Application of Second Generation Wavelet Transform for SEIG Load Transient Detection

Similar documents
STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

Study on Voltage Controller of Self-Excited Induction Generator Using Controlled Shunt Capacitor, SVC Magnetic Energy Recovery Switch

Analysis of Single Phase Self-Excited Induction Generator with One Winding for obtaining Constant Output Voltage

A Novel Voltage and Frequency Control Scheme for a Wind Turbine Driven Isolated Asynchronous Generator

Power Quality Enhancement Using VSI Based STATCOM for SEIG Feeding Non Linear Loads

Modeling and Simulation of STATCOM

Transient Analysis of Self-Excited Induction Generator with Electronic Load Controller (ELC) for Single-Phase Loading

Eyenubo, O. J. & Otuagoma, S. O.

Chhattisgarh Swami Vivekanand Technical University, Bhilai

DESIGN OF A MODE DECOUPLING FOR VOLTAGE CONTROL OF WIND-DRIVEN IG SYSTEM

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

ADVANCED DC-DC CONVERTER CONTROLLED SPEED REGULATION OF INDUCTION MOTOR USING PI CONTROLLER

Space Vector Modulated Voltage Source Converter for Stand Alone Wind Energy Conversion System

Power quality improvement of self- excited induction generator using Multipulse AC-DC converters - A comparison

Self-Excitation and Voltage Control of an Induction Generator in an Independent Wind Energy Conversion System

Stability of Voltage using Different Control strategies In Isolated Self Excited Induction Generator for Variable Speed Applications

TABLE OF CONTENTS CHAPTER NO. TITLE PAGE NO. LIST OF TABLES LIST OF FIGURES LIST OF SYMBOLS AND ABBREVIATIONS

SEIG based Facts Device for the Three phase Non-Linear Loads

ABSTRACT I. INTRODUCTION

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

dr lr dt dt. V = ωl i g m m

CHAPTER-III MODELING AND IMPLEMENTATION OF PMBLDC MOTOR DRIVE

CHAPTER 3 WAVELET TRANSFORM BASED CONTROLLER FOR INDUCTION MOTOR DRIVES

CURRENT FOLLOWER APPROACH BASED PI AND FUZZY LOGIC CONTROLLERS FOR BLDC MOTOR DRIVE SYSTEM FED FROM CUK CONVERTER

CHAPTER 6 ANALYSIS OF THREE PHASE HYBRID SCHEME WITH VIENNA RECTIFIER USING PV ARRAY AND WIND DRIVEN INDUCTION GENERATORS

Design and Development of MPPT for Wind Electrical Power System under Variable Speed Generation Using Fuzzy Logic

CHAPTER 3 COMBINED MULTIPULSE MULTILEVEL INVERTER BASED STATCOM

Pid Plus Fuzzy Logic Controller Based Electronic Load Controller For Self Exited Induction Generator.

factors that can be affecting the performance of a electrical power transmission system. Main problems which cause instability to a power system is vo

Active damping of output LC filter resonance for vector controlled VSI- fed AC motor drive

SIMULATION OF D-Q CONTROL SYSTEM FOR A UNIFIED POWER FLOW CONTROLLER

Induction motor control by vector control method.

POWER ELECTRONICS. Converters, Applications, and Design. NED MOHAN Department of Electrical Engineering University of Minnesota Minneapolis, Minnesota

Vector control of AC Motor Drive for Active Damping of Output using Passive filter Resonance

UNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

Voltage Sags in Distribution Systems with Induction Motor Loads Fed by Power Converters and Voltage Mitigation using DVR and D-STATCOM

A VARIABLE SPEED PFC CONVERTER FOR BRUSHLESS SRM DRIVE

DESIGN OF A VOLTAGE-CONTROLLED PFC CUK CONVERTER-BASED PMBLDCM DRIVE for FAN

Power Quality enhancement of a distribution line with DSTATCOM

A NEW C-DUMP CONVERTER WITH POWER FACTOR CORRECTION FEATURE FOR BLDC DRIVE

Electronic Load Controller for Self Exited Induction Generator Using Fuzzy Logic Controller

A New Control Strategy for Three- Phase Inverter Applied To Induction Motor of Micro Grid

