specification display applications hera spectrometer

Similar documents
specification display & lighting hera spectrometer

specification light bulb cronus bhaskar spectrometer & colorimeter for light bulb measurements

specification cylon colorimeter

operating manual iliad for Windows & Mac OS X software application rc81

Broadbandradiometer specbos 1211

Spectroradiometer specbos 1201

Chameleon Spectroradiometer

LED Lighting Flux and Color Measurement System (LFC)

NVLAP LAB CODE:

JETI Specbos Instruments

High-Accuracy Luminance & Chromaticity Measurement Comparable to Many Spectroradiometers

PGS Family Plane Grating Spectrometer from ZEISS

Miniaturized Spectroradiometer

Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

JETI SCPI commands schematic and in examples

Miniature Spectrometer Technical specifications

The Art of Light Measurement. Avantes BV Apeldoorn, The Netherlands

GL spectis 1.0 Touch The world s first smart spectrometer.

Compact High Resolution Imaging Spectrometer (CHRIS) siraelectro-optics

MK350 Portable Spectrometer

GL SPECTIS 1.0 Touch The world s first smart spectrometer

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

Microscope-Spectrometer

OtO Photonics. Light Source Datasheet. Description. Balance Light Series LS-BA. Halogen Light Series LS-HA

LED Tester BTS256-LED

NOW WITH BROADER TUNING RANGE

NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET

PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan

Model R2002. Instruction Manual. Infrared Thermometer. reedinstruments www.

Photometric Indoor Test Report

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

NVLAP LAB CODE:

Observing a colour and a spectrum of light mixed by a digital projector

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

DC Resistance Meters 2840 Series

Wavelength Meter Sensitive and compact wavemeter with a large spectral range for high speed measurements of pulsed and continuous lasers.

NVLAP LAB CODE:

NVLAP LAB CODE:

Available online at ScienceDirect. Procedia Technology 17 (2014 )

771 Series LASER SPECTRUM ANALYZER. The Power of Precision in Spectral Analysis. It's Our Business to be Exact! bristol-inst.com

Company synopsis. MSU series

Measuring colour in a world of light

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

NVLAP LAB CODE:

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

AvaLight-HAL-S-MINI Tungsten-Halogen Light Source

Color Measurement with the LSS-100P

We bring quality to light. MAS 40 Mini-Array Spectrometer

PICO MASTER 200. UV direct laser writer for maskless lithography

Outline Dimensions. Luminous Intensity (mcd) TYP. Lens Appearance. Chromaticity Coordinates. Part Number Material Emitted Color.

Gamma Scientific Display Measurement Systems

NVLAP LAB CODE:

Contents. Contents. Part 4. Specification. Part 1. Feature. Feature Merit Configuration. Specification Dimension Diagram

LEADING THE WAY in Light Measurement Systems

PLCC4 SMD Top View Package LED SMP4-RGB, RED/GREEN/BLUE

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

LED Tester BTS256-LED

Coating Thickness Measurement System

EdiLine IV Series Datasheet

Dominant wavelength (nm) or CCT (K) Royal Blue 455nm 465nm 65 mw. Blue 465nm 475nm 4.5 lm. Green 520nm 535nm 18 lm. Amber 585nm 595nm 8.

SPEC NO: DSAF1339 REV NO: V.9B DATE: NOV/10/2015 PAGE: 1 OF 6 APPROVED:

INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

White Surface Mount LED Lamp

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

Description. Kingbright

SPEC NO: DSAF1341 REV NO: V.7B DATE: AUG/20/2014 PAGE: 1 OF 5 APPROVED: WYNEC CHECKED:

5mm Phototransistor EAPLP05RDQA0

SPEC NO: DSAN4362 REV NO: V.1A DATE: JAN/10/2014 PAGE: 1 OF 5 APPROVED: WYNEC CHECKED:

PT54 LEDs. PT54 Product Datasheet. Features: Table of Contents. Applications

illumia Plus Temperature Controlled Light Measurement Systems

SPEC NO: DSAB8533 REV NO: V.19A DATE: AUG/16/2014 PAGE: 1 OF 7 APPROVED: WYNEC CHECKED:

A LATERAL SENSOR FOR THE ALIGNMENT OF TWO FORMATION-FLYING SATELLITES

MEMS Tunable Filter Products

Checked X.CAO

BTS256-PAR. Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting.

SPECTRO Series SPECTRO-3-FIO-UV-SL. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 8-11)

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

Description. Kingbright

Horticultural Lighting Test Report

SIM University Color, Brightness, Contrast, Smear Reduction and Latency. Stuart Nicholson Program Architect, VE.

Oriel MS260i TM 1/4 m Imaging Spectrograph

Spectrum Analyzer Compact and robust spectrometers with fully customizable range and resolution parameters, able to measure pulsed and continous

We bring quality to light. CAS 120 CCD Array Spectrometer

1.6X1.25mm BI-COLOR SMD CHIP LED LAMP. Features. Description. Package Dimensions. Part Number: KPTB-1612SURKCGKC. Hyper Red Green

Luminous Flux (lumens) System LM-ISP-XXXX

High specification CCD-based spectrometry for metals analysis

Cornerstone 260 1/4 m Monochromators

Checked X.CAO

In sum the named factors cause differences for multicolor LEDs visible with the human eye, which can be compensated with color sensors.

Descriptions. Kingbright

Cree XLamp XR LED Data Sheet

Description. Kingbright

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L540-C27-B25 tel: fax: lm x 0.

