Application and installation addendum - high power optical system

Similar documents
MP16 radio probe system

Installation guide M B. RSU10 USB interface

Retrofit desk assembly instructions

REE series digital interpolators

Installation and user s guide H A. NCi-5 non-contact tool setting interface

Renishaw fixtures Your single source for metrology fixturing

Laser scale axis referencing with controllers with low bandwidth sine and cosine inputs

CMM cable listings and pin out diagrams

RTLA50 absolute linear encoder scale system for EVOLUTE

RTLC20 high accuracy incremental linear scale

RTLA high accuracy absolute linear encoder scale system

RELA absolute high accuracy Invar scale

DSi dual readhead rotary encoder system

RELM20 high accuracy linear scale

RSLA absolute high accuracy stainless steel scale

Functional safety supplement L B. SiGNUM angle and linear analogue encoder systems

RGH34 encoder system. Data sheet L A. RGH34 readhead and RGI34 interface: RGS40 scale:

EVOLUTE absolute optical encoder with Yaskawa serial communications

rotary encoder system

RESOLUTE FS absolute optical encoder with Siemens DRIVE-CLiQ serial communications

Metal additive manufacturing for industrial applications. Global network of solutions centres. Applications expertise for a wide range of industries

RESOLUTE absolute optical encoder with Siemens DRIVE-CLiQ serial communications

RGH24 encoder system. Data sheet L C. RGH24 readhead: RGS20 scale:

absolute optical encoder for Panasonic serial communications

200, 201 Series Radio Telemetry Transmitters

RESOLUTE ETR (Extended Temperature Range) absolute encoder

User guide F A CARTO. Capture 3.0

Innovative frequency hopping radio transmission probe provides robust and flexible inspection on large machine tools

Modular Radio Telemetry System

QUANTiC series encoder system

Wall Mount Kit for Elo IDS-02 Series IDS Displays

SOLAR PANEL ACCESSORY. Solar Panel Mounting Bracket installation manual. Solar Panel Mounting Bracket

QUANTiC series encoder system

Modular Radio Telemetry System

RGH25F encoder system

EVOLUTE RTLA50-S absolute linear encoder system

RGH41 encoder system. The Renishaw RGH41 series is a non-contact optical encoder system, providing highly-reliable positional feedback.

RESOLUTE UHV absolute optical encoder

Warranty. RBS-T Linear Encoder Installation Manual and Owner s Guide

TONiC DOP (dual output) encoder system

Elo Touch Solutions Wallmounting Kit for the 7001L IDS Touchmonitors

SIR, RADAN and UtilityScan are registered trademarks of Geophysical Survey Systems, Inc..

2 Pipe Clamp Bracket 3 11 M6 Screw with Tube M6 Hex Nut 2 4 M20 Flat Washer 4

Guide To Returning Your Satellite Modem and Radio Assembly Model: HN9000

PS40/PS55/PS65. Installation Instructions. Articulated TV Wall Mount Range. Issue 002

Fulfill Retrofit Kit ProBlue Melters

DIGITAL AUDIO AMPLIFIER WITH BLUETOOTH. Model: DAA User Manual

FRL PRODUCTS Price List

User s Guide RF Shield. User s guide Version boosting wireless efficiency

AT Underground Cable/Pipe Locator System. Users Manual Mode d emploi Bedienungshandbuch Manuale d Uso Manual de uso Användarhandbok

VectaStar 3500 METHODS FOR SUCCESSFUL ANTENNA DEPLOYMENT

PICO-AMP Miniature Remote Sensing System

Y1160A EIA Rack Sliding Shelf Installation Note

Stainless Steel Bench Stand

MFJ-1835K34 40,30 METER ADD ON KIT FOR THE MFJ-1835 COBWEB ANTENNA INSTRUCTION MANUAL. CAUTION: Read All Instructions Before Operating Equipment

Wireless Pressure Station with Backlight

AN3218 Application note

18 Indoor/Outdoor Atomic Wall Clock

RGH22 encoder system. Data sheet L B. RGH22 readhead. RGS20 scale

PHYTER 100 Base-TX Reference Clock Jitter Tolerance

Signature Choral Riser Side Rail

80403NT11218A Rev

PRODUCT MANUAL. Flush Mount 1 mm Cavity TS FM01 K. Training and Technology for Injection Molding. Temperature Sensor

ORiNOCO AP-4000MR-LR and AP-4900MR-LR Access Points Safety and Regulatory Compliance Information

EBTRON a measurable difference!

Leksell Stereotactic System

Installation guide M A. RGH34 RGS40 linear encoder system

Frequently Asked Questions

SawStop. T-GlideTM. Fence System- Professional Series II OWNER S MANUAL

Service Manual for Installers Troubleshooting for Power-Line Communication SUNNY BOY 240-US / SUNNY MULTIGATE-US

Thank you for buying this AIS antenna splitter.

