Radiodetection Pipeline Products

Similar documents
Pipeline Current Mapper

pipeline integrity PCM + Pipeline Current Mapper

PIPELINE DEFECT MAPPER

Precision Pipeline Locator System User Guide. Rev

CIPS, DCVG & GPCM Pipeline Surveyor. Corrosion Control Equipment

QLD/NT NSW WA

Static Stray DC Current Interference Testing

Leica Digicat i-series Safe and fast location of underground services

PCMx: faster pipeline surveying with simultaneous data gathering

DCVG Coating Survey Data Sheet

Smart Interrupter SI220 User Guide High performance, solid-state Current Interrupter for pipeline Cathodic Protection monitoring

Leica Digisystem i-series Safe and fast location of underground utilities

vloc Series 2 Smaller and lighter Over four times battery life Define, set and lock available features Customizable startup screen and much more...

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Specialists in Remote Monitoring

DCVG Training Manual DA Meter Version

Obsolete Document. Dynatel

Leica Digisystem Safe and fast location of underground services

RMU3 Remote Monitoring Unit and GPS Interrupter

DOCUMENT OBSOLETE. Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Specifications for 3M Dynatel 2273M/M-iD Cable/Pipe and Fault Locators

REMOTE MONITORING AND CONTROL SYSTEM

Nine LEDs provide feedback of transmitter operation. Induction selected One Red LED Frequency/Mode selection Four Green LEDs

SeCorrPhon AC 200. correlator and acoustic water leak detector combined professional flexible intelligent

I N N O V A T I N G U N D E R G R O U N D L O C A T I N G

Technical Seminar for Cathodic Protection to GOGC Design Unit Specialists. Dr. Nick Kioupis, Cathodic & Lightning Protection Section Head, DESFA

Surface Potential Surveys Training Manual DA Meter Version

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

Electronic Pipeline Technology Ltd

AUTOMATIC WEATHER AND HYDROLOGICAL STATIONS

Industrial Area Crossing Signal System

DCVG Training Manual G1 Version

AC Voltage- Pipeline Safety and Corrosion MEA 2015

Universal precision cable and pipe locator

StarTrak Pigging Technologies

UTILITY LOCATING EQUIPMENT

Operating Instructions for SymCom s INFORMER MS EDITION DIAGNOSTIC TOOL

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

SuperCAT 4+ Utility-specific range for finding CPS protected pipes, sondes, telecom and power cables

SEL Phase Comparison Faulted Circuit Indicator (PC FCI) Communicates to line crews using the. Features and Benefits

STARTRAK PIGGING TECHNOLOGIES, INC. PIPELINE PIG MONITORING

Advanced Test Equipment Rentals ATEC (2832)

OVERCOMING THE NEW THREAT TO PIPELINE INTEGRITY - AC CORROSION ASSESSMENT AND ITS MITIGATION -

cable and pipe locators RD Utility cable and pipe locator

Universal precision cable and pipe locator

MODEL PD PEARSON DETECTOR

Detection of Pipelines using Sub-Audio Magnetics (SAM)

Dynatel 2250E/2273E Advanced Cable and Fault Locator

Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions

MAGNETOMETER-BASED MEASUREMENTS OF STRAY CURRENT DISTRIBUTION ON CATHODICALLY PROTECTED GAS TRANSMISSION PIPELINE

IS7705. Installation & Operation Manual AUDIO INTEGRATION KIT. TranzIt LINK

PLA-240. Small Room Loop Amplifier System. USER Manual MAN 211A

AT-4000 Advanced Tracer User s Manual

Ariadna Instruments. Power cable identifier & LV live network phase and feeder identifier

Products. Locating DAMAGE PREVENTION

Architectural/Engineering Specification for a. Microwave Perimeter Intrusion Detection System

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

An Automated Rainfall Monitoring System

2011 / Circuit Tracer

Propagation of Electromagnetic Waves

Operation Manual for CTL-3000

vlocdm User Handbook (English Edition) Version 2.0

This manual applies to the WT-RC-Ex receiver when used to locate all makes and models of 22 Hz and Wavetrak coded transmitters.

vscan Data Sheet V1.0

Application Note. Detection of Partial Discharge Using Ultrasound. Detection of Partial Discharge Using Ultrasound. Problem. iriss.

