MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003

Similar documents
EIB/KNX Switch Actuators. User manual

User Manual. KNX MultiLight Dali. Article number: function Technology AS. Picture: KNX MultiLight products

User manual. KNX MultiController DALI. Article number: 5410x / 5411x. function Technology AS

Switch actuator. Movement detector Move/monitoring 1305/1.0, Art. No , ,

Time Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001

SeeTool - Solutions for KNX

K-BUS Switch Actuator

Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG DME DMB

KNX ENO 620/622 (32-channel AP)

For controlling 4 independent shutter or sunblind drives via ABB i-bus including the functions Up/Down, Step/Stop.

KNX manual 1-channel flush-mounted switch actuator SU 1

Rev ABB i-bus KNX 6151/11 U-500. Power and productivity for a better world TM

1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup.

Binary Inputs. Ref.-No. KNX universal binary input, 8-gang. ETS-product family: Series embodiment (SE-) device (2 units) Ref.-No.

RAM 712 KNX room thermostat for surface-mounted and flush-mounted installation

LED DALI CS Combination Sensor - User Manual

Product Manual. ABB i-bus EIB / KNX. Universal Interface US/U Intelligent Installation Systems

Technical data: Instabus EIB supply Voltage: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77

KNX presence detectors for ceiling flush mount EK-DD2-TP, EK-DE2-TP

Data sheet. Function description. Benefits

1. Use of the application program

Installer manual inputs/outputs interface for led KNX

KNX weather station basic V2

Width (W): 44 mm. bus connecting and branching terminal External supply --- Inputs: Number: up to 2 (depending on parameterization: channel 1 to 2)

Instruction manual. art Installation manual

Fan Coil Actuator FCA 2

Meteodata 140 S weather station

DALI CS. Datasheet. Combi Sensor Module. Sensor unit for automatic lighting control in DALI systems. Art. Nr (DALI CS Temp)

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

Fixture Built-in Sensor Daylight Harvest Version

User Manual 3X300 DIMMER MODULE DM03B02KNX

Unidirectional Gateway EnOcean - KNX/BUS

FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR

Technical Application Guide

ABB i-bus. KNX Weather Station WS/S Product Manual

Use of the application program. Functional description. GAMMA instabus Application program description. October 2007

Use of the application program. Functional description. GAMMA instabus Application program description. May A8 Venetian blind actuator

STC-KNX (32-channel AP)

Operating instructions II / 2004

OCC Motion Sensor. Guide: how to program and use

Technical manual GS 4x.00 knx application description air quality sensor

Light Control guide for Soundlight Comfort Ceiling OccuSwitch DALI Control Guide

KNX Room temperature controller

instabus EIB product documentation

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

TA-Slider 160 KNX R24 Protocol Implementation

DESCRIPTION & OPERATION: PIR OCCUPANCY SENSOR MSWSFSP221B-D FEATURES:

RF Wireless Version On/off Control

Technical Manual MDT LED-Indicator

series dimmer actuators, DMG 2 S, Upgrade Module DME 2 S and Booster DMB 2

KNX ON/OFF controller 4 contacts 16A

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2

Shutter Actuator with Manual Operation, 4-fold, 230 V AC, MDRC JA/S M, GH Q R0111. ABB i-bus EIB / KNX

Weather Station for KNX

EBDHS-MB-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

Sense Command Control. Third Eye. Energy Saving Sensors Save Energy Today for a Better Tomorrow

The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

TA-Slider 160 KNX Protocol Implementation

Use of the application program. Contents. instabus EIB Application program description. September S2 Room temperature controller

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE FOR FLEXIBLE MOUNTING

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

KNX ENO 634 (32-channel AP)

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE WITH BLUETOOTH

Installing the FSP-211 Sensor in Light Fixture

Wireless Ceiling Mount Sensor for Occupancy / Vacancy Detection INSTALLATION GUIDE

application software

EBDSPIR-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

Motion Sensors. Product Features. Applications

NOVA series Ceiling lights with tuneable white Colour temperature 2700 to 6500 K. Detailed operating instructions

KNX S-UP. Actuator for 230 V or 24 V. Installation and Adjustment

ActiLume 1-10V. OEM application guide

application software

MDT Switch Actuator/FanCoil

Sentido KNX Manual. Sentido KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium

Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators

EBDSM-PRM Product Guide

Human Centric Lighting System

Application Programs Descriptions

Rev Product Manual ABB i-bus KNX. Heating actuator 1gang with 6164/11 U-500. Power and productivity for a better world TM

This document is intended for Lighting Control Systems professionals

Thorsten Reibel, Training & Qualification Global Application and Solution Team

Current Module, 3-channel, MDRC SM/S , GH Q R0111

animeo KNX 4 AC Motor Controller 31. March 2016 WM/DRM V AC

EBDHS-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

OCCUPANCY SENSOR REMOTE USER GUIDE

The room thermostat application module with 2-fold switch sensor is placed on a flush-mounted bus coupler.

Application manual KNX room temperature controller EK-EP2-TP

Protection relays and transformers

Room thermostat solo, FM Type: 6124-xx

ZoneLite setup remote handset. Daylight Linking & Daylight Dependency control

SELECTABLE MODE HIGH/LOW/OFF PIR FIXTURE INTEGRATED INDOOR/OUTDOOR MOTION/PHOTO SENSOR

3000W multi Pir light controller

ABB i-bus KNX Valve Drive Actuator VAA/S x Product Manual

Radio motion detector comfort 1.1 m/2.2 m quicklink Order number

Technical Manual MDT Room Temperature Controller

Short operating instructions

Transcription:

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003 INSTRUCTIONS MANUAL Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com

General Description Indoor universal mechanism box mounted KNX motion detector. It incorporates as main function the Motion Detection. In addition it is possible to enable these functions: - Twilight switch - Constant light control - Signal monitoring - Light sensor - Temperature sensor These additional functions are independent, and can, or not, be enabled. Universal mechanism box mounted, with coverage of 200º and a maximum of 8m at 1,2-1,5m high. Possibility of adjusting the delay time so as Lux adjustment by the ETS or via potentiometers in the device itself. Technical Data Power supply Consumption Coverage (max.) Brightness sensor Time delay Commissioning Bus connection Colour Mounting Ambient temperature Type of protection Safety class According to the Standard Certification 21 ~ 32VDC (via Bus) < 20mA 200º, máx. 8m at 1,2-1,5m high 5 Lux ~ 1.000 Lux 0,1sec ~ 85 min ETS3 or ETS4 By the supplied KNX connecting terminal White Universal mechanism box mounted -10ºC ~ +45ºC IP20 (EN60529) III EN50090-2-2, EN50428 & EN50491 EIB/KNX Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 2

Project Development and Commissioning 1 General settings (General) Enable the functions that are going to be used. By default, all but the principal motion detection and remotely control are disabled. 1.1 Parameters Monitoring Function This function is similar to the main function "Motion Detection", with the addition that does not take into account the light level for triggering the detection. Furthermore, to consider the motion detection, the signal level received by the PIR, built into in the sensor, is taken into account in short periods of time. So it detects motion detections with high energy in short periods of time or low energy detected for long periods of time. Twilight Sensor This function allows managing the activity of an object depending on the daylight. Thus is activated when daylight is below a certain level and is deactivated when the light level is above a second level. As the levels of activation and deactivation can be different is possible to generate the necessary hysteresis to prevent cyclical turned on of the system. Constant Light Control This function allows managing the activity of an object depending on the daylight. This object marks the Lux level necessary to achieve a previously fixed threshold. This object must work with dimming actuators which can increase or decrease its value through the object "Dimming_Value". Temperature Sensor This function allows measuring the temperature at the sensor and sending this value to the bus. Brightness sensor This function allows measuring the level of light in the sensor and sending this value to the bus. Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 3

IR Remote Control Enable Enables or not the adjustment of certain parameters (Lux and Time) from an IR remote control. This parameter does not enable any communication object. 2 Basic settings of the Motion Detector (Settings) Sets the basic parameters of the motion detector. 2.1 Parameters Operation mode Allows selecting the desired operating mode: Normal: either the Lux Threshold as the Lag Time is set using the ETS or the adjustment knobs of the detector. From the ETS can be selected: o Threshold of light sensor adjustable via: ETS or Potentiometer o Threshold value in lux: 5lux ~ 1000lux o Lag time adjustable with: ETS or Potentiometer o Lag time: Time base of lag time x Time factor of lag time Standard: either the Lux Threshold as the Lag Time is set by default values: 5lux and 3min. Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 4