Installation guide H A (BETA SITE ONLY) RMI-Q radio machine interface

RFTX-1 Installation Manual

Model: WS-7014CH-IT Instruction Manual DC: WIRELESS FORECAST STATION

Agilent N2902A 9000 Series Oscilloscope Rack Mount Kit

Mill Operator Users Guide. Mike Cope Product Technical Specialist

CD42-STS Operating Manual Diver/ROV Pipeline Pig Location & Tracking System

Magnum low voltage drawout circuit breaker IEC horizontal stab cassette shutter kit (double wide A cassettes)

Experiment P-10 Ohm's Law

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

INSTALLATION INSTRUCTIONS Horizontal And Vertical Table Stands and Accessories Model: KTP-Series

MIRAGE BD-38-G DUAL BAND POWER AMPLIFIER

Double-Ridged Waveguide Horn Antennas

The PRC-2090 base docking station incorporates the PRC-2090 vehicle docking station plus an AC Power supply module P/N

Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions

SAN12 ( <00>)

CPH Coulter Tool Bar Brace Assembly

Dual-Band Wireless Adjustable Cellular Booster / Kit

SANnet II Family Rack Installation Guide for 2U Arrays

TABLE OF CONTENTS SECTION SECTION TITLE CONTENTS DESCRIPTION. Stamping 12/17/07

Watcheye S AIS Splitter. manual

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

Conductivity +/ 2% 1 or 2 point remotely through PLC or directly on board. Any two lead Conductivity probe (K 0.01, K 0.1, K 1.

Installation guide M B. VIONiC RSLM20 / RELM20 high accuracy linear encoder system

MSP-WRTIDSKY1 Light Weight Suspended Ceiling Kit for use with Island Display Skybox

TONiC DOP (dual output) encoder system

DOCUMENT OBSOLETE. Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Thuraya Orion IP Satellite Terminal. Maritime Installation Guide

Specifications for 3M Dynatel 2273M/M-iD Cable/Pipe and Fault Locators

Installation guide M D. VIONiC RSLM / RELM high accuracy linear encoder system

Transcription:

Addendum H-2000-4075-02-B Application and installation addendum - high power optical system Applicable to the following units: A-2107-0159 MP700E A-2085-0096 MP10E A-2033-7268 OMME A-2075-0323 MI 12E A-2075-0329 MI 12E (DIN-rail mount)

1999-2004 Renishaw plc. All rights reserved. Renishaw is a registered trademark of Renishaw plc. This document may not be copied or reproduced in whole or in part, or transferred to any other media or language, by any means, without the prior written permission of Renishaw. The publication of material within this document does not imply freedom from the patent rights of Renishaw plc. Disclaimer Considerable effort has been made to ensure that the contents of this document are free from inaccuracies and omissions. However, Renishaw makes no warranties with respect to the contents of this document and specifically disclaims any implied warranties. Renishaw reserves the right to make changes to this document and to the product described herein without obligation to notify any person of such changes. Trademarks All brand names and product names used in this document are trade names, service marks, trademarks, or registered trademarks of their respective owners. Renishaw part no: H-2000-4075-02-B Issued: December 1999 Revised: March 2004

Contents 1 Contents Introduction... 2 System components... 3 MP700E and MP10E...3 OMME... 3 MI 12E... 3 System configuration and installation... 4 Installation... 4 Cross-talk between adjacent systems... 5 Transmission and reception envelope... 6 Parts List... 8

2 Introduction Introduction This document describes the different system components, explains how they must be configured and installed, and the cautions to be observed to avoid interference and cross-talk. The high power optical transmission system is based upon standard optical systems, enhancements allow the system to transmit up to 12 m (39.3 ft) benefiting from reflections to maintain transmission. It enables the use of the MP700E and MP10E in applications requiring large probe and receiver separation. System comparison Operating range Turn-on range MP700E or MP10E and OMME 9.5 m (31.1 ft) 6 m (19.6 ft) MP700 or MP10 and OMM 6 m (19.6 ft) 3 m (9.8 ft) MP700 or MP10 and OM1 3 m (9.8 ft) 3 m (9.8 ft) For dimensional and system operation, please use in conjunction with: MP700 user guide - part no. H-2000-5132, MP10 user guide - part no. H-2000-5059, OMM user guide - part no. H-2000-5044, MI 12 user guide - part no. H-2000-5073

System components 3 System Components MP700E and MP10E Using an MP700E or MP10E gives an increased 360 operating envelope over MP700 or MP10. The MP700E and MP10E probes are available in a 70 version with extended optical lobe. OMME The OMME incorporates an auto-gain circuit which changes sensitivity according to the strength of the OMP signal. MI 12E Processes signals between the OMME and the CNC machine control.! CAUTION: For optimum system performance, the MI 12E should only be used with high power optical systems.