Operators Manual For Spectrum Analyser SA97

PHASED OUT. DALI interface terminals are provided to allow control and monitoring via a seperate controller.

SPA WIRELESS SWITCHES AND RECEIVERS MANUAL

3050 Stereo Power Amplifier

PCMx. Pipeline Current Mapper system. User Guide 90/UG105INT/01

UAT-600 Series. amprobe.com

Electrical TP-18 February 2017 ELECTRICAL TECHNICAL PAPER 18 FREQUENTLY ASKED QUESTIONS ABOUT CATHODIC PROTECTION SYSTEM EQUIPMENT TESTING

Technical Information itemp TMT180

Aqua-Gen 3PV INSTRUCTIONS

PTE-50-CET. Three phase relay test set Current/Voltage

Two-Wire Programmable Transmitter for:

Aqua-Gen 3BR INSTRUCTIONS

Ring Pair Corrosion Monitor : RPCM

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver. Programming Videos

The CABLETROLL 3600 FCI is capable of discriminating between PTP and PTG faults, and indicating the direction of the latter type.

Nuclear Associates

32 CHANNEL SELECTABLE CH MHZ DOWN VOLUME

Rolyan Splint Pan OPERATION MANUAL. Item # Small Item # Large

Professional UHF Rechargeable Wireless Microphone System POWER ON/OFF BATTERY CHARGE. Green Light (Full) Better Music Builder DOWN VOLUME

C.A.T and Genny User Guide. Revision

High Performance, Application Specific Cable Avoidance

GEONICA, S.A. - Alejandro Rodríguez, nº Madrid - Spain Tel Fax

DUNHAM & MORROW By Schonstedt Instrument Company Tel: Fax:

Techno Instrumentation(India) Pvt. Ltd. Manufacturer of underground power cable fault locators

TOSHIBA International Corp

Dynatel Cable/Pipe and Fault Locator 2273M Cable/Pipe, Fault and Marker Locator 2273M-iD

Cathodic Protection & Monitoring

2 Interfacing. 2.1 Introduction. The C 411 III pickup is a condenser transducer and therefore needs a power supply. Important!

VZ-WFF. (Wireless Follow Focus) Instruction Manual

Two Wire Temperature Transmitter LTX-3000-H-2 LTX-3000-H LTX-3000-W LTX-3000-D

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS

Using Remote Data-Logging Techniques to Evaluate Transit System Interference

QDV120 Operation and Pointing manual

EM-7530 Meter, Magnetic Field Strength

vlocdm2 User Handbook

Transcription:

Radiodetection Pipeline Products For efficient troubleshooting of cathodic protection systems on buried pipelines The Pipeline Range

Pipeline Products Radiodetection is the world leader in the field of underground location and has developed a range of products for the pipeline and cable industry. Smart Interrupter (SI) SI The SI enables the interruption of CP current, an essential part of coating evaluation, during routine maintenance of coated, cathodically protected pipelines. In addition to the standard interrupter functionality, the SI can interrupt CP currents in a manner compatible with Radiodetection s Stray Current Mapper. The SI has high current capability available in 50A or 100A versions. Housed in a impact structural foam case, it is robust and compact in size. 50A and 100A units On/Off ranges between 0 to 100 seconds Reverse polarity protection 300 hours battery life, or can run continuously from CP supply Master/slave synchronization as standard Full microprocessor controlled Generates unique signatures for compatibility with Radiodetection's Stray Current Mapper and Precision Pipeline Locator The GPS option permits synchronization of any number of interrupters remote from each other, as well as permitting 24 hour timer operation Dealing easily with up to 1080 fibres

