a higher value relates to rougher paper. Figure 4 shows a plot of the Parker Print Surf and Bendsten results plotted against the total power spectra intensities. It shows an exponential correlation of 85% and 79% respectively with the PPS and the Bendsten. The non-linear relationships between the air-leak roughness and the optical imaging roughness methods are evident if Figure 4. This nonlinearity limits the range of different grades that can be measured by each air-leak method and complicates attempts to compare different air-leak technologies. APPLICATION ON TISSUE PAPERS Sanitary tissue papers cannot be measured using common air-leak roughness methods. These grades are too porous and/or compressible. A 1- ply tissue typically has a grammage below 15 g/m 2 and lacks the stiffness to be fed into the apparatus while being held snugly against the backing cylinder, figure 1. A method was devised where the tissue was mounted on a flexible flat backing sheet with a slight in-plane tension. The mounted tissue and was then inserted into the OpTiSurf for analysis. Facial Tissue Softness A Canadian tissue manufacturer provided three sets of 2-ply facial tissue. A panel of judges at the manufacturer had ranked these as soft, acceptable and roughest. There is an expectation that surface roughness is one of the attributes that impacts softness. The sheets were separated in to single plies and the top ply mounted for testing. The MD direction of the tissue was tested as to ensure that the crepe was included in the analysis. Figure 5 reveals that the ORI increased as the panel ranking indicated that sheet was less soft. ORI (um) 25 23 21 19 17 15 13 11 9 7 5 Softest Roughest Panel Ranking Figure 5: Facial tissue 1-ply ORI roughness in comparison with panel assessment of 2-ply softness Figure 4. Correlation between PPS and Bendsten with optical roughness power spectra intensities [5] The OpTiSurf also provided FFT Intensity Spectra data in the form of 7 optical Roughness Intensity components. These are plotted in figure 6. However, it is the Relative Roughness that is most interesting to study, figure 7. New Applied Technology Conference, Asian Paper 2008, Bangkok 3

1400.00 1300.00 1200.00 1100.00 900.00 Roughness Intensity Softest Roughest The intensity of the embossing may vary from the inner layers of the bathroom tissue (BRT) roll, near the, to the outer layers. Also, the embossing quality may vary from roll to roll, fig 8. 800.00 700.00 600.00 400.00 Figure 6: The Roughness Intensity spectra from 0.25 to 32 mm 1.70 1.50 1.30 1.10 0.90 0.70 Relative Roughness Softest Roughest Figure 8: BRT embossing on the left, unacceptable on the right side. Two sets commercial BRT rolls were provided. Each set contained 4 BRT rolls. One set had acceptable embossing whilst the other did not. From each roll a sheet was sampled at: 3 layers from the, ¼ from the, ¾ from the and 3 layers from the outer layer. The sheet were mounted and measured both in the MD and CD. Figure 9 reveals that the ORI, and thus the embossing intensity, diminishes when going from the BRT to the outer ply. Also the ORI was greater for the acceptable samples (triangle identifiers in figure 9) compared to the unacceptable samples. 0.50 Figure 7: Similar results as figure 6, except the sheet is used as a reference sample Figure 7 demonstrates how the roughness of the softest and roughest sample, relative to the acceptable sheet changes depending the size of the roughness component. At about 12 mm, corresponding to OpTiSurf component R6, the ranking is comparable to the panel ranking of softness. This may indicated that the judges of the softness panel are sensitive to the roughness at a 8 mm to 16 mm scale. Bathroom Tissue Embossing A bathroom tissue manufacturer required a quantifiable way of determining the variation of embossing intensity. It was anticipated that the relative roughness would serve as a measurable indicator of embossing intensity. Figure 9: ORI results for acceptable (Sample-A) and Unacceptable (Sample-U) samples at different BRT roll diameters. The MD and CD Roughness Intensity spectra, figures 10 and 11, reveal the greatest difference between the acceptable and unacceptable embossing intensity occurred at the R4 size component (2 4mm) and likely corresponds to the embossing dimensions shown in fig. 8. New Applied Technology Conference, Asian Paper 2008, Bangkok 4

4000.00 3 3000.00 2 2000.00 1 Roghness Intensity Unacceptable 0.00 Figure 10: The MD Roughness (embossing) Intensity spectra from 0.25 to 32 mm for BRT samples taken 3 layers from the 5000.00 4 4000.00 3 3000.00 2 2000.00 1 Roghness Intensity Unacceptable 0.00 Figure 11: The CD Roughness (embossing) Intensity spectra from 0.25 to 32 mm for BRT samples taken 3 layers from the The Relative Roughness intensities at size component R4 were calculated at each BRT roll diameter position, figure 12. The sample was used as the reference sheet. A value less than 1 indicates that the test sheet has a lower roughness (embossing) intensity relative to the reference sheet. 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 Relative Roughness U/A 3rd ply from outside Component R4 (2-4 mm) 3/4" from 1/4" from MD CD 3rd ply from Figure 12: The R4 (2-4 mm) Relative Roughness Intensity of BRT samples from 4 roll diameter locations. Figure 12 shows that, on average, the R4 MD relative embossing intensity was about 60% of the acceptable level and that the CD relative embossing intensity was about 45% of the acceptable level. This approach provides a bathroom tissue manufacture with a quantitative method of monitoring embossing intensity. CONCLUSION This paper has presented a new optical method for the measurement of paper and tissue roughness. It explains the advantages of optical measurement over air leak methods and demonstrates high correlation of optical roughness indices with laser profilometry and air leak methods. This paper also demonstrates the importance of providing spectral information of optical roughness. It explains how this is achieved with OpTiSurf and presents data to explain the correlation of these measurements with other variables that affect paper quality. A wider range of grades may be measured by the optical roughness technique described above. Applications for facial tissue softness and bathroom tissue embossing were given in this paper. REFERENCES [1] Bekk, J., Apparatus for measuring smoothness and porosity, Paper Trade J. 94 (26):41 (1932) [2] Bendsten, C., Svensk Papperstidn. 42 (7): 195 (1939) [3] Parker, J.R., An Air Leak Instrument To Measure Printing Roughness of Paper and Board, Paper Technology 6 (2): 126 (1965). [4] BONHAM, J.S., REICH M, FALTAS, R A New Technique For Measuring Roughness APPITA 59 th Annual Conference & Exhibition, Auckland, N Zealand, May 16-19, 2005. [5] KW Corscadden, M Reich, R Faltas OpTiSurf An New Optical Method For Measuring Surface Roughness, PAPTAC 92nd Annual Meeting 2006, Pg A233, Montreal, Canada, Feb. 6-10, 2006. [6] Papermaking Science and Technology Series, Book 17 Pulp and Paper Testing, Chapter 9, TAPPI Press, 1999 [7] Fox, L. and Parker I. Chebyshev Polynomials In Numerical Analysis, Oxford University Press, (1968) New Applied Technology Conference, Asian Paper 2008, Bangkok 5