A Novel Topology for Three-Phase SEIG Feeding Single-Phase Loads by using STATCOM Based Controller

MECH 1100 Quiz 4 Practice

Compensation and Harmonic Elimination of Unbalance Currents in SEIG Based Statcom

Renewable Energy Based Interleaved Boost Converter

Simulation Analysis of Three Phase & Line to Ground Fault of Induction Motor Using FFT

Analysis of Indirect Temperature-Rise Tests of Induction Machines Using Time Stepping Finite Element Method

Voltage Control of Variable Speed Induction Generator Using PWM Converter

ANFIS based 48-Pulse STATCOM Controller for Enhancement of Power System Stability

Synchronous Current Control of Three phase Induction motor by CEMF compensation

BLDC Motor Speed Control and PFC Using Isolated Zeta Converter

GRID CONNECTED HYBRID SYSTEM WITH SEPIC CONVERTER AND INVERTER FOR POWER QUALITY COMPENSATION

Digital Control of Permanent Magnet Synchronous Motor

SINGLE PHASE BRIDGELESS PFC FOR PI CONTROLLED THREE PHASE INDUCTION MOTOR DRIVE

Volume I Issue VI 2012 September-2012 ISSN

Brushless DC Motor Drive using Modified Converter with Minimum Current Algorithm

Performance Analysis of Switched Capacitor Three Phase Symmetrical Inverter Topology with Induction Drive

CONVERTERS IN POWER VOLTAGE-SOURCED SYSTEMS. Modeling, Control, and Applications IEEE UNIVERSITATSBIBLIOTHEK HANNOVER. Amirnaser Yazdani.

Dynamic Response of Wound Rotor Induction Generator for. Wind Energy Application

A Switched Boost Inverter Fed Three Phase Induction Motor Drive

Simulation of Advanced ELC with Synchronous Generator for Micro Hydropower

CHAPTER 1 INTRODUCTION

Performance Enhancement of Sensorless Control of Z-Source Inverter Fed BLDC Motor

Comparative Analysis of Space Vector Pulse-Width Modulation and Third Harmonic Injected Modulation on Industrial Drives.

Feed-Forward System Control for Solid- State Transformer in DFIG

Steady State Operation of Self-Excited Induction Generator with Varying Wind Speeds

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

Medium Voltage DC Testbed: Generator System GS-1

Mitigating Voltage Sag Using Dynamic Voltage Restorer

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

Overview of Wind Turbine Driven Self-Excited Induction Generator

Three-Phase to Five-Phase Transformation Using a Special Transformer Connection

A Static Synchronous Compensator for Reactive Power Compensation under Distorted Mains Voltage Conditions

A SPWM CONTROLLED THREE-PHASE UPS FOR NONLINEAR LOADS

CONTROL SCHEME OF STAND-ALONE WIND POWER SUPPLY SYSTEM WITH BATTERY ENERGY STORAGE SYSTEM

Development of an Experimental Rig for Doubly-Fed Induction Generator based Wind Turbine

Study of Harmonics and THD of Nine Phase PWM Inverter Drive with CLC Filter for motor drive applications

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

Pak. J. Biotechnol. Vol. 13 (special issue on Innovations in information Embedded and communication Systems) Pp (2016)

Modeling and Simulation of Induction Motor Drive with Space Vector Control

Comparative Analysis of Multiple-pulse VSC-Based STATCOM s for Voltage-Dip Mitigation

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

MPPT for PMSG Based Standalone Wind Energy Conversion System (WECS)

A REVIEW ON THREE-PHASE TO SEVEN-PHASE POWER CONVERTER USING TRANSFORMER

Improved Transient Compensation Using PI-SRF Control Scheme Based UHVDC For Offshore Wind Power Plant

Enhanced Power Quality in Parallel Operation of Hydro Power Generation Using Isolated Asynchronous Generators

Speed control of power factor corrected converter fed BLDC motor

ANALYSIS OF POWER QUALITY IMPROVEMENT OF BLDC MOTOR DRIVE USING CUK CONVERTER OPERATING IN DISCONTINUOUS CONDUCTION MODE

SPEED CONTROL OF AN INDUCTION MOTOR USING FUZZY LOGIC AND PI CONTROLLER AND COMPARISON OF CONTROLLERS BASED ON SPEED

Modeling & Simulation of Permanent Magnet Synchronous Wind Generator Based Stand-alone System

IJESRT. (I2OR), Publication Impact Factor: (ISRA), Impact Factor: Student, SV University, Tirupati, India.