3 Movement sensor function 3.1 Parameters Activate object brightness depending switch Limits the dependence of the motion detector to the light level via a switch connected externally: Not available. Available: can be connected an external switch that enables this function. If the switch sends '1' Lux threshold is enabled, while if the switch sends '0', the detector will operate all the time, regardless of the daylight level. Activate object movement Enables or disables motion detection through a switch connected externally: Not available. Available: can be connected an external switch that enables this feature. If the switch sends '1' Lux threshold is enabled, while if the switch sends '0', the detector will work all the time. Enabling this option is possible to select if it will be enabled at receiving a telegram of ON or OFF: 'Enabling movement with'. Type of movement object Defines the type of object 'Telegram switch', which will be sent at detecting motion and when the lag time elapses: Switching (EIS1): it sends an object of a bit (0, 1). Can be selected if in case of detection ('Sending with detection') or at the end of the detection ('Telegram after lag time') is sent:: o ON telegram o OFF telegram o Cyclic ON telegram: ON is sent periodically. Time between two sending: Time Base for cyclic transmission x Time Factor for cyclic transmission. o Cyclic OFF telegram: OFF is sent periodically. Time between two sending: Time Base for cyclic transmission x Time Factor for cyclic transmission. o No telegram. Value (EIS6): it sends a value between 0 and 255. Can be selected if in case of detection ('Sending with detection') or at the end of the detection ('Telegram after lag time') is sent a value between 0% and 100%, in steps of 10%, or none telegram is sent. Sensibility (threshold) Allows making the sensor more or less sensitive to movements. A high sensitivity (1) makes it detects the slightest movement, while a low sensitivity (255) prevents unwanted false detections. Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 5

Behaviour on bus voltage recovery comm. object Brightness Switch enable Sets the 'Brightness dependent switching' object behaviour after a power failure of the Bus. After recovering the Bus, it can be enabled or not to consult the status of this object. Behaviour on bus voltage recovery comm. object Movement enable Sets the Movement Enable object behavior after a power failure of the Bus. After recovering the Bus, it can be enabled or not to consult the status of this object. 4 Monitoring function 4.1 Parameters Activate object monitoring enable Enable or disable this feature using an external device. Its functionality is linked to higher level systems, such as a Timer, which triggers the movement monitor certain hours. It is possible to select the trigger telegram ('Enabling monitoring function with'): ON Telegram OFF Telegram Behaviour on bus voltage recovery comm. object Monitoring enable Sets the 'Monitoring Activation' object behavior after a power failure of the Bus. After recovering the Bus, it can be enabled or not to consult the status of this object. Type of monitoring object Defines the 'Monitoring Telegram' object type, which will be sent both to detect motion, such as when elapses the time delay: Switching (EIS1): Sends an object of one bit (0, 1). Can be selected if at the beginning of the detection ('Sending at the beginning of detection') or at the end of the detection ('Sending at the end of detection') is sent: o ON Telegram o OFF Telegram o Cyclic ON Telegram: ON is sent periodically. The time between two sending: Time Base for cyclic transmission x Time Factor for cyclic transmission. Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 6

o Cyclic OFF Telegram: OFF is sent periodically. The time between two sending: Time Base for cyclic transmission x Time Factor for cyclic transmission. o No telegram: nothing is sent. Value (EIS6): It sends a value between 0 and 255. Can be selected if in case of detection ('Sending at the beginning of detection') or at the end ('Sending at the end of detection') is sent a value between 0% and 100%, in steps of 10%, or not sending any telegram. Sensibility (threshold) Allows making more or less sensitive to movements the detector. A high sensitivity (1) makes detecting the slightest movement, while a low sensitivity (255) prevents unwanted false detections. 5 Twilight Sensor 5.1 Parameters Activate object Twilight sensor Enable or disable this feature using an external device. Possible to select the trigger telegram ( Enabling Twilight sensor with ): ON Telegram OFF Telegram Behavior on bus voltage recovery comm. object Twilight sensor enable Sets the 'Twilight sensor enable' object behavior after a power failure of the Bus. After recovering the Bus can be enabled or not to consult the state of this object. Type of Twilight object Defines the type of object 'Twilight Telegram sensor', which will be sent reaching the maximum and minimum threshold light level: Switching (EIS1): sends an object of one bit (0, 1). Can be selected if in case of reaching the minimum threshold ('Sending at low Threshold') or the maximum threshold of lux ('Sending at high Threshold') is sent: o ON Telegram o OFF Telegram o Cyclic ON Telegram: ON is sent periodically. The time between two sending: Time Base for cyclic transmission x Time Factor for cyclic transmission. Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 7