CST-90 LEDs. CST-90 Product Datasheet. Features: Table of Contents. Applications

PT39 LEDs. Thermally Enhanced. PT39-TE Product Datasheet. PT39-TE Product Datasheet. Features: Table of Contents. Applications

Descriptions. Kingbright

High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure. Global Office of Lisun Electronics Inc.

Photometric Test Report

Transcription:

specification display applications hera spectrometer

Contents 1 Hera: cost effective spectrometer for display measurements... 3 2 Highlights... 3 3 Speed & ease of use... 4 4 General specification Hera 01... 4 5 Hera lens specifications... 5 6 Speed & performance, Hera 01 20mm... 6 7 Hera 20mm dimensions... 7 8 Hera 10mm dimensions... 8 9 Hera 5mm dimensions... 9 2

1 Hera: cost effective spectrometer for display measurements The Hera 01 with lens is the ideal spectrometer for display measurements where ease of use, stability, performance and price are essential. A perfect solution for hassle free integration in production processes. 2 Highlights Spectral range 380-780nm Spectral output or colour values output are both possible Auto-range function Luminance range of 0.05 6000 cd/m² Excellent linearity over entire dynamic range Dark current compensated, virtually zero over entire integration range Holographic grating for low stray light USBTMC compliant, SCPI command set, high speed device Numerous interfaces, ideal for system integration All spectral calculations are done inside Several lens system options Robust housing 3

3 Speed & ease of use Admesy strongly believes in developing and manufacturing devices where ease of use and speed are key factors. In order to achieve these aspects, Admesy considers the following aspects of spectrometers to be taken care of. Wavelength calibration Dark current Linearity Absolute calibration Calculations and compensations are done in a staggering 14ms. All this is possible due to the high speed processor inside the Hera combined with algorithms developed for this specific device. In production processes, no external calculation power is needed from computers. Data can be used directly in production settings without any delay of processing data afterwards. This saves time and processing power of the operating system of a production line. Additional feature is the Hera s auto-range function: the most ideal integration time is chosen automatically. Manually, the integration time can be changed. 4 General specification Hera 01 Hera 01 Model Hera 01 VIS Spectral range 380-780nm Optical resolution 2.3nm (FWHM) Order sorting filter 2 nd order sorting filter Wavelength accuracy +/- 0.5nm Stray light <0.2% (measured at 400nm with 455nm cut-off filter with broadband light source) Luminance accuracy 1 +/-2% Chromaticity accuracy 1 +/- 0.0015 Non Linearity < 1% Integration time 1.3ms 20s Spectral resolution Selectable 0.5nm-1nm-2.5nm-5nm-10nm Interfaces High speed USB, RS232, Ethernet, Trigger connections Measurement parameters Spectral output, radiometric data or colour data (Lumen, x,y, DWL, PWL, CRI, CCT, etc.) Data processing time 14ms Size (LxWxH) 95 x 81 x 61mm (without optical system) Weight 650 gram Operating temperature 10-35 C Power consumption 1250mW Wavelength accuracy +/-0.5nm 1 After calibration to the working standard 4

5 Hera lens specifications The Hera series is available with several lens systems, available as fixed optics and optics with fibres. For fibre connections, Admesy uses M8 connectors. This connector has been developed to connect the optical fibre in a consistent way to ensure the best possible repeatability. Model 1 2 3 4 5 Description 20mm lens 10mm lens 5mm lens IDMS VMS Target Display Display Display Display Variable message signs FOV ¹ N/a N/a N/a +/-1º +/-1.5º Acceptance +/-0.3º +/-0.6º +/-0.6º +/-1º +/-0.5º angle Luminance 0.05 6000 0.05 6000 0.2 20,000 TBD TBD range (cd/m²) Working 100mm 100mm 100mm 100mm 1910mm distance (WD) Spot size at WD 21mm 12.6 7.7 11.4 106 Spot size at WD 20.5mm 11.3 6.3 9.6 103.6 50mm Spot size at WD +50mm 21.5mm 13.9 9.1 13.2 108.6 1 Models 1, 2 and 3 are collimating lens systems and can be used closely to the display. 5

6 Speed & performance, Hera 01 20mm Measurement parameters Used target display LCD display with LED backlight Spectral resolution 1nm Average 1 Auto-range function Off Temperature 24º Repeatability¹ ² Luminance level Luminance (2 sigma) Colour (2 sigma) Measurement time (ms) 250cd/m² <0.3% +/- 0.0005 50 10cd/m² <0.5% +/- 0.0005 1000 1cd/m² <3% +/- 0.002 2000 0.25cd/m² <3% +/- 0.002 5000 1 Speed and repeatability are directly related to each other; a lower repeatability can increase speed and vice versa. 2 Measurements are real life taken measurement and can vary slightly from device to device. Results for the 10mm hera are the same as for the 20mm, for the 5mm above luminance levels should be multiplied by 4. 6

7 Hera 20mm dimensions 7

8 Hera 10mm dimensions 8

9 Hera 5mm dimensions 9

Admesy B.V. Sleestraat 3 6014 CA Ittervoort The Netherlands T +31 (0)475 600 232 F +31 (0)475 600 316 www.admesy.com info@admesy.com The material in this document is subject to change. No rights can be derived from the content of this document. All rights reserved. No part of this document may be reproduced, stored in a database or retrieval system, or published in any form or way, electronically, mechanically, by print, photo print, microfilm or any other means without prior written permission from the publisher. Version 1.0.13 09/2018 10