Improved Power Quality Bridgeless Isolated Cuk Converter Fed BLDC Motor Drive

IN MANY industrial applications, ac machines are preferable

Analysis of Advanced Techniques to Eliminate Harmonics in AC Drives

B.Tech Academic Projects EEE (Simulation)

A Comparative Study between DPC and DPC-SVM Controllers Using dspace (DS1104)

IJCSIET--International Journal of Computer Science information and Engg., Technologies ISSN

A Robust Fuzzy Speed Control Applied to a Three-Phase Inverter Feeding a Three-Phase Induction Motor.

Transcription:

14 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES) 1 Application of Second Generation Wavelet Transform for SEIG Load Transient Detection Jyotirmayee Dalei and Kanungo Barada Mohanty Department of Electrical Engineering, National Institute of Technology Rourkela, Rourkela-769 8, India jyoti uce@yahoo.com kbmohanty@nitrkl.ac.in Abstract Self-excited induction generator (SEIG) is preferred in isolated and remote power generating systems. But the major problem associated with SEIG is change in voltage and frequency during loading condition. For the development of simple voltage and frequency controller it is essential to detect the load transient in less time using less hardware. In this paper Second Generation Wavelet Transform (SGWT) and Discrete Wavelet Transform (DWT) are used for SEIG to detect load transient. It is observed that SGWT is more powerful and capable than DWT. Its computation time to detect load transient is less and also requires less hardware in real time. Index Terms Self-excited induction generator; Transient detection; Discrete Wavelet Transform; Second Generation Wavelet Transform. NOMENCLATURE d Direct axis. q Quadrature axis. s Stator variables. r Rotor variables. l Leakage component. v Instantaneous voltage. i Instantaneous current. i m Magnetizing current. L m Magnetizing inductance. r Resistance. L Inductance. ω r Electrical rotor speed of SEIG. T drive Mechanical input torque of the SEIG. T e electromagnetic torque of the SEIG. J Moment of inertia P number of poles of SEIG. i ed Current through the excitation capacitor in d axis i eq Current through the excitation capacitor in q axis C ed Excitation capacitor values in d axis. C eq Excitation capacitor values in q axis. I. INTRODUCTION Due to increased pollutions and environmental impact of fossil fuels, non-conventional energy sources such as, wind, PV, bio-mass gas etc. are getting increased attention. Generation of electricity from wind is widely in use because low cost generation and abundance of availability. Squirrel cage induction machine is most suitable as compared with synchronous machine to extract electric power from wind especially in isolated and remote areas [1] because of its precise advantages such as low cost, simple brushless construction, requirement of less maintenance, ability to produce power from variable speed and self-protection from short circuits faults and over-load. A capacitor bank when connected with an externally driven squirrel cage induction machine is known as self-excited induction generator (SEIG). Though SEIG has advantages, the major drawback is voltage and frequency variation [] during loading condition. To control voltage of SEIG, use of static var compensator (SVC) consisting of a fixed capacitor and and thyristor controlled inductor is reported in [3] and [4]. But the problems with SVC are injection of harmonic caused by switching of line currents and large size of passive elements. Development of fast acting self-commutating switches such as insulated gate bipolar transistor (IGBT) and metal oxide semi conductor field effect transistor (MOSFET), made possible to control voltage and frequency of SEIG with pulse wih modulated (PWM) voltage source inverter (VSI) [5] - [7]. This type of reactive power compensator is basically known as static reactive power compensators (STATCOM). But this type of scheme involves complex electronic circuit and requires stator and load current sensors and PI controllers. In [8], technique having discrete wavelet transform (DWT) to detect load transients and particle swarm optimization (PSO) method to estimate capacitance value to maintain rated voltage are reported sensing stator current. Second generation wavelet transform (SGWT) is used in [9] for detecting power quality events and in [1] to extract Partial discharge pulse from electrical noise. In this paper DWT and SGWT, are used to detect load transients. II. SYSTEM DESCRIPTION Fig. 1 shows the schematic diagram of wavelet based module integration to the SEIG. The system consists of an induction machine with capacitor bank used as a self-excited induction generator (SEIG) driven by renewable energy based prime-mover, detection unit, VAR estimation unit, STATCOM and load. When load connects with SEIG voltage and frequency vary, so SEIG needs voltage and frequency controller for maintaining voltage and frequency of SEIG. A. Modeling of SEIG Stator and rotor equations of SEIG in stationary frame d q axis are derived as [11] i sd = 1 K [ωrl misq Lrrsisd + ωrlmlrirq + Lmrrird + Lrvsd] (1) i sq = 1 K [ Lsrsisq ωrl misd + Lmrrirq ωrlmlrird + Lrvsq] () 978-1-4799-6373-7/14/$31. 14 IEEE