Stray Current Mapper (SCM) SCM SmartProbe The Stray Current Mapper (SCM) system is a safe and cost-effective method of undertaking stray current surveys on pipelines. These are caused by third party cathodic protection systems and D.C. electrified rail systems. Identify the source of stray current Locate discharge points Locate pick-up points Requires no connection to the pipeline SmartProbe for use in multiple pipes or very high interference sites Compatible with the Smart Interrupter The SCM can also completely map the distribution of any CP source. This means areas where current discharge is taking place (usually coating defects) can be accurately pinpointed. It is also capable of data logging for 48 hours. This can be post processed to identify areas of possible interference as well as identifying the source of the interference. Fully weatherproof housing Withstands 1m (3ft) drops onto concrete 48 hours data logging 48 hours battery life Compatible with a standard laptop computer Dedicated analysis software as standard With the help of 4 SI s, identifies source and magnetude of up to 4 sources simultaneously Locating Magnetometers The SCM can be used to: Pin-point a source of stray current interference Non-intrusively troubleshoot suspected areas of stray current interference Control software on laptop computer Smart Interrupter (SI) Lead Acid Battery Start/Stop Button Sensor Bar containing multiple Magnetometers

Pipeline Current Mapper (PCM) PCM PCM RECEIVER PCM TRANSMITTER Damaged coating of pipelines or shorts to other structures can render cathodic protection ineffective. Radiodetection s Pipeline Current Mapper has been specifically designed for surveying pipelines for these problems. The PCM overcomes the shortcomings of existing techniques and provides engineers with an accurate, cost effective product that can be used in all weather and ground conditions. PCM TRANSMITTER The PCM Transmitter is a high-powered unit which makes long range signal detection possible up to 20miles (32km). The flexible power requirements enable it to utilize the variety of supplies available at most transformer rectifier stations. This allows the transmitter to provide its full 150W of output power over prolonged periods, without costly battery replacements. Hookup is a simple four wire connection procedure. The transmitter is compatible with both distribution and transmission networks. Peak/Null The PCM Receiver is a hand-held unit which is used firstly to locate the pipeline and provides the operator with a measurement of depth, current magnitude and direction of the near d.c signal as applied by the system's transmitter. The receiver makes the required calculations and displays the results at a single button press. The measurement can be stored, with a further button press, in the integral datalog. This provides the operator with a method that quickly troubleshoots the CP system by pinpointing metallic contacts and locating areas of coating defects. Additional cable locate modes also allow the unit to be used as a traditional cable and pipe locator. Data Analysis - the PCM has a simple to operate windows based upload software package. PCM Accessory A-Frame Attachment - The addition of the optional A-Frame attachment enables the operator to pinpoint the fault to within a few inches. Withstands 0.5m drops onto concrete Weatherproof (with lid open) Operating modes: ELF, ELF with current direction, LF with current direction Complex signal containing multiple frequencies 150W output CP Transformer rectifier powered from station PCM RECEIVER High impact thermoplastic all weatherproof Withstands 1m (3ft) drops onto concrete Locating Modes: ELF, LF, 8K, Power and CPS Two section Liquid Crystal Display Data logging storage for upto 399 entries with log number, depth, current and direction Facility to review logged data On/Off Current Mode Shift Depth ac Mains input dc input Output Level Frequency Select Input Power Fuse Power Off Switch Ground Terminal Signal Output

Precision Pipeline Locator (PPL) Mis-location of services results in significant and costly damage to pipelines. Radiodetection has designed a system based on its advanced, very low frequency signal processing technology. This enables a buried pipe to be reliably located and identified from the surface, providing a depth of cover reading without the need to pot hole or penetrate the ground. Advanced digital signal processing techniques allow the system to compensate for interference, enabling it to be used in locations where previously it was not possible to use electronic locators. Where the interference is too great, the system will warn that the results are less accurate than normal. If this occurs more accurate information can be determined using the PPL SmartProbe. This is pushed into the ground until the tip is close to the pipe. The sensors in the probe which are now close to the pipe can reject any interference. The locator comprises a sensor array and associated digital signal processing electronics within a portable housing. The PPL receives the signal radiated from the pipe. Sophisticated vector analysis software will determine the position of the pipe, relative to the unit, and then transmit this information to the HDV (via a short range radio link). Handheld Data Viewer (HDV) The locator is compatible with Radiodetection s PCM Transmitter or Smart Interrupter which generate locate signals for the PPL Sensor Bar and SmartProbe. SmartProbe Smart Interrupter (SI) Pipeline Current Mapper (PCM) Precision Pipeline Locator (PPL)