9 PCB Relay High Capacity, Low Profile Relay Low profile:.7 mm max. in height Cadmium-free contacts ensuring environment-friendly use 0 kv impulse surge withstand Clearance and creepage distance: 0 mm/0 mm Tracking resistance: CTI>20 Choose from UL Class-B or Class-F insulation systems Low coil power of 00 mw UL, CSA and VDE approved VDE èò Ordering Information Classification Enclosure ratings Contact form SPST-NO SPDT DPST-NO DPDT Part number Class-B General-purpose Flux protection -A - -2A -2 Fully sealed -A - -2A -2 High-capacity Flux protection -A-E --E --- --- Fully sealed -A-E --E --- --- Class-F General-purpose Flux protection -A-CF --CF -2A-CF -2-CF Fully sealed -A-CF --CF -2A-CF -2-CF High-capacity Flux protection -A-E-CF --E-CF --- --- Fully sealed -A-E-CF --E-CF --- --- When ordering, add the rated coil voltage to the part number. Example: -A DC2 MODEL NUMBER LEGEND -PPP-P-P 2. Number of Poles : pole 2: 2 poles 2. Contact Form None: PPDT A: PPST-NO. Enclosure Ratings None: Flux protection (vented) : Fully sealed (with knock off vent nib ). Classification None: General purpose E: High capacity ( pole). Approved Standards None: UL, CSA, VDE, UL Class B Insulation CF: UL, CSA, VDE, UL Class F Insulation
Specifications COIL RATINGS Rated voltage VDC 2 VDC 2 VDC VDC Rated current 0.0 ma. ma.7 ma.9 ma Coil resistance 2. Ω 0 Ω,0 Ω, Ω Coil inductance ce (H) (ref. value) Must operate voltage Must release voltage Armature OFF 0..0.9.9 Armature ON 0. 2.7 9.72. 70% max. of the rated voltage 0% min. of the rated voltage Max. voltage 0% of the rated voltage (at C ) Power consumption Approx. 00 mw Approx. 0 mw CONTACT RATINGS Number of poles pole 2 poles Contact material AgSnO 2 AgNi Load Resistive load (cosφ=) Resistive load (cosφ=) Rated load 2 A ( A) at 20 VAC 2 A ( A) at 2 VDC A at 20 VAC A at 0 VDC Rated carry current 2 A ( A) A(70 C)/ A ( C) Max. operating voltage 0 VAC, 00 VDC Max. operating current 2 A ( A) A Max. switching power,000 VA (,000 VA), 2 W ( W) 2,000 VA, 20 W Values in parentheses are those for the high-capacity model. CHARACTERISTICS Item pole 2 poles Contact resistance Operate (set) time Release (reset) time 00 mω max. Approx. 7 ms Approx. 2 ms Max. operating frequency Mechanical:,000 operation/hr Electrical:,00 operation/hr at rated load Insulation resistance,000 MΩ min. (at 00 VDC) Dielectric strength Impulse withstand voltage,000 VAC, min between coil and contacts,000 VAC, min between contacts of same polarity 0 kv (.2'0 µs) between coil and contact Vibration resistance Destruction: 0 to Hz,.-mm double amplitude Malfunction: 0 to Hz,.-mm double amplitude Shock resistance Destruction:,000 m/s 2 Malfunction: Energized: 00 m/s 2 Not energized: 00 m/s 2 Life expectancy (Mechanical) 20,000,000 operations (at,000 operations/hr) Ambient temperature Operating: --0 C to C (withnoicing) Storage: --0 C to C (withnoicing) Ambient humidity % to % Weight Packaging Approx. 2 g Standard: 20 relays/stick,000 VAC, min between coil and contacts 2,00 VAC, min between contacts of different polarity,000 VAC, min between contacts of same polarity 2