1 i rd = 1 K [ωrlmlsisq + rslmi sd ω rl sl ri rq r rl si rd + L mv sd ] (3) L m ( H ).8.6 i rq = 1 K [rslmisq + ωrlmlsi sd L sr ri rq + ω rl sl ri rd L mv sq] (4).4.5 1 1.5.5 3 i ( A ) m where L s = L ls + L m and L r = L lr + L m and K = (L s L r L m). Magnetizing current i m is determined from i sd,i sq,i rd and i rq using expression i m = (i sd + i rd ) +(i sq + i rq) (5) The magnetization characteristic of the SEIG has a great role for achieving steady state voltage. Relation between magnetizing inductance L m and magnetizing current i m are obtained from synchronous speed test. Fifth-degree polynomial is taken in this paper and given as: L m = a 5i 5 m + a4i4 m + a3i3 m + ai m + a1im + a (6) where a 5, a 4,... and a are constants obtained through curve fitting of experimentally data and the characteristics is given in Figure. The value of these constants are given in appendix. The electromagnetic torque T e of SEIG is ( )( 3 P T e = The torque balance equation of the SEIG is B. Excitation modeling ) L m[i sqi rd i sd i rq] (7) ( ) dωr T drive = T e + J P The excitation system dynamics are introduced using d q components of stator voltage (v sd and v sq ) as state variables, given as Prime mover Sensed Voltage of SEIG Voltage Sensor Rated Voltage of SEIG SEIG dv sd dv sq Current sensor Transient detection unit VAR estimator (8) = i ed C ed (9) = ieq C eq (1) capacitor bank STATCOM PWM Generator Variable load Fig. 1: Schematic diagram of standalone SEIG system. Fig. : Graph of the measured (blue) and approximated (red) magnetizing inductances vrs magnetising current C. Modeling of static load The d and q axes current equations for the balanced resistive load can be derived as i ld = v sd R L (11) i lq = v sq R L (1) The d and q axes current equations for the balanced RL load are given as di ld di lq D. Wavelet based transient detection unit = v sd R Li ld L L (13) = vsq RLi ld L L (14) Stator current signals are captured and send to the wavelet based transient detection unit. Two techniques i) discrete wavelet transform (DWT) and ii) second generation wavelet transform (SGWT) are used in this paper. 1) DWT: DWT convert data from the time domain (the original signal) to the wavelet domain. It decomposes the original signal S[k] into approximation coefficients A 1 [k] and detail coefficient D 1 [k] at different frequency bands through low pass and high pass filters respectively using down sampling algorithm (by a factor of ) [1], this process is known as first level decomposition. In second level decomposition A 1 [k] is further fed to low pass and high pass filters and obtain approximation coefficient A [k] and detail D [k], this process continues up to n levels. Continuous Wavelet transform can be implemented both in continuous and discrete domain. Continuous wavelet can be defined as: CWT = 1 ( ) t j S(t)φ (15) i i where i is the scaling(dilation) factor and j is the translation (time shift) factor and φ is the mother wavelet. Sampled waveform implemented by DWT and expressed as DWT = 1 m ( ) k k. m S[k]φ k m (16) where k and m are integers and the parameters i and j are replaced by m and k m. Fig. 3 shows block diagram of DWT decomposition. DWT is convolution based hence computation time to detect transient and hardware requirements to implement in real time is more. These problems can be sort out through SGWT.