o Cyclic OFF Telegram: OFF is sent periodically. The time between two sending: Time Base for cyclic transmission x Time Factor for cyclic transmission. o No telegram: nothing is sent. Value (EIS6): It sends a value between 0 and 255. Can be selected if in case of detection ('Sending at the beginning of detection') or at the end ('Sending at the end of detection') is sent a value between 0% and 100%, in steps of 10%, or not sending any telegram. High threshold LUX Sets the maximum lux level. Can be selected values between 15lux and 1000lux. Low threshold LUX Sets the minimum lux level. Can be selected values between 5lux and 500lux. 6 Constant light control 6.1 Parameters Activate object constant light control enable Enable or disable this feature using an external device. Possible to select the trigger telegram ('Enable function with'): ON Telegram OFF Telegram Behaviour on bus voltage recovery comm. object constant light control enable Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 8

Sets the 'Constant Light Control Enable' object behavior after a power failure of the Bus. After recovering the bus can be enabled or not to consult the state of this object. Origin of light sensor Is necessary to select if the light sensor is internal (built-in sensor) or external (a separate sensor): External: Enables the object 'External sensor value' in order to receive the value of an external light sensor. In addition, it must selected whether the set point is parameterized by the ETS ('Origin of Requested lux level = Via ETS parameter ) or via the communication object Lux Level Requested ('Origin of Requested lux level = Via communication object'). In case of choosing the parameterization by ETS, it must entered the value of lux to keep through 'Lux Level Requested' parameter. Can be set values between 100 lux and 1200 lux, in steps of 100. Built-in: four new parameters will be enabled in Advanced Settings (access to these settings only if really necessary): It is necessary to measure with a light meter in the sensor: o At night only with lamps (lux): lighting value measured in the sensor (ceiling) without daylight contribution and the lamps regulated to obtain the desired lighting in workplace. o At max. external light and lamps regulated to have requested level (lux): lighting value measured in the sensor (ceiling) to the maximum value of daylight and the lamps regulated to obtain the desired value of lighting in the workplace. The adjustment of the lamps is: o At night only with lamps (%): light level at which the lamps are regulated at night with only the lamps only. o At max. external light and lamps regulated to have requested level (%): level at which lamps are regulated with maximum daylight and lamps to the desired level. Constant light control Allows conditioning the constant light control to the motion detection or to a communication object: Only when movement detected: The dimming will become operational only when motion is detected. If people is not present, the system will send an OFF (or whatever programmed) through the Bus after the set time delay ('Lag time'). Always: the constant light control will operate every time, regardless of whether or not presence of people. The turning-on or turning-off of the lights can be made by a higher-level object. Depending object mode value: in case of selecting this option is enabled other communication object No. 10 'Permanent Constant light control', which allows to control remotely the system commissioning. Enable Object for manual dimming Allows enabling the dimming and manual switching from an external sensor (pushbutton, switch,...). Constant light object number Allows to control several lighting lines (up to 4) with an adjustable percentage of increase: 2nd constant light object attenuation. Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 9

7 Temperature sensor 7.1 Parameters Enable object temperature sensor Enable or disable this function using an external device. This value will be sent from time to time established by: Time base for cyclic transmission x Time factor for cyclic transmission. Behaviour on bus voltaje recovery comm. object Temperature sensor enable Sets the 'Temperature sensor enable' object behavior 'Temperature sensor enable' after a power failure of the Bus. After recovering the bus can be enabled or not to consult the state of this object. 8 Brightness sensor 8.1 Parameters This function simply allows getting the Lux value measured by the sensor. This value will be sent from time to time established by: Time base for cyclic transmission x Time factor for cyclic transmission. Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 10