APPROVED STANDARDS UL0 (File No. E)/CSA C22.2 (No.) (File No. LR92) Part number Contact form Coil ratings Contact ratings -A SPST-NO tovdc 2 A at 20 VAC (Generale use), 00k ops. - SPDT 2 A at 2 VDC (Resistive), 0k ops. -A-E SPST-NO (High capacity) A at 20 VAC (General use), 00k ops. A at 2 VDC (Resistive), 0k ops. --E SPDT (High capacity) 20 A at 20 VAC (General use), C A at 20 VAC (General use), 0 C -2A DPST-NO A at 277 VAC (Generale use), 00k ops. -2 DPDT A at 0 VDC (Resistive), 00k ops. VDE (VDE0) Part number Contact form Coil ratings Contact ratings pole, 2,, 22, 2, VDC 2 A at 20 VAC (cosφ=) 2 A at 2 VDC (L/R=0 ms) AC: A at 20 VAC DC: 2. A at 2 VDC, 0 ms pole (High capacity) A at 20 VAC (cosφ=) A at 2 VDC (L/R=0 ms) AC: A at 20 VAC (NO). A at 20 VAC (NC) DC: 2. A at 2 VDC (NO), 0 ms 2 poles A at 20 VAC (cosφ=) A at 2 VDC (L/R=0 ms) AC:. A at 20 VAC DC: 2 A at 0 VDC, 0 ms To achieve approved life cycles on sealed models, the relay should be vented by removing knock off vent nib on top of relay case after the soldering/washing process. Electrical Life Data Part number Contact rating Minimum operations --E A at 20 VAC (cosφ=) 00,000 operations min. ( sec. ON / 9 sec. OFF) A at 2 VDC 0,000 operations min. A at 20 VAC (cosφ=0.) 200,000 operations min. (N.O. side operation) A at 0 VDC (L/R=7 ms) 0,000 operations min. - 2 A at 20 VAC (cosφ=) 00,000 operations min. ( sec. ON / 9 sec. OFF) 2 A at 2 VDC 0,000 operations min. A at 20 VAC (cosφ=0.) 0,000 operations min. A at 0 VDC (L/R=7 ms) 20,000 operations min. -2 A at 20 VAC (cosφ=) 00,000 operations min. ( sec. ON / 9 sec. OFF) A at 0 VDC 0,000 operations min. -A-E Pilot duty (A00), 20 VAC 20,000 operations min. ( sec. ON / 9 sec OFF) Pilot duty (A00), 2 VAC 0,000 operations min. ( sec. ON / 9 sec OFF). The results shown reflect minimum cycles using a very severe duty cycle of sec ON/ sec OFF (unless otherwise specified above). 2. In order to obtain the full rated life cycles on the fully sealed models, the relay should be properly vented by removing the knock off vent nib on top of the relay case after the soldering / washing process of the P.C.B. Contact Omron for applications where venting of the sealed relay is not possible.
Engineering Data MAXIMUM SWITCHING CAPACITY -A, - -A-E, --E -2A, -2 Switching current (A) AC resistive load DC resistive load Switching current (A) AC resistive load DC resistive load Switching current (A) AC resistive load DC resistive load Switching voltage (V) Switching voltage (V) Switching voltage (V) AMBIENT TEMPERATURE VS RATED CARRY CURRENT AMBIENT TEMPERATURE VS MAXIMUM COIL VOLTAGE Rated carry current (A) -A-E, --E -A, - -2A, -2 Minimum coil voltage (%) Ambient Temperature ( C) Ambient Temperature ( C) The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Dimensions Unit: mm (inch) -A, -A Four,.±0. dia. (2.)
-, - Five,.±0. dia. 2 (2.) -A-E, -A-E Six,.±0. dia. (2.) --E, --E Eight,.±0. dia. 2 (2.) 7-2A, -2A Six,.±0. dia. (2.) -2, -2 Eight,.±0. dia. 2 (2.) 7
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 2.. 9 OMRON ELECTRONICS, INC. OneEastCommerceDrive Schaumburg, IL 07-00--OMRON OMRON CANADA, INC. Milner Avenue Scarborough, Ontario MB V -2- Cat. No. GC RLY7 0/00 Specifications subject to change without notice. Printed in U.S.A.