Energy Management Energy Meter Type EM110

Similar documents
Energy Management Energy Meter Type EM110

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM112

Energy Management Energy Meter Type EM340

Energy Management Energy Analyzer Type EM111

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

Energy Management Energy Meter GM3D

Energy Management Energy Analyzer Type EM112

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

Energy Management Energy Analyzer Type EM210 MID

Energy Management Energy Meter GM3T E GM3T-RS485 E

Energy Management Energy Analyzer Type EM210

Energy Management Energy Meter Type EM21 72R Retro-Fit

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management Energy Analyzer Type EM24 DIN

Energy Management Energy Analyzer Type EM280-72D

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

Energy Management Energy Analyzer Type EM270-72D

Energy Management Energy Analyzer Type EM24 DIN

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Power analyzers and Energy Meters Power Analyzer Type WM14-96

MID. Energy Management Energy Analyzer Type EM Product Description. How to order EM26 96 AV5 3 H O3 S1 PF A. Type Selection EM26 96

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Energy Management Energy Analyzer Type EM24 DIN

Energy Management Energy Analyzer Type EM24 DIN

08/07/2015

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

08/07/2015

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications

EN61036 EN61268 CARLO GAVAZZI

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

C series Product brief

Energy Management Smart Modular Power Analyzer Type WM30 96

High precision measurement system for current and voltage IHC-A/B-RM01/03

emeter1 Single-phase energy meter emeter3 Three-phase energy meter User manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT!

Energy Management Compact Power Transducer Type CPT-DIN Basic version

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG400AR/CR. Technical Data

02/11/2015

Energy Management Modular Smart Power Transducer Type SPT-90

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG310AR/CR. Technical Data

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

INDUSTRIAL+COMMERCIAL ZMG400AR/CR, ZFG400AR/CR TECHNICAL DATA. IEC-specific data. Current. Measurement Accuracy. Measurement Behaviour.

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

Environmental Influences. Display. Inputs and Outputs. Electromagnetic Compatibility. Communication Interfaces. Insulation Strenght.

02/11/2015

05/09/2012

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

RS Pro ENGLISH. Datasheet

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Jewell DPM EINE BEST IN CLASS

Monitoring Relays 3-Phase Active power Types DWB02, PWB02

02/11/2015

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

INDUSTRIAL+COMMERCIAL ZMD310AT/CT TECHNICAL DATA. Measurement Accuracy. Measurement Behaviour. MID-specific data. Current (for Class B) General

Introduction DIN rail mounted electricity meters

7E Series - Energy meter. Features PTB 1

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Monitoring Relays 3-Phase Active power direction Types DWB03, PWB03

Technical Data Sheet. x1000. kwh R Y B

22/10/2012

Energy Management Modular Power Analyzers Type WM2-96

02/11/2015

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17LLBM asymmetrical flashing relay s V AC - solid state output

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Solid-state Timer H3DS

INDUSTRIAL+COMMERCIAL ZMD400AR/CR, ZFD400AR/CR TECHNICAL DATA. Frequency. IEC-specific data. Current. Measurement Accuracy.

02/11/2015

83 Series - Modular timers 16 A. Features

Electronic timer CT-TGD.22

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

11/03/2013

Energy Management Energy meters Type EM2-DIN

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

MID energy meter B21 Single-phase energy meter, 65 A

38 Series - Relay interface modules A

38 Series - Relay interface modules A

02/11/2015

02/11/2015

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

02/11/2015

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Transcription:

Energy Management Energy Meter Type EM110 Single phase energy meter Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Electro-mechanical display Energy readout on display: 6+1 digit Measurements on display: total kwh Direct current measurement up to 45AAC Self power supply Dimensions: 1-DIN module Protection degree (front: IP51 Pulse output (by open collector PNP Detects wrong current direction Product description Single-phase energy meter with electro-mechanical data displaying; particularly indicated for active energy metering and for cost allocation in applications up to 45 A (direct connection, especially when energy reading is necessary during power down. Housing for DIN-rail mounting, with IP51 front degree protection. The meter is provided with pulse output proportional to the active energy being measured. STANDARD Not certified according to MID Directive. Cannot be used for fiscal (legal metrology. How to order EM110-DIN AV8 1 X O1 X Model Range code System Power supply Output Option Type Selection Range code System Power supply Output AV8: AV7: 230VLN AC - 5(45A (Direct connection 120VLN AC - 5(45A (Direct connection 1: 1-phase 2-wire X: Self power supply -30% +20% of the rated measuring input voltage, 45 to 65Hz O1: pulse output Option X: none Specification are subject to change without notice EM110 DS 090415 1