3 S[k] S[k] LP HP Odd/Even split A 1[k] D 1[k] X[k] Y[k] -P + LP HP + U A [k] D [k] C[k] D[k] Fig. 3: Block diagram. Discrete Wavelet Transform decomposition tree up to second level. Second Generation Wavelet Transform decomposition. ) SGWT: In SGWT, biorthogonal wavelets are constructed, [9] using lifting scheme (LS) and applied to detect power quality events. For constructing wavelets in SGWT, translation and dilation are not required as required in case of DWT. Convolution is not required in case of SGWT. SGWT is fully spatial domain interpretation transform [1], consists of three steps split, predict and update. Split: In this step the original signal S[k], divides into two disjoint subsets i.e. X[k] =S[k] even and Y [k] =S[k] odd, where X[k] and Y [k] are the even and odd index points of S[k] respectively and both are correlated. Predict: Detail coefficients, D[k] are determined using expression is given as: D[k] =Y [k] P (X[k]) (17) where P (X[k]) is the prediction of Y [k] based on X[k] and P is the prediction operator. Linear combination of Y [k] is P (X[k]. Update: Approximation coefficients, C[k] are determined using the expression is given as: C[k] =X[k] +U(D[k]) (18) where U is the update operator applied to details. The approximation further is fed through filter again and decomposed at a higher level as in the case of DWT. Fig. 3 shows the Block diagram of SGWT decomposition tree for first level only. E. VAR estimator unit When load connects with SEIG, transient detection unit sends signal to VAR estimator unit. VAR estimator unit activates and calculates exact amount of extra VAR needs using any optimization technique such as genetic algorithm or, particle swarm optimization technique, to meet the VAR demands by load connect to SEIG. However, it estimates the capacitance value requires providing VAR demands by load and compensation current [8] is computed as: I Compensation = V terminal X estimate X noload (19) Where V terminal is the terminal phase voltage of SEIG, X noload is the capacitive reactance value per phase connect with SEIG and X estimate is the estimated capacitive reactance value per phase required to meet the VAR demands required by load. III. RESULTS AND DISCUSSION A 3.7-kW, 415-V, 5-Hz, 4 pole delta connected induction machine has been taken for simulation and experiment. Parameters of the induction machine are determined from the standard dc resistance test, no-load test and blocked rotor tests and measured values are given in Appendix. Capacitor bank is connected with induction machine to operate as self excited induction generator. Fig. 4 and shows the voltage and current build process of SEIG during loading condition. Steady state rated voltage of 586.81 V (415 r. m. s.) is obtained for rated speed of 15 r. p. m with 1 μf capacitor connected across stator of SEIG. At t=1.1 s load is connected to SEIG and SEIG voltage and current starts to fall observed from the figure. When load is connected to SEIG, a transient case occurs. To detect this load switching DWT and SGWT are used. Fig. 5 is the captured SEIG current signal for a resistive load and Fig. 5 and (c) shows the obtained high frequency detail coefficients using DWT and SGWT. It is observed from the figure that load is connected to SEIG at t=1.1 s and computation time taken using DWT is.95 s and SGWT is.855 s. Fig. 6 is the captured stator current signal for a RL load and Fig. 6 and (c) shows the obtained high frequency detail coefficients using DWT and SGWT. It is observed from the figure that load is connected to SEIG at t=1.3 s. and computation time taken using DWT is.937 s and SGWT is.864 s. Voltage (V) 5 5..4.6.8 1 1. 1.4 1.6 1 5 5 1..4.6.8 1 1. 1.4 1.6 Fig. 4: Stator terminal voltage and current of SEIG during loading Voltage. Current.

4 1 1..4.6.8 1 1. 1.4 1.6 TABLE I: Computation time to detect Load switching using DWT and SGWT. CASE DWT SGWT I.95 s.855 s II.937 s.864 s III.113 s.91 s IV.114 s.95 s....4.6.8 1 1. 1.4 1.6.1.5.5.1..4.6.8 1 1. 1.4 1.6 Fig. 5: Stator current decomposition of SEIG for resistive load. Captured current signal. Using DWT. (c) Using SGWT. Fig. 7: Experimental setup of the dc motor coupled with induction machine used in the investigations. 1 1..4.6.8 1 1. 1.4 1.6.1.1..4.6.8 1 1. 1.4 1.6 1.8.1.1..4.6.8 1 (c) 1. 1.4 1.6 Fig. 6: Stator current decomposition of SEIG for RL load. Captured current signal. Using DWT. (c) Using SGWT. Table- I shows the computation time to detect load switching for four different cases using both DWT and SGWT. Fig. 7 shows the experimental setup of SEIG. Experimental results of voltage build-up of stator terminal voltage and stator current are shown in Fig. 8 at no load condition and Fig. 8 shows the SEIG stator voltage and load current during loading condition. Fig. 8: Experimental results. SEIG stator voltage at noload (top) and stator line current (bottom). Stator terminal voltage of SEIG during loading condition (top) and load current (bottom).