4 System configuration and installation System configuration and installation High power systems must include the OMME and MI 12E and for maximum range the MP10E or MP700E. For medium ranges, standard MP700 and MP10 could be used. A typical system will comprise of 2 x OMME, an MP10E / MP700E and MI 12E. Installation When installing a system, OMMEs should be placed so they are in line-of-sight with the MP10E/ MP700E during turn-on and for as much of the gauging cycle as possible. If reflections are to be relied on, ensure the total transmission distance is within the straight-line range. Often, surfaces do not have to look reflective to reflect well. When the best positions for the OMME have been found, temporarily mount the OMMEs and then move the probe to the extremities of travel, ensuring the signal strength of at least one OMME (at the MI 12E) is >1.5 volts and the turn on signal operates the MP10E / MP700E in the positions required. The OMME signal strength varies from 0.5 to 7 volts as the signal strength increases - the higher the signal the more robust the system against blind-spots and interference (use test points in MI 12E). On multi-axis machines, zeroing of MP700 may be necessary during the gauging cycle. To maximise turn-on range, ensure both OMMEs are pointing at the point/points in the gauging cycle that turn-on is required. If the OMME cable requires extending, it is recommended that a new screened cable with 16/0.2 conductors is used, connected close to the OMME. This can be up to 100 m long. Such a cable must be routed well away from power/drive cables.

System configuration and installation 5 Cross-talk between adjacent systems Cross-talk between systems on machines in close proximity must be checked when systems are installed, since high power systems have shown reception at up to 30 m. When two probes are active on adjacent machines, each OMME will only pick up the closest probe and will usually ensure no cross-talk. The installation engineer should check the closest probe is the appropriate probe ie. on the same machine as the OMME, across the entire travel of the machine. There is a further potential problem for a machine with its probe switched-off. Most CNC controls ignore the signal from a probe system unless they are executing a probing cycle. Some, however, register an error, which is a problem if the OMME picks up the signal from an inspection probe on an adjacent machine. If cross-talk is encountered, either the OMME can be re-directed, or the OMME s sensitivity can be reduced in the same way as a standard OMM. If this doesn t work then optical systems cannot be fitted to adjacent machines and radio probes should be recommended.

6 Transmission and reception envelope Transmission and reception envelope The MP700E/MP10E has a 360 transmission envelope around probe centre line over the ranges shown on the opposite page. The OMP and OMME may deviate from the optical centre line, provided opposing light cones always overlap with transmitters and receivers mutually in each others field of view (eye to eye). Absolute minimum (no reflection) plot shown.

Transmission and reception envelope 7 NOTE: Only one OMME is shown here. +60 OMME Dimensions in m (ft). +60 +45 +30 +15 +45 +30 Optical centre line +15 0 0-15 -15 2 (6.5) 3 (9.8) 4 (13.1) 5 (16.4) 6 (19.6) 7 (22.9) 8 (26.2) 9 (29.5) 9.5 (31.1) -60-30 -45 +75-30 +90-45 9.5 (31.1) 9 (29.5) 8 (26.2) 7 (22.9) 6 (19.6) 5 (16.4) 4 (13.1) 3 (9.8) 2 (6.5) 70 OMP Switch-On/Off range The OMP must be within 6 m (19.6 ft) of the OMME. Operating range The OMP must be within 9.5 m (31.1 ft) of the OMME.

8 Parts list PARTS LIST - Please quote the Part No. when ordering equipment Type Part No. Description MP10E kit A-2085-0134 MP10E 70 probe (as below), 2 x OMME, 2 mounting brackets, MI 12E and PS3-1C stylus. MP700E kit A-2107-0227 MP700E 70 probe (as below), 2 x OMME, 2 mounting brackets and MI 12E. MP10E kit A-2085-0133 MP10E 70 probe (as below), 1 OMME, 1 mounting bracket, MI 12E and PS3-1C stylus. MP700E kit A-2107-0226 MP700E 70 probe (as below), 1 OMME, 1 mounting bracket and MI 12E. MP10E kit A-2085-0132 MP10E 70 probe (as below), 2 x OMME, 2 mounting brackets, DIN-rail MI 12E and PS3-1C stylus. MP700E kit A-2107-0225 MP700E 70 probe (as below), 2 x OMME, 2 mounting brackets and DIN-rail MI 12E. MP10E kit A-2085-0131 MP10E 70 probe (as below), 1 OMME, 1 mounting bracket, DIN-rail MI 12E and PS3-1C stylus. MP700E kit A-2107-0224 MP700E 70 probe (as below), 1 OMME, 1 mounting bracket and DIN-rail MI 12E.

Parts list 9 Type Part No. Description MP700E A-2107-0159 MP700E 70 probe + battery, PS3-2C stylus, Ø8mm ball and tool kit. Factory set to optical off. MP10E A-2085-0096 MP10E 70 probe + battery, weak-link stem, Ø8mm ball and tool kit. Factory set to time out. OMME A-2033-7268 OMME. MI 12E A-2075-0323 MI 12E Interface unit. MI 12E (DIN) A-2075-0329 MI 12E Interface unit, DIN-rail mounting. Mounting A-2033-0830 Mounting bracket with fixing screws, washer and nuts bracket

10

Renishaw plc New Mills, Wotton-under-Edge, Gloucestershire, GL12 8JR United Kingdom T +44 (0)1453 524524 F +44 (0)1453 524901 E uk@renishaw.com www.renishaw.com For worldwide contact details, please visit our main website at www.renishaw.com/contact H-2000-4075-02-B