Input specifications Rated Inputs Current type Current range Nominal voltage Accuracy (@25 C ±5 C, R.H. 60%, 45 to 65 Hz AV7 1-phase loads, direct connection 5(45A 230VLN AC (AV8 option, 120 VLN (AV7 option Imin=0.25A; Ib: 5A, Imax: 45A; Un: 120VLN -30% +30% AV8 Imin=0.25A; Ib: 5A, Imax: 45A; Un: 230VLN -30% +20% Current (AV7, AV8 From 0.04Ib to 0.2Ib: ±(0.5%RDG+1DGT From 0.2Ib to Imax: ±(0.5%RDG Phase-neutral voltage In the range Un: ±(0,5% Frequency Active power Power factor Reactive power Energies Start-up current: Start-up voltage RDG Range: 45 to 65Hz. From 0.05 In to Imax, within Un range, PF=1: ±(1% RDG From 0.1 In to Imax, within Un range, PF=0.5L or 0.8C: ±(1% RDG ±[0.001+1%(1.000 - PF RDG ] From 0.05 In to Imax, within Un range, sinphì=1: ±(2% RDG From 0.1 In to Imax, within Un range, sinphì=0.5l or 0.8C: ±(2% RDG Class 1 according to EN62053-21 20mA (AV7, AV8 Self-consumption is not measured. 84V (AV7, 161V (AV8 Resolution Energy Energy additional errors Influence quantities Temperature drift Sampling rate 0.1 kwh According to EN62053-21 200ppm/ C 4096 samples/s @ 50Hz 4096 samples/s @ 60Hz Display Type Electro-mechanical, h 5 mm Energies read-out Total: 6+1 digit Only positive energy is integrated Max. and Min. indication Max. 999 999.9 Min. 0.0 LEDs Flashing red light pulses according to EN50470-3, EN62052-11, 1000 imp./ kwh (min. period: 90ms Fix orange light: wrong current direction Current overloads Continuous 45A, @ 50Hz For 10ms 1350 A Voltage Overloads Continuous 1.2 Un For 500ms 2 Un Input impedance Voltage input 230VL-N > 750 Kohm Voltage input 120VL-N > 750 Kohm Current inputs: 5(45 A < 0.5 VA 2 Specification are subject to change without notice EM110 DS 090415

Output specifications Static output Purpose Pulse rate For pulse output proportional to the active energy (kwh 1000 kwh per pulse Pulse ON duration Output type Load 30ms, according to EN62052-31 open collector PNP V ON 1 VDC; max. 100 ma V OFF 80 VDC max General specifications Operating temperature -25 to +65 C, indoor, (R.H. from 0 to 90% noncondensing @ 40 C Storage temperature -30 C to +80 C (R.H. < 90% noncondensing @ 40 C Installation category Cat. III Insulation (for 1 minute 4000 VAC RMS between measuring inputs and digital/serial output (see table 4000 VAC RMS Dielectric strength 4000 VAC RMS for 1 minute EMC Electrostatic discharges Immunity to irradiated Electromagnetic fields Burst Immunity to conducted disturbances According to EN62052-11 15kV air discharge; Test with current: 10V/m from 80 to 2000MHz; Test without any current: 30V/m from 80 to 2000MHz; On current and voltage measuring inputs circuit: 4kV 10V/m from 150KHz to 80MHz Surge On current and voltage measuring inputs circuit: 4kV; Radio frequency According to CISPR 22 Standard compliance Safety EN62052-11 Metrology EN62053-21, EN50470-3 Approvals CE Connections Cable cross-section area Measuring inputs: 6 mm 2, with/without metallic cable ferrule; Max. screw tightening torque: 1.1 Nm Other terminals 1.5 mm², Min./Max. screws tightening torque: 0.4 Nm Housing Dimensions (WxHxD 17.5 x 63 x 90 mm Material Noryl, self-extinguishing: UL 94 V-0 Sealing covers Included Mounting DIN-rail Protection degree Front IP51 Screw terminals (cable inputs IP20 Weight Approx. 75 g (packing included Power supply specifications Self power supply AV8 230VAC VL-N, -30% +20% 50/60Hz AV7 120VAC VL-N, -30% +30% 50/60Hz Power consumption 1.0W, 8VA Specification are subject to change without notice EM110 DS 090415 3

Insulation (for 1 minute between inputs and outputs Measuring input Auxiliary power supply Digital output Measuring input - 0 kv 4 kv Auxiliary power supply 0 kv - 4 kv Digital output 4 kv 4 kv - Accuracy according to EN50470-3 kwh, PF=accuracy (RDG depending on the current Percentage error limits for class index B +1.5% +1% 0% -1% -1.5% PF=1 0.25A(I min 0.5A(I tr 5A(I n 45A(I max 0.05A(I ref (0,1I ref PF=L0.5 0.5A(I tr or C0.8 (0,1I ref 5A(I n 45A(I max Class 1 accuracy limits (Active energy 5(45A Start-up current: 20mA 4 Specification are subject to change without notice EM110 DS 090415

Wiring diagrams Current (F 315mA Fig.1 Pulse output Fig.2 Vdc Out GND Vdc GND Out Open collector outputs: the load resistance (Rc must be designed so that the closed contact current is under 100 ma (V on is equal to 1 V dc. DC voltage (V off must be less than or equal to 80 V. Front panel description 5 4 1 1. Display Electro-mechanical type with total kwh indication 2. LED LED proportional to kwh reading 3. Serial number Area reserved to serial number 3 2 4. Protection covers for tamper proof The tamper proof overs are included 5. Tamper proof The instrument can be sealed in two points: upper cover and lower cover Dimensions 17 43 90 45 62 49 60 Specification are subject to change without notice EM110 DS 090415 5