5 IV. CONCLUSIONS Self-excited induction generator is suitable in isolated and remote areas to produce electric power using renewable energy. But the problem is voltage and frequency of SEIG, vary when loads are switched to SEIG. For the development of simple voltage and frequency controller load transient detection is essential. In this paper two techniques, DWT and SGWT are employed to detect load transients. It is observed that computation time taken using SGWT is less compared to DWT. APPENDIX Parameters of SEIG: 3.7 kw, 415 V, 7.5 A (line), 5 Hz, 15 r/min, four poles, delta connected, R s =7.34 Ω, R r =5.64 Ω, X ls = 6.7 Ω, X lr = 6.7 Ω and J =.16 kg/m. The constants of the magnetization characteristics of SEIG are given as, a 5 =.38, a 4 =.576, a 3 =.34, a =.713, a 1 =.853 and a =1.43. REFERENCES [1] R. C. Bansal, T. S. Bhatti, and D. P. Kothari, A bibliographical survey on induction generators for application of non -conventional energy systems, IEEE Trans. Energy Convers., vol. 18, no. 3, pp. 433 439, Sept. 3. [] B. Singh, S. S. Murthy and R. S. Chilipi, STATCOM based controller for a three phase SEIG feding single phase loads, IEEE. Trans. Energy Convers., vol. 9, no., pp. 3 331, Jun. 14. [3] M. B. Brennen and A. Abbondanti Static exciters for induction generators, IEEE Trans. Ind. Appl., vol. 13, no. 5, pp. 4 48, Sept. 1977. [4] R. K. Mishra, Voltage regulator for an isolated self-excited cage induction generator, Electric Pow. System Research., vol. 4, pp. 75 83, 199. [5] S. C. Kuo and L. Wang, Analysis of voltage control for a self-excited induction generator using a current controlled voltage source inverter, IEE Proc. Generat., Transmiss. Distrib., vol. 148, no. 5, pp. 431 438, Sep. 1. [6] L. A. C. Lopes and R. G. Almedia, Wind driven self-excited induction generator with voltage and frequency regulated by a reduced rating voltage source inverter, IEEE Trans. Energy Convers., vol. 1, no., pp. 97 34, Jun. 6. [7] G. K. Kasal and B. Singh, Decoupled voltage and frequency controller for isolated asynchronous generators feeding three phase four wire loads, IEEE Trans. Power Del., vol. 3, no., pp. 966 973, Apr. 8. [8] X. Lu, K. L. V. Iyer, K. Mukherjee, A wavelet/pso based voltage regulation scheme and suitability analysis of copper and aluminum rotor induction machines for distributed wind power generation, IEEE Trans. on Smart Grid, vol. 3, no. 4, pp. 193 1934, Dec. 1. [9] A. S. Yilmaz, A. Subasi, M. Bayrak, V. M. Karsli and E. Ercelebi, Application of lifting based wavelet transforms to characterize power quality events, Energy Convers. Management, vol. 48, pp. 11 13, 7. [1] X. Song, C. Zhou, D. M. Hepburn, G. Zhang, Second generation wavelet transform for data denoising in PD measurement, IEEE Trans. on Dielectrics and Elect. Insulation, vol. 14, no. 6, pp. 1531 1537, Dec. 7. [11] P. C. Krause, Analysis of electric machinery, McGraw-Hill Book Co New York, 1987. [1] P. K. Ray, S. R. Mohanty and N. Kishor, Disturbance detection in grid connected distributed generation system using wavelet and S-transform, Electric Power System Research vol. 81, pp. 85 819, 11.